Delmhorst D999-FR User manual

www.GlobalTestSupply.com
ENGLISH
CONGRATULATION ON YOUR CHOICE
We are pleased to offer you the nest technology in grain quality control. Your Moisture Tester has been tested through an extensive quality control process to ensure its reliability and accurate results.
To take full advantage of the features and technology in this Equipment, as well as, for better performance during operations, please read this manual.
ENGLISH
THE MANUFACTURER RESERVES THE RIGHT TO MAKE CHANGES WITHOUT PRIOR NOTICE.
1
www.GlobalTestSupply.com
FRMT5617EN
SAFETY INFORMATION
READ THE USER GUIDE BEFORE USING THE EQUIPMENT.
Keep it for future reference
DANGER
Do not install this equipment exposed to weather conditions
Do not repair or replace any parts
Do not break the warranty seal or open the equipment. This action
may damage the equipment; if the warranty seal is damaged the warranty will be terminated.
If you have any questions or problems, call our local authorized service center.
CAUTION
Plug the power supply into a 100-240 VAC, 50-60Hz and 10A.
Do not use extensions or connectors; it may cause overloading in the electrical installation.
Make sure the outlet has the right voltage and frequency for the proper equipment operation
Remove foreign substances, such as dust or water from the contact points using a dry cloth.
Disconnect the plug and clean it with a dry cloth
Be sure the power cord is not twisted, kinked, or crimped to prevent
possible internal wire damage and electrical shock and/or re.
Do not hang or drape the power cord over or on top of the equipment.
Do not pull or bend the power cord with excessive strength.
Do not twist or tie the power cord.
Do not touch the charger with wet hands.
This may cause electric shock
2
www.GlobalTestSupply.com
Always unplug the product holding the charger rmly and pulling out from the outlet.
Damage to the power cord may cause an electric shock or re.
Do not modify the charger supplied with the equipment.
Do not allow liquids to come into contact with electrical parts of the equipment.
Use care when handling the equipment. Any misuse, such as dropping, tossing or throwing, can potentially damage the load cell. During the measurement, do not move the equipment.
Avoid using cell phones, radio or other radio-frequency products near the equipment during the measurement. It may affect the accuracy of the reading.
Do not use sharp objects to interact with the touchscreen display.
• Using sharp objects can damage the display, it is considered misuse,
and the warranty will be terminated.
• It is recommended to use nger touch or non-tipped objects on the
display.
• The display recognizes the press of a nger even with gloves.
• The display does not support multi-touch
ENGLISH
Do not use the moisture tester connected to the power supply. It may affect the measurement results.
3
www.GlobalTestSupply.com
FRMT5617EN
INDEX
GENERAL INFORMATION _______________________________________ 5 KNOWING YOUR MOISTURE TESTER ____________________________ 5 TECHNICAL SPECIFICATIONS __________________________________ 6 SETUP _________________________________________________________ 6
UNPACKING THE EQUIPMENT _________________________________ 6 PACKAGE CONTENTS ________________________________________ 6 INSTALLATION GUIDANCE ____________________________________ 8
QUICK GUIDE TO MEASUREMENT ______________________________ 6 FIRST USE ______________________________________________________ 7
STARTUP PROCESS ___________________________________________ 8 SELECT LANGUAGE __________________________________________ 9 USER NAME __________________________________________________ 9 COMPANY NAME _____________________________________________ 9 CHARTS SELECTION __________________________________________ 9 TERMS OF USE _______________________________________________ 9 AUTO TEST __________________________________________________ 9 CHARTS SELECTION __________________________________________ 9
DAILY USE ____________________________________________________10
TURNING ON THE EQUIPMENT _______________________________ 10 SELECT THE USER ___________________________________________ 10 AUTO TEST __________________________________________________ 10 MAIN SCREEN _______________________________________________ 11 HOME SCREEN ______________________________________________ 12 SAMPLE ANALYSIS ___________________________________________ 12 RESULTS SCREEN ____________________________________________ 13 CHANGING THE CHART ______________________________________ 14 CUSTOM CHART ____________________________________________ 14 SENDING THE RESULT THROUGH WIRELESS COMMUNICATION _ 14 SENDING THE RESULT THROUGH QR CODE ___________________ 15 SETTINGS ___________________________________________________ 15 LAST RESULTS _______________________________________________ 15 LOG ________________________________________________________ 15
MAINTENANCE _______________________________________________16
CLEANING THE EQUIPMENT _________________________________ 16 REPLACING THE CHARGER ___________________________________ 16 ANNUAL MAINTENANCE _____________________________________ 16
TROUBLESHOOTING __________________________________________ 17 TECHNICAL ASSISTANCE ______________________________________18
4
www.GlobalTestSupply.com
GENERAL INFORMATION
38,2 cm
15,1 in
12,0 cm
4,7 in
DUMP
CELL
ON/OFF
20,4 cm
8,0 in
MAIN HOUSING
POWER SUPPLY
PORT
Designed to provide fast and accurate results, the instrument also has a simple and intuitive operating interface, offering the user a color display with touchscreen for easy interaction with the equipment.
