DeLonghi CT250 User Manual GB

Dear Sir/Madam We thank you for purchasing this Pinguino
appliance and congratulate you on your wise choice.
Please make the time and effort to read this manual carefully.
Becoming familiar with the Pinguino is an essential step if you are to benefit fully from its exceptional qualities, during both installation and actual use.
We hope that the Pinguino will become a welcome friend this summer, a source of comfort and refreshment.
Best wishes De Longhi S.p.A.
Pinguino is a very versatile air conditioner because it can operate both through water condensation as well as air condensation. The User may choose the operational method:
1) WATER FUNCTION - When excellent efficiency, lower energy consumption, and greater speed in reaching the ideal climatic conditions are desired. This function is especially useful when the appliance is just turned on and when the room temperature is quite warm.
When the water reserve (in the tank) has been used up, Pinguino automatically changes to the air functioning mode.
2) AIR FUNCTION - This is the normal air conditioning function.
TECHNICAL DATA Tab.1
WATER FUNCTION - AIR FUNCTION Power supply voltage (V) 220...240 V ~ Frequency (Hz) 50 Electric power consumption (A) 3,85 - 4,45 Max.power consumption (air-condit.mode) (W) see rating label *Max.power consumption (heating mode) (W) see rating label Cooling capacity (Frig/h, W, Btu/h) see rating label Cooling capacity (Frig/h, W, Btu/h) see rating label Air flow capacity (m3/h) 360 Timer 24 h Dimensions: width (mm) 560
height 735 depth 390
Net weight (kg) 44
Technical data subject to change without prior notice
* Model CT250H only
IDEAL OPERATING CONDITIONS Tab.2
ROOM TEMPERATURE 21 ÷ 32°C
ROOM HUMIDITY FACTOR BELOW 80%
Note: When indoor temperature exceeds 32°C, the appliance should be operated with water.
IDEAL OPERATING HEATING CONDITIONS Tab. 3
ROOM TEMPERATURE
max 5° C
Tab. 4
Air outlet grid
Control panel
Programmer (timer) Timer ON/OFF
(model 250H only)
Water container
Castors Castor stops
Water collecting tray
Water container compartment door
Air filter
Air intake grid Warranty envelope
Exhaust hose compartment Power cable compartment
Handle
Water collecting tray drainage tube
DESCRIPTION
PARTS
SUPPLIED
Exhaust hose
Stopper + flange
Castor stop
De-scaling fluid
Window nozzle
Suction cup set
1
1
2
1
1
1
TIONING FUNCTION
Our air-conditioner is portable and versatile: it can be used as a permanent installation or wise easily moved from one room to another.
The appliance must be fitted at least 30 cm. from the surrounding walls.
3
0
c
m
30 cm
When installed permanently, all air discharged from the rear hose is extracted from the room in which the appliance is installed. Check that the room (particularly if it is small) is not “air-tight”; a drop in pressure could cause a malfunction and thereby activate the safety switch. Air entering the room through door and window cracks is normally sufficient. If necessary, leave a door slightly ajar (a gap of approx.1 cm. is adequate).
The unit can also be used as a “temporary” installation for use in any room with a window or french window; this “temporary” installation can be used at any time until it is ready for permanent installation.
Note.: In either case, check that the unit is resting on at “perfectly level” surface. If necessary, use the 2 castor stops for the front castors.
30 cm
PERMANENT INSTALLATION WITH PLUG AND FLANGE The outlet holes must be connected to the outside of the building and cannot be made in any wall or panel.
A1 in a window pane
A2 through the wooden
base-section of a glass door
A3 in the wall
Ø 95 mm