Important safeguards
• Use this appliance only as described in this instruction manual. As with any electrical appliance, the instructions aim to cover as many eventualities as possible. Caution and common sense should be used when operating and installing this air conditioner.
• This appliance has been manufactured to cool and dehumidify domestic environments and should not be used for other purposes.
• It is dangerous to alter or modify the unit's characteristics in any way.
• The appliance must be installed in line with the relevant national legi­slation.
• Should repairs be necessary, contact the nearest authorized De’Lon­ghi Repair Service Center. Unauthorized Delonghi servicing can be dangerous.
• This appliance is to be used by adults only; keep away from children.
• In the case that the power cord becomes damaged, this must be substi­tuted only by specialized personnel authorized by the manufacturer.
• Always ensure the appliance is grounded. If you have any doubts check with a qualified electrician.
•Avoid using extension cords with the unit.
• Before cleaning or maintenance operations, always unplug the unit from the outlet.
•Do not pull on or place strain on the power cord when moving the appliance.
• The appliance should not be installed where the atmosphere may contain combustible gases, oil or sulphur, or near heat sources.
• Do not rest hot or heavy objects on the appliance.
• Remember to perform the descaling procedure at the end of each season (see page 13). In areas where the water is particularly hard (rich in minerals), the use of a commercial descaling product added to the water is recommended. This can be requested to De’Longhi America, Inc.
• Clean the filters at least once a week.
•Avoid using heaters near the unit.
The unit, should be transported in a vertical position. If this is not possible secure the unit at an angle, do not lie it horizontally.
• Before transporting the unit, drain the condensation collecting-tray and tank. After transportation, wait at least 1 hour before switching on the unit.
• The packaging materials can be recycled. You are therefore recom­mended to place them in the special containers for differentiated waste collection.
SAVE THESE INSTRUCTIONS
5
During the summer, optimum comfort is achieved with a temperature of around 75°F (24 °C)
and 50% relative humidity.
An air conditioner removes moisture and heat from the room where it is located. One advantage
of portable air conditioning units over window models is that they can easily be moved from one
room to another in the home or even transferred between different buildings.
The hot air in your room is passed through
a coil cooled by refrigerant gas,
removing excess heat and moistu-
re before being discharged
again into the room.
In single unit models, the hot
and moist air is discharged
outside.
How does your Pinguino work
ENGLISH
6
The following instructions will help you set up your air conditioning unit as efficiently as possible.
AIR CONDITIONING WITHOUT INSTALLATION FOR INSTANT TEMPORARY USAGE
With just a few simple operations, Pinguino will restore comfortable conditions in your room:
• Fit the exhaust hose to the coupling
on the back of the unit as shown in figure A.
825
•With a double casement window, use the suction cups provided to hold the two halves of the window together (fig. C).
27
• Fit the window attachment to the end of the hose .
•Place the unit near a window or door.
• Open the window, or the door slightly and place the window attachment as shown in figure B.
26
25
26
Setting up
B
C
1
2
A
• Pinguino is equipped with an adjustable window bracket . If you have a sliding window, place the bracket on the win­dow sill, extend the bracket fully within the window frame and lower the window onto the bracket. Insert the nozzle of the exhau­st hose into the slot, then connect the hose to the air conditioner (Fig. D). With the wing nut it’s possible to use the window bracket also for sliding windows. Position the hole of the bracket to allow a correct instal­lation of the exhaust hose.
30
window bracket
D
7
ENGLISH
Setting up
AIR CONDITIONING WITH INSTALLATION
For more efficient use Pinguino can also be semi-permanently installed (Fig, G)
• Fit the flange supplied to the hole.
• Fix the hose to the coupling on
the back of the unit (figure A).
• Attach the end of the hose to the flan-
ge as shown in the figure I.
24
25
825
24
To install, proceed as follows:
• Make a hole in a outside wall or through the glass of a window. Check the height and dimensions given in figure H
12"
12"
30 cm
30 cm
4"
100
MAX 47" (120 cm)
MIN 12" (30 cm)
When the hose is not attached, close the
hole with the stopper on the flange .
NOTE: When the unit is installed semi-permanently, we recommend leaving a door slightly open (1cm (1/2”) is enough) to ensure an adequa­te exchange of air.
24
25
in a window pane
in the wall: for optimum results, insulate the sec­tion of the wall with suitable insu­lating material.
in the wood sill of a window
H
I
If you have a sliding door, use the additional set provided in order to extend the accessory to the desired length; joining the two parts (fig. E), adjust the total length according to your needs, then fit the bracket with the relevant nuts, close the door and connect the hose (fig. F).