Built to meet or exceed the accuracy, security and performance demands for grain moisture tester as described in the NIST (National Institute of Standards and Technology) Handbook 44. In addition, the equipment comes loaded with the USDA and CGC calibration charts.
KNOWING YOUR MOISTURE TESTER
ENGLISH
5
5
www.GlobalTestSupply.com
FRMT5617EN
TECHNICAL SPECIFICATIONS
Charger Power Source From 100 to 240 VCA (50 to 60Hz)
Equipment Power Source 5 VCC - 2A
Battery Usage life 8 hours of continuous use
Recharge Time (with the equipment in off mode)
Grain Temperature Range
Operating Temperature Range
Temperature Difference between equipment
and grain
Equipment heating and stabilization time . 5 minutes
Equipment Dimension (Width x Length x Height)
Approximate Weight (without package) 1,4 kg / 3 pounds
2 hours and 30 minutes
From -20°C to 70°C From -4°F to 158°F
From -20°C to 70°C From -4°F to 158°F
+-10 °C +-18°F
12cm x 20,4cm x 38,2cm
4.7 in x 8 in x 15.1 in
SETUP
UNPACKING THE EQUIPMENT
Carefully, unpack your moisture tester and in case of damaged or malfunction, return the equipment in the original package. Please, contact your customer support.
PACKAGE CONTENTS
• 01 Moisture Tester
• 01 Dump cell
• 01 Charger
• 01 User Guide
• 01 Warranty term
• 01 Carrying Case
INSTALLATION GUIDANCE
Place the Moisture tester on a at, rm and vibrations free surface.
6
www.GlobalTestSupply.com
QUICK GUIDE TO MEASUREMENT
1. Make sure the equipment is on a level surface.
2. Press the power button in the equipment for 3 seconds.
3. Select the user.
4. Press the magnier glass button and choose the chart.
5. Place the dump cell inside a proper container, like a tray, and overll it with the sample you want to measure the moisture of. With a straight edge, remove the excess. The level of the grain sample in the dump cell must be done in a constant and controlled way.
6. Dump the sample into the grain cell
ENGLISH
7. The moisture result appears on the screen. If needed or desired, remove the sample and repeat the process from the step 5.
Moisture (%)
TW (only for reference)
Temperature
7
www.GlobalTestSupply.com
FRMT5617EN
12,0 cm
4,7 in
CHAVE LIGA/DESLIGA
20,4 cm
8,0 in
CARENAGEM
FIRST USE
When you turn on the equipment for the rst time, you can select the preferences. This is the only time you need to enter this information, with the following information:
1. Choose your language
2. How you want to be called
3. Company Name
4. Commodity selection
5. Acceptance of the use terms
6. Self-Test
7. Grain Chart Calibration selection
If needed, the items 1, 4 and 7 can easily be changed by accessing the CONFIG option.
STARTUP PROCESS
Make sure that the equipment is installed in accordance with this document.
