Dell OpenManage Server Administrator Version 7.2 SNMP Reference Guide

Dell OpenManage SNMP Reference Guide Version 7.2
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use of your computer.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
© 2012 Dell Inc.
Trademarks used in this text: Dell™, the Dell logo, Dell Boomi™, Dell Precision™ , OptiPlex™, Latitude™, PowerEdge™, PowerVault™, PowerConnect™, OpenManage™, EqualLogic™, Compellent™, KACE™, FlexAddress™, Force10™ and Vostro™ are trademarks of Dell Inc. Intel®, Pentium®, Xeon®, Core® and Celeron® are registered trademarks of Intel Corporation in the U.S. and other countries. AMD is a registered trademark and AMD Opteron™, AMD Phenom™ and AMD Sempron™ are trademarks of Advanced Micro Devices, Inc. Microsoft®, Windows®, Windows Server®, Internet Explorer®, MS-DOS®, Windows Vista® and Active Directory® are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Red Hat® and Red Hat Enterprise Linux® are registered trademarks of Red Hat, Inc. in the United States and/or other countries. Novell® and SUSE® are registered trademarks of Novell Inc. in the United States and other countries. Oracle® is a registered trademark of Oracle Corporation and/or its affiliates. Citrix®, Xen®, XenServer® and XenMotion® are either registered trademarks or trademarks of Citrix Systems, Inc. in the United States and/or other countries. VMware trademarks of VMware, Inc. in the United States or other countries. Corporation.
2012 - 12
®
,
Virtual SMP
®
®
,
vMotion
®
is a registered trademark of International Business Machines
IBM
,
vCenter
®
and
vSphere
®
are registered trademarks or
®
®
Rev. A00
Contents
Notes, Cautions, and Warnings...................................................................................................2
1 Introduction................................................................................................................................11
Supported SNMP Versions.....................................................................................................................................11
Introduction to the SNMP Reference Guide...........................................................................................................11
Server Administrator Instrumentation MIB......................................................................................................11
Server Administrator Remote Access MIB......................................................................................................13
Server Administrator Baseboard Management Controller, ASF MIB..............................................................13
Server Administrator Field Replaceable Unit MIB...........................................................................................13
Server Administrator Storage Management MIB............................................................................................14
Server Administrator Change Management MIB............................................................................................14
Dell Remote Access Controller Out-of-Band MIB...........................................................................................15
How This Guide Defines Technical Terms.......................................................................................................15
Basic Terminology............................................................................................................................................15
Frequently Used Terms in Variable Names......................................................................................................15
Tables...............................................................................................................................................................16
Section Organization........................................................................................................................................17
Other Documents You May Need.....................................................................................................................18
Introduction to the Server Administrator SNMP Subagent....................................................................................18
Management Information Base Object Identifiers..........................................................................................19
SNMP Security.................................................................................................................................................20
Management Actions.......................................................................................................................................20
SNMP Traps.....................................................................................................................................................21
2 Dell OpenManage SNMP Version 7.2....................................................................................23
What’s New in This Release...................................................................................................................................23
3 Instrumentation MIB Version Group......................................................................................27
Management Information Base Major Version Number........................................................................................27
Management Information Base Minor Version Number........................................................................................27
Management Information Base Maintenance Version Number............................................................................27
4 Systems Management Software Group................................................................................29
Systems Management Software............................................................................................................................29
Systems Management Software Variable Values..................................................................................................32
5 System State Group..................................................................................................................33
System State Group Table......................................................................................................................................33
System State Table..........................................................................................................................................33
List 1.................................................................................................................................................................33
List 2.................................................................................................................................................................34
System State Table..........................................................................................................................................34
6 Chassis Information Group......................................................................................................49
Chassis Information Group Tables..........................................................................................................................49
Chassis Information Table................................................................................................................................49
UUID Table.......................................................................................................................................................60
POST Log Table................................................................................................................................................61
Event Log Table................................................................................................................................................63
System BIOS Table...........................................................................................................................................65
Firmware Table.................................................................................................................................................70
Intrusion Table.................................................................................................................................................73
Baseboard Table..............................................................................................................................................75
Chassis Information Group Variable Values...........................................................................................................78
7 Operating System Group..........................................................................................................89
Operating System Memory Table...........................................................................................................................89
8 System Resource Group..........................................................................................................93
System Resource Group Tables.............................................................................................................................93
System Resource Map Table...........................................................................................................................93
System Resource Owner Table........................................................................................................................95
System Resource Input/Output (I/O) Port Table...............................................................................................97
System Resource Memory Table.....................................................................................................................99
System Resource Interrupt Table..................................................................................................................101
System Resource Direct Memory Access (DMA) Table................................................................................104
System Resource Group Variable Values.............................................................................................................106
9 Power Group............................................................................................................................109
Power Group Tables.............................................................................................................................................109
Power Unit Table............................................................................................................................................109
Power Supply Table.......................................................................................................................................111
Voltage Probe Table.......................................................................................................................................114
Amerage Probe Table....................................................................................................................................118
AC Power Switch Table.................................................................................................................................122
AC Power Cord Table.....................................................................................................................................124
Battery Table..................................................................................................................................................126
Power Usage Table........................................................................................................................................127
Power Profile Table........................................................................................................................................132
Power Group Variable Values...............................................................................................................................134
10 Thermal Group.......................................................................................................................143
Thermal Group Tables..........................................................................................................................................143
Cooling Unit Table..........................................................................................................................................143
Cooling Device Table......................................................................................................................................145
Temperature Probe Table..............................................................................................................................149
Thermal Group Variable Values............................................................................................................................153
11 User Security Group.............................................................................................................155
User Security Group Table...................................................................................................................................155
12 Remote Flash BIOS Group...................................................................................................157
Remote Flash BIOS Group Table..........................................................................................................................157
Remote Flash BIOS Table...............................................................................................................................157
