Dell OpenManage Server Administrator Version 7.2 SNMP Reference Guide

Dell OpenManage SNMP Reference Guide Version 7.2
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use of your computer.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
© 2012 Dell Inc.
Trademarks used in this text: Dell™, the Dell logo, Dell Boomi™, Dell Precision™ , OptiPlex™, Latitude™, PowerEdge™, PowerVault™, PowerConnect™, OpenManage™, EqualLogic™, Compellent™, KACE™, FlexAddress™, Force10™ and Vostro™ are trademarks of Dell Inc. Intel®, Pentium®, Xeon®, Core® and Celeron® are registered trademarks of Intel Corporation in the U.S. and other countries. AMD is a registered trademark and AMD Opteron™, AMD Phenom™ and AMD Sempron™ are trademarks of Advanced Micro Devices, Inc. Microsoft®, Windows®, Windows Server®, Internet Explorer®, MS-DOS®, Windows Vista® and Active Directory® are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Red Hat® and Red Hat Enterprise Linux® are registered trademarks of Red Hat, Inc. in the United States and/or other countries. Novell® and SUSE® are registered trademarks of Novell Inc. in the United States and other countries. Oracle® is a registered trademark of Oracle Corporation and/or its affiliates. Citrix®, Xen®, XenServer® and XenMotion® are either registered trademarks or trademarks of Citrix Systems, Inc. in the United States and/or other countries. VMware trademarks of VMware, Inc. in the United States or other countries. Corporation.
2012 - 12
®
,
Virtual SMP
®
®
,
vMotion
®
is a registered trademark of International Business Machines
IBM
,
vCenter
®
and
vSphere
®
are registered trademarks or
®
®
Rev. A00
Contents
Notes, Cautions, and Warnings...................................................................................................2
1 Introduction................................................................................................................................11
Supported SNMP Versions.....................................................................................................................................11
Introduction to the SNMP Reference Guide...........................................................................................................11
Server Administrator Instrumentation MIB......................................................................................................11
Server Administrator Remote Access MIB......................................................................................................13
Server Administrator Baseboard Management Controller, ASF MIB..............................................................13
Server Administrator Field Replaceable Unit MIB...........................................................................................13
Server Administrator Storage Management MIB............................................................................................14
Server Administrator Change Management MIB............................................................................................14
Dell Remote Access Controller Out-of-Band MIB...........................................................................................15
How This Guide Defines Technical Terms.......................................................................................................15
Basic Terminology............................................................................................................................................15
Frequently Used Terms in Variable Names......................................................................................................15
Tables...............................................................................................................................................................16
Section Organization........................................................................................................................................17
Other Documents You May Need.....................................................................................................................18
Introduction to the Server Administrator SNMP Subagent....................................................................................18
Management Information Base Object Identifiers..........................................................................................19
SNMP Security.................................................................................................................................................20
Management Actions.......................................................................................................................................20
SNMP Traps.....................................................................................................................................................21
2 Dell OpenManage SNMP Version 7.2....................................................................................23
What’s New in This Release...................................................................................................................................23
3 Instrumentation MIB Version Group......................................................................................27
Management Information Base Major Version Number........................................................................................27
Management Information Base Minor Version Number........................................................................................27
Management Information Base Maintenance Version Number............................................................................27
4 Systems Management Software Group................................................................................29
Systems Management Software............................................................................................................................29
Systems Management Software Variable Values..................................................................................................32
5 System State Group..................................................................................................................33
System State Group Table......................................................................................................................................33
System State Table..........................................................................................................................................33
List 1.................................................................................................................................................................33
List 2.................................................................................................................................................................34
System State Table..........................................................................................................................................34
6 Chassis Information Group......................................................................................................49
Chassis Information Group Tables..........................................................................................................................49
Chassis Information Table................................................................................................................................49
UUID Table.......................................................................................................................................................60
POST Log Table................................................................................................................................................61
Event Log Table................................................................................................................................................63
System BIOS Table...........................................................................................................................................65
Firmware Table.................................................................................................................................................70
Intrusion Table.................................................................................................................................................73
Baseboard Table..............................................................................................................................................75
Chassis Information Group Variable Values...........................................................................................................78
7 Operating System Group..........................................................................................................89
Operating System Memory Table...........................................................................................................................89
8 System Resource Group..........................................................................................................93
System Resource Group Tables.............................................................................................................................93
System Resource Map Table...........................................................................................................................93
System Resource Owner Table........................................................................................................................95
System Resource Input/Output (I/O) Port Table...............................................................................................97
System Resource Memory Table.....................................................................................................................99
System Resource Interrupt Table..................................................................................................................101
System Resource Direct Memory Access (DMA) Table................................................................................104
System Resource Group Variable Values.............................................................................................................106
9 Power Group............................................................................................................................109
Power Group Tables.............................................................................................................................................109
Power Unit Table............................................................................................................................................109
Power Supply Table.......................................................................................................................................111
Voltage Probe Table.......................................................................................................................................114
Amerage Probe Table....................................................................................................................................118
AC Power Switch Table.................................................................................................................................122
AC Power Cord Table.....................................................................................................................................124
Battery Table..................................................................................................................................................126
Power Usage Table........................................................................................................................................127
Power Profile Table........................................................................................................................................132
Power Group Variable Values...............................................................................................................................134
10 Thermal Group.......................................................................................................................143
Thermal Group Tables..........................................................................................................................................143
Cooling Unit Table..........................................................................................................................................143
Cooling Device Table......................................................................................................................................145
Temperature Probe Table..............................................................................................................................149
Thermal Group Variable Values............................................................................................................................153
11 User Security Group.............................................................................................................155
User Security Group Table...................................................................................................................................155
12 Remote Flash BIOS Group...................................................................................................157
Remote Flash BIOS Group Table..........................................................................................................................157
Remote Flash BIOS Table...............................................................................................................................157
Remote Flash BIOS Variable Values.....................................................................................................................159
13 Port Group..............................................................................................................................161
Port Group Tables.................................................................................................................................................161
Pointing Port Table.........................................................................................................................................161
Keyboard Port Table.......................................................................................................................................163
Processor Port Table......................................................................................................................................166
Memory Device Port Table.............................................................................................................................168
Monitor Port Table.........................................................................................................................................171
Small Computer System Interface (SCSI) Port Table.....................................................................................173
Parallel Port Table..........................................................................................................................................175
Serial Port Table.............................................................................................................................................179
Universal Serial Bus (USB) Port Table...........................................................................................................182
Port Group Variable Values..................................................................................................................................184
14 Device Group.........................................................................................................................189
Device Tables.......................................................................................................................................................189
Pointing Device Table....................................................................................................................................189
Keyboard Device Table..................................................................................................................................191
Processor Device Table.................................................................................................................................193
Processor Device Status Table......................................................................................................................199
Cache Device Table.......................................................................................................................................201
Memory Device Table....................................................................................................................................205
Memory Device Mapped Address Table.......................................................................................................211
Generic Device Table.....................................................................................................................................214
PCI Device Table............................................................................................................................................216
PCI Device Configuration Space Table..........................................................................................................218
Network Device Table....................................................................................................................................221
Managed System Services Device Table......................................................................................................227
SD Card Unit Table.........................................................................................................................................228
SD Card Device Table....................................................................................................................................230
Device Group Variable Values..............................................................................................................................233
15 Slot Group...............................................................................................................................257
System Slot Group Table......................................................................................................................................257
System Slot Variable Values.................................................................................................................................260
16 Memory Group.......................................................................................................................267
Physical Memory Tables......................................................................................................................................267
Physical Memory Array Table........................................................................................................................267
Physical Memory Array Mapped Table.........................................................................................................271
Physical Memory Configuration Table...........................................................................................................273
Physical Memory Logging Table....................................................................................................................276
Redundant Memory Unit Table......................................................................................................................277
Physical Memory Card Table.........................................................................................................................279
Memory Group Variable Values............................................................................................................................282
17 BIOS Setup Control Group...................................................................................................287
BIOS Setup Control Group Tables........................................................................................................................287
BIOS Setup Control Group Tables..................................................................................................................287
SCSI Control Table.........................................................................................................................................296
Parallel Port Control Table.............................................................................................................................297
Serial Port Control Table................................................................................................................................299
USB Control Table..........................................................................................................................................301
IDE Control Table............................................................................................................................................302
Diskette Control Table....................................................................................................................................304
Network Interface Control Table....................................................................................................................306
BIOS Setting Table.........................................................................................................................................307
BIOS Group Variable Values.................................................................................................................................310
18 Local Response Agent Group..............................................................................................319
LRA Group Tables.................................................................................................................................................319
LRA Global Settings........................................................................................................................................319
LRA Action Table............................................................................................................................................321
Local Response Agent Variable Values................................................................................................................323
19 Cost of Ownership Group.....................................................................................................325
Cost of Ownership Group Tables..........................................................................................................................325
Cost of Ownership Table................................................................................................................................325
COO Service Contract Table...........................................................................................................................333
COO Cost Event Log Table..............................................................................................................................335
COO Warranty Table......................................................................................................................................337
COO Lease Information Table........................................................................................................................339
COO Schedule Number Table........................................................................................................................341
COO Options Table.........................................................................................................................................343
COO Maintenance Table................................................................................................................................344
COO Repair Table...........................................................................................................................................346
COO Support Information Table.....................................................................................................................348
COO Trouble Ticket Table...............................................................................................................................350
Cost of Ownership Variable Values......................................................................................................................351
20 Remote Access Group..........................................................................................................353
DRAC 4 and DRAC 5..............................................................................................................................................353
Remote Access Table....................................................................................................................................353
DRAC III.................................................................................................................................................................357
Remote Access Table....................................................................................................................................358
Remote User Administration Table................................................................................................................365
Remote SNMP Trap Table..............................................................................................................................371
Remote Dial-Up Table....................................................................................................................................374
Remote User Dial-In Configuration Table......................................................................................................378
Remote Dial-Out Table...................................................................................................................................380
Remote Access Variable Values..........................................................................................................................382
21 Cluster Group ........................................................................................................................393
Cluster Group........................................................................................................................................................393
Cluster Table..................................................................................................................................................393
Cluster Group Variable Values..............................................................................................................................395
22 Baseboard Management Controller Group......................................................................397
Baseboard Management Controller Group Tables...............................................................................................397
Baseboard Management Controller Table.....................................................................................................397
Baseboard Management Controller Serial Interface....................................................................................400
Baseboard Management Controller LAN Interface Table.............................................................................403
Baseboard Management Controller Group Variable Values................................................................................406
23 Field Replaceable Unit Group..............................................................................................409
Field Replaceable Unit Group Tables...................................................................................................................409
Field Replaceable Unit Group Variable Values.....................................................................................................411
24 Storage Management Group...............................................................................................413
Storage Management Group................................................................................................................................413
Storage Management Information Group............................................................................................................414
Global Data Group.................................................................................................................................................415
Physical Devices Group........................................................................................................................................419
Controller Table..............................................................................................................................................419
Channel Table.................................................................................................................................................435
Enclosure Table..............................................................................................................................................439
Array Disk Table.............................................................................................................................................447
Array Disk Enclosure Connection Table........................................................................................................459
Array Disk Channel Connection Table...........................................................................................................461
Fan Table........................................................................................................................................................463
Fan Connection Table.....................................................................................................................................467
Power Supply Table.......................................................................................................................................469
Power Supply Connection Table....................................................................................................................472
Temperature Probe Table..............................................................................................................................474
Temperature Probe Connection Table...........................................................................................................478
Enclosure Management Module Table..........................................................................................................479
Enclosure Management Module Connection Table......................................................................................483
Battery Table..................................................................................................................................................485
Battery Connection Table...............................................................................................................................486
Tape Drive Table............................................................................................................................................488
Logical Devices Group..........................................................................................................................................490
Array Disk Logical Connection Table.............................................................................................................498
Storage Management Event Group......................................................................................................................500
25 Change Management Group...............................................................................................503
Inventory Group....................................................................................................................................................503
Device Group........................................................................................................................................................503
Device Group Table........................................................................................................................................503
Application Group.................................................................................................................................................505
Application Group Table.................................................................................................................................505
Operating System Group.......................................................................................................................................507
Inventory Collector Product Information..............................................................................................................507
26 Dell Remote Access Controller Out-of-Band Group........................................................509
Product Information..............................................................................................................................................509
Chassis Status......................................................................................................................................................512
DRsCMCChangeTime.....................................................................................................................................518
Chassis Power......................................................................................................................................................518
CMC Power Information.......................................................................................................................................519
CMC PSU Information...........................................................................................................................................521
Chassis Alert.........................................................................................................................................................523
Legacy Alerting.....................................................................................................................................................524
27 SNMP Traps...........................................................................................................................527
Trap Variables.......................................................................................................................................................527
Understanding The Trap Description...................................................................................................................529
Understanding Trap Severity................................................................................................................................531
RAC Traps.............................................................................................................................................................532
BMC Traps............................................................................................................................................................534
28 Storage Management Alert Reference.............................................................................539
Alert Monitoring and Logging...............................................................................................................................539
Viewing Alerts.......................................................................................................................................................539
Alert Severity Levels.............................................................................................................................................539
SNMP Support for Storage Management Alerts..................................................................................................540
SNMP Trap Forwarding.................................................................................................................................540
SNMP Trap Definitions...................................................................................................................................540
Trap Variables................................................................................................................................................541
Viewing SNMP Traps............................................................................................................................................543
Alert Descriptions and Corrective Actions...........................................................................................................543
29 iDRAC7 MIB............................................................................................................................545
Supported Systems...............................................................................................................................................545
Blade Servers.................................................................................................................................................545
Rack and Tower Servers................................................................................................................................545
iDRAC7 Supported SNMP Versions......................................................................................................................545
iDRAC7 SNMP Data Security Features.................................................................................................................546
iDRAC7 Out-of-Band Group..................................................................................................................................546
RAC Information Group..................................................................................................................................546
Chassis Information Group.............................................................................................................................548
System Information Group.............................................................................................................................548
Status Group...................................................................................................................................................551
Systems Details Group...................................................................................................................................552
Storage Details Group....................................................................................................................................552
iDRAC7 Traps........................................................................................................................................................553
Trap Variables................................................................................................................................................553
System Trap Group.........................................................................................................................................555
Storage Trap Group........................................................................................................................................563
Updates Trap Group.......................................................................................................................................565
Audit Trap Group............................................................................................................................................565
Configuration Trap Group...............................................................................................................................566
30 Standard Data Type Definitions..........................................................................................567
Common Data Types.............................................................................................................................................567
Variables with Data Types of State Capabilities and State Capabilities Unique..................................................567
Dell Status Data Types..........................................................................................................................................568
Dell Date...............................................................................................................................................................569
Full Dates........................................................................................................................................................570
31 SNMP Sample Output...........................................................................................................571
1

Introduction

This reference guide provides information about the Simple Network Management Protocol (SNMP) Management Information Base (MIB) which is applicable for Dell OpenManage Version 7.
NOTE: This guide contains information that may also be applicable to earlier OpenManage supported platforms.
This introduction is divided into two sections. The first section, Introduction to the SNMP Reference Guide, explains the SNMP Reference Guide design. All essential Simple Network Management Protocol (SNMP) terms are defined in this section. Some of the vocabulary may seem complex and unfamiliar to system administrators who are using SNMP for the first time. SNMP experts can skim this section, and beginners can read the section more carefully.
The second section, Introduction to the Server Administrator SNMP Subagent, is a more technical introduction to the management information base (MIB) that underlies Server Administrator services.

