Page 1
PACKAGES FOR
LINUX Version 7.3
DELL UPDATE
Release Notes
Page 2
Release Type and Definition
This Readme contains updated information for your "Dell Update
Packages for Linux Operating Systems User's Guide" and any other
technical documentation included with the Dell Update Packages
for Linux.
Version
7.3
Release Date:
July 2013
Previous Version
7.2
Importance
RECOMMENDED: Dell recommends applying this update during your next scheduled update cycle. The
update contains feature enhancements or changes that will help keep your system software current and
compatible with other system modules (firmware, BIOS, drivers and software).
CONTENTS
• MINIMUM REQUIREMENTS
• CRITICALITY
• UPDATE PACKAGES: SUPPORTED COMPONENTS
• KNOWN ISSUES
Platform(s) Affected
Dell Update Packages offer ease and flexibility for updating the
system software on Dell PowerEdge systems. Update Packages are
available for the following software components:
• System BIOS
• System firmware, also known as the Embedded Systems Management (ESM)
• firmware
• Dell Remote Access Controller (DRAC)/Integrated Dell Remote Access Controller(IDRAC)
firmware, which also includes
• Embedded Remote Access (ERA) firmware
• Integrated Dell Remote Access Controller(IDRAC) firmware
• PowerEdge Expandable RAID Controller (PERC) firmware and driver
Page 3
• Cost -Effective RAID Controller (CERC) firmware and driver
• Software RAID Controller firmware and driver
• SEP firmware
• IDE Controller drivers
• Baseboard Management Controller (BMC) firmware
• SCSI Backplane (BP) firmware
• SAS BP firmware
• SAS Expander firmware
• SSD firmware
• SED firmware
• SAS HDD Firmware
• SAS Controller firmware
• PowerVault 100T firmware
• PowerVault 110T firmware
• PowerVault MD1120 firmware
• PowerVault MD1200 firmware
• PowerVault RD1000 firmware
• Broadcom Network Adapter driver
• Intel Network Adapter driver
• QLogic Network Adapter driver
• Emulex Network Adapter driver
• Power Supply firmware
• Broadcom Network Adapter Firmware
• Intel Network Adapter Firmware
• QLogic Network Adapter Firmware
• Emulex Network Adpater Firmware
• OpenManage Server Administrator updates
• Mellanox Network Adapter Firmware
What’s New
• The Update Packages support Dell systems running the following Linux operating systems:
• Red Hat Enterprise Linux 5.8 (32 -bit)
• Red Hat Enterprise Linux 5.8 (32 and 64 -bit)
• Red Hat Enterprise Linux 5.9 (32 -bit)
• Red Hat Enterprise Linux 5.9 (32 and 64 -bit)
• Red Hat Enterprise Linux 6.3 server (64 -bit)
• Red Hat Enterprise Linux 6.4 server (64 -bit)
• SUSE Linux Enterprise Server 10 SP4 (32 and 64-bit)
• SUSE Linux Enterprise Server 11 SP2 (32 and 64-bit)
Page 4
• VMware ESX Server version 4.1 Update 3
• Citrix Xen Server 6.1
• Citrix Xen Server 6.2
NOTE: For the latest information about the various Dell systems
and operating systems that Dell Update Packages are supported on,
see the "Dell Systems Software Support Matrix" on the Dell Support
website at " www.dell.com/openmanagemanuals
NOTE: Update Packages may also be applied in a pre-operating system
environment that uses the Embedded Linux (ELI) through the
Dell OpenManage Deployment Toolkit (DTK).
".
CRITICALITY
2 - Recommended
It is recommended that you apply this update during your next
scheduled update cycle. The update contains feature enhancements or
changes that will help keep your system software current and
compatible with other system modules (firmware, BIOS, drivers, and
software).
UPDATE PACKAGES: SUPPORTED COMPONENTS
Update Packages currently do not support every system component type.
Dell will continue to make Update Packages available on additional
devices in future.
This release of Update Packages supports updates to the devices
listed in the following table.