Remote Flash BIOS Variable Values.....................................................................................................................159
13 Port Group..............................................................................................................................161
Port Group Tables.................................................................................................................................................161
Pointing Port Table.........................................................................................................................................161
Keyboard Port Table.......................................................................................................................................163
Processor Port Table......................................................................................................................................166
Memory Device Port Table.............................................................................................................................168
Monitor Port Table.........................................................................................................................................171
Small Computer System Interface (SCSI) Port Table.....................................................................................173
Parallel Port Table..........................................................................................................................................175
Serial Port Table.............................................................................................................................................179
Universal Serial Bus (USB) Port Table...........................................................................................................182
Port Group Variable Values..................................................................................................................................184
14 Device Group.........................................................................................................................189
Device Tables.......................................................................................................................................................189
Pointing Device Table....................................................................................................................................189
Keyboard Device Table..................................................................................................................................191
Processor Device Table.................................................................................................................................193
Processor Device Status Table......................................................................................................................199
Cache Device Table.......................................................................................................................................201
Memory Device Table....................................................................................................................................205
Memory Device Mapped Address Table.......................................................................................................211
Generic Device Table.....................................................................................................................................214
PCI Device Table............................................................................................................................................216
PCI Device Configuration Space Table..........................................................................................................218
Network Device Table....................................................................................................................................221
Managed System Services Device Table......................................................................................................227
SD Card Unit Table.........................................................................................................................................228
SD Card Device Table....................................................................................................................................230
Device Group Variable Values..............................................................................................................................233
15 Slot Group...............................................................................................................................257
System Slot Group Table......................................................................................................................................257
System Slot Variable Values.................................................................................................................................260
16 Memory Group.......................................................................................................................267
Physical Memory Tables......................................................................................................................................267
Physical Memory Array Table........................................................................................................................267
Physical Memory Array Mapped Table.........................................................................................................271
Physical Memory Configuration Table...........................................................................................................273
Physical Memory Logging Table....................................................................................................................276
Redundant Memory Unit Table......................................................................................................................277
Physical Memory Card Table.........................................................................................................................279
Memory Group Variable Values............................................................................................................................282
17 BIOS Setup Control Group...................................................................................................287
BIOS Setup Control Group Tables........................................................................................................................287
BIOS Setup Control Group Tables..................................................................................................................287
SCSI Control Table.........................................................................................................................................296
Parallel Port Control Table.............................................................................................................................297
Serial Port Control Table................................................................................................................................299
USB Control Table..........................................................................................................................................301
IDE Control Table............................................................................................................................................302
Diskette Control Table....................................................................................................................................304
Network Interface Control Table....................................................................................................................306
BIOS Setting Table.........................................................................................................................................307
BIOS Group Variable Values.................................................................................................................................310
18 Local Response Agent Group..............................................................................................319
LRA Group Tables.................................................................................................................................................319
LRA Global Settings........................................................................................................................................319
LRA Action Table............................................................................................................................................321
Local Response Agent Variable Values................................................................................................................323
19 Cost of Ownership Group.....................................................................................................325
Cost of Ownership Group Tables..........................................................................................................................325
Cost of Ownership Table................................................................................................................................325
COO Service Contract Table...........................................................................................................................333
COO Cost Event Log Table..............................................................................................................................335
COO Warranty Table......................................................................................................................................337
COO Lease Information Table........................................................................................................................339
COO Schedule Number Table........................................................................................................................341
COO Options Table.........................................................................................................................................343
COO Maintenance Table................................................................................................................................344
COO Repair Table...........................................................................................................................................346
COO Support Information Table.....................................................................................................................348
COO Trouble Ticket Table...............................................................................................................................350
Cost of Ownership Variable Values......................................................................................................................351
20 Remote Access Group..........................................................................................................353
DRAC 4 and DRAC 5..............................................................................................................................................353
Remote Access Table....................................................................................................................................353
DRAC III.................................................................................................................................................................357
Remote Access Table....................................................................................................................................358
Remote User Administration Table................................................................................................................365
Remote SNMP Trap Table..............................................................................................................................371
Remote Dial-Up Table....................................................................................................................................374
Remote User Dial-In Configuration Table......................................................................................................378
Remote Dial-Out Table...................................................................................................................................380
Remote Access Variable Values..........................................................................................................................382
21 Cluster Group ........................................................................................................................393
Cluster Group........................................................................................................................................................393
Cluster Table..................................................................................................................................................393
Cluster Group Variable Values..............................................................................................................................395
22 Baseboard Management Controller Group......................................................................397
Baseboard Management Controller Group Tables...............................................................................................397
Baseboard Management Controller Table.....................................................................................................397
Baseboard Management Controller Serial Interface....................................................................................400
