Della 048-TL-WAC6K, 048-TL-WAC8K, 048-TL-WAC10K, 048-TL-WAC12K Operating instructions

048-TL-WAC6K 048-TL-WAC8K 048-TL-WAC10K 048-TL-WAC12K
NOTICE:
If your package is missing parts or you are having issues with assembly, please call Della directly at 1-800-863-4143. The Della customer service team will address any questions or concerns you may have. Have this manual open and ready for reference.
CUSTOMER SERVICE:
1
manufacturer@dellaproductsusa.com
www.dellaproductsusa.com
INTRODUCTION
IMPORTANT SAFETY INSTRUCTION ...........................................................................
ELECTRICAL REQUIREMENTS
PACKING LIST ............................................................................................................
INSTALLATION & ASSEMBLY INSTRUCTIONS ..............................................................
USING YOUR AIR CONDITIONER ................................................................................
OPERATING YOUR AIR CONDITIONER
CARE AND CLEANING ................................................................................................
TROUBLESHOOTING .................................................................................................
...................................................................................
........................................................................
1
2
3
4
9
11
12
13
1
(6K-8K) 0-8 amps (10K-12K) 0-12 amps
(6K-8K) 10-amp
(10K-12K) 15-amp
2
TWC-06CR/UH (ES) & TWC-08CR/UH (ES)
3
FIG. 1
8
EXTERIOR WALL
INTERIOR
WALL
STOOL SILL
OFFSET
FIG. 2
0
EXTERIOR WALL
INTERIOR
WALL
STOOL SILL
OFFSET
4
(Only used for 6K/8K)
5
REWORD: Top Rail and Sliding Panels at each side are offset to provide the proper pitch of 5/16" to the rear of the air conditioner.
3
FIG. 3
FIG. 4
FIG. 5
6
Keeping
(It is suggested to keep a downward angle so accumulated rain water can drain out from the backside of the unit.)
FIG. 6
FIG. 7
FIG. 10
FIG. 11
FIG. 8
FIG. 12
FIG. 13
FIG. 9
7
FIG. 14
8
1
AUTO SPEED
WIFI
WIFI Symbol*
9
8
NOTE: * means only available for WIFI modes, For more information, please see the WIFI manual.
AUTO MODE
7
5
6
4
Cool Mode: The cooling function allows the air conditioner to cool the room and
air humidity at the same time
and reduces the
. Press the MODE button to activate the cooling function. To optimize the function of the air conditioner, adjust the temperature and the speed by pressing the button indicated. Dry Mode: This function reduces the humidity of the air to make the room more comfortable. Press
2
MODE button to set the DRY mode. An automatic function of alternating cooling cycles and air fan
3
is activated.
Fan Mode:
conditioner is ventilated.
This function works only when the air
Press MODE button to set the FAN mode. With pressing FAN SPEED button the speed changes in the following sequence: Hi, Med and Lo in FAN mode. The remote control also
the speed that was set in the previous mode
stores
of operation. Auto Mode: In AUTO mode the unit automatically chooses the fan speed and the mode of operation (COOL,DRY or FAN).In this mode the fan speed and the temperature are set automatically according to the room temperature (tested by the temperature sensor which is incorporated in the indoor unit.).
1. When the timer is not in use,
Digital Display:
the operation mode and the set temperature will be display. Time will be displayed under the timer setting.
and Button:2. Use these buttons on the control panel and remote to increase or decrease the Set Temperature or Timer. Temperature range: 61 ~88 or 16 ~31 .
3. Turn the air conditioner on and
Power Button:
off.
Press the mode button to cycle
4. Mode Button: through the various modes: Cool, Dry, Fan and Auto.
Use these buttons on the control
5. Timer Button: panel and remote to set the Timer. Timer Off: The timed stop is programmed by pressing TIMER button. Set the rest time by pressing the button or until the rest time displayed is to your then press TIMER
liking
button again. Timer On: When the unit is off, press TIMER button , set the temperature with pressing the button or . Press TIMER button , set the rest time with
a second time
pressing the button or . Press TIMER button , confirm the setting, then
automatically switch on and will show on the display.
a third time will
Note: It can be set to automatically turn off or on in
0.5-24 . Each press of the
hour increments
buttons will increase or decrease the timer. The Timer can be set in 0.5 hours increment below 10 hours and 1 hour increment for 10 hours or above. The SET light will turn on while setting. To cancel the function, press the TIMER button
set
again.
