Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.
is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, and PowerEdge are trademarks of Dell Inc.;
Intel and Xeon are registered trademarks of Intel Corporation in the U.S. and other countries;
Microsoft, Hyper-V, Windows, and Windows Server are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries; Red Hat and Red Hat Enterprise
Linux are registered trademarks of Red Hat, Inc. in the United States and other countries; SUSE is a
registered trademark of Novell, Inc., in the United States and other countries; VMware and vSphere
are registered trademarks or trademarks (the "Marks") of VMware, Inc. in the United States and/or
other jurisdictions; Citrix and XenServer are trademarks of Citrix Systems, Inc. and/or more of its
subsidiaries, and may be registered in the United States Patent and Trademark Office and in
other countries.
Other trademarks and trade names may be used in this document to refer to either the entities claiming
the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks
and trade names other than its own.
Regulatory Model E12S Series and E13S Series
October 2009P/N WPDP0Rev. A00
Installation and Configuration
WARNING: Before performing the following procedure, review the safety
instructions that came with the system.
Unpacking the System
Unpack your system and identify each item.
Assemble the rails and install the system in the rack following the safety
instructions and the rack installation instructions provided with your system.
Getting Started With Your System3
Optional – Connecting the Keyboard, Mouse, and Monitor
Connect the keyboard, mouse, and monitor (optional).
The connectors on the back of your system have icons indicating which cable
to plug into each connector. Be sure to tighten the screws (if any) on the
monitor's cable connector.
Connecting the Power Cable(s)
Connect the system’s power cable(s) to the system and, if a monitor is used,
connect the monitor’s power cable to the monitor.
4Getting Started With Your System
Securing the Power Cable(s)
Bend the system power cable into a loop as shown in the illustration and secure
the cable to the bracket using the provided strap. Plug the other end of the
power cable into a grounded electrical outlet or a separate power source such
as an uninterrupted power supply (UPS) or a power distribution unit (PDU).
Turning On the System
Press the power button on the system and the monitor. The power indicators
should light.
Getting Started With Your System5
Installing the Optional Bezel
Install the bezel (optional).
Complete the Operating System Setup
If you purchased a preinstalled operating system, see the operating system
documentation that ships with your system. To install an operating system
for the first time, see the installation and configuration documentation
for your operating system. Be sure the operating system is installed before
installing hardware or software not purchased with the system.
Supported Operating Systems
NOTE: For twelve–hard-drive systems with additional internal hard drives,
it is recommended that you install the operating system on the internal hard drives
in a RAID 1 configuration.
•Microsoft® Windows Server® 2008 Hyper-V™ Standard (x64) Edition
•Microsoft Windows
and Premium (x64) Editions
•Microsoft Windows Essential Business Server 2008
Premium (x86) Edition
•Microsoft Windows Essential Business Server 2008 Standard
and Premium (x64) Editions
6Getting Started With Your System
®
Small Business Server 2008 Standard
•Microsoft Windows Server 2008 Standard, Enterprise, and
Datacenter (x64) Editions with SP2 with Hyper-V role enabled
•Microsoft Windows Web Server 2008 with SP2 with Hyper-V role enabled
•Microsoft Windows Server 2008 Standard and Enterprise (x86) Editions
with SP2
•Microsoft Windows Web Server 2008 with SP2
•Microsoft Windows Server 2008 R2 Standard, Enterprise,
and Datacenter (x64) Editions with Hyper-V role enabled
•Microsoft Windows Web Server 2008 R2 with Hyper-V role enabled
•Microsoft Windows HPC Server 2008 R2 (x64) Edition
•Microsoft Windows Server 2003 R2 Standard and Enterprise (x86)
Editions with SP2
•Microsoft Windows HPC Server 2008 (x64) Edition
NOTE: Not supported on twelve–hard-drive systems.