Component Type Supported Components
----------------------------------------------------------------------
BIOS BIOS
----------------------------------------------------------------------
DRAC firmware DRAC 5, iDRAC6, iDRAC7
----------------------------------------------------------------------
RAID Firmware and drivers
PERC H200,
PERC S300 Adapter,
PERC 5/E, PERC 5/i, SAS 5/i,
SAS 5/iR Adapter, SAS 5/E, SAS 5/iR,
SAS 6/iR, SAS 6/iR Adapter, PERC 6/E,
PERC 6/i, PERC 6/i Adapter, CERC6/i
PERC H310 Adapter,PERC H310 Mini Blade,
PERC H710P Mini Blade,PERC H810 Adapter,
Page 5
PERC H710P Adapter,PERC H710 Mini Monolithic,
PERC H310 Mini Monolithic,PERC H710 Adapter
H710P Mini Monolithic,PERC H710 Mini Blade
PERC H700 Adapter,PERC H700 Modular,PERC H800
Adapter,
PERC H700 Integrated
----------------------------------------------------------------------
BMC firmware BMC
----------------------------------------------------------------------
SCSI BP firmware BP
----------------------------------------------------------------------
SAS BP, SEP firmware BP
----------------------------------------------------------------------
Storage enclosure PowerVault MD1000,
PowerVault MD1120, PowerVault MD1200,
PowerVault MD1220, PowerVault MD3000
----------------------------------------------------------------------
Tape drives firmware PowerVault 100T DDS4,
PowerVault 110T DAT72,
PowerVault 110T LTO1,
PowerVault 110T LTO2,
PowerVault 110T LTO2-L,
PowerVault 110T LTO3,
PowerVault 110T LTO3-HH,
PowerVault 110T LTO4,
PowerVault 110T SDLT320,
PowerVault 110T DLT VS80,
PowerVault 110T DLT VS160,
PowerVault 110T SDLT
----------------------------------------------------------------------
Removable disk drive PowerVault RD1000 backup firmware
----------------------------------------------------------------------
Network adapter firmware Broadcom NetXtreme family of adapters
Broadcom NetXtreme II family of adapters
Intel PRO PCI-E Gigabit family of adapters
QLogic Network family of adapters
Emulex Network family of adapters
Mellanox ConnectX-3 Dual Port 10 GbE KR Blade Mezzanine Card
Mellanox ConnectX-3 Dual Port 40 GbE QSFP+ Network Adapter
Mellanox ConnectX-3 Dual Port 10 GbE DA/SFP+ Network Adapter
Page 6
KNOWN ISSUES
----------------------------------------------------------------------
For all Dell Update Packages
----------------------------------------------------------------------
• Do not run other applications while executing Dell Update Packages.
• For firmware Dell Update Packages, an update package will not
inventory the device if only a native non-Dell driver is installed.
Therefore, firmware update packages cannot upgrade a device with a
native driver.
• If the following error is displayed,
"Error while loading shared libraries: libstdc++.so.5:
cannot open shared object file: No such file or directory",
install the compatibility libraries from your Linux distribution.
To install the compatibility libraries, use the following command:
"rpm -ivh compat-libstdc++-33-3.2.3-47.3.i386.rpm"
SLES 10 and SLES 11 (all service packs) uses
"libstdc++-33-32bit-3.3.3-11.9.x86_64.rpm"
• If Update Packages stop abruptly due to a power outage or
abnormal termination, perform the following steps:
1. Remove the lock file.
2. Type the following command to do so: "rm -f /var/lock/.spsetup"
3. Run the Update Package again.
• If you see the message, "This Update Package is not compatible
with any of the devices detected on your system", for a supported
device, ensure that you have the latest Dell drivers for
your system from the Dell Support website at "www.support.dell.com.
• Some distributions of Linux may automatically mount a USB flash
drive with the "-noexec" option. This prevents the execution of any
file on that drive, including Dell Update Packages. If you are
Page 7
attempting to run a Dell Update Package from a USB flash drive
under Linux, and are experiencing problems, remount the drive
without the "-noexec" option, or copy the Dell Update Package to a
drive mounted without the "-noexec" option.
• Dell Update Packages do not require new refreshes of existing DUPs
to be reinstalled since the firmware or driver payload does not
change when the DUP is refreshed. A new DUP is available if changes
have been made to the firmware or driver payload.
• If the console terminal displays USB connection status messages,
ignore them as they do not affect the system.
