DeLonghi RADIANT, 182H, 541101 User Manual

RADIANT HEATER
SAFETY INSTRUCTIONS
(KEEP IN A SAFE PLACE)
SPARE COPIES OF THIS LEAFLET CAN BE OBTAINED FROM YOUR DEALER
U.K. AGENT:
De’Longhi Ltd.
15/16 Bridle Close - Stewarts Road Finedon Industrial Estate Wellingborough Ph 0933 442040
X-Press 1-03-2002 11:54 Pagina 1
Heater safety instruction. (Keep in a safe place).
Spare copies of this leaflet can be obtained from your dealer.
1 Always use heater in accordance with
instructions supplied with each heater. Keep Instructions in a safe place.
2 Do not place clothes or other materials
on the heater, as apart from the danger of fire their presence could affect the effi­cient working of the appliance.
3 Do not position heater close to chairs and
fabrics.
4 Do not move heater from room to room
when it is lit.
5 Do not position heater alongside a wall or
near curtains, etc. Always face heater towards centre of room. Special care should be taken if the hea­ter is on a surface where it can move or twist on its wheels or castors if knocked by a child or dog, etc.
6 A LEAK WILL SMELL
If a leak is suspected, turn the gas off at cylinder. Do not disconnect the regulator. Extinguish all naked lights. Check all con­nections. Slowly turn the gas on and brush the connections with soapy water or liquid detergent - a gas leak will form bubbles. If a leak is found turn the gas off and inform your Dealer. DO NOT use the heater again until it has been inspected by your Dealer. If the cylinder valve appears to be leaking when turned off, refit the Black Branch Cap or Orange Valve Cap.
- This appliance MUST NOT be used in basements, high rise flats, bathrooms or bedrooms and in rooms having volume less than 15m
3
(30m3in living rooms) for three burner models,
18m
3
(36m3in living rooms) for two burner models.
- Be sure installation is complying to local standard.
- Do not install the appliance in a room which might contain gas, oil or sulphur, or near sour­ces of heat.
- The appliance should not be used at altitudes exceeding 1500 m. as the analyzer may be triggered off causing the appliance to switch off unexpectedly.
Ventilation
Use only in a well ventilated room (see page 4 of these instructions, where applicable). Do not change cylinders in the presence of naked lights.
2
X-Press 1-03-2002 11:54 Pagina 2
SCREW ON REGULATOR
1. Connecting cylinder and turning the gas on
a Make sure that the black plastic cap is
screwed onto outlet of full cylinder. Ensure valve operates freely by turning anticlockwise to open and clockwise to close. Firmly close valve by turning handwheel clockwise. Remove black plastic cap from valve outlet and store in a safe place for future use.
b Make sure black neoprene washer is in
place on the regulator iniet. Regularly examine, and if unduly compressed or damaged, replace. Do not replace with red branch cap washer.
c Support regulator, screw union nut onto
cylinder valve by turning nut anti-clockwise (left-hand thread). Tighten just over hand tight using Calor Spanner. After fitting the regulator it may have assumed a position out of the horizontal. This is not important. Do not attempt to twist regulator.
d Place cylinder in cabinet so that the cylin-
der valve is facing into the compartment. Open cylinder valve by turning handwheel anticlockwise. Make sure that all connections are gas tight, by brushing with soapy water or liquid detergent (a gas leak will form bubbles). Now refer to the lighting instructions on the heater.
a Close cylinder valve by turning
handwheel clockwise. Check that the heating elements and pilot are out.
b Open back the appliance, remove cylinder
and place close to heater (do not strain hose). Support regulator, use a Calor Spanner to disconnect regulator/ cylinder valve union by turning nut clockwise (left- hand thread). Care must be taken to ensu­re that the outlet connection on the regula­tor is not damaged or strained. Screw black plastic cap onto valve outlet. Place empty cylinder in a safe place.
2. Turning off and disconnecting the cylinder
Where the screw on regulator is used in conjuction with a switch-on adaptor refer to instructions supplied with adaptor.
3
Gas Bottle
Gas Bottle with 15 kg of maximum capacity can be installed. Changing of gas bottle must not be carried out in the presence of a naked flame. Use the gas bottle always in upright position. If a screw on regulator is used ensure that the rgulator washer is present and in good condi­tion - replace if any doubt. To place the bottle in position, remove the rear panel which faces the inside during transport, by unfastening the screws; than put the bottle in position and replace the panel. Do not turn the bottle upside down to use completely its content.
X-Press 1-03-2002 11:54 Pagina 3