•Microsoft Windows Server 2003 R2 Standard, Enterprise,
and Datacenter (x64) Editions with SP2
•Red Hat
•Red Hat
®
Enterprise Linux® AS and ES (Version 4.8) (x86_64)
Enterprise Linux AS and ES (Version 4.8) (x86)
•Red Hat Enterprise Linux Server 5.3 (x86_64)
•Red Hat Enterprise Linux Server 5.3 (x86)
®
•SUSE
Linux Enterprise Server 10 (x86_64) with SP3
•SUSE Linux Enterprise Server 11 (x86_64)
®
•VMware
vSphere™ ESXi Version 4.0
Getting Started With Your System7
•VMware Virtual Infrastructure 3 ESXi Version 3.5 Update 4
NOTE: VMware Virtual Infrastructure 3 ESXi Version 3.5 Update 4
is not supported on twelve–hard-drive systems.
•Citrix® XenServer™ Enterprise (Version 5.5)
NOTE: Twelve–hard-drive systems support Citrix XenServer Enterprise
(Version 6.0).
•Citrix Essentials for XenServer Enterprise (Version 5.5)
NOTE: For the latest information on supported operating systems,
see support.dell.com.
Other Information You May Need
WARNING: See the safety and regulatory information that shipped with
your system. Warranty information may be included within this document
or as a separate document.
•The rack documentation included with your rack solution describes
how to install your system into a rack.
•The
•Any media that ships with your system that provides documentation
Hardware Owner’s Manual
features and describes how to troubleshoot the system and install or
replace system components. This document is available online at
support.dell.com/manuals
and tools for configuring and managing your system, including those
pertaining to the operating system, system management software,
system updates, and system components that you purchased
with your system.
provides information about system
.
NOTE: Always check for updates on support.dell.com/manuals and read the
updates first because they often supersede information in other documents.
Obtaining Technical Assistance
If you do not understand a procedure in this guide or if the system does
not perform as expected, see your Hardware Owner’s Manual. Dell™ offers
comprehensive hardware training and certification. See www.dell.com/training
for more information. This service may not be offered in all locations.
8Getting Started With Your System
Technical Specifications
Processor
®
Processor typeTwo Intel
Expansion Bus
Bus typePCI Express Generation 2
Expansion slots using riser cards
NOTE: Depending on the configuration, your system may have either riser 1 or riser 2.
Graphics Processing Units (GPGPU) optimized
configuration is available on riser 2.
Memory
Architecture1066 or 1333 MHz DDR3 registered or
unbuffered Error Correcting Code (ECC)
DIMMs
Memory module socketsEight 240-pin
Memory module capacities
Four–hard-drive systems
Eight–hard-drive systems
Twelve–hard-drive systems
Minimum RAM1 GB with a single processor
Maximum RAM
Four–hard-drive systems
Eight–hard-drive systems
Twelve–hard-drive systems
1 GB, 2 GB, or 4 GB
1 GB, 2 GB, 4 GB, or 8 GB
1 GB, 2 GB, 4 GB, or 8 GB
(1 DIMM per processor)
32 GB
64 GB (8 GB dual- and quad-rank DIMMs)
64 GB (8 GB dual- and quad-rank DIMMs)
Xeon® processors 5500 series
Getting Started With Your System9
Drives
Hard drives
Four–hard-drive systems
Up to four 3.5-inch, cabled SAS, SATA,
or SSD drives
Eight–hard-drive systems
Twelve–hard-drive systems
Up to eight 3.5-inch or 2.5-inch,
hot-swappable SAS, SATA, or SSD drives
Up to twelve 3.5-inch or 2.5-inch,
hot-swappable SAS, SATA, or SSD drives and
up to two cabled 2.5-inch SAS or SSD drives
NOTE: For twelve–hard-drive systems
with additional internal hard drives, it is
recommended that you install the operating
system on the internal hard drives in a RAID 1
configuration.
Optical drive Optional internal slim-line SATA DVD-ROM
or DVD+/-RW
Optional external USB DVD-ROM
NOTE: Twelve–hard-drive systems support
only an external USB DVD-ROM.