• On all versions of ESX the following the USB Connection message with
errors, these messages can also be ignored. The following shows a
typical message:
Vendor: iDRAC Model: MAS022 Rev: 1.00
Type: Direct-Access ANSI SCSI revision: 02
VMWARE SCSI Id: Supported VPD pages for sdc : 0x1f
VMWARE SCSI Id: Could not get disk id for sdc
VMWARE: Unique Device attached as scsi disk sdc at scsi3, channel 0,
id 0, lun 0
Attached scsi removable disk sdc at scsi3, channel 0, id 0, lun 0
SCSI device sdc: 327680 512-byte hdwr sectors (168 MB)
sdc: Write Protect is on
SCSI disk error: host 3 channel 0 id 0 lun 0 return code = 8000002
Current sd08:21: sense key Data Protect
Additional sense indicates Write protected
I/O error: dev 08:21, sector 1
SCSI disk error : host 3 channel 0 id 0 lun 0 return code = 8000002
Current sd08:21: sense key Data Protect
Additional sense indicates Write protected
Page 8
I/O error: dev 08:21, sector 1
Vendor: iDRAC Model: SECUPD Rev: 0329
Type: Direct-Access ANSI SCSI revision: 02
• DRAC5 updates are not supported on ESX 4.1.
But if you run DRAC5 updates on ESX 4.1, console messages show up asking
for IPMI installations, however later the updates goes through successfully.
• DUPs are designed to run only on a 32-bit environment. To run DUPs
on a pure 64-bit environment, use the Dell YUM repository.
• If you attach VMedia on a system with the iDRAC Firmware version 1.5,
some DUPs may fail to work. To resolve this issue, run the following
command:
racadm config -g cfgRacVirtual -o cfgLCDriveEnable 1
where cfgLCDriveEnable is an option implemented in iDRAC 1.5 with a
default of 0 (disabled)
NOTE : This command enables LCDrive from the iDRAC console or the OS.
If the LCDrive is not enabled, DUPs may not work.
After the DUP update is complete, to ensure the LCDrive is
invisible, run the following command:
racadm config -g cfgRacVirtual -o cfgLCDriveEnable 0
• When you run USC-related DUPs with Citrix Xenserver 5.6.0-x,
you need to set the virtual media in iDRAC to Detach. If you set the
virtual media to Attach, the following error message is displayed:
"Inventory Failure: Secure Copy Failure - The Secure copy function
has failed"
For BIOS updates, the following message is displayed:
"doDepCheck failed"
For other USC access related DUPs (PSU, NIC, SAS, PERC, BackPlane),
the update is successful but the following error message may be
displayed:
Page 9
"… mount: block device /dev/secmasupd-SECUPD is write-protected …
/bin/cp: cannot create regular file …"
• When you try to execute DUPs on a 64-bit RHEL operating system, it
fails to execute since DUP is a 32-bit application. To work around
this issue, manually install the following RPMs:
glibc.i686
compat-libstdc++.i686
libstdc++.i686
zlib.i686
libxml2.i686
• While executing some DUP's on 11G servers and When virtual media is
in attached mode, a window with name SECUPD will popup and close
automatically. Due to this there will be no functionality impact on
DUP. This behaviour is observed across all RHEL OS flavours.
• Linux CLI Options
For options begining with '--', abbrevations are also supported.
----------------------------------------------------------------------
Power Supply Unit (PSU) Dell Update Packages (DUPs)
----------------------------------------------------------------------
After a Successful Power Supply firmware update, the system turns off,
for up to 5 to 10 minutes, and reboots automatically. If you perform a
cold boot (AC Power cycle) during the firmware update, the system does
not boot.
----------------------------------------------------------------------
Unified Server Configurator (USC) Dell Update Packages (DUPs)
----------------------------------------------------------------------
• Lifecycle controller updates require system services to be enabled.
• For the first time, before you attempt to run Driver Package
Diagnostics DUPs, execute the USC DUP.
• If the operating system is installed from "Operating System
Deployment", select "Reboot and Exit" in the USC environment before
Page 10
booting to the operating system. This closes the USC session which
is held for 18 hours. If you do not want to enter the USC and select
"Reboot and Exit", but want to execute the DUPs within 18 hours,
unplug the power supply of the system, wait for 10 seconds, and then
power on the system.
• Due to the USB arbitration services of VMWare ESX 4.1, the USB
devices appear invisible to the Hypervisor. So, when DUPs or the
Inventory Collector runs on the Managed Node, the partitions exposed
as USB devices are not shown, and it reaches the timeout after 15 to
20 minutes. This timeout occurs in the following cases:
• If you run DUPs or Inventory Collector on VMware ESX 4.1, the
partitions exposed as USB devices are not visible due to the USB
arbitration service of VMware ESX 4.1 and timeout occurs. The
timeout occurs in the following instances:
• When you start “DSM SA Shared Service” on the VMware ESX 4.1 managed
node, it runs Inventory Collector. To work around this issue,
uninstall Server Administrator or wait until the Inventory Collector
completes execution before attempting to stop the “DSM SA Shared Service”.