Supported SNMP Versions

Operating System Supported OMSA SNMP version
Windows SNMP v1
Linux SNMP v1

Introduction to the SNMP Reference Guide

This reference guide provides a formatted version of the following Management Information Base that are released with the current version of Dell OpenManage.
Sections in this guide follow MIB groups and provide explanations and definitions for the terms used to define MIB objects. Content in this reference guide is organized as documented in the following subsections.

Server Administrator Instrumentation MIB

The Server Administrator Instrumentation MIB ( filename 10892.mib ) provides instrumentation data that allows you to monitor the health of a system with SNMP management applications. It provides:
Information about the status of temperatures, power supplies, voltages, currents, fans, and memory at key points in the system
Rapid access to detailed fault and performance information gathered by industry standard systems management agents
Version information for Basic Input/Output System (BIOS), firmware, and operating system
A detailed account of every cost of ownership (COO) detail about your system
In addition, traps are sent to report a change in status of the health of critical components.
The Server Administrator Instrumentation MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. The below table describes each Server Administrator Instrumentation MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Instrumentation MIB groups are
11
identified by the SNMP OID 1.3.6.1.4.1.674.10892.1.< number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group.
Table 1. Server Administrator Instrumentation MIB Sections in This Guide
Section Topics MIB Group Numbers
2 Instrumentation MIB Version Group — defines version numbers of
the Instrumentation MIB
3 Systems Management Software Group — defines information
about the systems management software and the supported systems management standards
4 System State Group — defines status, state, and redundancy for a
system and its components
5 Chassis Information Group — defines chassis types, events, and
indicators
6 Operating System Group — defines variables for name, version,
service pack, and other information about a system’s operating system
7 System Resource Group — defines variables for input/output
ports, memory, interrupts, and direct memory access
8 Power Group — defines variables for power units, power supplies,
and their current and voltage probes
9 Thermal Group — defines variables for temperature probes and
cooling devices
10 User Security Group — defines variables for creating and
modifying user accounts
11 Remote Flash BIOS Group — defines variables for updating the
system’s BIOS remotely
12 Port Group — defines variables for major port types such as
keyboard, monitor, small computer system interface (SCSI), Universal Serial Bus (USB), and parallel and serial ports
13 Device Group — defines variables for pointing, keyboard,
processor, cache, memory, and personal computer interface devices
14 Slot Group — defines variables for the system’s slots 1200
15 Memory Group — defines variables for the system’s physical
memory
16 BIOS Setup Control Group — defines variables for BIOS functions
such as boot sequence, speakers, Wake on the local area network (LAN), diskettes, ports, and network interface controllers (NIC)
17 Local Response Agent Group — defines variables for global
settings and actions. These variables allow users to predetermine how the system responds to a particular type of event
18 Cost of Ownership Group — defines variables for tracking data on
the system’s service contract, lease, repair records, trouble tickets, and so on
MIB group number
>, where <
MIB group number
1
100
200
300
400
500
600
700
800
900
1000
1100
1300
1400
1500
1600
> is the MIB group
12
Section Topics MIB Group Numbers
20 Cluster Group — defines variables for systems that operate as a
cluster
21 Baseboard Management Controller Group — provides information
about the Baseboard Management Controller (BMC) that may be present in your system. In addition to providing general information about the BMC, this group provides information about the serial and local area network (LAN) interfaces of the BMC
26 Traps — defines the types of alerts that can be sent to report the
status of critical components
1800
1900
5000

Server Administrator Remote Access MIB

The Server Administrator Remote Access MIB ( filename dcs3rmt.mib ) provides in-band information about remote access hardware that may be present in your system.
The Server Administrator Remote Access MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. Table below describes each Server Administrator Remote Access MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Remote Access MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1.< assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group.
Table 2. Server Administrator Remote Access MIB Sections in This Guide
Section Topic MIB Group Numbers
19 Remote Access Group — provides information about remote
access hardware that may be present in your system and defines variables for administrative users, SNMP trap destinations, modem configuration for dial-up networking, dial-in configuration, and dial-out destinations
MIB group number
> where <
MIB group number
> is the MIB group number
1700

Server Administrator Baseboard Management Controller, ASF MIB

The Server Administrator BMC MIB (filename DcAsfSrv.mib) provides information about the traps sent by BMC. The Server Administrator BMC MIB structures its MIB objects that provide related information. The BMC MIB groups are identified by the SNMP OID 1.3.6.1.4.1.3183.1.1.< hence the enterprise ID is wired for management (3183).
MIB group number
>. The BMC MIB adheres to ASF 2.0 standard and

Server Administrator Field Replaceable Unit MIB

The Server Administrator Field Replaceable Unit MIB (filename dcs3fru.mib) provides information about field replaceable unit (FRU) hardware that may be present in your system.
The Server Administrator Field Replaceable Unit MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. The following table describes each Server Administrator Field Replaceable Unit MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Field Replaceable Unit MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1.< the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group.
MIB group number
> where <
MIB group number
> is
13
Table 3. Server Administrator Field Replaceable Unit MIB Sections in This Guide
Section Topic MIB Group Numbers
22 Field Replaceable Unit Group — provides information about field
replaceable units that may be present in your system
2000

Server Administrator Storage Management MIB

The Server Administrator Storage Management MIB (filename dcstorag.mib) provides storage management data that allows you to monitor the health of storage resources with SNMP management applications.
The following table describes each Server Administrator Storage Management MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Storage Management MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.<MIB group number> where <MIB group number> is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group.
Table 4. Server Administrator Storage Management MIB Sections in This Guide
Section Topics MIB Group Numbers
23 Storage Management Group — consists of definitions for the
following MIB groups:
Storage Management Group
Storage Management Information Group
Global Data Group
Physical Devices Group
Logical Devices Group
Storage Management Event Group
Software Group
10893 NA 20 NA NA 130 140 NA 1
27 Storage Management Alert Reference — lets you monitor the
health of storage resources such as controllers, connectors, array disks, and virtual disks
NA

Server Administrator Change Management MIB

The Server Administrator Change Management MIB (filename dellcm.mib) provides management data that allows you to monitor the inventory of devices and applications with SNMP management applications.
The following table describes each Server Administrator Change Management MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Change Management MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.< MIB group. See the relevant section for more information about the MIB objects defined in a MIB group.
Table 5. Server Administrator Change Management MIB Sections in This Guide
Section Topics MIB Group Number
24 Change Management Group - describes the
MIB group number
inventory data provided by the Change Management MIB that allows users to monitor devices and software present on a particular managed computer chassis
> where <
MIB group number
> is the MIB group number assigned to the
10899
14

Dell Remote Access Controller Out-of-Band MIB

The Dell Remote Access Controller Out-of-Band MIB (filename dellRAC.mib) provides management data that allows you to monitor the Chassis Management Controller. This MIB also contains information on RAC legacy alerting. The following table describes each Dell RAC Out-of-Band group and lists the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group.
Table 6. Dell RAC Out-of-Band MIB
Section Topics MIB Group Number
25 The Dell RAC Out-of-Band MIB consists of information for the
following groups:
Product Information
Chassis Status
Chassis Power
CMC Power Information
CMC PSU Information
Chassis Alerts
Legacy Alerting
2

How This Guide Defines Technical Terms

The following table provides information about where to find definitions for technical terms in this reference guide.
Table 7. Where to Find Definitions for Technical Terms
Type of Definition See
Basic SNMP vocabulary. Introduction
MIB-group-specific variable values. MIB-group-specific MIB variables contain links to the tables that define these values in the last section of the section in which these variables are used.
Systems management terms, acronyms, and commonly managed components referred to in this reference guide.
Server Administrator-standard data types that specify variable values in this reference guide.
Sections 3, 5, 7, 8, 9, and 11 through 18.
Glossary
web site at dell.com/support/manuals.
Appendix A, Standard Data Type Definitions.
available on the Dell Support

Basic Terminology

It is important to have a good understanding of the key technical terms used in this guide. This guide provides definitions for all essential terms used in describing the Server Administrator MIBs. For definitions on all essential terms and acronyms, see the
Glossary
available on the Dell Support website at dell.com/support/manuals.

Frequently Used Terms in Variable Names

The following terms are frequently used in the name of a MIB variable:
Capability refers to the actions an object can perform, or to actions that can be taken by the object. Hot-pluggable is an example of a capability. If a card is hot-pluggable, it can be replaced while a system is running. Capability settings refer
15
to the capabilities of the object that the user can select from and activate if desired. Capability settings allow users of the server administrator to predetermine how an object behaves under specific conditions.
Settings are the conditions of a manageable object that determine what happens when a certain value is detected in a component. For example, a user can set the upper critical threshold of a temperature probe to 75 degrees Celsius. If the probe reaches that temperature, the setting causes an alert to be sent to the management console. Some settings, when reached, can trigger a system shutdown or other response to prevent damage to the system.
State refers to the condition of an object that has more than one condition. For example, an object may be in a or in an
enabled
state.
Status refers to the health of an object or how the object is functioning. For example, the status of a temperature probe that is measuring acceptable temperatures would be reported as normal. When the probe begins reading temperatures that exceed limits set by the user, it reports a critical status.
not ready

Tables

This reference guide contains two types of tables: tables that are used to organize and define variable values and tables that define MIB objects. Readers must understand the difference between these two types of tables.
SNMP Tables
Most of the MIB objects defined in this reference guide are organized into SNMP tables. SNMP tables organize data into two-dimensional structural arrays. In SNMP, objects that have a relationship to other objects are called columnar objects. Columnar objects are objects used to form lists and tables. When a MIB group is divided into one or more
table
discrete tables, the word Universal Unique Identifier (UUID). The UUID object has a type and a value that uniquely identifies an object such as a chassis. The table defines all of the variables that comprise the managed object UUID.
The following table is an example of an SNMP table. The table contains variables that must occur in a definite sequence. In the example table the defined variables are UUID Chassis Index, UUID Index, UUID Type, and UUID Value.
has a technical meaning. An example is the section of this reference guide entitled
These objects comprise the Server Administrator definitions for the UUID.
Table 8. UUID Table
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.20
Description Defines the UUID table.
Syntax SEQUENCE OF UUIDTableEntry
Access Not accessible
Table 9. UUID Table Entry
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1
Description Defines the UUID table entry.
Syntax UUIDTableEntry
Access Not accessible
Index
uUIDTable
uUIDTableEntry
uUIDIndex
16
Table 10. UUID Chassis Index
,
uUIDchassisIndex
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only
Table 11. UUID Index
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.2
Description Defines the index of the UUID in a specified chassis.
Syntax DellObjectRange
Access Read-only
Table 12. UUID Type
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3
Description Defines the type of the UUID for this chassis.
Syntax DellUUIDType
uUIDchassisIndex
uUIDIndex
uUIDType
Access Read-only
Table 13. UUID Value
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4
Description Defines the value of the UUID for this chassis.
Syntax Octet String (SIZE[16])
Access Read-only Read-only
uUIDValue

Section Organization

Sections in this reference guide are based on the Server Administrator MIBs, so the complexity of each section depends on the complexity of each MIB group. The first section provides a high-level introduction to the MIB group. If the group is defined by one or more tables, the second section lists these tables. The third section documents the variables that comprise the group, and if applicable, the variables that comprise the tables. The fourth section contains definitions for any Server Administrator-specific variables that are used in the section. The following example shows the typical content of these four sections:
17
1. BIOS Setup Control Group — This section explains the purpose of the MIB group and summarizes the major features of the component groups.
2. BIOS Group Tables — If there is more than one SNMP table for a group, this section lists all of the tables. For this BIOS group example, there are eight tables listed. In each section, double-clicking any table on the list takes you to that table.
– BIOS Setup Control Table – SCSI Control Table – Parallel Port Control Table – Serial Port Control Table – USB Control Table – IDE Control Table – Diskette Control Table – Network Interface Control Table
3. Variables that make up each table in the group — This section documents the variables for the eight tables that comprise the BIOS group.
4. BIOS Variable Values — This section explains any Server Administrator-specific variables and data types that are used in this section. In the BIOS group example, there are 17 unique, Server Administrator-specific variable meanings. Information on each Server Administrator-specific variable is presented in a formatted table.

Other Documents You May Need

In addition to this guide, you can access the following guides available on the Dell Support website at dell.com/support/ manuals. On the Manuals page, click Software Systems Management. Click the appropriate product link on the right­side to access the documents.
The
Server Administrator Messages Reference Guide
management console or on your operating system’s event viewer. This guide explains the text, severity, and cause of each message that the server administrator issues.
The
Server Administrator CIM Reference Guide
extension of the standard management object format (MOF) file. The Server-Administrator CIM provider documents supported classes of management objects.
The
Glossary
provides information on the terms used in this document.
lists the messages that you can receive on your systems
documents the Common Information Model (CIM) provider, an

Introduction to the Server Administrator SNMP Subagent

This guide provides formatted information drawn primarily from the MIB files written for the Server Administrator services that support the SNMP protocol.
For each of the variables defined in the MIBs, the following fields are specified:
Variable name
OID or unique identifying number
Description
Data type of the variable (for example: integer, string, octet string)
Whether the variable is accessible, not accessible, read-only, or read-write
Index or indexes, if applicable
For each MIB group that has unique variable definitions, tables are included in the last section of the section to explain the meaning of the terms.
Standards for writing MIBs are defined by the Internet Engineering Task Force (IETF). Structure of Management Information (SMI) is a standard that specifies the rules for defining the structure and type of managed objects and
18
events in a MIB. SMIv1 is specified in Request For Comments (RFC) 1155. The Server Administrator MIB conforms to the SMIv1 standard.
SNMP is a systems management standard originally designed for network management. SNMP manages much more than networks. Information Technology (IT) professionals use SNMP for monitoring and managing computer systems and the various components and peripherals supported by their systems.
SNMP standards are defined by the Internet Engineering Task Force (IETF). SNMP version 1 was published in August 1988 and is the most commonly supported version of SNMP. SNMP version 2 was first published in May 1993, but has not gained widespread market acceptance. SNMP version 3 was recently completed and has addressed security issues that exist in version 1.
All SNMP systems consist of one or more managed systems that provide data through an SNMP agent to a management system. The management system provides a user interface to view data from the managed systems. The management system and managed systems communicate over a network (typically through User Datagram Protocol/Internet Protocol [UDP/IP]).
The management system and a managed system communicate by means of a common data schema. SNMP MIB files define the structure, type, and values of the SNMP data. While MIBs can be standardized or enterprise specific, most operating systems supply SNMP agents for the standard MIB-I and MIB-II schemas. MIB-I defines a base set of standard management information for systems implementing the Internet Protocol (IP) suite. MIB-II defines characteristics of the system, characteristics of network interfaces, and characteristics of components of the IP on the system. In addition to the standard MIBs, many hardware vendors have defined MIBs that provide management data specific to their systems and peripheral devices.
Monitored data can be retrieved through SNMP using the Get command. Typically, this command requires the host name or IP address of the target machine as well as the OID of the data to retrieve. Exact details are dependent on the operating system and the development tools being used to create the management application. The Get command has a variant known as GetNext.