Baseboard Management Controller LAN Interface Table.............................................................................403
Baseboard Management Controller Group Variable Values................................................................................406
23 Field Replaceable Unit Group..............................................................................................409
Field Replaceable Unit Group Tables...................................................................................................................409
Field Replaceable Unit Group Variable Values.....................................................................................................411
24 Storage Management Group...............................................................................................413
Storage Management Group................................................................................................................................413
Storage Management Information Group............................................................................................................414
Global Data Group.................................................................................................................................................415
Physical Devices Group........................................................................................................................................419
Controller Table..............................................................................................................................................419
Channel Table.................................................................................................................................................435
Enclosure Table..............................................................................................................................................439
Array Disk Table.............................................................................................................................................447
Array Disk Enclosure Connection Table........................................................................................................459
Array Disk Channel Connection Table...........................................................................................................461
Fan Table........................................................................................................................................................463
Fan Connection Table.....................................................................................................................................467
Power Supply Table.......................................................................................................................................469
Power Supply Connection Table....................................................................................................................472
Temperature Probe Table..............................................................................................................................474
Temperature Probe Connection Table...........................................................................................................478
Enclosure Management Module Table..........................................................................................................479
Enclosure Management Module Connection Table......................................................................................483
Battery Table..................................................................................................................................................485
Battery Connection Table...............................................................................................................................486
Tape Drive Table............................................................................................................................................488
Logical Devices Group..........................................................................................................................................490
Array Disk Logical Connection Table.............................................................................................................498
Storage Management Event Group......................................................................................................................500
25 Change Management Group...............................................................................................503
Inventory Group....................................................................................................................................................503
Device Group........................................................................................................................................................503
Device Group Table........................................................................................................................................503
Application Group.................................................................................................................................................505
Application Group Table.................................................................................................................................505
Operating System Group.......................................................................................................................................507
Inventory Collector Product Information..............................................................................................................507
26 Dell Remote Access Controller Out-of-Band Group........................................................509
Product Information..............................................................................................................................................509
Chassis Status......................................................................................................................................................512
DRsCMCChangeTime.....................................................................................................................................518
Chassis Power......................................................................................................................................................518
CMC Power Information.......................................................................................................................................519
CMC PSU Information...........................................................................................................................................521
Chassis Alert.........................................................................................................................................................523
Legacy Alerting.....................................................................................................................................................524
27 SNMP Traps...........................................................................................................................527
Trap Variables.......................................................................................................................................................527
Understanding The Trap Description...................................................................................................................529
Understanding Trap Severity................................................................................................................................531
RAC Traps.............................................................................................................................................................532
BMC Traps............................................................................................................................................................534
28 Storage Management Alert Reference.............................................................................539
Alert Monitoring and Logging...............................................................................................................................539
Viewing Alerts.......................................................................................................................................................539
Alert Severity Levels.............................................................................................................................................539
SNMP Support for Storage Management Alerts..................................................................................................540
SNMP Trap Forwarding.................................................................................................................................540
SNMP Trap Definitions...................................................................................................................................540
Trap Variables................................................................................................................................................541
Viewing SNMP Traps............................................................................................................................................543
Alert Descriptions and Corrective Actions...........................................................................................................543
29 iDRAC7 MIB............................................................................................................................545
Supported Systems...............................................................................................................................................545
Blade Servers.................................................................................................................................................545
Rack and Tower Servers................................................................................................................................545
iDRAC7 Supported SNMP Versions......................................................................................................................545
iDRAC7 SNMP Data Security Features.................................................................................................................546
iDRAC7 Out-of-Band Group..................................................................................................................................546
RAC Information Group..................................................................................................................................546
Chassis Information Group.............................................................................................................................548
System Information Group.............................................................................................................................548
Status Group...................................................................................................................................................551
Systems Details Group...................................................................................................................................552
Storage Details Group....................................................................................................................................552
iDRAC7 Traps........................................................................................................................................................553
Trap Variables................................................................................................................................................553
System Trap Group.........................................................................................................................................555
Storage Trap Group........................................................................................................................................563
Updates Trap Group.......................................................................................................................................565
Audit Trap Group............................................................................................................................................565
Configuration Trap Group...............................................................................................................................566
30 Standard Data Type Definitions..........................................................................................567
Common Data Types.............................................................................................................................................567
Variables with Data Types of State Capabilities and State Capabilities Unique..................................................567
Dell Status Data Types..........................................................................................................................................568
Dell Date...............................................................................................................................................................569
Full Dates........................................................................................................................................................570
31 SNMP Sample Output...........................................................................................................571
1