Diskette driveOptional external USB 1.44-MB
Connectors
Back
NIC
Serial
USB
Video
Front
Video
USB
Internal
USB
Two RJ-45 (for integrated 1-GB NICs)
9-pin, DTE, 16550-compatible
Two 4-pin, USB 2.0-compliant
15-pin VGA
15-pin VGA
Two 4-pin, USB 2.0-compliant
Two 4-pin, USB 2.0-compliant
10Getting Started With Your System
Video
Video typeMatrox G200, integrated in the BMC
Video memory 8 MB
Power
AC power supply (per power supply)
Wattage
Four–hard-drive systems
Eight–hard-drive systems
Twelve–hard-drive systems
Vo lt ag e
Heat dissipation
Four–hard-drive systems
Eight–hard-drive systems
Twelve–hard-drive systems
Maximum inrush current
Batteries
System battery
480 W (non-redundant power supply)
750 W/1100 W (optional redundant
power supply)
750 W (optional redundant power supply)
100–240 VAC, autoranging, 50–60 Hz
1840 BTU/hr maximum
2200 BTU/hr maximum
2450 BTU/hr maximum
Under typical line conditions and over
the entire system ambient operating range,
the inrush current may reach 55 A per
power supply for 10 ms or less.
CR 2032 3.0-V lithium ion coin cell
Physical
Height
Four– and eight– hard-drive
systems
Twelve–hard-drive systems
Width
Four– and eight–hard-drive
systems
Twelve–hard-drive systems
8.64 cm (3.4 in)
8.67 cm (3.42 in)
43.66 cm (17.19 in)
44.52 cm (17.53 in)
Getting Started With Your System11
Physical (continued)
Depth
Four– and eight–hard-drive
systems
Twelve–hard-drive systems
Weight (maximum configuration)
Four–hard-drive systems
Eight–hard-drive systems
Twelve–hard-drive systems
Weight (empty)
Four–hard-drive systems
Eight–hard-drive systems
Twelve–hard-drive systems
Environmental
61.02 cm (24.09 in)
66.46 cm (26.17 in)
16 kg (35.2 lbs)
22.5 kg (49.5 lbs)
29.0 kg (63.8 lbs)
13.6 kg (29.92 lbs)
13.5 kg (29.7 lbs)
15.85 kg (34.87 lbs)
NOTE: For additional information about environmental measurements for specific
system configurations, see www.dell.com/environmental_datasheets.
Temperature
Operating
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE: For altitudes above 2950 feet,
the maximum operating temperature
is derated 1ºF/550 ft.
Storage
Relative humidity
Operating
Storage
–40° to 65°C (–40° to 149°F) with
a maximum temperature gradation
of 20°C per hour
20% to 80% (noncondensing) with
a maximum humidity gradation
of 10% per hour
5% to 95% (noncondensing)
12Getting Started With Your System
Environmental (continued)
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
Airborne Contaminant Level
Class
0.26 G at 5–350 Hz for 15 min
1.54 G at 10–250 Hz for 15 min
One shock pulse in the positive z axis
(one pulse on each side of the system) of
31 G for 2.6 ms in the operational orientation
Six consecutively executed shock pulses
in the positive and negative x, y, and z axes
(one pulse on each side of the system)
of 71 G for up to 2 ms
–16 to 3.048 m (–50 to 10,000 ft)
NOTE: For altitudes above 2950 feet,
the maximum operating temperature
is derated 1ºF/550 ft.
–16 to 10,600 m (–50 to 35,000 ft)
G2 or lower as defined by ISA-S71.04-1985
Getting Started With Your System13
14Getting Started With Your System
Dell™ PowerEdge™
Systémy R510
Začínáme se
systémem
Regulatorní model řady E12S a řady E13S
Poznámky a upozornění
POZNÁMKA: POZNÁMKA označuje důležité informace, které pomáhají
lepšímu využití počítače.
UPOZORNĚNÍ: UPOZORNĚNÍ poukazuje na možnost poškození
hardwaru nebo ztráty dat v případě nedodržení pokynů.
VAROVÁNÍ: VAROVÁNÍ upozorňuje na potenciální nebezpečí
Jakákoli reprodukce těchto materiálů bez písemného povolení společnosti Dell Inc. je přísně zakázána.