Management Information Base Object Identifiers

Each data class within a Management Information Base (MIB) is defined by an Object Identifier (OID). OIDs are unique across all MIBs. An OID consists of a series of digits separated by periods. The OID functions in a similar fashion to a phone number. The phone number 011-512-471-0000 uniquely identifies a single phone. The phone number can be broken down into a number of components to uniquely identify a phone. The first component, 011, is the country code for the United States. The second component, 512, identifies the area code for central Texas. The third component, 471, is the phone exchange for a large state university in the city of Austin. The final component, 0000, is the main switchboard.
There are two main differences between the phone number example and an actual OID. The first difference is that there are many more components in an OID, up to 128. The combination of these components is called an OID prefix. The second difference is that OIDs support the concept of indexes or keys. The OID prefix specifies the data class but does not specify an instance of the data within the class. Indexes can be used to identify the instances of a data class. These indexes are referred to as the OID suffix.
The assignment of values for each OID prefix component can be illustrated by using a tree structure. The following is an example of an OID assignment:
Table 14. ROOT
CCITT(0)
ISO(1)
ORG(3)
DOD(6)
19
INTERNET(1)
MGMT(2)
MIB(1)
EXPERIMENTA L(3)
PRIVATE(4)
ENTERPRISES(
1)
DELL (674)
SNMPv2(6)
In the preceding example, the OID prefix for the Dell enterprise would be 1.3.6.1.4.1.674.
The numbers in boldface type show the categories and numbers that apply to Server Administrator. All Server Administrator-defined OIDs consist of 1.3.6.1.4.1.674 followed by additional component values.

SNMP Security

SNMP version 1 has a very limited security mechanism. SNMP agents support the use of a community string, which is configured at each SNMP agent and is passed as a part of all SNMP request messages. There is no verification that the requester is actually a member of the specified community. As most system and network management data is not confidential, this limited security is acceptable for Get types of requests. On the other hand, this security is not acceptable for Set types of operations where an SNMP request could power off a system, reconfigure a redundant array of independent disks (RAID) card, and so on. Some vendors have chosen not to support SNMP Set operations for this reason. Server Administrator is able to support SNMP Set operations because its SNMP agents implement a hash/ digest mechanism to prevent unauthorized SNMP Set operations. One limitation of this practice is that only server administrator-developed SNMP management applications have the capability to support the hash/digest mechanism.
NOTE: The default SNMP agent configuration usually includes a SNMP community name such as public. For security reasons, change the SNMP community names from their default values. For information about changing SNMP community names, see the Support website at dell.com/support/manuals. For additional guidelines, see the Securing an SNMP Environment article, dated May 2003, in the Dell Power Solutions magazine. This magazine is also available at dell.com/ powersolutions .
NOTE: Server Administrator provides support to enable or disable SNMP Set operations. For more information on enabling or disabling SNMP Set operations in Server Administrator, see the
Administrator User’s Guide
the Dell Support web site at dell.com/support/manuals.
Dell OpenManage Server Administrator User’s Guide
available on the Dell
Dell OpenManage Server
or the
Dell OpenManage Server Administrator Command Line Interface User's Guide

Management Actions

Management actions can be performed using the SNMP Set command. These actions can consist of configuring a phone number for the system’s owner, rebooting a system, or changing the asset tag of the system. See the previous section, Security, for limitations on Set operations.
20
on

SNMP Traps

SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on. Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion. SNMP traps avoid these limitations of the polling method.
An SNMP trap is an asynchronous event indicating that something significant has occurred. This is analogous to a pager receiving an important message, except that the SNMP trap frequently contains all the information needed to diagnose a fault.
Two drawbacks to SNMP traps are that they are sent using UDP, which is not a guaranteed delivery mechanism, and that they are not acknowledged by the receiver.
An SNMP trap message contains the trap’s enterprise OID, the agent IP address, a generic trap ID, the specific trap ID, a time stamp, and zero or more variable bindings (varbinds). The combination of an enterprise OID and a specific trap ID uniquely identifies each Server Administrator-defined trap. A varbind consists of an OID and its value and provides additional information about the trap.
In order for a management system to receive SNMP traps from a managed system, the node must be configured to send traps to the management system. Trap destination configuration is dependent on the operating system. When this configuration is done, a management application on the management system can wait for traps and act on them when received.
For a list of traps supported by the Server Administrator Instrumentation Service, see Instrumentation Traps. For information on Server Administrator Storage Management traps, see Storage Management Alert Reference.
For a list of traps supported by the Remote Access Controller, see RAC Traps, BMC Traps and iDRAC7 Traps.
21
22

Dell OpenManage SNMP Version 7.2

This section contains information added or updated for the current release.

What’s New in This Release

Added support for Enhanced Messaging (EEMI), which includes unique system identifiers (system service tag, chassis service tag, and system FQDN) and message identifier, (Message ID) for enhanced SNMP trap varbinds. You can associate an event to the respective server using the unique system identifiers. For more information, see the
Dell Event Message Reference Guide
Added new varbinds for OpenManage Server Administrator Storage Management:
– Added the following new table for Tape Drive:
Storage Management Group MIB
* tapeDriveTable
* tapeDriveEntry
* tapeDriveNumber
* tapeDriveName
* tapeDriveVendor
* tapeDriveProductID
* tapeDriveNexusID
* tapeDriveBusType
* tapeDriveSASAddress
* tapeDriveMediaType
2
– Added MIB table for Traditional Trap Varbinds: Storage Management Alert MIB
* messageIDEvent
* descriptionEvent
* locationEvent
* objectNameEvent
* objectOIDEvent
* objectNexusEvent
* currentStatusEvent
* previousStatusEvent
– Added MIB table for Trap Enhanced Varbinds:
* enhancedMessageIDEvent
* systemFQDNEvent
* serviceTagEvent
* chassisServiceTagEvent
Added new enhanced varbinds for OpenManage Server Administrator :
23
– Added the following tables for Trap on Traditional and Enhanced Varbinds.
SNMP Traps: Traditional Varbinds:
* alertSystem
* alertTableIndexOID
* alertMessage
* alertCurrentStatus
* alertPreviousStatus
* alertData
Enhanced Varbinds:
* alertMsgID
* alertSystemFQDN
* alertServiceTag
* alertChassisServiceTag
Added support for an additional feature — DIMM ranking, in Memory Module.
Added new enhancements in iDRAC :
– Added new enhancements in iDRAC with SNMP supported version of v2c and v3.
– iDRAC7 MIB
* The iDRAC7 MIB file is now published in both types of SMI (Structure of Managed Information)
notations: SMIv1 and SMIv2. Previously it was only published in SMIv1 notation. Also, the name of the SMIv1 copy of the MIB file has changed. Previously it was named iDRAC-MIB.txt. Now it is named iDRAC-SMIv1.mib. The SMIv2 copy of the MIB file is named iDRAC-SMIv2.mib.
* Updated the lists in the iDRAC7 Supported SNMP Versions section. SNMPv3 queries are now
supported. And the SNMP v2c trap format is now supported.
* Added a new section on iDRAC7 SNMP Data Security Features.
* Added the following three additional new Trap variables:
alertDeviceDisplayNamex
alertMessageArguments
alertChassisServiceTag
* Added the following two new subgroups:
System Details Group
Storage Details Group
* Added the following five new objects under the System Information Group:
systemSystemID
systemOSVersion
systemRoomName
systemChassisSystemHeight
systemBladeGeometry
* Added the following one new object under the Status Group:
systemPowerState
* Added the following two new sets of System Trap Group traps:
Fiber Channel Traps
24
Temperature Statistics Traps
25
26
3

Instrumentation MIB Version Group

The Instrumentation Management Information Base (MIB) Version Group defines the attributes that identify the version of the Instrumentation MIB supported by the systems management software.
The mIBMajorVersionNumber, mIBMinorVersionNumber, and mIBMaintenanceVersionNumber attributes are scalar objects, meaning that they are not related to other MIB objects and are thus not placed in a table.

Management Information Base Major Version Number

Name
Object ID 1.3.6.1.4.1.674.10892.1.1.1.0
Description Defines the major version number of the version of this MIB supported by the
Syntax DellUnsigned8BitRange
Access Read-only
mIBMajorVersionNumber
systems management software. For example, if the MIB version is 1.2.3, the major version number is 1.
A major version number change indicates a major change in object functionality.

Management Information Base Minor Version Number

Name
Object ID 1.3.6.1.4.1.674.10892.1.1.2.0
Description Defines the minor version number of the version of this MIB supported by the
Syntax DellUnsigned8BitRange
Access Read-only
mIBMinorVersionNumber
systems management software. For example, if the MIB version is 1.2.3, the minor version number is 2.
A minor revision provides additional support for new objects as well as problem fixes.

Management Information Base Maintenance Version Number

Name
Object ID 1.3.6.1.4.1.674.10892.1.1.3.0
Description Defines the maintenance version number for the version of this MIB supported by
mIBMaintenanceVersionNumber
the systems management software. For example, if the MIB version is 1.2.3, the maintenance version number is 3.
27
Syntax DellUnsigned8BitRange
Access Read-only
28
4

Systems Management Software Group

The Systems Management Software Group allows users to see information about the standards and software that are supported by the agent of a particular managed computer chassis. The Systems Management Software Group classifies each computer chassis according to the systems management standard that the agent supports.
Additional objects define the universal resource locator (URL) of the systems management software and the language in which systems management information displays. Defining these objects enables users to manage a system using an internet browser. You can access Server Administrator using the secure hypertext transfer protocol (https) and a pre­assigned port number of 1311, or you can specify a port number of your own choosing.
NOTE: Using the SoftwareServer Preferences menu of Server Administrator, you can bind to either one IP address or to all IP addresses.
To manage a system locally using Server Administrator, type the following in the address field of your browser: https:// localhost:<1311 or
To manage a system remotely using Server Administrator, type one of the following in the address field of your browser:
https://<systemname>:<1311 or
number>

Systems Management Software

The following objects describe the fields for server administrator systems management information. The systems management software variables are scalar objects, meaning that they are not related to other management information base (MIB) objects and are thus not placed in a table.
Table 15. Systems Management Software Name
user-specified port number>
user specified port number>
or https://<IP address>:<1311 or
user specified port
Name
Object ID 1.3.6.1.4.1.674.10892.1.100.1
Description Defines the systems management software product name.
Syntax DellString
Access Read-only
Table 16. Systems Management Software Version Number Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.100.2
Description Defines the version number of the systems management software.
Syntax DellString
Access Read-only
systemManagementSoftwareName
systemManagementSoftwareVersionNumberName
29
Table 17. Systems Management Software Build Number
Name
systemManagementSoftwareBuildNumber
Object ID 1.3.6.1.4.1.674.10892.1.100.3
Description Defines the build number of the systems management software.
Syntax DellUnsigned16BitRange
Access Read-only
Table 18. Systems Management Software Description Name
Name
systemManagementSoftwareDescriptionName
Object ID 1.3.6.1.4.1.674.10892.1.100.4
Description Defines the description of the systems management software.
Syntax DellString
Access Read-only
Table 19. Systems Management Software Supported Protocol
Name
systemManagementSoftwareSupportedProtocol
Object ID 1.3.6.1.4.1.674.10892.1.100.5
Description Defines the systems management standards (SNMP or CIM) supported by the
systems management software.
Syntax SMSSupportedTypes (Systems Management Software Supported Standards)
Access Read-only
Table 20. Systems Management Software Preferred Protocol
Name
systemManagementSoftwarePreferredProtocol
Object ID 1.3.6.1.4.1.674.10892.1.100.6
Description Defines the preferred systems management standard for the systems
management software.
Syntax SMSSupportedTypes (Systems Management Software Supported Standards)
Access Read-only
Table 21. Systems Management Software Update Level Name
Name
systemManagementSoftwareUpdateLevelName
Object ID 1.3.6.1.4.1.674.10892.1.100.7
Description Defines the update level of the system management software.
Syntax DellString
Access Read-only
30
Table 22. Systems Management Software URL Name
Name
systemManagementSoftwareURLName
Object ID 1.3.6.1.4.1.674.10892.1.100.8
Description Defines the universal resource locator (URL) of the systems management
software.
Syntax DisplayString (SIZE (0..1024))
Access Read-only
Table 23. Systems Management Software Language Name
Name
systemManagementSoftwareLanguageName
Object ID 1.3.6.1.4.1.674.10892.1.100.9
Description Defines the language of the systems management software.
Syntax DisplayString (SIZE (0..255))
Access Read-only
Table 24. Systems Management Software Global Version Name
Name
systemManagementSoftwareGlobalVersionName
Object ID 1.3.6.1.4.1.674.10892.1.100.10
Description Defines the global version of the systems management software.
Syntax DellString
Access Read-only
Table 25. Systems Management Software Feature Flags
Name
systemManagementSoftwareFeatureFlags
Object ID 1.3.6.1.4.1.674.10892.1.100.11
Description Defines the features of the systems management software.
Syntax SMSFeatureFlags (Systems Management Software Feature Flags)
Access Read-only
Table 26. Systems Management Software SNMP Agent Feature Flags
Name
systemManagementSoftwareSNMPAgentFeatureFlags
Object ID 1.3.6.1.4.1.674.10892.1.100.12
Description Defines the features of the SNMP agent software provided by the operating
system.
Syntax SMSSNMPAgentFeatureFlags (Systems Management Software SNMP Agent
Feature Flags)
Access Read-only
31
Table 27. Systems Management Software Manufacturer Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.100.13
Description Defines the manufacturer of the systems management software.
Syntax DellString
Access Read-only
systemManagementSoftwareManufacturerName

Systems Management Software Variable Values

This section includes definitions of server administrator-specific variable values used in this section.
Table 28. Systems Management Software Supported Standards
Variable Name: SMSSupportedTypes
Data Type: Integer
Possible Data Values Meaning of Data Value
supportsSNMP(1)
supportsDMI(2)
supportsSNMPandDMI(3)
supportsCIMOM(4)
supportsSNMPandCIMOM(5 )
This system supports SNMP.
This system supports DMI.
This system supports SNMP and DMI.
This system supports CIM.
This system supports SNMP and CIM.
Table 29. Systems Management Software Feature Flags
Variable Name: SMSFeatureFlags .
Data Type: Integer
Possible Data Values Meaning of Data Value
none(0)
webOneToOneManagementP referred(1)
Table 30. Systems Management Software SNMP Agent Feature Flags
Variable Name: SMSSNMPAgentFeatureFlags
Data Type: Integer
Possible Data Values Meaning of Data Value
none(0)
supportsSparseTables(1 )
The Systems Management Software features are not enabled.
The web 1:1 management preferred feature is enabled
The Systems Management Software SNMP agent features are not enabled.
The SNMP agent supports sparse tables.
32
5

System State Group

The Management Information Base (MIB) variables presented in this section enable you to track various attributes that describe the state of the critical components supported by your system. Components monitored under the System State Group include power supplies, AC power cords, AC power switches, and cooling devices, as well as temperature, fan, amperage, and voltage probes.