• When you manually try to run DUPs or the Inventory Collector on the
VMware ESX 4.1 managed node while USB arbitration service is running.
To fix the issue, stop the USB arbitration service and run the DUPs
or the Inventory Collector.
To stop the USB arbitration service:
1. Use the “ps aux|grep usb” to check if the USB arbitration
service is running.
2. Use the “chkconfig usbarbitrator off” command to prevent the USB
arbitration service from starting during boot.
3. After you stop the usbarbitrator, reboot the server to allow the
DUPs and/or the Inventory collector to run.
Page 11
Note : If you require the usbarbitrator, enable it manually. To enable
the usbarbitrator, run the command - chkconfig usbarbitrator on.
----------------------------------------------------------------------
12 G BIOS
----------------------------------------------------------------------
• BIOS updates require system services/Lifecycle controller to be enabled.
• If the operating system is installed from "Operating System
Deployment", select "Reboot and Exit" in the USC environment before
booting to the operating system. This closes the USC session which
is held for 18 hours. If you do not want to enter the USC and select
"Reboot and Exit", but want to execute the DUPs within 18 hours,
unplug the power supply of the system, wait for 10 seconds, and then
power on the system.
• BIOS DUP will use LC to update BIOS. BIOS DUP will stage the BIOS
firmware to maser partition and create a SSIB update task, which is
executed by the SSM manager on reboot. The update task in the SSIB
is a call to update wrapper in LC which has BIOS update logic.
----------------------------------------------------------------------
BIOS
----------------------------------------------------------------------
• A BIOS update requires enough free physical memory to load the
entire BIOS image into the physical memory. If there is
insufficient free physical memory available on the system to
load the BIOS image, the Dell Update Package for BIOS may
fail. In this instance, you may attempt running the Dell Update Package immediately after
reboot or after adding more memory. If this does not resolve the issue, update the BIOS using
the diskette method.
• If the above memory limitation occurs on VMware ESX Server, the
problem is because the console operating system available memory is
only 272 MB by default. Increase the console operating system memory
to 800 MB temporarily and perform the firmware update. During ESX
Page 12
Server boot up, perform the following steps to increase the
available memory:
1. While booting, press "e" on the VMware ESX line (Grub option
display screen).
2. Press "e" again on the 'uppermem=' line and edit uppermem=819200.
3. Press "Enter".
4. Press "e" on the kernel line (below the uppermem line).
Edit the kernel line with mem=800M and press “Enter”.
5. Press "b" to boot with these options.
6. Perform the firmware update.
• BIOS update may issue the following kernel messages on the console
and in "/var/log/messages":
dcd***: disagrees about the version of symbol struct_module
dcd***: Unknown symbol get_user_size
dcd***: Unknown symbol put_user_size
Ignore these messages because they do not refer to errors in BIOS
update.
----------------------------------------------------------------------
Dell Embedded Open Manage Server Administrator
----------------------------------------------------------------------
The Dell Update Package for Dell Embedded Open Manage Server
Administrator can only be applied in a pre-operating system environment
that uses the Embedded Linux (ELI) through the Dell OpenManage
Deployment Toolkit (DTK).
----------------------------------------------------------------------
Intel firmware
----------------------------------------------------------------------
The Linux FW DUP file requires DKMS (Version 2.2.x up to 2.2.0.2-1) and
will not install correctly without it. It also requires that the
appropriate kernel sources and the compiler be installed, because the
Page 13
Intel iqvLinux driver must be compiled on the target system.
----------------------------------------------------------------------
Emulex firmware
----------------------------------------------------------------------
Before running the Dell (Emulex) Network firmware DUP ensure that Dell
(Emulex) driver packages are installed on the system.
----------------------------------------------------------------------
DRAC 5 firmware
----------------------------------------------------------------------
• Before updating the DRAC firmware, ensure that the following
conditions are met:
1. USB is enabled
2. IPMI is working properly
3. DRAC Virtual Flash is not in use either by the operating system
or by any other application
• The Linux DUP in this release may not work on RHEL 5. It works on
earlier versions of RHEL. In cases where it does not work, use the
web pack to perform this update.
----------------------------------------------------------------------
Power Supply Unit firmware
----------------------------------------------------------------------
• Power Supply Unit firmware updates can be performed only on Life Cycle
Controller enabled systems.
----------------------------------------------------------------------
All PERC firmware and all SAS firmware
----------------------------------------------------------------------
• Do not run storage controller update packages if the controller is
in use by other applications.
