Dell Storage Center sc100, Storage Center sc120 Owner's Manual

Dell Storage Center
SC100 and SC120 Expansion Enclosure
Owner's Manual
Regulatory Model: E03J, E04J Regulatory Type: E03J001, E04J001
Notes, Cautions, and Warnings
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
Copyright © 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and
intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.
2015 - 07
Rev. A01
Contents
About this Guide.......................................................................................................5
Revision History..................................................................................................................................... 5
Audience................................................................................................................................................ 5
Contacting Dell......................................................................................................................................5
Related Publications..............................................................................................................................5
1 About the SC100/SC120 Expansion Enclosure................................................7
SC100/SC120 Expansion Enclosure Overview.....................................................................................7
SC100/SC120 Expansion Enclosure Monitoring and Diagnostics.......................................................7
SC100/SC120 Expansion Enclosure Front Panel Features and Indicators..........................................7
SC100/SC120 Expansion Enclosure Back Panel Features and Indicators.......................................... 8
SC100/SC120 Expansion Enclosure EMM Features and Indicators.................................................... 9
SC100/SC120 Expansion Enclosure Drives........................................................................................10
2 Replacing SC100/SC120 Components........................................................... 11
Safety Precautions............................................................................................................................... 11
Installation Safety Precautions.......................................................................................................11
Electrical Safety Precautions......................................................................................................... 12
Electrostatic Discharge Precautions............................................................................................. 12
General Safety Precautions........................................................................................................... 12
Pre-Replacement Procedures.............................................................................................................13
Sending Diagnostic Data Using Dell SupportAssist...................................................................... 13
Shutting Down the Storage System and Expansion Enclosures..................................................13
Replacing the Front Bezel................................................................................................................... 13
Replacing Power Supply/Cooling Fan Modules.................................................................................14
Identifying the Failed Power Supply..............................................................................................14
Identifying the Failed Cooling Fan................................................................................................ 16
Replacing a Power Supply/Cooling Fan Module..........................................................................17
Replacing Hard Drives ........................................................................................................................19
SC100/SC120 Expansion Enclosure Drive Numbering................................................................ 19
Identifying the Failed Hard Drive.................................................................................................. 20
Replacing a Hard Drive.................................................................................................................. 21
Replacing an Enclosure Management Module.................................................................................. 23
Identifying the Failed Enclosure Management Module............................................................... 23
Replacing an Enclosure Management Module............................................................................ 24
Replacing Rack Rails............................................................................................................................25
Post-Replacement Procedures.......................................................................................................... 26
Starting Up the Storage System and Expansion Enclosures........................................................26
Sending Diagnostic Data Using Dell SupportAssist......................................................................26
3
3 Troubleshooting SC100/SC120 Components...............................................27
Troubleshooting Power Supply/Cooling Fan Modules......................................................................27
Troubleshooting Hard Drives..............................................................................................................27
Troubleshooting Enclosure Management Modules.......................................................................... 28
Troubleshooting the Control Panel................................................................................................... 28
4 SC100/SC120 Technical Specifications......................................................... 29
Technical Specifications..................................................................................................................... 29
4
Preface
About this Guide
This guide describes how to perform service and maintenance on an SC100/SC120 expansion enclosure.
Revision History
Document Number: DWWC8
Revision Date Description
A00 April 2015 Initial release
A01 July 2015 Updated to include correct version of Expansion Enclosure Overview
Audience
The information provided in this Owner’s Manual is intended for use by Dell end users.
Contacting Dell
Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area.
To contact Dell for sales, technical support, or customer service issues go to www.dell.com/support.
For customized support, enter your system Service Tag on the support page and click Submit.
For general support, browse the product list on the support page and select your product.
Related Publications
The following documentation is available for the SC100/SC120 expansion enclosure.
Dell Storage Center SC100 and SC120 Expansion Enclosure Getting Started Guide Provides information about an SC100/SC120 expansion enclosure, such as installation instructions
and technical specifications.
Dell Storage Center SCv2000 Series Virtual Media Update Instructions Describes how to install Storage Center software on an SCv2000/SCv2020 storage system using
virtual media. Installing Storage Center software using the Storage Center Virtual Media option is intended for use only by sites that cannot update Storage Center using standard methods.
Dell Storage Center Software Update Guide Describes how to upgrade Storage Center software from an earlier version to the current version.
Dell Storage Center Command Utility Reference Guide Provides instructions for using the Storage Center Command Utility. The Command Utility provides a
command-line interface (CLI) to enable management of Storage Center functionality on Windows, Linux, Solaris, and AIX platforms.
5
Dell Storage Center Command Set for Windows PowerShell Provides instructions for getting started with Windows PowerShell cmdlets and scripting objects that
interact with the Storage Center via the PowerShell interactive shell, scripts, and PowerShell hosting applications. Help for individual cmdlets is available online.
Dell Storage Client Administrator’s Guide Provides information about the Dell Storage Client and how it can be used to manage a Storage
Center.
Dell Enterprise Manager Administrator’s Guide Contains in-depth feature configuration and usage information
Dell TechCenter Provides technical white papers, best practice guides, and frequently asked questions about Dell
Storage products. Go to: http://en.community.dell.com/techcenter/storage/.
6
1
About the SC100/SC120 Expansion Enclosure
An SC100/SC120 expansion enclosure provides expansion storage for an SCv2000/SCv2020 storage system.
The SC100/SC120 connects directly to the SAS ports on the back of the storage system.