9
When the unit is in ECO mode, the
6. Eco Button: light will turn on. In ECO mode, the unit will turn off once the room is cooled to the user set temperature. Fan will also be off at this point. The unit will turn back on when the room temperature rises above the user set temperature.
Before the compressor , starts the fan motor will
run for a while, then it will stop for a while, and will repeat to provide a much more comfortable feeling and save energy.
Press the SLEEP button, the Sleep
7. Sleep Button:
Light will be on , and
display lights will turn off.
for 10 seconds then all of the
In SLEEP mode, the air­conditioner will automatically adjust the tempera­ture and fan speed to make the room more comfor­table during the night. The set temperature will
automatically raise by 1 or every 30-60 minutes
and at most change six times until the set temperature is .
81 or 82
10.
To direct the airflow, use the
Directional Louvers:
horizontal wheel to control the horizontal direction
and use the air deflectors to control the vertical
direction.
horizontal wheelair deflector air deflector
Press the FAN SPEED button
8. Fan Speed Button: to choose the fan speed options. You can choose
Hi, Med, Lo or auto speed in COOL mode
or
choose Hi, Med, Lo in FAN mode.
9.
When the Filter Check light is off,
Filter Button:
it is to press the Filter Check button.
not necessary
When the Filter Check light is on, can turn off
you
the light by pressing the Filter Check button. After the fan motor works for 500 total hours, the Filter Check light will turn on to remind the user to clean the filter.
10
1
3
4
5
6
3
2
7
8 9
10
Use these buttons on the control panel
5. Timer: and remote to set the Timer. Timer Off: The timed stop is programmed by pressing TIMER button. Set the rest time by pressing the button or until the rest time displayed is to your then press TIMER button again. Timer On: When the unit is off, press TIMER button first time, set the temperature with pressing the button or . Press TIMER button a second time, set the rest time with pressing the button or . Press TIMER button a third time, confirm the setting, then
automatically switch on and will show on the display.
Note: It can be set to automatically turn off or on in 0.5-24 hours. Each press of the buttons will increase or decrease the timer. The Timer can be set in 0.5 hours increment below 10 hours and 1 hour increment for 10 hours or above. The SET light will turn on while setting. To cancel the function, press the TIMER button again.
a
set
liking
will
1. the air conditioner on and off.TurnsPower:
2. Press the COOL button to COOL mode.Cool:
and :3. Use these buttons on the control panel and remote to increase or decrease the Set Temperature or Timer. Temperature range: 61 ~88 or 16 ~31 .
4. Sleep:
Press the SLEEP button, the Sleep Light will be on , and
display lights will turn off.
conditioner will automatically adjust the tempera­ture and fan speed to make the room more comfor­table during the night. The set temperature will automatically raise by 1 or 2 every 30-60 minutes and at most change six times until the set temperature is .
for 10 seconds then all of the
In SLEEP mode, the air-
81 or 82
In AUTO mode the unit automatically
6. Auto Mode: chooses the fan speed and the mode of operation (COOL,DRY or FAN).In this mode the fan speed and the temperature are set automatically according to the room temperature (tested by the temperature sensor which is incorporated in the indoor unit.).
Press the FAN SPEED button to
7. Fan Speed: choose the fan speed options. You can choose Hi, Med, Lo or auto speed in COOL mode and Hi, Med, Lo in FAN mode.
By pressing the DISPLAY button, it will switch
8. Display:
off/on all lights on the LED display.
When the unit is in ECO mode, the
9.
Eco:
light will turn on. In ECO mode, the unit will turn off once the room is cooled to the user set temperature. Fan will also be off at this point. The unit will turn back on when the room temperature rises above the user set temperature. Before the compressor , starts the fan motor will
run for a while, then it will stop for a while, and will repeat to provide a much more comfortable feeling and save energy.
11
Fan Only:
Press the Fan Only button to
10. FAN ONLY mode.
switch to
15
FIG. 15
12
13
14
Loading...
+ 36 hidden pages