System State Group Table

The System State Group defines objects in the System State MIB table.

System State Table

The systemStateGlobalSystemStatus variable provides overall system health status and includes rolled-up (that is, worst) status for Instrumentation and Storage. This variable monitors the overall system health status. It reflects changes to systemStateChassisStatus variable, which represents Instrumentation health status and agentGlobalSystemStatus (dcstorag.mib), which represents Storage health status.
The systemStateChassisStatus variable provides the rolled-up health status for the subsystems associated with the chassis that is represented by the row in the systemStateTable. Changes to the variables in List 1, each of which indicates the rolled-up health status of all the components of the corresponding subsystem, are reflected in systemStateChassisStatus variable.
For example, systemStatePowerSupplyStatusCombined provides the rolled up status of all power supplies for the chassis.
The variables in List 2 provide the health status of each component of the corresponding subsystem. Each octet of the value represents a component. If a power supply fails, the corresponding entry in systemStatePowerSupplyStatusDetails, systemStatePowerSupplyStatusCombined, systemStateChassisStatus and systemStateGlobalSystemStatus transitions to critical.

List 1

Variables that provide rolled-up health status for all components in associated subsystem in chassis:
systemStatePowerSupplyStatusCombined
systemStateVoltageStatusCombined
systemStateAmperageStatusCombined
systemStateCoolingDeviceStatusCombined
systemStateTemperatureStatusCombined
systemStateMemoryDeviceStatusCombined
systemStateChassisIntrusionStatusCombined
systemStateACPowerCordStatusCombined
systemStateEventLogStatus
systemStatePowerUnitStatusCombined
33
systemStateCoolingUnitStatusCombined
systemStateACPowerSwitchStatusCombined
systemStateRedundantMemoryUnitStatusCombined
systemStateProcessorDeviceStatusCombined
systemStateBatteryStatusCombined
systemStateSDCardUnitStatusCombined
systemStateSDCardDeviceStatusCombined

List 2

Variables that provide health status of each component in associated subsystem in chassis:
systemStatePowerSupplyStatusDetails
systemStateVoltageStatusDetails
systemStateAmperageStatusDetails
systemStateCoolingDeviceStatusDetails
systemStateTemperatureStatusDetails
systemStateMemoryDeviceStatusDetails
systemStateChassisIntrusionStatusDetails
systemStateACPowerCordStatusDetails
systemStatePowerUnitStatusList
systemStateCoolingUnitStatusList
systemStateACPowerSwitchStatusList
systemStateRedundantMemoryUnitStatusList
systemStateProcessorDeviceStatusList
systemStateBatteryStatusList
systemStateSDCardUnitStatusList
systemStateSDCardDeviceStatusList

System State Table

The following object sets up the System State Table:
Table 31. System State Table
Name
Object ID 1.3.6.1.4.1.674.10892.1.200.10
Description Defines the System State Table.
Syntax SEQUENCE OF SystemStateTableEntry
Access Not accessible
Table 32. System State Table Entry
Name
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1
34
systemStateTable
systemStateTableEntry
Description Defines the System State Table entry.
Syntax SystemStateTableEntry
Access Not accessible
Index
Table 33. System State Chassis Index
systemStatechassisIndex
Name
systemStatechassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only
Table 34. System State Global System Status
Name
systemStateGlobalSystemStatus
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.2
Description Defines the global system status of all chassis being monitored by this
instrumentation instance.
Syntax DellStatus
Access Read-only
Table 35. System State Chassis State
Name
systemStateChassisState
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.3
Description Defines the system state of this chassis.
Syntax DellStateSettings
Access Read-only
Table 36. System State Chassis Status
Name
systemStateChassisStatus
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.4
Description Defines the system status of this chassis.
Syntax DellStatus
Access Read-only
35
Table 37. System State Power Unit State Details
Name
systemStatePowerUnitStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.5
Description Defines the state of all power units in this chassis. The results are returned as a
binary octet string. Each byte of the octet string represents the state of a specific power unit. The first byte returned represents the state of the first power unit, the second byte returned represents the state of the second power unit, and so on. The bytes have the same definition type as DellStateSettings.
Syntax Octet String (Size (1..128))
Access Read-only
Table 38. System State Power Unit Status Redundancy
Name
systemStatePowerUnitStatusRedundancy
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.6
Description Defines the system status of the power unit(s) in this chassis.
Syntax DellStatus
Access Read-only
Table 39. System State Power Unit Status Details
Name
systemStatePowerUnitStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.7
Description Defines the status of all power units in this chassis. The results are returned as a
binary octet string. Each byte of the octet string represents the status of a specific power unit. The first byte returned represents the status of the first power unit, the second byte returned represents the status of the second power unit, and so on. The bytes have the same definition type as DellStatusRedundancy.
Syntax Octet String (Size (1..128))
Access Read-only
Table 40. System State Power Supply State Details
Name
systemStatePowerSupplyStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.8
Description Defines the state of all power supplies in this chassis. The results are returned as
a binary octet string. Each byte of the octet string represents the state of a specific power supply. The first byte returned represents the state of the first power supply, the second byte returned represents the state of the second power supply, and so on. The bytes have the same definition type as DellStateSettings.
Syntax Octet String (Size (1..128))
36
Access Read-only
Table 41. System State Power Supply Status Combined
Name
systemStatePowerSupplyStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.9
Description Defines the status of all power supplies in this chassis.
Syntax DellStatus
Access Read-only
Table 42. System State Power Supply Status Details
Name
systemStatePowerSupplyStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.10
Description Defines the status of all power supplies in this chassis. The results are returned as
a binary octet string, Each byte of the octet string represents the status of a specific power supply. The first byte returned represents the status of the first power supply, the second byte returned represents the status of the second power supply, and so on. The bytes have the same definition type as DellStatus.
Syntax Octet String (Size (1..128))
Access Read-only
Table 43. System State Voltage State Details
Name
systemStateVoltageStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.11
Description Defines the state of all voltage probes in this chassis. The results are returned as a
binary octet string. Each byte of the octet string represents the status of a specific voltage probe. The first byte returned represents the status of the first voltage probe, the second byte returned represents the status of the second voltage probe, and so on. The bytes have the same definition type as DellStateSettings.
Syntax Octet String (Size (1..128))
Access Read-only
Table 44. System State Voltage Status Combined
Name
systemStateVoltageStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.12
Description Defines the status of all voltage probes in this chassis.
Syntax DellStatus
Access Read-only
37
Table 45. System State Voltage Status Details
Name
systemStateVoltageStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.13
Description Defines the status of all voltage probes in this chassis.
Syntax Octet String (Size (1..128))
Access Read-only
Table 46. System State Amperage State Details
Name
systemStateAmperageStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.14
Description Defines the state of all current probes in this chassis. The results are returned as a
binary octet string. Each byte of the octet string represents the status of a specific current probe. The first byte returned represents the state of the first current probe, the second byte returned represents the state of the second current probe, and so on. The bytes have the same definition type as DellStateSettings.
Syntax Octet String (Size (1..128))
Access Read-only
Table 47. System State Amperage Status Combined
Name
systemStateAmperageStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.15
Description Defines the status of all amperage probes in this chassis. The result is returned as
a combined status value. The value has the same definition type as DellStatus.
Syntax DellStatus
Access Read-only
Table 48. System State Amperage Status Details
Name
systemStateAmperageStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.16
Description Defines the status of all amperage probes in this chassis. The results are returned
as a binary octet string. Each byte of the octet string represents the status of a specific amperage probe. The first byte returned represents the status of the first amperage probe, the second byte returned represents the status of the second amperage probe, and so on. The bytes have the same definition type as DellStatus.
Syntax Octet String (Size (1..128))
Access Read-only
38
Table 49. System State Cooling Unit State Details
Name
statesystemStateCoolingUnitStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.17
Description Defines the state of all cooling units in this chassis. The results are returned as a
binary octet string. Each byte of the octet string represents the state of a specific cooling unit. The first byte returned represents the state of the first cooling unit, the second byte returned represents the state of the second cooling unit, and so on. The bytes have the same definition type as DellStateSettings.
Syntax Octet String (Size (1..128))
Access Read-only
Table 50. System State Cooling Unit Status Redundancy
Name
systemStateCoolingUnitStatusRedundancy
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.18
Description Defines the state of all cooling units in this chassis.
Syntax DellStatusRedundancy
Access Read-only
Table 51. System State Cooling Unit State Details
Name
systemStateCoolingUnitstateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.19
Description Defines the state of all cooling units in this chassis. The results are returned as a
binary octet string. Each byte of the octet string represents the state of a specific cooling unit. The first byte returned represents the state of the first cooling unit, the second byte returned represents the state of the second cooling unit, and so on. The bytes have the same definition type as DellStateSettings.
Syntax Octet String (Size (1..128))
Access Read-only
Table 52. System State Cooling Device State Details
Name
systemStateCoolingDeviceStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.20
Description Defines the state of all cooling devices in this chassis. The results are returned as
a binary octet string. Each byte of the octet string represents the state of a specific cooling device. The first byte returned represents the state of the first cooling device, the second byte returned represents the state of the second cooling device, and so on. The bytes have the same definition type as DellStateSettings.
Syntax Octet String (Size (1..128))
39
Access Read-only
Table 53. System State Cooling Device Status Combined
Name
systemStateCoolingDeviceStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.21
Description This attribute defines the cooling device status of all cooling devices in this
chassis. The results is returned as a combined status value. The value has the same definition type as DellStatus.
Syntax DellStatus
Access Read-only
Table 54. System State Cooling Device Status Details
Name
systemStateCoolingDeviceStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.22
Description Defines the status of all cooling devices in this chassis. The results are returned
as a binary octet string. Each byte of the octet string represents the status of a specific cooling device. The first byte returned represents the status of the first cooling device, the second byte returned represents the status of the second cooling device, and so on. The bytes have the same definition type as DellStatus.
Syntax Octet String (Size (1..128))
Access Read-only
Table 55. System State Temperature State Details
Name
systemStateTemperatureStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.23
Description Defines the state of all temperature probes in this chassis. The results are
returned as a binary octet string. Each byte of the octet string represents the state of a specific temperature probe. The first byte returned represents the state of the first temperature probe, the second byte returned represents the status of the second temperature probe, and so on. The bytes have the same definition type as DellStateSettings.
Syntax Octet String (Size(1..128))
Access Read-only
Table 56. System State Temperature Status Combined
Name
systemStateTemperatureStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.24
Description Defines the status of all temperature probes in this chassis. The result is returned
as a combined status value. The value has the same definition type as DellStatus.
40
Syntax DellStatus
Access Read-only
Table 57. System State Temperature Status Details
Name
systemStateTemperatureStatusDetailsly
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.25
Description Defines the status of all temperature probes in this chassis. The first byte returned
represents the status of the first temperature probe, the second byte returned represents the status of the second temperature probe, and so on.
Syntax Octet String (Size(1..128)
Access Read-on
Table 58. System State Memory Device State Details
Name
systemStateMemoryDeviceStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.26
Description Defines the state of all memory devices in this chassis. The results are returned as
a binary octet string. Each byte of the octet string represents the state of the specific memory device. The first byte returned represents the state of the first memory device, the second byte returned represents the status of the second memory device, and so on. The bytes have the same definition type as DellStateSettings.
Syntax Octet String (Size(1..128)
Access Read-only
Table 59. System State Memory Device Status Combined
Name
systemStateMemoryDeviceStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.27
Description Defines the status of all memory devices in this chassis.
Syntax DellStatus
Access Read-only
Table 60. System State Memory Device Status Details
Name
systemStateMemoryDeviceStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.28
Description Defines the status of all memory devices in this chassis. The results are returned
as a binary octet string. Each byte of the octet string represents the status of a specific memory device. The first byte returned represents the status of the first memory device, the second byte returned represents the status of the second memory device, and so on. The bytes have the same definition type as DellStatus.
41
Syntax Octet String (Size(1..128)
Access Read-only
Table 61. System State Chassis Intrusion State Details
Name
systemStateChassisIntrusionStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.29
Description Defines the intrusion state of all intrusion detection devices in this chassis. The
results are returned as a binary octet string. Each byte of the octet string represents the status of a specific intrusion detection device. The first byte returned represents the status of the first intrusion detection device, the second byte returned represents the status of the second intrusion detection device, and so on. The bytes have the same definition type as DellStateSettings.
Syntax Octet String (Size(1..128)
Access Read-only
Table 62. System State Chassis Intrusion Status Combined
Name
systemStateChassisIntrusionStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.30
Description Defines the intrusion status of all intrusion detection devices in this chassis. The
result is returned as a combined status value. The value has the same definition type as DellStatus.
Syntax DellStatus
Access Read-only
Table 63. System State Chassis Intrusion Status Details
Name
systemStateChassisIntrusionStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.31
Description Defines the intrusion status of all intrusion detection devices in this chassis. The
first byte returned represents the status of the first intrusion detection device, the second byte returned represents the status of the second intrusion detection device, and so on.
Syntax Octet String (Size(1..128))
Access Read-only
Table 64. System State AC Power Switch State Details
Name
systemStateACPowerSwitchStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.32
42
Description Defines the individual state of all AC power switches in this chassis. The first byte
returned represents the state of the first AC power switch, the second byte returned represents the state of the second AC power switch, and so on.
Syntax Octet String (Size(1..128))
Access Read-only
Table 65. System State AC Power Switch Status Redundancy
Name
systemStateACPowerSwitchStatusRedundancy
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.33
Description Defines the overall redundancy status of the AC power switches in this chassis.
Syntax DellStatusRedundancy
Access Read-only
Table 66. System State AC Power Switch Status Details
Name
systemStateACPowerSwitchStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.34
Description Defines the individual status of all AC power switches in this chassis. The first byte
returned represents the status of the first AC power switch, the second byte returned represents the status of the second AC power switch, and so on.
Syntax Octet String (Size(1..128))
Access Read-only
Table 67. System State AC Power Cord State Details
Name
systemStateACPowerCordStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.35
Description Defines the individual state of all AC power cords for any AC power switches in
this chassis. The first byte returned represents the state of the first AC power cord, the second byte returned represents the state of the second AC power cord, and so on.
Syntax Octet String (Size(1..128))
Access Read-only
Table 68. System State AC Power Cord Status Combined
Name
systemStateACPowerCordStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.36
Description Defines the overall status of all AC power cords for any AC power switches in this
chassis.
Syntax DellStatus
43
Access Read-only
Table 69. System State AC Power Cord Status Details
Name
systemStateACPowerCordStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.37
Description Defines the individual status of all AC power cords for any AC power switches in
this chassis. The first byte returned represents the status of the first AC power cord, the second byte returned represents the status of the second AC power cord, and so on.
Syntax Octet String (SIZE(1..128))
Access Read-only
Table 70. System State Redundant Memory Unit State Details
Name
systemStateRedundantMemoryUnitStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.38
Description Defines the state of all redundant memory units in this chassis. The results are
returned as a binary octet string, each byte of the octet string represents the state of the specific object. The first byte returned represents the state of the first object, and so on. The bytes have the same definition type as DellStateSettings.
Syntax Octet String (Size(1..128))
Access Read-only
Table 71. System State Redundant Memory Unit Status Redundancy
Name
systemStateRedundantMemoryUnitStatusRedundancy
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.39
Description Defines the overall redundancy status for redundant memory.
Syntax DellStatusRedundancy
Access Read-only
Table 72. System State Redundant Memory Unit Status Details
Name
systemStateRedundantMemoryUnitStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.40
Description Defines the status of all redundant memory units in this chassis. The results are
returned as a binary octet string, each byte of the octet string represents the status of the specific object. The first byte returned represents the status of the first object, and so on. The bytes have the same definition type as DellStatusRedundancy.
Syntax Octet String (Size(1..128))
44
Access Read-only
Table 73. System State Event Log Status
Name
systemStateEventLogStatus
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.41
Description Defines the overall status of this chassis (ESM) event log.
Syntax DellStatus
Access Read-only
Table 74. System State Power Unit Status Combined
Name
systemStatePowerUnitStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.42
Description Defines the combined status of all power units of this chassis.
Syntax DellStatus
Access Read-only
Table 75. System State Power Unit Status List
Name
systemStatePowerUnitStatusList
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.43
Description Lists the status of each power unit of this chassis. The results are returned as a
binary octet string where each byte of the octet string represents the status of a power unit. The first byte returned represents the status of the first power unit, and so on. The bytes have the same definition type as DellStatus.
Syntax Octet String (Size(1..128))
Access Read-only
Table 76. System State Cooling Unit Status Combined
Name
systemStateCoolingUnitStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.44
Description Defines the combined status of all cooling units of this chassis.
Syntax DellStatus
Access Read-only
Table 77. System State Cooling Unit Status List
Name
systemStateCoolingUnitStatusList
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.45
45
Description Lists the status of each cooling unit of this chassis. The results are returned as a
binary octet string where each byte of the octet string represents the status of a cooling unit. The first byte returned represents the status of the first cooling unit, and so on. The bytes have the same definition type as DellStatus.
Syntax Octet String (Size(1..128))
Access Read-only
Table 78. System State AC Power Switch Status Combined
Name
systemStateACPowerSwitchStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.46
Description Defines the combined status of all AC power switches of this chassis.
Syntax DellStatus
Access Read-only
Table 79. System State AC Power Switch Status List
Name
systemStateACPowerSwitchStatusList
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.47
Description Lists the status of each AC power switch of this chassis. The results are returned
as a binary octet string where each byte of the octet string represents the status of an AC power switch. The first byte returned represents the status of the first AC power switch, and so on. The bytes have the same definition type as DellStatus.
Syntax Octet String (Size(1..128))
Access Read-only
Table 80. System State Redundant Memory Unit Status Combined
Name
systemStateRedundantMemoryUnitStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.48
Description Defines the combined status of all redundant memory units of this chassis.
Syntax DellStatus
Access Read-only
Table 81. System State Redundant Memory Unit Status List
Name
systemStateRedundantMemoryUnitStatusList
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.49
Description Lists the status of each redundant memory unit of this chassis. The results are
returned as a binary octet string where each byte of the octet string represents the status of a redundant memory unit. The first byte returned represents the status of the first redundant memory unit, and so on. The bytes have the same definition type as DellStatus.
46
Syntax Octet String (Size(1..128))
Access Read-only
Table 82. System State Processor Device Status Combined
Name
systemStateProcessorDeviceStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.50
Description Defines the combined status of all processor devices of this chassis.
Syntax DellStatus
Access Read-only
Table 83. System State Processor Device Status List
Name
systemStateProcessorDeviceStatusList
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.51
Description Lists the status of each processor device of this chassis. The results are returned
as a binary octet string where each byte of the octet string represents the status of a processor device. The first byte returned represents the status of the first processor device, and so on. The bytes have the same definition type as DellStatus.
Syntax Octet String (Size(1..128))
Access Read-only
Table 84. System State Battery Status Combined
Name
systemStateBatteryStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.52
Description Defines the combined status of all batteries of this chassis.
Syntax DellStatus
Access Read-only
Table 85. System State Battery Status List
Name
systemStateBatteryStatusList
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.53
Description Lists the status of each battery of this chassis. The results are returned as a binary
octet string where each byte of the octet string represents the status of a battery. The first byte returned represents the status of the first battery, and so on. The bytes have the same definition type as DellStatus.
Syntax Octet String (Size(1..128))
Access Read-only
47
Table 86. System State SD Card Unit Status Combined
Name
systemStateSDCardUnitStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.54
Description Defines the combined status of all SD Card units of this chassis.
Syntax DellStatus
Access Read-only
Table 87. System State SD Card Unit Status List
Name
systemStateSDCardUnitStatusList
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.55
Description Lists the status of each SD Card unit of this chassis. The results are returned as a
binary octet string where each byte of the octet string represents the status of a SD Card unit. The first byte returned represents the status of the first SD Card unit, and so on. The bytes have the same definition type as DellStatus.
Syntax Octet String (Size(1..128))
Access Read-only
Table 88. System State SD Card Device Status Combined
Name
systemStateSDCardDeviceStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.56
Description Defines the combined status of all SD Card devices of this chassis.
Syntax DellStatus
Access Read-only
Table 89. System State SD Card Device Status List
Name
systemStateSDCardDeviceStatusList
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.57
Description Lists the status of each SD Card device of this chassis. The results are returned as
a binary octet string where each byte of the octet string represents the status of a SD Card device. The first byte returned represents the status of the first SD Card device, and so on. The bytes have the same definition type as DellStatus.
Syntax Octet String (Size(1..128))
Access Read-only
48
6