Ochranné známky použité v tomto textu: Dell, logo DELL a PowerEdge jsou ochranné známky
společnosti Dell Inc. Intel a Xeon jsou registrované ochranné známky společnosti Intel Corporation
v USA a dalších zemích. Microsoft, Hyper-V, Windows a Windows Server jsou ochranné známky nebo
registrované ochranné známky společnosti Microsoft Corporation v USA a dalších zemích. Red Hat
a Red HatEnterprise Linux jsou registrované ochranné známky společnosti Red Hat, Inc. v USA a
dalších zemích. SUSE je registrovaná ochranná známka společnosti Novell, Inc. v USA a dalších
zemích. VMware a vSphere jsou registrované ochranné známky nebo ochranné známky společnosti
VMware, Inc. v USA a dalších zemích. Citrix a XenServer jsou ochranné známky společnosti Citrix
Systems, Inc. a/nebo jedné nebo více jejích poboček a mohou být registrovány úřadem pro patenty
a ochranné známky v USA a dalších zemích.
V tomto dokumentu mohou být použity další ochranné známky a obchodní názvy s odkazem
na společnosti vlastnící tyto známky a názvy nebo na jejich produkty. Společnost Dell Inc. nemá
vlastnické zájmy vůči ochranným známkám a obchodním názvům jiným než svým vlastním.
Regulatorní model řady E12S a řady E13S
Říjen 2009Č. dílu WPDP0Rev. A00
Instalace a konfigurace
VAROVÁNÍ: Před provedením následujícího postupu si prostudujte
bezpečnostní pokyny dodané se systémem.
Rozbalení systému
Rozbalte systém a identifikujte jeho jednotlivé součásti.
Sestavte kolejničky a nainstalujte systém do stojanu podle bezpečnostních pokynů
a pokynů k instalaci do stojanu dodaných se systémem.
Začínáme se systémem17
Volitelné – Připojení klávesnice, myši a monitoru
Připojte klávesnici, myš a monitor (volitelné).
Konektory na zadní straně systému mají ikony znázorňující, který kabel se má
připojit ke kterému konektoru. Zajistěte, aby šrouby na konektoru kabelu monitoru
byly dobře dotaženy (je-li jimi konektor vybaven).
Připojení napájecích kabelů
Připojte napájecí kabely k systému, a pokud používáte monitor, připojte napájecí
kabel také k monitoru.
18Začínáme se systémem
Zajištění napájecích kabelů
Ohněte napájecí kabel systému do smyčky, jak je znázorněno na obrázku, a
připevněte jej dodanou páskou k držáku. Poté zasuňte druhý konec napájecího
kabelu do uzemněné elektrické zásuvky nebo jej připojte k samostatnému zdroji
napájení, například ke zdroji nepřerušitelného napájení (UPS) nebo jednotce
rozvaděče (PDU).
Zapnutí systému
Stiskněte vypínač na systému a na monitoru. Indikátory napájení by se měly
rozsvítit.
Začínáme se systémem19
Instalace volitelného čelního krytu
Nainstalujte čelní kryt (volitelný).
Dokončení nastavení operačního systému
Pokud jste zakoupili předinstalovaný operační systém, prostudujte dokumentaci
k operačnímu systému dodanou se systémem. Chcete-li provést první instalaci
operačního systému, postupujte podle dokumentace k instalaci a konfiguraci
operačního systému. Než začnete s instalací hardwaru či softwaru, který nebyl
zakoupen společně se systémem, ujistěte se, že je nainstalován operační systém.
Podporované operační systémy
POZNÁMKA: U systémů s dvanácti pevnými disky, které obsahují další
vnitřní pevné disky, se doporučuje instalovat operační systém na interní
pevné disky v konfiguraci RAID 1.