SC100/SC120 Expansion Enclosure Overview
The SC100 is a 2U expansion enclosure that supports up to 12 3.5inch hard drives installed in a four column, three-row configuration. The
SC120 is a 2U expansion enclosure that supports up to 24 2.5inch
hard drives installed vertically sidebyside. An SC100/SC120 expansion enclosure ships with two redundant power supply/cooling fan modules and
two redundant enclosure management modules (EMMs).
SC100/SC120 Expansion Enclosure Monitoring and Diagnostics
The Storage Center OS generates alert messages for temperature, I/O module, fan module, disk, and power conditions for Storage Center components. Use the Dell Storage Client to view these alerts.
The SC100/SC120 also has LED indicators to notify you of a possible problem with the expansion enclosure.
NOTE: Dell OpenManage Server Administrator is not available for the SC100/SC120.
SC100/SC120 Expansion Enclosure Front Panel Features and Indicators
The SC100/SC120 front panel shows the expansion enclosure status and power supply status.
Figure 1. SC100 Front-Panel Features and Indicators
About the SC100/SC120 Expansion Enclosure
7
Figure 2. SC120 Front-Panel Features and Indicators
Item Name Icon Description
1 Expansion enclosure
status indicator
Lights when the expansion enclosure power is on.
Off: No power
On steady blue: Normal operation
Blinking blue: Indicates that Storage Center is
identifying the enclosure
On steady amber: Expansion enclosure is turning on or
was reset
Blinking amber: Expansion enclosure is in the fault
state.
2 Power supply status
indicator
Lights when at least one power supply is supplying power to the expansion enclosure.
Off: Both power supplies are off.
On steady green: At least one power supply is providing
power to the expansion enclosure
3 Hard drives
Dell Enterprise Plus Drives
SC100: Up to 12 3.5-inch hard drives
SC120: Up to 24 2.5-inch hard drives
SC100/SC120 Expansion Enclosure Back Panel Features and Indicators
The SC100/SC120 back panel provides controls to power up and reset the expansion enclosure, indicators to show the expansion enclosure status, and connections for back-end cabling.
Figure 3. SC100/SC120 Back Panel View
8
About the SC100/SC120 Expansion Enclosure
Item Name Icon Description
1 DC power indicator
Green: Normal operation. The power supply
module is supplying DC power to the expansion enclosure
Off: Power switch is off, the power supply is not
connected to AC power, or there is a fault condition
2 Power supply/cooling fan
indicator
Amber: Power supply/cooling fan fault is detected
Off: Normal operation
3 AC power indicator
Green: Power supply module is connected to a
source of AC power, whether or not the power switch is on
Off: Power supply module is disconnected from a
source of AC power
4 Power socket (2) Accepts a standard computer power cord.
5 Power switches (2) Controls power for the expansion enclosure. There is
one switch for each power supply/cooling fan module.
6 Power supply/cooling fan
modules (2)
Contains a 700 W power supply and fans that provide
cooling for the expansion enclosure.
7 Enclosure Management
Modules (2)
EMMs provide the data path and management
functions for the expansion enclosure.
SC100/SC120 Expansion Enclosure EMM Features and Indicators
The SC100/SC120 includes two Enclosure Management Modules (EMMs) in two interface slots.
Figure 4. SC100/SC120 EMM Features and Indicators
Item Name Icon Description
1 System status
indicator
Not used on SC100/SC120 expansion enclosures.
2 Serial port Not for customer use.
3 SAS port A (in) Connects to a storage controller or to other SC100/SC120
expansion enclosures. SAS ports A and B can be used for either input or output. However for cabling consistency, use port A as an input port.
4 Port A link
status
Green: All the links to the port are connected
Amber: One or more links are not connected
Off: Expansion enclosure is not connected
About the SC100/SC120 Expansion Enclosure
9
Item Name Icon Description
5 SAS port B
(out)
Connects to a storage controller or to other SC100/SC120 expansion enclosures. SAS ports A and B can be used for either input or output. However for cabling consistency, use port B as an output port.
6 Port B link
status
Green: All the links to the port are connected
Amber: One or more links are not connected
Off: Expansion enclosure is not connected
7 EMM status
indicator
On steady green: Normal operation
Amber: Expansion enclosure did not boot or is not properly
configured
Blinking green: Automatic update in process
Blinking amber (two times per sequence): Expansion
enclosure is unable to communicate with other expansion enclosures
Blinking amber (four times per sequence): Firmware update
failed
Blinking amber (five times per sequence): Firmware versions
are different between the two EMMs
SC100/SC120 Expansion Enclosure Drives
Dell Enterprise hard disk drives (HDDs) and Enterprise Solid-State Drives (eSSDs) are the only drives that can be installed in
SC100/SC120 expansion enclosures. If a non-Dell Enterprise drive is installed, Storage
Center prevents the drive from being managed. The drives in an SC100 expansion enclosure are installed horizontally. The drives in an SC120 expansion
enclosure are installed vertically. The indicators on the drives provide status and activity information.
Figure 5. SC100/SC120 Drive Indicators
Item Name Indicator Code
1 Drive activity
indicator
Blinking green: Indicates drive activity
Steady green: Indicates no drive activity
2 Drive status
indicator
Steady green: Normal operation
Blinking green (on 1 sec. / off 1 sec.): Drive identification is enabled
Off: No power to the drive
10
About the SC100/SC120 Expansion Enclosure
Loading...
+ 22 hidden pages