Chassis Information Group

The Chassis Information Group objects provide information about the modular chassis in which a blade system resides.
NOTE: This Chassis information is only available for modular/blade systems. For Rack and Tower systems, the information is empty. Currently there is just one object under the Chassis Information Group.
Table 90. Chassis Service Tag
Name
Object ID 1.3.6.1.4.1.674.10892.5.1.2.1.0
chassisServiceTag
This attribute defines the service tag of the enclosing chassis.
StringType
Read-only

Chassis Information Group Tables

The following management information base (MIB) tables define the objects in the Chassis Information Group:
Chassis Information Table
UUID Table
POST Log Table
Event Log Table
System BIOS Table
Firmware Table
Intrusion Table
Baseboard Table

Chassis Information Table

The following object sets up the Chassis Information Table.
Table 91. Chassis Information Table
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10
Description Defines the chassis information table.
Syntax SEQUENCE OF ChassisInformationTableEntry
Access Not accessible
chassisInformationTable
49
Chassis Information Table Entry
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1
Description Defines the chassis information table entry.
Syntax ChassisInformationTableEntry
Access Not accessible
Index
chassisInformationTableEntry
chassisIndexChassisInformation
Chassis Index Chassis Information
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.1
Description Defines the index (one-based) of this chassis. The first chassis is numbered one.
Syntax DellObjectRange
Access Read-only
chassisIndexChassisInformation
Chassis State Capabilities
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.2
Description Defines the capabilities of the chassis.
chassisStateCapabilities
Syntax DellStateCapabilities
Access Read-only
Chassis State Settings
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.3
Description Defines the state settings for the chassis.
Syntax DellStateSettings
Access Read-write
chassisStateSettings
Chassis Status
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4
Description Defines the status of the chassis.
Syntax DellStatus
Access Read-only
chassisStatus
50
Chassis Parent Index Reference
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4
Description Defines the index (one-based) of the parent chassis of this chassis, if any. A zero
Syntax DellObjectRange
Access Read-only
chassisparentIndexReference
(0) means that this chassis is the parent of all other chassis managed by the Server Administrator.
Chassis Type
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.6
Description Defines the chassis type.
Syntax DellChassisType (See )
Access Read-only
chassisType
Chassis Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.7
chassisName
Description Defines the user-assigned chassis name of the chassis.
Syntax DellString
Access Read-write
Chassis Manufacturer Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.8
Description Defines the manufacturer’s name for this chassis.
Syntax DellString
Access Read-only
chassisManufacturerName
Chassis Model Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.9
Description Defines the system model type for this chassis.
Syntax DellString
Access Read-only
chassisModelName
51
Chassis Asset Tag Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.10
Description Defines the user-assigned asset tag name for this chassis.
Syntax DisplayString (SIZE (0..10))
Access Read-write
chassisAssetTagName
Chassis Service Tag Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.11
Description Defines the service tag name for this chassis.
Syntax DisplayString (SIZE (0..7))
Access Read-only
chassisServiceTagName
Chassis ID
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.12
Description Defines the asset tag name for this chassis.
Syntax DellUnsigned8BitRange
chassisID
Access Read-only
Chassis ID Extension
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.13
Description Defines the SMBIOS machine ID of this chassis.
Syntax DellUnsigned16BitRange
Access Read-only
chassisIDExtension
Chassis System Class
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.14
Description Defines the chassis class of this chassis.
Syntax DellChassisSystemClass (See Chassis Type)
Access Read-only
chassisSystemClass
52
Chassis System Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.15
Description Defines the system name of this chassis.
Syntax DellString
Access Read-only
chassisSystemName
Chassis System Boot Date Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.16
Description Defines the boot time of this system.
Syntax DellDateName
Access Read-only
chassisSystemBootDateName
Chassis System Date Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.17
Description Defines the current time on this system.
Syntax DellDateName
chassisSystemDateName
Access Read-only
Chassis System Location Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.18
Description Defines the user-assigned location for this chassis.
Syntax DellString
Access Read-write
chassisSystemLocationName
Chassis System Primary User Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.19
Description Defines the user-assigned primary user name for this chassis.
Syntax DellString
Access Read-write
chassisSystemPrimaryUserName
53
Chassis System User Phone Number Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.20
Description Defines the user-assigned phone number of the primary user of the system.
Syntax DellString
Access Read-write
chassisSystemUserPhoneNumberName
Chassis Connection Status Unique
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.21
Description Defines the status of the connection from the system chassis to an expansion
Syntax DellConnectionStatus (See Connection Status)
Access Read-only
chassisConnectionStatusUnique
chassis.
Chassis Fan Control Capabilities Unique
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.22
Description Defines the capabilities of the fan control function in this chassis.
chassisFanControlCapabilitiesUnique
Syntax DellFanControlCapabilities (See Fan Control Capabilities)
Access Read-only
Chassis Fan Control Settings Unique
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.23
Description Defines the readings and settings of the fan control hardware in the chassis.
Syntax DellFanControlSettings
Access Read-write
chassisFanControlSettingsUnique
Chassis LED Control Capabilities Unique
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.24
Description Defines the capabilities of the LED control function in the chassis.
Syntax DellLEDControlCapabilities (See Front-Panel LED Control CapabilitiesVariable)
Access Read-only
chassisLEDControlCapabilitiesUnique
54
Chassis LED Control Settings Unique
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.25
Description Defines the readings and settings of the LED control hardware in the chassis.
Syntax DellLEDControlSettings (See Front-Panel LED Control Settings)
Access Read-write
chassisLEDControlSettingsUnique
Chassis Hard-Drive (HD) Fault Clear Control Capabilities
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.26
Description Specifies whether the chassis allows reset of the chassis hard-drive fault LED.
Syntax DellHDFaultLEDControlCapabilities (See Hard-Drive Fault LED Control Capabilities )
Access Read-only
chassisHDFaultClearControlCapabilities
Chassis HD Fault Clear Control Settings
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.27
Description Allows reset of the chassis hard-drive fault LED.
Syntax DellHDFaultLEDControlSettings (See Hard-Drive Fault LED Control Settings)
chassisHDFaultClearControlSettings
Access Read-write
Chassis Identify Flash Control Capabilities
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.28
Description Specifies whether the chassis front-panel LED can be set to flash.
Syntax DellChassisIdentifyControlCapabilities (See Chassis Identification Control
Access Read-only
chassisIdentifyFlashControlCapabilities
Capabilities)
Chassis Identify Flash Control Settings
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.29
Description Causes the chassis front-panel LED to flash.
Syntax DellChassisIdentifyControlSettings (See Chassis Identification Control Capabilities)
Access Read-write
chassisIdentifyFlashControlSettings
55
Chassis Lock Present
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.30
Description Specifies whether a chassis lock is present on the chassis.
Syntax DellBoolean
Access Read-only
chassisLockPresent
Chassis Host Control Capabilities Unique
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.31
Description Defines the capabilities of the host control object.
Syntax DellHostControlCapabilities (See Host Control Capabilities)
Access Read-only
chassishostControlCapabilitiesUnique
Chassis Host Control Settings Unique
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.32
Description Defines the current settings of the host control object.
Syntax DellHostControlSettings (See Host Control Settings)
chassishostControlSettingsUnique
Access Read-write
Chassis Watchdog Control Capabilities Unique
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.33
Description Defines the capabilities of the watchdog timer object.
Syntax DellWatchDogControlCapabilities (See Watchdog Control Capabilities)
Access Read-only
chassiswatchDogControlCapabilitiesUnique
Chassis Watchdog Control Settings Unique
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.34
Description Defines the current settings and the values allowed to be set for the watchdog
Syntax DellWatchDogControlCapabilities (See Watchdog Control Capabilities)
Access Read-write
chassiswatchDogControlSettingsUnique
timer object.
56
Chassis Watchdog Control Expiry Time Capabilities Unique
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.35
Description Defines the capabilities of the watchdog expiry timer object.
Syntax DellWatchDogTimerCapabilities (See Watchdog Timer Capabilities)
Access Read-only
chassiswatchDogControlExpiryTimeCapabilitiesUnique
Chassis Watchdog Control Expiry Time
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.36
Description Defines the current reading and allows setting of the nonrecoverable watchdog
Syntax DellUnsigned16BitRange
Access Read-write
chassiswatchDogControlExpiryTime
expiry timer object.
Chassis Allow Set Commands From SNMP
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.37
Description Specifies whether Simple Network Management Protocol (SNMP) Set type
chassisallowSETCommandsfromSNMP
commands are allowed by Server Administrator. This attribute does not reflect whether SNMP Set type commands are allowed by the SNMP master agent.
Syntax DellBoolean
Access Read-only
Chassis Power Button Control Capabilities Unique
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.38
Description Defines the capabilities of the power button control function.
Syntax DellPowerButtonControlCapabilities (See Power Button Control Capabilities)
Access Read-only
chassisPowerButtonControlCapabilitiesUnique
Chassis Power Button Control Settings Unique
Name
Object ID . 1.3.6.1.4.1.674.10892.1.300.10.1.39
Description Defines the current reading and allows setting of the power button control
chassisPowerButtonControlSettingsUnique
hardware
57
Syntax DellPowerButtonControlSettings (See Power Button Control Settings)
Access Read-write
Chassis Reseller Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.40
Description Defines the name of the chassis reseller.
Syntax DisplayString (SIZE (0..128))
Access Read-only
chassisResellerName
Chassis Reseller Contact Information Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.41
Description Defines the chassis reseller contact information name.
Syntax DisplayString (SIZE (0..128))
Access Read-only
chassisResellerContactInformationName
Chassis Reseller Product Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.42
Description Defines the chassis reseller product name.
Syntax DisplayString (SIZE (0..128))
chassisResellerProductName
Access Read-only
Chassis Reseller System ID
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.43
Description Defines the chassis reseller system ID.
Syntax DellUnsigned16BitRange
Access Read-only
chassisResellerSystemID
Chassis NMI Button Control Capabilities Unique
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.44
Description Defines the capabilities of the NMI button control function.
Syntax DellNMIButtonControlCapabilities (See NMI Button Control Capabilities)
58
chassisNMIButtonControlCapabilitiesUnique
Access Read-only
Chassis NMI Button Control Settings Unique
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.45
Description Defines the current reading and allows setting of the NMI button control
Syntax DellNMIButtonControlSettings (See NMI Button Control Settings)
Access Read-write
chassisNMIButtonControlSettingsUnique
hardware.
Chassis System Properties
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.46
Description Defines the properties of the system.
Syntax DellSystemProperties (See System Properties)
Access Read-only
chassisSystemProperties
Chassis System Revision Number
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.47
Description Defines the revision number of the system where zero indicates the original
chassisSystemRevisionNumber
version of the system. The revision number is not available on all systems.
Syntax DellUnsigned8BitRange
Access Read-only
Chassis System Revision Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.48
Description Defines the revision name of the system, if applicable.
Syntax DellString
Access Read-only
chassisSystemRevisionName
Chassis Express Service Code Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.49
Description Defines the express service code of the chassis.
Syntax DellString
chassisExpressServiceCodeName
59
Access Read-only