Press and hold the on/off button for 3 seconds
You will hear two beeps.
8
www.GlobalTestSupply.com
SELECT LANGUAGE
Choose the language.
USER NAME
Type the user name.
COMPANY NAME
Type the company name
GRAIN CHART CALIBRATION SELECTION
Select the chart group
TERMS OF USE
Using the arrows, scroll down the term of use
Click on the check box icon and press NEXT.
SELF-TEST
This step checks all the components and parameters of the software, for a proper operation.
If the equipment requires, follow the steps:
ENGLISH
Place the empty dump cell on the grain cell
Press OK
Remove the dump cell
Press OK
CHARTS SELECTION
Select the Grain Chart Calibration, the equipment will automatically set all the equation for that specic commodity that you selected.
This completes the startup process and the equipment is ready For use. The device will then go to the HOME screen.
9
www.GlobalTestSupply.com
FRMT5617EN
DAILY USE
After you startup, the equipment will have a shorter and simple start. With only two steps:
1. Select the User Name
2. Self-Test
TURNING ON THE EQUIPMENT
Make sure that the equipment is installed in accordance with this document. Press and hold the on/off button for 3 seconds, you will hear two beeps, place the dump cell on the grain cell.
SELECTING THE USER
This is the rst screen of the equipment
Press to use the same user name.
Press to replace the user name.
This button is only for technician access.
The equipment auto save the last user name.
SELF-TEST
If needed the equipment will ask to verify the load cell, please follow the instruction in the screen
If an error occur, please, restart the process, pressing the TRY AGAIN button.
10
www.GlobalTestSupply.com
DAILY USE
HOME SCREEN
1
2
3
HOME screen. This option
will do the moisture reading.
1
Top 5 quick access. You can choose among the 5 most
2
used grain chart
CONFIG screen. You can access all the equipment
3
conguration
4
8
5
7
6
Equipment time. Military
6
time (24h format)
Equipment interface
7
(message) with the user
When you choose the average
reading, all the partial results
8
will be displayed here.
Battery Level
9
9
ENGLISH
Grain Chart Name
4
Screen title
5
11
FRMT5617EN
www.GlobalTestSupply.com
DAILY USE
HOME SCREEN
This is the home screen. If needed, you can add the sample number and vehicle license plate in the icon on the top right.
Type the sample number and press NEXT
Type the license plate and press SAVE
You will notice that the icon will disappear
and the information saved.
For each measure is necessary to insert the info again. To remove or change, leave the
HOME screen by clicking , or .
SAMPLE ANALYSIS
To do the moisture reading, follow the steps:
*
**
*Grain Shell (Not included, can be bought separately)
** Tray ((Not included, can be bought separately)
www.GlobalTestSupply.com
• Place the dump cell in an appropriate container, like a tray.
• Fill the dump cell with the grain sample, until overow.
• With a straight edge, remove the excess. The level of the grain sample in the dump cell must be done in a constant and controlled way
• Place the dump cell on the grain cell
• Select the correct chart
• Dump the sample into the grain cell
• Immediately remove the empty dump cell
After the procedure, the equipment will show the result screen.
12
DAILY USE
RESULT SCREEN
The moisture results shows on the screen. To repeat the process, remove the sample from the grain cell. Automatically, the equipment returns to the HOME
SCREEN.
ENGLISH
1
2
Moisture content inside the
1
grain sample
Grain Sample Temperature
2
Grain Weight (only for reference)
3
4
6
5
3
Send the result to your
6
smartphone using the MOTOMCO QR CODE reader app.
Grain Chart Name
4
Wirelessly send the info to your
5
smartphone.
www.GlobalTestSupply.com
13
FRMT5617EN
DAILY USE
CHANGING THE CHART
The TOP 5 screen shows the last ve selected charts.
Click in the grain chart that you want. If the one you are looking for is not listed, click on the magnier icon named OTHERS. If you have a custom grain chart, click in CUSTOM.
