Dell POWEREDGE R620 User Manual

Author(s)
Wei Liu
Raja Tamilarasan
Servers
Updating BIOS on Dell 12G PowerEdge Servers
This document is for informational purposes only and may contain typographical errors and technical inaccuracies. The content is provided as is, without express or implied warranties of any kind.
© 2012 Dell Inc. All rights reserved. Dell and its affiliates cannot be responsible for errors or omissions in typography or photography. Dell, the Dell logo, and PowerEdge are trademarks of Dell Inc. Intel and Xeon are registered trademarks of Intel Corporation in the U.S. and other countries. Microsoft, Windows, and Windows Server are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell disclaims proprietary interest in the marks and names of others.
April 2012| Rev 1.0
ii
Updating BIOS on Dell 12G PowerEdge Servers
Contents
Introduction ............................................................................................................. 5
1:1 Updates ................................................................................................................. 5
BIOS DUP (Dell Update Package) from the Operating System (OS) ............................................ 5
Windows DUP ......................................................................................................... 5
Linux DUP ............................................................................................................. 9
DOS-based BIOS Flash Utility ....................................................................................... 10
UEFI-based BIOS Flash Utility ....................................................................................... 11
Run BIOS Flash Utility in UEFI Shell ............................................................................. 11
Load the BIOS Flash Utility from BIOS Boot Manager ........................................................ 15
Update BIOS via Lifecycle Controller (F10) ...................................................................... 17
1:Many Updates .......................................................................................................... 20
Remote BIOS Update using WSMAN ................................................................................ 20
Before you Begin ................................................................................................... 21
Performing a firmware update on your system ............................................................... 22
Bios update using Repository Manager ............................................................................ 28
Bios update using Dell Management Plug-In for VMware vCenter ............................................ 28
Bios update using Dell Chassis Management Controller (CMC)................................................ 28
Figures
Figure 1. Windows DUP ............................................................................................... 6
Figure 2. After DUP installation, a system reboot is required for the update to be staged .............. 7
Figure 3. System reboots to Lifecycle Controller ................................................................ 8
Figure 4. The BIOS update inside Lifecycle Controller .......................................................... 9
Figure 5. Linux DUP .................................................................................................. 10
Figure 6. DOS-based BIOS flash utility ............................................................................ 11
Figure 7. BIOS Boot Manager ....................................................................................... 12
Figure 8. Flash BIOS in UEFI shell ................................................................................. 13
Figure 9. UEFI-based BIOS flash utility ........................................................................... 14
Figure 10. UEFI-based BIOS flash utility ........................................................................... 15
Figure 11. BIOS Update File Explorer .............................................................................. 16
Figure 12. Use BIOS Update File Explorer to select the BIOS UEFI flash utility file to update .......... 17
Figure 13. Lifecycle Controller screen after pressing F10 during POST ...................................... 18
Figure 14. Platform Update screen ................................................................................. 18
Figure 15. Select Update Repository in Platform Update ...................................................... 19
Figure 16. Select the local drive and type in the DUP file to use............................................. 20
iii
Updating BIOS on Dell 12G PowerEdge Servers
Figure 17. Remote Firmware Update .............................................................................. 21
iv
Updating BIOS on Dell 12G PowerEdge Servers
Introduction
Customers using the 12th generation Dell PowerEdge Servers have a variety of ways to update the system BIOS. Customers can use any of the following methods, based on their needs and environment.
Executing the BIOS DUP (Dell Update Package) from the operating system (OS) Using the DOS-based BIOS flash utility Using the UEFI-based BIOS flash utility Using the Lifecycle Controller Platform Update option (F10) Using the WSMAN-based 1:Many Remote Update method (Remote Enablement)
1:1 Updates
BIOS DUP (Dell Update Package) from the Operating System (OS)
Windows DUP
Installation steps:
1. Browse to the location where you downloaded the file (for example,
BIOS_VT7R8_WN32_1.1.0.EXE) and double-click the new file.
2. Read the release information presented in the dialog window (Figure 1).
5
Updating BIOS on Dell 12G PowerEdge Servers
Figure 1.
Windows DUP
3. Click Install.
4. Follow the remaining prompts to perform the update (Figure 2).
6
Updating BIOS on Dell 12G PowerEdge Servers
Figure 2.
After DUP installation, a system reboot is required for the update to be staged
5. The system will reboot and launch Lifecycle Controller (Figure 3).
7
Updating BIOS on Dell 12G PowerEdge Servers
Figure 3.
System reboots to Lifecycle Controller
6. The Lifecycle Controller will invoke the BIOS update (Figure 4). This may take a few minutes.
After the BIOS is updated, a system reboot will automatically take place and boot back to the host operating system.
8
Updating BIOS on Dell 12G PowerEdge Servers
Figure 4.
The BIOS update inside Lifecycle Controller
Linux DUP
Installation steps:
1. Read over the release information presented by executing the "./PER710_BIOS_LX_6.0.7.BIN"
command from the shell.
2. Run the update by executing "./PER710_BIOS_LX_6.0.7.BIN" from the shell (Figure 5).