UUID Table

These objects comprise the server administrator definitions for the Universal Unique Identifier (UUID).
Table 92. UUID Table
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.20
Description Defines the UUID table.
Syntax SEQUENCE OF UUIDTableEntry
Access Not accessible
Table 93. UUID Table Entry
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1
Description Defines the UUID table entry.
Syntax UUIDTableEntry
Access Not accessible
Index
Table 94. UUID Chassis Index
Name
uUIDTable
uUIDTableEntry
uUIDIndex
,
uUIDchassisIndex
uUIDchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only
Table 95. UUID Index
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.2
Description Defines the index of the UUID in a specified chassis.
Syntax DellObjectRange
Access Read-only
60
uUIDIndex
Table 96. UUID Type
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3
Description Defines the type of the UUID for this chassis.
Syntax DellUUIDType
Access Read-only
Table 97. UUID Value
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4
Description Defines the value of the UUID for this chassis.
Syntax Octet String (SIZE(16))
Access Read-only
uUIDType
uUIDValue

POST Log Table

This section defines attributes for the power-on self-test (POST) log. When you turn on your computer, the POST checks various system components before the operating system loads. The POST tests the random-access memory (RAM), the hard drives, and the keyboard, for example. While the POST is running, it makes a log file that system administrators can view. The variables in this section also contribute to managing the POST log.
Table 98. POST Log Table
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.30
Description Defines the POST Log Table.
Syntax SEQUENCE OF PostLogTableEntry
Access Not accessible
Table 99. POST Log Table Entry
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.30.1
Description Defines the POST Log Table entry.
Syntax PostLogTableEntry
Access Not accessible
Index
postLogTable
postLogTableEntry
postLogchassisIndex
,
postLogRecordIndex
61
Table 100. POST Log Chassis Index
Name
postLogchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only
Table 101. POST Log Record Index
Name
postLogRecordIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.2
Description Defines the record number (one-based) of the POST log.
Syntax DellUnsigned32BitRange
Access Read-only
Table 102. POST Log State Capabilities Unique
Name
postLogStateCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.3
Description Defines the capabilities of the object that is writing the POST log.
Syntax DellStateCapabilitiesLogUnique
Access Read-only
Table 103. POST Log State Settings Unique
Name
postLogStateSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.4
Description Defines the state of the object that is writing the POST log.
Syntax DellStateSettingsLogUnique
Access Read-write
Table 104. POST Log Record
Name
postLogRecord
Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5
Description Defines the data for the specified chassis and record index in the POST log being
returned.
Syntax DisplayString (SIZE (0..1024))
Access Read-only
62
Table 105. POST Log Format
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5
Description Defines format of the POST log.
Syntax DellLogFormat (See Log Format)
Access Read-only
postLogFormat

Event Log Table

Table 106. Event Log Table
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.40
Description Defines the Event Log Table.
Syntax SEQUENCE OF EventLogTableEntry
Access Not accessible
Table 107. Event Log Table Entry
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.40.1
eventLogTableEntry
eventLogTableEntry
Description Defines the event Log Table Entry.
Syntax EventLogTableEntry
Access Not accessible
Index
Table 108. Event Log Chassis Index
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only
Table 109. Event Log Record Index
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.2
eventLogchassisIndex
,
eventLogRecordIndex
eventLogchassisIndex
eventLogRecordIndex
63
Description Defines the record index of the event log.
Syntax DellUnsigned32BitRange
Access Read-only
Table 110. Event Log State Capabilities Unique
Name
eventLogStateCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.3
Description Defines the capabilities of the object that is writing the event log.
Syntax DellStateCapabilitiesLogUnique
Access Read-only
Table 111. Event Log State Settings Unique
Name
eventLogStateSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.4
Description Defines the state settings for the object that is writing the event log.
Syntax DellStateSettingsLogUnique
Access Read-write
Table 112. Event Log Record
Name
eventLogRecord
Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.5
Description Defines the data for the specified chassis and log record index in the event log
being returned.
Syntax DisplayString (SIZE (0..1024))
Access Read-only
Table 113. Event Log Format
Name
eventLogFormat
Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.6
Description Defines the format of the event log.
Syntax DellLogFormat (See Log Format)
Access Read-only
Table 114. Event Log Severity Status
Name
eventLogSeverityStatus
Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.7
64
Description Defines the severity of the event log record.
Syntax DellStatus
Access Read-only
Status Mandatory
Table 115. Event Log Date Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.8
Description Defines the date and time of the event log record.
Syntax DellDateName
Access Read-only
Status Mandatory
eventLogDateName

System BIOS Table

This table lists objects that define the system’s basic input/output system (BIOS).
Table 116. System BIOS Table
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.50
Description Defines the System BIOS Table.
Syntax SEQUENCE OF SystemBIOSTableEntry
Access Not accessible
Table 117. System BIOS Table Entry
systemBIOSTable
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1
Description Defines the System BIOS Table entry.
Syntax SystemBIOSTableEntry
Access Not accessible
Index
Table 118. System BIOS Chassis Index
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.1
systemBIOSTableEntry
systemBIOSchassisIndex
,
systemBIOSIndex
systemBIOSchassisIndex
65
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only
Table 119. System BIOS Index
Name
systemBIOSIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.2
Description Defines the index (one-based) of the system BIOS of this object.
Syntax DellObjectRange
Access Read-only
Table 120. System BIOS State Capabilities
Name
systemBIOSStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.3
Description Defines the capabilities of the system BIOS of this object.
Syntax DellStateCapabilities
Access Read-only
Table 121. System BIOS State Settings
Name
systemBIOSStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.4
Description Defines the state of the system BIOS of this object.
Syntax DellStateSettings
Access Read-write
Table 122. System BIOS Status
Name
systemBIOSStatus
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.5
Description Defines the status of the system BIOS of this object.
Syntax DellStatus
Access Read-only
Table 123. System BIOS Size
Name
systemBIOSSize
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.6
66
Description Defines the image size of the system BIOS in kilobytes (KB). A zero (0) indicates
that the image size of the BIOS is unknown.
Syntax DellUnsigned32BitRange
Access Read-only
Table 124. System BIOS Release Date Name
Name
systemBIOSReleaseDateName
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.7
Description Defines the release date of the system BIOS.
Syntax DellDateName
Access Read-only
Table 125. System BIOS Version Name
Name
systemBIOSVersionName
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.8
Description Defines the version name of the system BIOS.
Syntax DellString
Access Read-only
Table 126. System BIOS Starting Address
Name
systemBIOSStartingAddress
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.9
Description Defines the starting address of the system BIOS. A zero (0) indicates that the
address is unknown.
Syntax DellUnsigned64BitRange
Access Read-only
Table 127. System BIOS Ending Address
Name
systemBIOSEndingAddress
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.10
Description Defines the ending address of the system BIOS. A zero (0) indicates that the
address is unknown.
Syntax DellUnsigned64BitRange
Access Read-only
67
Table 128. System BIOS Manufacturer Name
Name
systemBIOSManufacturerName
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.11
Description Defines the system BIOS manufacturer’s name.
Syntax DellString
Access Read-only
Table 129. System BIOS Characteristics
Name
systemBIOSCharacteristics
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.12
Description
Defines characteristics of the system BIOS. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one). Bit 63 is the first bit in the value, and bit 0 is the last bit in the value. See the description of DellUnsigned64BitRange at the beginning of this file for more information on the format of the value.
Bits 48-63 need to be examined in the context of the system ID. The system ID is available in the attribute chassisID. If the value for chassisID is non-zero, bits 48-63 have the meaning defined below
Bit Position Meaning if Set
Bit 0 Reserved
Bit 1 Reserved
Bit 2 Unknown
Bit 3 BIOS Characteristics Not Supported
Bit 4 ISA is supported
Bit 5 MCA is supported
Bit 6 EISA is supported
Bit 7 PCI is supported
Bit 8 PC Card (PCMCIA) is supported
Bit 9 Plug and Play is supported
Bit 10 APM is supported
Bit 11 BIOS is Upgradeable (Flash)
Bit 12 BIOS shadowing is allowed
Bit 13 VL-VESA is supported
Bit 14 ESCD support is available
Bit 15 Boot from CD is supported
Bit 16 Selectable Boot is supported
Bit 17 BIOS ROM is socketed
Bit 18 Boot From PC Card (PCMCIA) is
supported
68
Bit 19 EDD (Enhanced Disk Drive)
Specification is supported
Bit 20 Int 13h - Japanese Floppy for NEC 9800
1.2mb (3.5 in, 1k Bytes/Sector, 360 RPM) is supported
Bit 21 Int 13h - Japanese Floppy for Toshiba
1.2mb (3.5 in, 360 RPM) is supported
Bit 22 Int 13h - 5.25 in / 360 KB Floppy
Services are supported
Bit 23 Int 13h - 5.25 in /1.2MB Floppy
Services are supported
Bit 24 Int 13h - 3.5 in / 720 KB Floppy Services
are supported
Bit 25 Int 13h - 3.5 in / 2.88 MB Floppy
Services are supported
Bit 26 Int 5h, Print Screen Service is
supported
Bit 27 Int 9h, 8042 Keyboard services are
supported
Bit 28 Int 14h, Serial Services are supported
Bit 29 Int 17h, Printer Services are supported
Bit 30 Int 10h, CGA/Mono Video Services are
supported
Bit 31 NEC PC-98
Bit 32 -47Reserved
Bit 48 Built-in NIC supports Magic Packet
Bit 49 System supports Wake-on-LAN
Bit 50 System supports chassis intrusion
Bit 51 Built-in NIC supports pattern-matching
Bit 52 System BIOS supports a 7-character
service tag
Bit 53 -63 Reserved
Syntax DellUnsigned64BitRange
Table 130. System BIOS Characteristics Ext 1
Name
systemBIOSCharacteristicsExt1
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.13
Description
Defines additional characteristics of the system basic input/output system (BIOS). This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
Bit Position Meaning if Set
Bit 0 ACPI supported
69
Bit 1 USB Legacy is supported
Bit 2 AGP is supported
Bit 3 I2O boot is supported
Bit 4 LS-120 boot is supported
Bit 5 ATAPI ZIP Drive boot is supported
Bit 6 1394 boot is supported
Bit 7 Smart Battery supported
Syntax DellUnsigned8BitRange
Access Read-only
Table 131. System BIOS Characteristics Ext 2
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.14
Description
Syntax DellUnsigned8BitRange
Access Read-only
systemBIOSCharacteristicsExt2
Defines additional characteristics of the system BIOS. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
Bit Position Meaning if Set
Bit 0 BIOS Boot Specification supported
Bit 1 Function key-initiated Network
Bit 2 Targeted Content Distribution
Bit 3 7Reserved

Firmware Table

Table 132. Firmware Table
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.60
Description Defines the Firmware Table.
Syntax SEQUENCE OF FirmwareTableEntry
Access Not accessible
firmwareTable
Service boot supported
supported
Table 133. Firmware Table Entry
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1
70
firmwareTableEntry
Description Defines the Firmware Table entry
Syntax FirmwareTableEntry
Access Not accessible
Index
firmwarechassisIndex
,
firmwareIndex
Table 134. Firmware Chassis Index
Name
firmwarechassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only
Table 135. Firmware Index
Name
firmwareIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.2
Description Defines the index (one-based) of the firmware in this chassis.
Syntax DellObjectRange
Access Read-only
Table 136. Firmware State Capabilities
Name
firmwareStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.3
Description Defines the capabilities of the firmware states.
Syntax DellStateCapabilities
Access Read-only
Table 137. Firmware State Capabilities
Name
firmwareStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.4
Description Defines the state of the firmware and allows for the setting of the firmware.
Syntax DellStateCapabilities
Access Read-write
Table 138. Firmware Status
Name
firmwareStatus
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.5
71
Description Defines the status of the firmware.
Syntax DellStateSettings
Access Read-only
Table 139. Firmware Size
Name
firmwareSize
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.6
Description Defines the image size of the firmware in KB. A zero (0) indicates that the size is
unknown.
Syntax DellUnsigned16BitRange
Access Read-only
Table 140. Firmware Type
Name
firmwareType
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.7
Description Defines the type of the firmware.
Syntax DellFirmwareType
Access Read-only
Table 141. Firmware Type Name
Name
firmwareTypeName
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.8
Description Defines the name of firmware type.
Syntax DellString
Access Read-only
Table 142. Firmware Update Capabilities
Name
firmwareUpdateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.9
Description Defines the bitmap of supported methods for firmware update.
Syntax DellUnsigned16BitRange
Access Read-only
Table 143. Firmware Date Name
Name
firmwareDateName
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.10
Description Defines the date of the firmware.
Syntax DellDateName
72
Access Read-only
Table 144. Firmware Version Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.11
Description Defines the version name of the firmware.
Syntax DellString
Access Read-only
firmwareVersionName