•
Microsoft® Windows Server® 2008 Hyper-V™, edice Standard (x64)
•
Microsoft Windows® Small Business Server 2008, edice Standard a
Premium (x64)
•
Microsoft Windows Essential Business Server 2008, edice Premium (x86)
•
Microsoft Windows Essential Business Server 2008, edice Standard
a Premium (x64)
20Začínáme se systémem
•
Microsoft Windows Server 2008, edice Standard, Enterprise
a Datacenter (x64) s aktualizací SP2 a povolenou rolí Hyper-V
•
Microsoft Windows Web Server 2008 s aktualizací SP2 a povolenou
rolí Hyper-V
•
Microsoft Windows Server 2008, edice Standard a Enterprise (x86)
s aktualizací SP2
•
Microsoft Windows Web Server 2008 s aktualizací SP2
•
Microsoft Windows Server 2008 R2, edice Standard, Enterprise
a Datacenter (x64) s povolenou rolí Hyper-V
•
Microsoft Windows Web Server 2008 R2 s povolenou rolí Hyper-V
•
Microsoft Windows HPC Server 2008 R2 (x64)
•
Microsoft Windows Server 2003 R2, edice Standard a Enterprise (x86)
s aktualizací SP2
•
Microsoft Windows HPC Server 2008 (x64)
POZNÁMKA: Není podporován na systémech s 12 pevnými disky.
•
Microsoft Windows Server 2003 R2, edice Standard, Enterprise
a Datacenter (x64) s aktualizací SP2
•
Red Hat® Enterprise Linux® AS a ES, verze 4.8 (x86_64)
•
Red Hat Enterprise Linux AS a ES, verze 4.8 (x86)
•
Red Hat Enterprise Linux Server 5.3 (x86_64)
•
Red Hat Enterprise Linux Server 5.3 (x86)
•
SUSE® Linux Enterprise Server 10 (x86_64) s aktualizací SP3
•
SUSE Linux Enterprise Server 11 (x86_64)
•
VMware® vSphere™ ESXi verze 4.0
•
VMware Virtual Infrastructure 3 ESXi verze 3.5, aktualizace 4
POZNÁMKA: VMware Virtual Infrastructure 3 ESXi verze 3.5,
aktualizace 4 není podporován na systémech s 12 pevnými disky.
Začínáme se systémem21
•
Citrix® XenServer™ Enterprise (verze 5.5)
POZNÁMKA: Systémy s 12 pevnými disky podporují Citrix XenServer
Enterprise (verze 6.0).
•
Citrix Essentials for XenServer Enterprise (verze 5.5)
POZNÁMKA: Nejnovější informace o podporovaných operačních
systémech naleznete na webu support.dell.com.
Další užitečné informace
VAROVÁNÍ: Prostudujte si informace o bezpečnosti a předpisech,
které byly dodány se systémem. Informace o záruce jsou součástí
tohoto dokumentu nebo jsou přiloženy samostatně.
•
Pokyny k instalaci do stojanu dodané se stojanovým řešením popisují
instalaci systému do stojanu.
•
Příručka majitele hardwaru
popisuje řešení problémů se systémem a instalaci nebo výměnu komponent.
Tento dokument je k dispozici online na adrese
•
Média dodaná se systémem obsahují dokumentaci a nástroje pro konfiguraci
a správu systému. Mohou být dodána například média týkající se operačního
systému, softwaru pro správu systému, aktualizací systému a komponent
zakoupených se systémem.
POZNÁMKA: Vždy nejprve zkontrolujte a pročtěte aktualizace
uvedené na adrese support.dell.com/manuals, protože tyto
aktualizace často nahrazují informace v ostatních dokumentech.
obsahuje informace o funkcích systému a
support.dell.com/manuals
.
Odborná pomoc
Nerozumíte-li některému z postupů popsaných v této příručce nebo nepracuje-li
systém podle očekávání, nahlédněte do
Dell™ nabízí v souvislosti s hardwarem kompletní školení a certifikaci.
Další informace naleznete na webových stránkách
Tato služba nemusí být nabízena ve všech regionech.
22Začínáme se systémem
Příručky majitele hardwaru
www.dell.com/training
. Společnost
.
Technické údaje
Procesor
Typ procesoruDva procesory řady Intel® Xeon® 5500
Rozšiřovací sběrnice
Typ sběrnicePCI Express 2. generace
Rozšiřovací sloty na zvedacích kartách
POZNÁMKA: V závislosti na konfiguraci bude systém vybaven zvedací kartou
1 nebo zvedací kartou 2.
