Important safeguards
• This appliance is designed for home air conditioning and must not be used for other purposes.
• It is dangerous to modify or alter the characteristics of the appliance in any way.
•The appliance must be installed in conformity with legislation in force in the country concerned.
• If the appliance requires repair, contact a Service Centre authorised by the manufacturer only. Repairs carried out by unauthorised personnel may be dangerous.
•If the power cable is damaged, it must be replaced by the manufacturer, an authorised service cen­tre or a qualified electrician in order to eliminate all risk.
• This appliance must be used exclusively by adults.
• Do not allow children or unfit persons to use the appliance without adequate supervision.
• Do not allow children to play with the appliance.
•The appliance must be connected to an efficient earth system. Have your electrical circuit checked by a qualified electrician.
• Do not use extension cables.
• Before cleaning or maintenance operations, always unplug the appliance from the mains socket.
• Do not move the appliance by pulling the power cable.
• Do not install the appliance in rooms containing gas, oil or sulphur. Do not install near sources of heat.
• Do not rest heavy or hot objects on top of the appliance.
•Clean the anti-microbial filters at least once a week.
•Avoid using heating appliances near the air conditioner.
• Always transport the appliance upright or resting on one side.
•Use the appliance as described in this instruction manual only.
•As with all electrical equipment, whilst the instructions aim to cover as many eventualities as possible, caution and common sense should be applied when operating and installing this appliance.
•At the end of its working life, take the appliance to a special collection centre.
• The materials used for packaging can be recycled. You are therefore recommended to dispose of them in special differentiated waste collection containers.
• The refrigerant gas R407c conforms to EC regulations on the environment. Avoid perforating the refri­gerant circuit of the appliance.
• Keep the appliance at least 50 cm away from flammable substances (alcohol etc) or pressurised containers (e.g. aerosol cans).
DESCRIPTION 1 air outlet grille
2 control panel 3 castors 4 handles 5 filter 6 evaporator air intake grille 7 air exhaust hose housing
8 condenser air intake grille 9 power cable 10 drain hose cap 11 flange with cap 12 air exhaust hose 13 window outlet 14 remote control unit (some models only)
16
The instructions below will enable you to prepare your air conditioner for operation as efficiently as possible.
Before use, make sure the air intake and outlet grilles are unobstructed.
AIR-CONDITIONING WITHOUT INSTALLATION
Just a few simple steps and your comfort is ensured with your air conditioner:
• Fit the air exhaust hose in the housing
at the back of the appliance.
Insert it as shown in figure A.
7
12
• Unscrew the plastic end of the air exhaust hose and screw on the window outlet
.
• Place the air conditioner near a window or French window.
• Make sure the air exhaust hose is unob­structed.
13
12
Preparing for use
B
Keep the air hoses as short and free of curves as possible to avoid constrictions.
ELECTRICAL CONNECTIONS
Before plugging the appliance into the mains socket, check that:
• The mains power supply corresponds to the value indicated on the rating plate on the back of the appliance;
• The mains socket and electrical circuit are adequate for the appliance;
• The mains socket matches the plug. If this is not the case, have the plug replaced;
• The mains socket is adequately earthed. Failure to follow these important safety instructions absolves the
manufacturer of all liability.
The power cable must be replaced by a qualified professional only.
• Open the window or French window sligh­tly and position the outlet as shown in figu­re B .
13
2
1
17
GB
Preparing for use
AIR-CONDITIONING WITH INSTALLATION
If required, your appliance can also be instal­led semi-permanently (Fig. C).
• Fit the wall flange accessory provi­ded in the hole.
• Fit the air exhaust hose in the relevant hose located on the rear side of the appliance. (fig. A page 16).
•Insert the other end of the hose on the
flange as shown in fig. E.
11
12
12
11
Proceed as follows:
• Drill a hole in an outside wall or through a window pane. Respect the height and dimensions of the hole given in figure D.
When the hose is not fitted, the hole can be closed with the flange cap
.
NOTE.
When installing the air conditioner semi-per­manently, you should leave a door slightly open (as little as 1 cm) to guarantee correct ventilation.
11
12
in the window pane
in the wall: you are recommended to insulate the sec­tion of wall using suitable insulation.
in the woo­den kick­board of a French win­dow
D
E
Keep the air hoses as short and free of curves as possible to avoid constrictions.
C
134
30 cm
30 cm
MAX100 cm
MIN 35 cm
18
Control panel
DESCRIPTION OF THE CONTROL PANEL
A ON/OFF button B MODE selection button
Air conditioning, dehumidifying, fan.
C Fan speed selection button (MAX/MED/MIN) DTimer button E Programmed operation increase temperature/time button F Programmed operation decrease temperature/time button G Display Displays the temperature values set and the programmed operating time HTimer in operation indicator light I/L/M Fan speed lights N Fan mode light O Air-conditioning mode light P Dehumidifying mode light Q Alarm light