Intrusion Table

The following objects and attributes describe the different forms of chassis intrusion, a situation that occurs when the cover of a computer is removed.
Table 145. Intrusion Table
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.70
Description Defines the Intrusion Table.
Syntax SEQUENCE OF IntrusionTableEntry
Access Not accessible
Table 146. Intrusion Table Entry
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1
Description Defines the Intrusion Table entry.
Syntax IntrusionTableEntry
Access Not accessible
Index
intrusionTable
intrusionTableEntry
intrusionchassisIndex
,
intrusionIndex
Table 147. Intrusion Chassis Index
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only
intrusionchassisIndex
73
Table 148. Intrusion Index
Name
intrusionIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.2
Description Defines the index of the intrusion objects in this subgroup.
Syntax DellObjectRange
Access Read-only
Table 149. Intrusion State Capabilities
Name
intrusionStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.3
Description Defines the capabilities of the intrusion object.
Syntax DellStateCapabilities
Access Read-only
Table 150. Intrusion State Settings
Name
intrusionStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.4
Description Defines the settings of the intrusion object.
Syntax DellStateSettings
Access Read-write
Table 151. Intrusion Status
Name
intrusionStatus
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.5
Description Defines the status of the intrusion object.
Syntax DellStatus
Access Read-only
Table 152. Intrusion Reading
Name
intrusionReading
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.6
Description Defines the reading of the intrusion object.
Syntax DellIntrusionReading
Access Read-only
Table 153. Intrusion Type
Name
intrusionType
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.7
74
Description Defines the type of the intrusion object.
Syntax DellIntrusionType
Access Read-only
Table 154. Intrusion Location Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.8
Description Defines the location name of the intrusion object in this subgroup.
Syntax DellString
Access Read-only
intrusionLocationName

Baseboard Table

This table lists objects that define the baseboard of a system.
Table 155. Baseboard Table
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.80
Description Defines the Baseboard Table.
Syntax SEQUENCE OF BaseBoardTableEntry
Access Not accessible
Table 156. Baseboard Table Entry
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1
Description Defines the Baseboard Table entry.
Syntax BaseBoardTableEntry
Access Not accessible
Index
baseBoardTable
baseBoardTableEntry
baseBoardChassisIndex
,
baseBoardIndex
Table 157. Baseboard Chassis Index
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only
baseBoardchassisIndex
75
Table 158. Baseboard Index
Name
baseBoardIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.2
Description Defines the index (one-based) of the base board.
Syntax DellObjectRange
Access Read-only
Table 159. Baseboard State Capabilities
Name
baseBoardStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.3
Description Defines the state capabilities of the baseboard.
Syntax DellStateCapabilities
Access Read-only
Table 160. Baseboard State Settings
Name
baseBoardStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.4
Description Defines the state settings of the baseboard.
Syntax DellStateSettings
Access Read-write
Table 161. Baseboard Status
Name
baseBoardStatus
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.5
Description Defines the status of the baseboard.
Syntax DellStatus
Access Read-only
Table 162. Baseboard Feature Flags
Name
baseBoardFeatureFlags
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.6
Description Defines the features of the baseboard..
Syntax DellBaseBoardFeatureFlags
Access Read-only
Table 163. Baseboard Type
Name
baseBoardType
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.7
76
Description Defines the type of the baseboard.
Syntax DellBaseBoardType
Access Read-only
Table 164. Baseboard Type Name
Name
baseBoardTypeName
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.8
Description Defines the name of the type of baseboard.
Syntax DellString
Access Read-only
Table 165. Baseboard Location Name
Name
baseBoardLocationName
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.9
Description Defines the location name of the baseboard.
Syntax DellString
Access Read-only
Table 166. Baseboard Manufacturer Name
Name
baseBoardManufacturerName
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.10
Description Defines the baseboard manufacturer’s name.
Syntax DellString
Access Read-only
Table 167. Baseboard Product Name
Name
baseBoardProductName
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.11
Description Defines the baseboard product’s name.
Syntax DellString
Access Read-only
Table 168. Baseboard Version Name
Name
baseBoardVersionName
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.12
Description Defines the baseboard version name..
Syntax DellString
Access Read-only
77
Table 169. Baseboard Service Tag Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.13
Description Defines the baseboard service tag name.
Syntax DellString
Access Read-only
Table 170. Baseboard Piece Part ID (PPID) Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.14
Description Defines the baseboard PPID.
Syntax DellString
Access Read-only
Table 171. Baseboard Asset Tag Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.15
Description Defines the baseboard asset tag name.
Syntax DellString
Access Read-only
baseBoardServiceTagName
baseBoardPiecePartIDName
baseBoardAssetTagName
Table 172. Baseboard Express Service Code Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.16
Description Defines the express service code of the baseboard.
Syntax DellString
Access Read-only
baseBoardExpressServiceCodeName

Chassis Information Group Variable Values

This section includes definitions for server administrator-specific variable values used in this section.
Table 173. Log Format
Variable Name : DellLogFormat Data Type: Integer
Possible Data Values Meaning of Data Value
raw(1)
ascii(2)
uniCode(3)
The log is in the format received from the firmware.
The log is in ASCII format.
The log is in Unicode format.
78
Table 174. Chassis Type
Variable Name : DellChassisType Data Type: Integer
Possible Data Values Meaning of Data Value
other(1)
unknown(2)
desktop(3)
lowProfileDeskto
The chassis type is not one of the following:
The chassis type is unknown.
The chassis type is a desktop.
The chassis type is a low-profile desktop.
p(4)
pizzaBox(5)
miniTower(6)
tower(7)
portable(8)
lapTop(9)
noteBook(10)
handHeld(11)
dockingStation(1
The chassis type is a pizza box.
The chassis type is a minitower.
The chassis type is a tower.
The chassis type is a portable.
The chassis type is a laptop.
The chassis type is a notebook.
The chassis type is a handheld.
The chassis type is a docking station.
2)
allInOne(13)
subNoteBook(14)
spaceSaving(15)
lunchBox(16)
mainSystemChassi
The chassis type is an all-in-one.
The chassis type is a subnotebook.
The chassis type is a spacesaver.
The chassis type is a lunch box.
The chassis type is the main system chassis.
s(17)
expansionChassi
The chassis type is an expansion chassis.
s(18)
subChassis(19)
busExpansionChas
The chassis type is a subchassis.
The chassis type is a bus-expansion chassis.
sis(20)
peripheralChassi
The chassis type is a peripheral chassis.
s(21)
raidChassis(22)
rackMountChassi
The chassis type is a disk RAID chassis.
The chassis type is a rack-mounted chassis.
s(23)
sealedCasePC(24)
multiSystemChass
The chassis type is a sealed-case chassis.
The chassis type is a multisystem chassis.
is(25)
Table 175. Connection Status
Variable Name : DellConnectionStatus Data Type: Integer
79
Possible Data Values Meaning of Data Value
unknown(2)
ok(3)
failure(4)
Table 176. Fan Control Capabilities
The status of the chassis connection is unknown.
The status of the chassis connection is OK.
The status of the chassis connection is failure.
Variable Name : DellFanControlCapabilities Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1)
lowSpeedCapable(
The fan’s capabilities are unknown.
The fan can be set to low speed.
2)
highSpeedCapabl
The fan can be set to high speed.
e(4)
lowOrhighSpeedCa
The fan can be set to low or high speed.
pable(6)
Table 177. Front-Panel LED Control Capabilities
Variable Name : DellLEDControlCapabilities Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1)
alertOnErrorCapa ble(2)
alertOnWarningAn dErrorCap able(4)
alertOnWarningOr ErrorCapa ble(6)
The LED control capabilities are unknown.
The LED control can be set to alert on an error condition.
The LED control can be set to alert on an error and a warning condition.
The LED control can be set to alert on an error or a warning condition.
Table 178. Front-Panel LED Control Settings
Variable Name : DellLEDControlSettings Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1)
alertOnError(2)
alertOnWarningAn dError(4)
Table 179. Hard-Drive Fault LED Control Capabilities
The LED control setting is unknown.
The LED control is set to alert on an error condition.
The LED control is set to alert on an error or a warning condition.
Variable Name : DellHDFaultLEDControlCapabilities Data Type: Integer
80
Possible Data Values Meaning of Data Value
none(0)
unknownCapabilit
The hard drive has no fault LED capabilities.
The hard-drive fault LED capabilities are unknown.
ies(1)
enableCapable(2)
The hard-drive fault LED can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).
notReadyCapable(
The hard-drive fault LED can indicate not ready.
4)
resetCapable(8)
Table 180. Hard-Drive Fault LED Control Settings
The hard-drive fault LED can be reset.
Variable Name : DellHDFaultLEDControlSettings Data Type: Integer
Possible Data Values Meaning of Data Value
none(0)
unknown(1)
enabled(2)
The LEDs do not have any fault settings capabilities.
The hard-drive fault LEDs’ state is unknown.
The hard-drive fault LEDs’ state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).
notReady(4)
reset(8)
resetAndEnable(1
0)
The hard-drive fault LEDs’ state is not ready.
The hard-drive fault LEDs have been reset.
The hard-drive fault LEDs have been reset and enabled.
Table 181. Chassis Identification Control Capabilities
Variable Name : DellChassisIdentifyControlCapabilities Data Type: Integer
Possible Data Values Meaning of Data Value
none(0)
The LEDs do not have any chassis identification capabilities.
unknownCapabilit ies(1)
enableCapable(2)
The chassis identification control’s capabilities are unknown.
The chassis identification controls can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).
notReadyCapable(
4)
identifyCapable(
8)
resetAndEnable(1
0)
The chassis identification control’s capabilities are not ready.
The chassis identification control’s LEDs can be made to identify the chassis.
The hard-drive fault LEDs have been reset and enabled.
81
NOTE: Chassis identification capabilities allow system administrators to set front panel light-emitting diodes (LEDs) to blink when the chassis has malfunctioning components. When enabled, the blinking lights help administrators locate the problem chassis.
Table 182. Chassis Identification Control Settings
Variable Name : DellChassisIdentifyControlSettings Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1)
The chassis identification control’s state is unknown..
enabled(2)
The chassis identification control’s state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).
notReady(4)
The chassis identification control’s state is not ready.
identifyChassis(
8)
identifyChassisA ndEnable (10)
The chassis identification control’s LEDs may be returned to (normal) 0, or (identify chassis) 1.
The chassis identification control’s LEDs may be returned to normal (a binary 0 value), or identify chassis and enabled (a binary 1 value).
Table 183. Host Control Capabilities
Variable Name : DellHostControlCapabilities
NOTE: An operator can manually enable these actions using SNMP.
Data Type: Integer
Possible Data Values Meaning of Data Value
manualRebootCapa
The operator can reboot capable host.
ble(1)
manualPowerOFFCa
The operator can power off capable host.
pable(2)
manualPowerCycle
The operator can power-cycle capable host.
Capable(4)
manualAllExceptO perating SystemShutdownCa
The operator can reboot and power off capable host.
pable(7)
manualOperatingS ystemShut downCapable(8)
manualFullyCapab le(15)
The operator can shut down the operating-system– shutdown capable host.
The operator can reboot, power on and off the power-cycle capable host, and shut down the operating-system–shutdown capable host.
manualRebootWith OSShutdow nCapable(16)
The operator can reboot with operating system shutdown.
82
manualRebootWith outOSShut downCapable(32)
manualPowerOffWi thOSShutd ownCapable(64)
manualPowerOffWi thoutOSSh utdownCapable(12
The operator can reboot without operating system shutdown.
The operator can power off with operating system shutdown.
The operator can power off without operating system shutdown.
8)
manualPowerCycle WithOSShu tdownCapable(256
The operator can power cycle with operating system shutdown.
)
manualPowerCycle WithoutOS ShutdownCapable(
The operator can power cycle without operating system shutdown.
512)
Table 184. Host Control Settings
Variable Name : DellHostControlSettings
NOTE: An operator can manually cause these actions using SNMP.
Data Type: Integer
Possible Data Values Meaning of Data Value
manualReboot(1)
manualPowerOFF(2
The operator can reboot the host.
The operator can power off the host.
)
manualPowerCycl
Power cycle the host.
e(4)
manualOperatingS ystemShutdown(8)
manualOperatingS ystemShutdownThe nPowerCycle(12)
The operator can shut down the operating system on the host.
The operator can shut down the operating system on the host then power cycle machine.
Table 185. Watchdog Control Capabilities
Variable Name : DellWatchDogControlCapabilities
NOTE: When the system determines that the operating system is not responding, it automatically performs the selected action without operator intervention.
Data Type: Integer
Possible Data Values Meaning of Data Value
automaticRebootC apable(1)
automaticPowerCy cleCapable(2)
Watchdog controls can be set to reboot capable host.
Watchdog controls can be set to power cycleable capable host.
83
automaticNotific ationCapable(4)
automaticWatchDo gTimerCapable(8)
automaticPowerOf fCapable(16)
automaticAllExce ptNotificationCa p able(27)
automaticFullyCa pable(31)
Table 186. Watchdog Control Settings
Watchdog controls can be set to notify capable host
Watchdog controls can be set to function automatically.
Watchdog controls can be set to automatically power off host.
Watchdog controls can be set to automatically perform all functions except notification capable.
Watchdog controls can be set to automatically perform all functions.
Variable Name : DellWatchControlSettings
NOTE: The watchdog timer is the mechanism used by a chassis to determine if the operating system has stopped responding.
Data Type: Integer
Possible Data Values Meaning of Data Value
automaticRebootE
Automatic reboot is enabled for this host.
nabled(1)
automaticPowerCy
Automatic power cycleable is enabled for this host.
cleEnabled(2)
automaticNotific
Automatic notification is enabled for this host.
ationEnabled(4)
automaticPowerOf
Automatic power off is enabled for this host.
fEnabled(8)
Table 187. Watchdog Timer Capabilities
Variable Name : DellWatchDogTimerCapabilities Data Type: Integer
Possible Data Values Meaning of Data Value
type1Capable(1)
Watchdog timer can time in intervals from 20–480 seconds.
type2Capable(2)
Watchdog timer can time in 30-, 60-, 120-, and 480­second intervals.
type3Capable(4)
Table 188. Power Button Control Capabilities
Watchdog timer can time in 60-second intervals.
Variable Name : DellPowerButtonControlCapabilities Data Type: Integer
Possible Data Values Meaning of Data Value
none(0)
unknownCapabilit
The power button has no capabilities.
The power button capabilities are unknown.
ies(1)
84
enableCapable(2)
The power button can be enabled (online) or disabled (offline).
Table 189. Power Button Control Settings
Variable Name : DellPowerButtonControlSettings Data Type: Integer
Possible Data Values Meaning of Data Value
none(0)
unknown(1)
enabled(2)
disabled(4)
Table 190. NMI Button Control Capabilities
The power button has no settings capabilities.
The power button settings are unknown.
The power button state is enabled.
The power button state is disabled.
Variable Name : DellNMIButtonControlCapabilities Data Type: Integer
Possible Data Values Meaning of Data Value
none(0)
unknownCapabilit
The NMI button has no capabilities.
The NMI button capabilities are unknown.
ies(1)
enableCapable(2)
The NMI button can be enabled (online) or disabled (offline).
Table 191. System Properties
Variable Name : DellSystemProperties
NOTE: These values are bit masks, so combination values are possible.
Data Type: Integer
Possible Data Values Meaning of Data Value
none(0)
energySmart(1)
Table 192. NMI Button Control Settings
No properties.
The system is an Energy Smart System.
Variable Name : DellNMIButtonControlSettings Data Type: Integer
Possible Data Values Meaning of Data Value
none(0)
unknown(1)
enabled(2)
disabled(4)
The NMI button has no settings capabilities.
The NMI button settings are unknown.
The NMI button state is enabled.
The NMI button state is disabled.
85
Table 193. Baseboard Type
Variable Name : DellBaseBoardType Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1)
other(2)
The baseboard type is unknown.
The baseboard type is not one of the following types.
serverBlade(3)
connectivitySwit
The baseboard type is a server blade.
The baseboard type is a connectivity switch.
ch(4)
systemManagement Module(5)
processorModule(
The baseboard type is a system management module.
The baseboard type is a processor module.
6)
ioModule(7)
memoryModule(8)
daughterBoard(9)
motherboard(10)
processorMemoryM odule(11)
processorIOModul
The baseboard type is an I/O module.
The baseboard type is a memory module
The baseboard type is a daughter board.
The baseboard type is a mother board.
The baseboard type is a processor or memory module
The baseboard type is a processor or I/O module
e(12)
interconnectBoar
The baseboard type is an interconnect board.
d(13)
Table 194. Chassis System Class
Variable Name : DellChassisSystemClass Data Type: Integer
Possible Data Values Meaning of Data Value
other(1)
The chassis system class is not one of the following:
unknown(2)
workstationClas
The chassis system class is unknown.
The chassis system class is a workstation.
s(3)
serverClass(4)
desktopClass(5)
portableClass(6)
netPCClass(7)
storageClass(8)
Table 195. Firmware Type
The chassis system class is a server.
The chassis system class is a desktop.
The chassis system class is a portable.
The chassis system class is a Net PC.
The chassis system class is storage.
Variable Name : DellFirmwareType
86
Data Type: Integer
Possible Data Values Meaning of Data Value
other(1)
unknown(2)
systemBIOS(3)
embeddedSystemMa nagementContro ller(4)
powerSupplyParal lelingBoard(5)
systemBackPlane(
The firmware type is other than following values.
The firmware type is unknown.
The firmware type is System BIOS
The firmware type is Embedded System Management Controller.
The firmware type is Power Supply Paralleling Board.
The firmware type is System (Primary) Backplane.
6)
powerVault2XXSKe
The firmware type is Dell PowerVault 2XXS Kernel.
rnel(7)
powerVault2XXSAp
The firmware type is PowerVault 2XXS Application.
plication(8)
frontPanel(9)
baseboardManagem entController (10)
hotPlugPCI(11)
The firmware type is Front Panel Controller.
The firmware type is Baseboard Management Controller.
The firmware type is Hot Plug Peripheral Component Interconnect (PCI) Controller.
sensorData(12)
peripheralBay(13
The firmware type is Sensor Data Records.
The firmware type is Peripheral Bay Backplane.
)
secondaryBackPla ne(14)
secondaryBackPla neESM3And4(15)
rac(16)
iDRAC(17)
The firmware type is Secondary Backplane for ESM 2 systems.
The firmware type is Secondary Backplane for ESM 3 and 4 systems.
The firmware type is Remote Access Controller.
The firmware type is Integrated Dell Remote Access Controller.
unifiedServerCon
The firmware type is Unified Server Configurator.
figurator(19)
lifecycleControl
The firmware type is Lifecycle Controller.
ler(20)
Table 196. Baseboard Feature Flags
Variable Name : DellBaseBoardFeatureFlags Data Type: Integer
Possible Data Values Meaning of Data Value
NOTE: These values are bit fields, so combination values are possible.
no features(0)
This baseboard has no feature flags.
87
boardIsHostingBo ard(1)
boardRequiresDau ghterBoard (2)
boardIsRemovabl e(4)
boardIsReplaceab le(8)
boardIsHotSwappa ble(16)
This baseboard is a hosting board.
This baseboard requires at least one daughter board or auxiliary card.
This baseboard is removable.
This baseboard is replaceable.
This baseboard is hot swappable.
88
7

