De'Longhi GB-5715110401 Owner's Manual

4
Important safeguards
• Use this appliance only as described in this instruction manual. As with any electrical appliance, the instructions aim to cover as many situations as possible. Caution and common sense should be used when operating and installing this air conditioner.
• This appliance has been manufactured to cool and dehumidify domestic environments and must not be used for other purposes.
• It is dangerous to alter or modify the unit's characteristics in any way.
• The appliance must be installed in accordance with the relevant national legislation.
• Should repairs be necessary, contact the nearest authorized Repair Service Center. Unautho-
• The appliance is not intended for use by persons (including children) with reduced physical, sen-
If the power cable is damaged, it must be replaced by the manufacturer or an authorized
• Always ensure the appliance is plugged into a grounded 3-prong outlet. If you have any doubts
• Do not use extension cables.
• Before cleaning or maintenance operations, always unplug the unit from the outlet.
• Do not pull on or place strain on the power cord when moving the appliance.
• The appliance should not be installed where the atmosphere may contain combustible gases,
• Do not rest hot or heavy objects on the appliance.
• Clean the filters at least once a week.
• Avoid using heaters near the unit.
• The unit should be transported in a vertical position. If this is not possible secure the unit at an
• Before transporting the unit, drain the unit. After transportation, wait at least 6 hours before
• The packaging materials can be recycled. You are therefore recommended to place them in
• This appliance is fitted with a special safety device. When the compressor switches off, this
WARNING: Changes or modifications not expressly approved by the party responsible for com-
SPECIFIC WARNINGS FOR APPLIANCES WITH R410A REFRIGERANT GAS
R410A refrigerant gas conforms to EC regulations on the environment. Avoid perforating the refrigerant circuit of the appliance.
ENVIRONMENTAL INFORMATION:
This unit contains fluorinated greenhouse gases covered by the Kyoto Protocol. Maintenance and disposal must be carried out by qualified personnel only (R410A, GWP=1975).
rized servicing can be dangerous.
sory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
technical service centre in order to avoid all risk.
check with a qualified electrician.
oil or sulphur, or near heat sources.
angle, do not lie it horizontally.
switching the unit on.
the special containers for differentiated waste collection.
device prevents it from switching on again for at least 3 minutes.
pliance could void the user's authority to operate the equipment.
SAVE THESE INSTRUCTIONS
.
THIS PRODUCT IS FOR HOUSEHOLD ONLY
DESCRIPTION
1 air outlet grille 2 control panel 3 castor wheels 4 handles 5 filter 6 air intake grille 7 air exhaust hose housing 8 drainage hose
9 power cable 10 wall flange 11 air exhaust hose 12 window outlet 13 castor locks 14 remote control 15 window bracket with locking pins
5
GB
Setting up your portable
air conditioner
TO AVOID DAMAGE TO THE UNIT:
NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the unit has been on its side, oil needs to return to the compressor to ensure proper function. Without allow­ing the unit this time (6-24 hours) the unit may function for only a short time, and then the com­pressor will break down from lack of oil.
ELECTRICAL CONNECTIONS
Before plugging the appliance into the outlet, check that:
• The outlet’s power supply corresponds to the value indicated on the rating label on the back of the appliance;
• The outlet and electrical circuit are adequate for the appliance;
• The outlet is a 3-hole grounded outlet . If this is not the case, you must choose another outlet.
Failure to follow these important safety instructions absolves the manufacturer of all liability.
The instructions below will enable you to prepare your air conditioner for operation as efficiently as possible. Before use, make sure the air intake and outlet grilles are unobstructed.
If it becomes necessary, the power cable must be replaced by a qualified professional only.
Other set-up methods:
• Thanks to the locking pins, it’s possible to use the window bracket also for sliding windows. Position the hole of the bracket so to allow a correct installation of the exhaust hose (see figure C).
• If you have a casement window (figure D) follow steps 2 & 3 and place the window outlet (12) outside the window to exhaust the hot air.
For help with installation, operation, and for all accessories and spare/replacement parts, Please contact our toll free cus­tomer service call center at:
1-800-322-3848 [US only]
Monday – Friday 8:30am – 5:00pm ET Or log onto our website at
www.delonghiusa.com.
AIR CONDITIONING WITHOUT INSTALLATION
NOTE: Keep the air hoses as short and free of
curves as possible to avoid constrictions.