Choose the desired grain chart by clicking on it. Use the arrows on the right side of the screen to scroll-down all the options. When you choose the desired chart, the equipment will return to the HOME screen.
CUSTOM CHARTS
Please contact the manufacturer to nd out how to get a customized grain chart in your equipment. Once installed on your device, look for it in the CUSTOM group.
SENDING THE RESULT THROUGH WIRELESS COMMUNICATION
Your Moisture Tester can wirelessly communicate with your smartphone. It will send the moisture reading from your equipment to your smartphone.
1. Download the 999-FR NEW app on the AppStore or Google Play.
2. Open the app and turn on the equipment
3. Press “SCAN” on the app.
4. Click on the serial number that you want to synchronize. Now, your equipment and your smartphone are connected.
5. Do the measurement or send the result through PREVIOUS RESULT
6. Share the result through your smartphone.
14
www.GlobalTestSupply.com
DAILY USE
20,4 cm
8,0 in
SENDING THE RESULT THROUGH QR CODE (Optional)
Your Moisture Tester can generate QR CODES from the moisture readings. Follow the steps to read and share it.
1. Download the APP MOTOMCO QRCODE READER on the App Store or GooglePlay.
2. Open the app and turn on the equipment.
3. Do the moisture measurement and click on the icon
4. Read the QR CODE with the app.
5. Share the results through your smartphone..
Note: QR Code is registered trademark of DENSO WAVE INCORPORATED.
Android and GooglePlay are registered trademarks of Google Inc.
SETTINGS
On the settings screen you have access to choose: TW units, language, moisture average readings, last results, Charts per Country, temperature, time and others. To access or change, just click on the respective icon.
LAST RESULTS
Click on the icon to access the last results.
LOG
By clicking on this icon, you have access to all the errors, access and changes on the equipment.
ENGLISH
CHARGING THE BATTERY
To charge the equipment please follow the steps:
1. Plug the charger in the outlet, after plug the micro USB in the equipment
2. The icon will appear in the top corner of the screen, when charging.
3. Don’t use the equipment during the charging of the battery.
15
www.GlobalTestSupply.com
FRMT5617EN
MAINTENANCE
The equipment is factory calibrated with a Manufacturer Standard Tester, which goes under periodic verication to assure that it meets the requirements and standards dened by USDA and CGC.
CLEANING THE EQUIPMENT
Turn the equipment off and unplug it from the outlet. The presence of foreign material inside the grain cell directly affects the equipment accuracy.
• It is recommended to clean the accessible parts with a damp soft cloth.
• Be careful when cleaning the internal side of the grain cell to avoid damage the equipment
• The use of alcohol or other chemicals can damage the equipment
ANNUAL MAINTENANCE
We strongly recommend sending the equipment for the yearly maintenance to assure its accuracy, where it will be calibrated, updated and fully checked. For the maintenance, please place your equipment in the original box, with all accessories and send to the manufacturer.
16
www.GlobalTestSupply.com
TROUBLESHOOTING
An error occurs when an abnormal event occurs. Please, rst check if the equipment is installed according to the instructions.
Screen Message Probable Cause Corrective Action
ENGLISH
Oops, I don’t have any charts installed!
Click on Search and select a chart.
Let´s try again ? I couldn’t stabilize the
temperature.
Let´s try again ? I couldn’t stabilize the
weight.
An error happened with result’s digital signature, the measurement does not have any legal value. The result will not
be transmited to a system or printed.
(User name) the result was outside the
moisture range
(User name) checked the machine is
inclined, please leave it on a at surface
No Charts Installed Select the Grain Chart.
Foreign Material in the
grain cell
Unstable Base
RF presence
System Failure
Moisture out of the range
Uneven Equipment
Clean the grain cell or remove any foreign material inside the grain
cell
Check the use condition of the equipment
Restart the equipment and do the moisture measure
Make sure your sample is compatible with the
selected chart
Place the equipment on a at surface
Please, contact our Customer Support for any error that display and are not
listed.
17
www.GlobalTestSupply.com
FRMT5617EN
Loading...