3
SAFETEY OPERATION
Please exercise caution when using this air purifier or any other electrical device! This manual describes the safety precautions which should be observed in relation to your air purifier. Please review carefully BEFORE using this product.
High performance DC fan, low energy consumption, durable use Built-in smart gas and dust sensor, automatic sensing and adjust airflow speed Sleep mode, quite and comforting Dust collector cell, easy to clean, never needs to be replaced Multiple air inlets design effective in purification coverage Large volumes of air rapidly circulate and purify air Convenient remote control, six operating modes for easy control High performance filter effectively removes PM2.5 and extra fine particles of 0.1 – 0.3 microns Excellent dust removal rate up to 99.97% Effectively eliminate odor and smoke to freshen the air UV LED and catalyst technology effectively sterilize and kill bacteria
Features
2
CAUTION
The voltage rating for air purifiers sold in the USA, Japan and Canada is AC100-120V, 50/60Hz and in Europe is AC 230V, 50Hz. Using the wrong current may result in unit damage, electrical shock or fire.
Do NOT operate your air purifier while it’s covered with fabric, plastic or other materials. This can obstruct air flow, damage the unit and may pose a fire hazard.
Do NOT attempt to dismantle, repair or modify this device on your own. Doing so could result in electrical shock or damage to the unit. In the event of malfunction, contact an authorized maintenance facility.
Do NOT operate your air purifier in places where flammable, explosive or otherwise combustible materials are stored.
Do NOT place the unit in direct sunlight or near lit fireplaces, furnaces, ovens or other high temperature objects. Doing so can damage the air purifier and may pose a fire hazard. Avoid operating the unit when the air temperature exceeds 104 F/40 C.
Do NOT place foreign objects in air purifier which can damage the unit or result in electrical shock. To avoid machine damage , injury and accidents, Do Not allow children to touch or play with this device.
To avoid distortion or interference, your air purifier should be placed at least three (3) feet from computers, televisions and radios.
For safety reason and to avoid the risk of electrical shock and/or fire, unplug your air purifier from the electrical outlet under each of the following conditions
If the electric cord is damaged in any way, it must be replaced by the manufacturer or a qualified service center. NEVER operate a unit with a damaged electric cord. Doing so presents a serious risk of fire and/or electrical shock.
Clean sign
Control panel
Air Inlet
Air Outlet
Back View
Handle
Gas Sensor
Dust Sensor
Dust Collector Cell
DC FAN
UV LED
HEPA Filter
TiO2 Filter
MAJOR COMPONENTS
Air Inlet
Handle
To prevent the possibility of electrical shock or short-circuiting your air purifier, Do NOT place the unit in or near the shower, bathtub or other places where water seep into and damage the unit.
Pre-filter
Front cover
RATED
VOLTAGE
DO NOT
DISMANTLE
AVOID HEAT
SOURCES
AVOID
DIRECT
SUNLIGHT
DO NOT TAMPER
KEEP AWAY
FROM WATER
DO NOT COVER
DO NOT
DISTORTION
DAMAGED
CORD
WHEN TO
UNPLUG
·When cleaning or servicing the air purifier or replacing filters
·When you will not be using your air purifier for an extended time periodTraveling
·When moving the unit from one location to another
When the air purifier or power cord gets heated,
burned smell or weird noise
When thundering or lightening
·
·
Activiated Carbon Filter
Ion Generator
PREPARATIONS BEFORE USE
5
Operation
Locate the unit on a solid surface. Be sure the air inlet/outlet is not blocked by other objects. (At least 30cm clearance on the sides) It is best to locate the unit where it will be out of any children's play area. Before plugging in the unit, please open the windows in the area where you will be using the unit. Ventilate the area for 2-3 hours if possible. Once the area has been ventilated, close the windows and plug in the unit.(Figure 1) Switch on the unit and start to operate under AUTO mode. Once started, the color of CLEAN SIGN will change alternately for 1 minute (as it memorizes the existing fresh air condition), and then CLEAN SIGN will indicate current air quality. (Figure 2) After plugging in, the unit sensor will sample the air and retain a memory of the existing indoor air condition. (The existing indoor air condition will be input as “Clean Air”). Note: Whenever the unit is unplugged, all memorized content will be erased.
F1
For initial use or re-operate the unit after unplug, the sensor need to be pre-heated for 3-5 minutes and will not response during this period. Besides, if the current air quality is not good (such as smoke, cosmetics or alcohol is presented), please ventilate and freshen the air before closing windows. Re-operate the unit after long period unused, the sensitivity of the sensor may decrease, it will revert to normal after 1-2 days operation.
Caution
F2
PREPARATIONS BEFORE USE
4
For initial use or filter replacement, please remove the plastic bag of filter. If the plastic bag is not removed, the unit may operate noisily.
USES OF FILTERS
The purifying efficiency will decrease if the air purifier operates without filters. For initial use, new filters may emit a little smell; the smell will dissipate naturally after operating for more than one day. Please close the windows or door in the area during operation. For long time use, please ventilate periodically. If the smell is heavy in the area(such as cooking), please ventilate the area and then remove the rest of smell by unit. Otherwise, the purifying efficiency may decrease and the life span of activated carbon filter will reduce.