The firmware upgrade may fail if any of the RAID controllers in the
system are performing an I/O background task (consistency
check, background initialization, rebuild, or reconstruction).
Page 14
Allow the background task to complete before attempting to upgrade
the firmware. "Patrol Read" tasks will not affect a firmware
upgrade.
• Linux systems running one or more applications that interact with
SCSI devices in certain ways are known to cause a kernel panic
situation. Therefore, it is recommended that you stop Dell
OpenManage Server Administrator and Dell OpenManage Server
Administrator Storage Management Service before running
storage controller firmware update packages.
To stop the Dell OpenManage Server Administrator service,
run "omconfig system webserver action=stop"
To start the Server Administrator service,
run "omconfig system webserver action=start"
To stop the Server Administrator Storage Management Service,
run "/etc/init.d/dataeng stop"
To start the Server Administrator Storage Management Service,
run "/etc/init.d/dataeng start"
----------------------------------------------------------------------
PowerVault MD1000 firmware
----------------------------------------------------------------------
• The PowerVault update procedure requires the RAID controller to
be in a known good state. If a problem occurs with the RAID
controller during the update procedure, the Update Packages cannot
communicate with the PowerVault system, inventory its firmware
version, or perform the update. (138462)
----------------------------------------------------------------------
PowerVault MD1000 firmware
----------------------------------------------------------------------
• Stop all input/output to the PowerVault MD1000 before running
the PowerVault MD1000 firmware update package.
• WARNING: THE SERVER MUST BE REBOOTED AFTER UPDATING THE FIRMWARE ON
MD1000 ENCLOSURES IN ORDER TO MAINTAIN ENCLOSURE MANAGEMENT. ACCESS
TO THE ENCLOSURES WILL BE LOST IF THE SERVER IS NOT REBOOTED.
• When prompted for reboot after the update, select "Yes".
Page 15
----------------------------------------------------------------------
PowerVault 100T DDS4 firmware and all PowerVault 110T firmware
(110T DDS4, 110T DAT72, 110T LTO1, 110T LTO2, 110T LTO2-L,
110T LTO3-HH, 110T LTO4, 110T SDLT320, 110T LTO3, 110T DLT VS80,
110T DLT VS160, and 110T SDLT)
----------------------------------------------------------------------
• Before executing the firmware update, stop all tape backup
activity and put all scheduled jobs on hold.
• After the firmware update is completed, restart your system for
the updates to take effect.
Note : Tape automation devices are not supported by Dell Update
Packages. Please disconnect or power off such devices before
executing Dell Update Packages.
The tape automation devices are as follows:
1. PowerVault 120T
2. PowerVault 122T
3. PowerVault 124T
4. PowerVault 128T
5. PowerVault 130T
6. PowerVault 132T
7. PowerVault 136T
8. PowerVault 160T
9. PowerVault ML6000
####################################################################
© 2013 Dell Inc.
Trademark s used in this text: Dell™, the Del l logo, Dell Precision™ , OptiPlex™, Lati tude™, PowerEdge™, PowerVault ™, PowerConnect™,
OpenManage™, Eq ual Logic™, Compelle nt™ , KACE™, FlexAddress™, Force10™ and Vostro™ are trademarks of Dell Inc. Intel®, Pentium®,
Xeon®, Core® and Celeron® are r egistered t rademarks of Int el Corporati o n in the U.S. and other countri es. AMD®is a registered trademark and
AMD Opteron™, AMD Phenom™ and AMD Sempron™ are trademarks of Advanced Micro Devices, Inc. Microsoft®, Windows®, Windows
Server®, Internet Explorer®, MS-DOS®, Windows Vista® and Active Directory® are either trademarks or registered trademarks of Microsoft
Corporation in the United States and/or other countries. Red Hat® and Red Hat®E nterprise Linux® are registered trademark s of Red Hat, Inc. in the
United States and/or other countries. Novell® and SUSE® are registered trademarks of Novell Inc. in the United States and other countries. Oracle®
is a registered trademark of Oracle Corporation and/or its affiliates. Citrix®, Xen®, XenServer® and XenMotion® are either registered trademarks or
trademarks of Citrix Systems, Inc. in the United States and/or other countries. VMware®, Virtual SMP®, vMotion®, vCenter® and vSphere® are
registered trademark s or trademarks of VMware, Inc. in t he United Stat es or other countries. IBM® is a registered t rademark of International
Business Machines Corporation.