Zvedací karta 1
NEBO
Zvedací karta 2
Pamět’
ArchitekturaPamět’ové moduly DIMM s taktovací frekvencí
Sloty pro pamět’ové modulyOsm 240kolíkových
Kapacity pamět’ových modulů
Systémy se čtyřmi pevnými disky
Systémy s osmi pevnými disky
Systémy s dvanácti pevnými disky
Minimum paměti RAM1 GB s jedním procesorem
Slot 1: PCIe x4, poloviční délka, plná výška
Slot 2: PCIe x4, plná délka, plná výška
Slot 3: PCIe x8, poloviční délka, plná výška
Slot 4: PCIe x4, interní slot pro integrovanou kartu
POZNÁMKA: Všechny čtyři sloty mají
konektory x8.
Slot 1: PCIe x16, plná délka, plná výška
Slot 2: PCIe x4, interní pro integrovanou kartu
POZNÁMKA: Na zvedací kartě 2 je k
dispozici konfigurace optimalizovaná pro
provádění obecných výpočtů grafickým
procesorem (GPGPU).
1066 nebo 1333 MHz, typ DDR3, registrované
nebo bez vyrovnávací paměti, s ochranou ECC
1 GB, 2 GB nebo 4 GB
1 GB, 2 GB, 4 GB nebo 8 GB
1 GB, 2 GB, 4 GB nebo 8 GB
(1 modul DIMM na každý procesor)
Začínáme se systémem23
Pamět’ (pokračování)
Maximum paměti RAM
Systémy se čtyřmi pevnými disky
Systémy s osmi pevnými disky
Systémy s dvanácti pevnými
disky
Jednotky
Pevné disky
Systémy se čtyřmi pevnými disky
32 GB
64 GB (duální a kvadrální moduly DIMM
po 8 GB)
64 GB (duální a kvadrální moduly DIMM
po 8 GB)
Až čtyři 3,5palcové disky SAS, SATA nebo SSD
připojené kabelem
Systémy s osmi pevnými disky
Až osm 3,5palcových nebo 2,5palcových
disků SAS, SATA nebo SSD vyměnitelných
za provozu
Systémy s dvanácti pevnými disky
Až dvanáct 3,5palcových nebo 2,5palcových
disků SAS, SATA nebo SSD vyměnitelných za
provozu a až dva 2,5 palcové disky SAS nebo
SSD připojené kabelem
POZNÁMKA: U systémů s dvanácti
pevnými disky, které obsahují další vnitřní
pevné disky, se doporučuje instalovat
operační systém na interní pevné disky
v konfiguraci RAID 1.
Optická jednotka Volitelná interní jednotka SATA DVD-ROM
nebo DVD+/-RW (slim-line)
Volitelná externí jednotka USB DVD-ROM
POZNÁMKA: Systémy s dvanácti pevnými
disky podporují pouze externí jednotku USB
DVD-ROM.
Disketová jednotkaVolitelná externí jednotka USB 1,44 MB
24Začínáme se systémem
Konektory
Zadní panel
NICDva konektory RJ-45 (pro integrované sít’ové
karty 1 Gb/s)
Sériový port9kolíkový, DTE, kompatibilní s obvodem 16550
USBDva 4kolíkové, USB 2.0
Video15kolíkový VGA
Přední panel
Video15kolíkový VGA
USBDva 4kolíkové, USB 2.0
Interní
USBDva 4kolíkové, USB 2.0
Video
Typ grafikyKarta Matrox G200, integrovaná v řadiči BMC
Grafická pamět’ 8 MB
Napájení
Střídavý proud (na jeden napájecí zdroj)
Výkon
Systémy se čtyřmi pevnými disky
Systémy s osmi pevnými disky
Systémy s dvanácti pevnými disky
Napětí100–240 V stř., automatické stanovení rozsahu,
Odvod tepla
Systémy se čtyřmi pevnými disky
Systémy s osmi pevnými disky
Systémy s dvanácti pevnými disky
Maximální nárazový proudZa typických podmínek napájení a v celém