FOR OPTIMAL RESULTS SET-UP IN A DOU­BLE-HUNG WINDOW:
1) Place the bracket in the window sill, extend the bracket fully within the window frame, fix the bracket by using the pin then lower the window onto the bracket. (Should the window bracket be too large for the window. The plastic can be cut with a saw by a qualified professional.)
2) Fit the air exhaust hose in the housing at the back of the appliance. Insert it as shown in figure A.
3) Connect the window outlet (12) to the other end of the exhaust hose.
4) Insert the window outlet end of the exhaust hose into the slot of the window bracket (fig. B).
A
B
C
D
in the window pane
in the wall: you are recommended to insulate the section of wall using suitable insulation.
in the wooden kickboard of a French window
F
Semi-permanent installation
SEMI-PERMANENT INSTALLATION
If required, your appliance can also be installed semi-permanently (Fig. E).
Proceed as follows:
• Drill a hole ø 5,25 inches (134 mm) in an outside wall or through a window pane. Respect the dimensions and height of the hole given in figure F and G.
• Fit the wall flange (10) into the hole.
• Fit the air exhaust hose (11) in the rele-
vant housing located on the rear side of the appliance. (fig. A page 5).
• Fit the end of the hose (11) to the wall flange (10) as shown in fig. G .
When the hose (11) is not connected, the dril­led hole can be closed with the flange cap (10).
NOTE: When installing the air conditioner semi-permanently, you should leave a door slightly open little as 1/2 “ (1 cm) to guar­antee correct ventilation and room pressure.
6
Keep the air hoses as short and free of curves as possible to avoid constrictions.
“As special tools are required for installa­tion, we suggest you have the applian­ce installed by specialized personnel.”
E
G
7
Control panel
DESCRIPTION OF THE CONTROL PANEL
A ON/STAND-BY button B MODE selection button:
Air conditioning, dehumidifying, fan.
C Fan speed selection button (HIGH/MED/LOW/AUTO) D Timer button E Programmed operation increase temperature/time button F Programmed operation decrease temperature/time button G Display Displays the temperature values set and the programmed operating time H Timer in operation indicator light I/L/M/N Fan speed lights and AUTO lights O Fan mode light P Dehumidifying mode light Q Air conditioning mode light R Remote control receiver
THE CONTROL PANEL
GB
Never turn the air conditioner off by unplugging from the outlet. Always press the button, then wait for a few minutes before unplugging. This allows the appliance to perform a cycle of checks to verify operation.
Q
A
BEF
N
HRG
C
P
O
D
M
L
I
8
Operation
TURNING THE APPLIANCE ON
Plug into an outlet. Two lines appear on the display indicating that the appliance is in stand­by. Press the ON/STAND-BY button (A). When turned on, the air conditioner starts operating in the same mode as when it was turned off. Press the MODE button (B) until the light corresponding to the desired mode lights up:
Light (Q): AIR-CONDITIONING MODE
Light (P): DEHUMIDIFYING MODE
Light (O): FAN MODE
AIR CONDITIONING MODE
Ideal for hot muggy weather when you need to cool and dehumidify the room. To set this mode: press the + (E) or - (F) buttons until the desired tempe­rature is displayed. Then select the fan speed by pressing the “FAN” button (C) until the light corresponding to the required fan speed lights up:
HIGH: MAXIMUM SPEED to achieve the target temperature as rapidly as
possible
MED: MEDIUM SPEED reduces noise levels while maintaining a comfor-
table temperature
LOW: LOW SPEED for silent operation and maximum energy efficiency AUTO: AUTO: the appliance automatically selects the most suitable
fan speed in relation to the temperature set on the digital display and current room temperature.
The most suitable temperature for the room during the summer varies from 75°F to 81°F (24 to 27°C). You are recommended, however, not to set a temperature much below the outdoor temperature
DEHUMIDIFYING MODE
Ideal to reduce room humidity (spring and autumn, damp rooms, rainy periods, etc). In dehumidifying mode, the appliance MUST be set-up in the same way as for air conditioning, with the air exhaust hose attached to enable the moisture to be discharged outside. When the dehumidifying mode is selected, the light (P) comes on and “ ” appears on the display. At the same time, the AUTO fan light (N) comes on.
In this mode, fan speed is selected automatically by the appliance and cannot be set manually.
FAN MODE
The unit operates without cooling or dehumidifying. This mode provides ventilation only. When using the appliance in this mode, the air exhaust hose does not need to be connected. Adjust fan speed by pressing the “FAN” button (C) as described for the air-conditioning mode. In this mode, AUTO speed cannot be selected. The fan speed selected will be displayed.
Loading...