Operating System Group

The Operating System Group provides status and identifying information about a system’s operating system. Identifying information includes the name, version, and service pack of the installed operating system.
The following objects describe the fields for Operating System Group.

Operating System Memory Table

Table 197. Operating System Memory Table
Name
Object ID 1.3.6.1.4.1.674.10892.1.400.20
Description Defines the Operating System Memory Table.
Syntax SEQUENCE OF OperatingSystemMemoryTableEntry
Access Not accessible
Table 198. Operating System Memory Table Entry
Name
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1
Description Defines the Operating System Memory Table entry.
Syntax OperatingSystemMemoryTableEntry
Access Not accessible
Index
Table 199. Operating System Memory Chassis Index
Name
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only
operatingSystemMemoryTable
operatingSystemTableEntry
operatingSystemMemorychassisIndex
operatingSystemMemorychassisIndex
Table 200. Operating System Memory State Capabilities
Name
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.2
Description Defines the capabilities of the operating system memory.
Syntax DellStateCapabilities
operatingSystemMemoryStateCapabilities
89
Access Read-only
Table 201. Operating System Memory State Settings
Name
operatingSystemMemoryStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.3
Description Defines the state and allows the setting of the operating system memory.
Syntax DellStateSettings
Access Read-write
Table 202. Operating System Memory Status
Name
operatingSystemMemoryStatus
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.4
Description Defines the status of the operating system memory.
Syntax DellStatus
Access Read-only
Table 203. Operating System Memory Total Physical Size
Name
operatingSystemMemoryTotalPhysicalSize
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.5
Description Defines the total physical memory size in kilobytes.
Syntax DellUnsigned32BitRange
Access Read-only
Table 204. Operating System Memory Available Physical Size
Name
operatingSystemMemoryAvailablePhysicalSize
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.6
Description Defines the available physical memory size in kilobytes.
Syntax DellUnsigned32BitRange
Access Read-only
Table 205. Operating System Memory Total Page File Size
Name
operatingSystemMemoryTotalPageFileSize
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.7
Description Defines the total page file memory size in kilobytes.
Syntax DellUnsigned32BitRange
Access Read-only
90
Table 206. Operating System Memory Available Page File Size
Name
operatingSystemMemoryAvailablePageFileSize
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.8
Description Defines the available page file memory size in kilobytes.
Syntax DellUnsigned32BitRange
Access Read-only
Table 207. Operating System Memory Total Virtual Size
Name
operatingSystemMemoryTotalVirtualSize
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.9
Description Defines the total virtual memory size in kilobytes.
Syntax DellUnsigned32BitRange
Access Read-only
Table 208. Operating System Memory Available Virtual Size
Name
operatingSystemMemoryAvailableVirtualSize
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.10
Description Defines the available virtual memory size in kilobytes.
Syntax DellUnsigned32BitRange
Access Read-only
91
92

System Resource Group

The Management Information Base (MIB) variables presented in this section enable you to track various attributes of your system resources. This section includes System Resource Group Tables that track variables such as the owner, ports, system memory, interrupts, and direct memory access.

System Resource Group Tables

The following MIB tables define objects for the System Resource Group:
System Resource Map Table
System Resource Owner Table
System Resource Input/Output (I/O) Port Table
System Resource Memory Table
System Resource Interrupt Table
System Resource Direct Memory Access (DMA) Table

System Resource Map Table

Table 209. System Resource Map Table
8
Name
Object ID 1.3.6.1.4.1.674.10892.1.500.10
Description Defines the System Resource Map Table.
Syntax SEQUENCE OF SystemResourceMapTableEntry
Access Not accessible
Table 210. System Resource Map Table Entry
Name
Object ID 1.3.6.1.4.1.674.10892.1.500.10.1
Description Defines the System Resource Map Table entry.
Syntax SystemResourceMapTableEntry
Access Not accessible
Index
systemResourceMapTable
systemResourceMapTableEntry
systemResourceMapchassisIndex
,
systemResourceMapIndex
93
Table 211. System Resource Map Chassis Index
Name
systemResourceMapChassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only
Table 212. System Resource Map Index
Name
systemResourceMapIndex
Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.2
Description Defines the index of system resource maps in this chassis.
Syntax DellObjectRange
Access Read-only
Table 213. System Resource Map State Capabilities
Name
systemResourceMapStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.3
Description Defines the capabilities of this system map.
Syntax DellStateCapabilities
Access Read-only
Table 214. System Resource Map State Settings
Name
systemResourceMapStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.4
Description Defines the state and allows the setting of this system map.
Syntax DellStateSettings
Access Read-write
Table 215. System Resource Map Status
Name
systemResourceMapStatus
Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.5
Description Defines the status of this system map.
Syntax DellStatus
Access Read-only
Table 216. System Resource Map Type
Name
systemResourceMapType
Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.6
94
Description Defines the type of this system map.
Syntax DellSystemResourceMapType (System Resource Map Type)
Access Read-only

System Resource Owner Table

Table 217. System Resource Owner Table
Name
Object ID 1.3.6.1.4.1.674.10892.1.500.20
Description Defines the System Resource Owner Table.
Syntax SEQUENCE OF SystemResourceOwnerTableEntry
Access Not accessible
Table 218. System Resource Owner Table Entry
Name
Object ID 1.3.6.1.4.1.674.10892.1.500.20.1
Description Defines the System Resource Owner Table entry. Variables in this group reference
Syntax SystemResourceOwnerTableEntry
Access Not accessible
Index
Table 219. System Resource Owner Chassis Index
Name
Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only
systemResourceOwnerTable
systemResourceOwnerTable
the System Resource Map index.
systemResourceOwnerchassisIndex
,
systemResourceOwnerIndex
systemResourceOwnerchassisIndex
Table 220. System Resource Owner Index
Name
Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.2
Description Defines the index of system resource owners for this chassis.
Syntax DellObjectRange
Access Read-only
systemResourceOwnerIndex
95
Table 221. System Resource Owner State Capabilities
Name
systemResourceOwnerStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.3
Description Defines the capabilities of this system resource owner.
Syntax DellStateCapabilities
Access Read-only
Table 222. System Resource Owner State Settings
Name
systemResourceOwnerStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.4
Description Defines the state settings of this system resource owner.
Syntax DellStateSettings
Access Read-write
Table 223. System Resource Owner Status
Name
systemResourceOwnerStatus
Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.5
Description Defines the status of this system resource owner.
Syntax DellStatus
Access Read-write
Table 224. System Resource Owner Interface Type
Name
systemResourceOwnerInterfaceType
Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.6
Description Defines the interface type for this system resource owner.
Syntax DellResourceOwnerInterfaceType (Resource Owner Interface Type)
Access Read-only
Table 225. System Resource Map Index Reference
Name
systemResourceMapIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.7
Description Defines the index to the associated system resource map in this chassis.
Syntax DellObjectRange
Access Read-only
Table 226. System Resource Owner Description Name
Name
systemResourceOwnerDescriptionName
Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.8
96
Description Defines the description name of the system resource owner.
Syntax DellString
Access Read-only
Table 227. System Resource Owner Interface Instance
Name
Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.9
Description Defines the associated system resource owner interface instance in this chassis.
Syntax DellObjectRange
Access Read-only
systemResourceOwnerInterfaceInstance

System Resource Input/Output (I/O) Port Table

Table 228. System Resource Input/Output (I/O) Port Table
Name
Object ID 1.3.6.1.4.1.674.10892.1.500.30
Description Defines the System Resource I/O Port Table.
Syntax SEQUENCE OF SystemResourceIOPortTableEntry
Access Not accessible
Table 229. System Resource I/O Port Table Entry
Name
Object ID 1.3.6.1.4.1.674.10892.1.500.30.1
Description Defines the System Resource I/O Port Table entry.
Syntax SystemResourceIOPortTableEntry
Access Not accessible
Index
systemResourceIOPortTable
systemResourceIOPortTableEntry
systemResourceIOPortchassisIndex
,
systemResourceIOPortIndex
Table 230. System Resource I/O Port Chassis Index
Name
Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only
systemResourceIOPortchassisIndex
97
Table 231. System Resource I/O Port Index
Name
systemResourceIOPortIndex
Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.2
Description Defines the index (one-based) of the system resource I/O ports in this chassis.
Syntax DellObjectRange
Access Read-only
Table 232. System Resource I/O Port State Capabilities
Name
systemResourceIOPortStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.3
Description Defines the capabilities of the system resource I/O port.
Syntax DellStateCapabilities
Access Read-only
Table 233. System Resource I/O Port State Settings
Name
systemResourceIOPortStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.4
Description Defines the state and allows the setting of the system resource I/O port.
Syntax DellStateSettings
Access Read-write
Table 234. System Resource I/O Port Status
Name
systemResourceIOPortStatus
Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.5
Description Defines the status of the system resource I/O port.
Syntax DellStateSettings
Access Read-only
Table 235. System Resource I/O Port Owner Index Reference
Name
systemResourceIOPortOwnerIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.6
Description Defines the index to the associated system resource owner in this chassis.
Syntax DellObjectRange
Access Read-only
Table 236. System Resource I/O Port Share Disposition
Name
systemResourceIOPortShareDisposition
Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.7
98
Description Defines the share disposition of the system resource I/O port.
Syntax DellResourceShareDisposition (Resource Share Disposition)
Access Read-only
Table 237. System Resource I/O Port Starting Address
Name
Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.8
Description Defines the 64 bits of the starting address of the system resource I/O port.
Syntax DellUnsigned64BitRange
Access Read-only
Table 238. System Resource I/O Port Ending Address
Name
Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.9
Description Defines the 64 bits of the ending address of the system resource I/O port.
Syntax DellUnsigned64BitRange
Access Read-only
systemResourceIOPortStartingAddress
systemResourceIOPortEndingAddress

System Resource Memory Table

Table 239. System Resource Memory Table
Name
Object 1.3.6.1.4.1.674.10892.1.500.40
Description Defines the System Resource Memory Table.
Syntax SEQUENCE OF SystemResourceMemoryTableEntry
Access Not accessible
systemResourceMemoryTable
Table 240. System Resource Memory Table Entry
Name
Object ID 1.3.6.1.4.1.674.10892.1.500.40.1
Description Defines the System Resource Memory Table entry.
Syntax SystemResourceMemoryTableEntry
Access Not accessible
Index
systemResourceMemoryTableEntry
systemResourceMemorychassisIndex
,
systemResourceMemoryIndex
99
Table 241. System Resource Memory Chassis Index
Name
systemResourceMemorychassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only
Table 242. System Resource Memory Index
Name
systemResourceMemoryIndex
Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.2
Description Defines the index of system resource memory in this chassis.
Syntax DellObjectRange
Access Read-only
Table 243. System Resource Memory State Capabilities
Name
systemResourceMemoryStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.3
Description Defines the capabilities of this system resource memory.
Syntax DellObjectRange
Access Read-only
Table 244. System Resource Memory State Settings
Name
systemResourceMemoryStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.4
Description Defines the state of this system resource memory.
Syntax DellObjectRange
Access Read-write
Table 245. System Resource Memory Status
Name
systemResourceMemoryStatus
Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.5
Description Defines the status of this system resource memory.
Syntax DellStatus
Access Read-only
Name
systemResourceMemoryOwnerIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.6
Description Defines the index to the associated system resource owner in this chassis.
100
Loading...