Introduction

This reference guide provides information about the Simple Network Management Protocol (SNMP) Management Information Base (MIB) which is applicable for Dell OpenManage Version 7.
NOTE: This guide contains information that may also be applicable to earlier OpenManage supported platforms.
This introduction is divided into two sections. The first section, Introduction to the SNMP Reference Guide, explains the SNMP Reference Guide design. All essential Simple Network Management Protocol (SNMP) terms are defined in this section. Some of the vocabulary may seem complex and unfamiliar to system administrators who are using SNMP for the first time. SNMP experts can skim this section, and beginners can read the section more carefully.
The second section, Introduction to the Server Administrator SNMP Subagent, is a more technical introduction to the management information base (MIB) that underlies Server Administrator services.

Supported SNMP Versions

Operating System Supported OMSA SNMP version
Windows SNMP v1
Linux SNMP v1

Introduction to the SNMP Reference Guide

This reference guide provides a formatted version of the following Management Information Base that are released with the current version of Dell OpenManage.
Sections in this guide follow MIB groups and provide explanations and definitions for the terms used to define MIB objects. Content in this reference guide is organized as documented in the following subsections.

Server Administrator Instrumentation MIB

The Server Administrator Instrumentation MIB ( filename 10892.mib ) provides instrumentation data that allows you to monitor the health of a system with SNMP management applications. It provides:
Information about the status of temperatures, power supplies, voltages, currents, fans, and memory at key points in the system
Rapid access to detailed fault and performance information gathered by industry standard systems management agents
Version information for Basic Input/Output System (BIOS), firmware, and operating system
A detailed account of every cost of ownership (COO) detail about your system
In addition, traps are sent to report a change in status of the health of critical components.
The Server Administrator Instrumentation MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. The below table describes each Server Administrator Instrumentation MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Instrumentation MIB groups are
11
identified by the SNMP OID 1.3.6.1.4.1.674.10892.1.< number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group.
Table 1. Server Administrator Instrumentation MIB Sections in This Guide
Section Topics MIB Group Numbers
2 Instrumentation MIB Version Group — defines version numbers of
the Instrumentation MIB
3 Systems Management Software Group — defines information
about the systems management software and the supported systems management standards
4 System State Group — defines status, state, and redundancy for a
system and its components
5 Chassis Information Group — defines chassis types, events, and
indicators
6 Operating System Group — defines variables for name, version,
service pack, and other information about a system’s operating system
7 System Resource Group — defines variables for input/output
ports, memory, interrupts, and direct memory access
8 Power Group — defines variables for power units, power supplies,
and their current and voltage probes
9 Thermal Group — defines variables for temperature probes and
cooling devices
10 User Security Group — defines variables for creating and
modifying user accounts
11 Remote Flash BIOS Group — defines variables for updating the
system’s BIOS remotely
12 Port Group — defines variables for major port types such as
keyboard, monitor, small computer system interface (SCSI), Universal Serial Bus (USB), and parallel and serial ports
13 Device Group — defines variables for pointing, keyboard,
processor, cache, memory, and personal computer interface devices
14 Slot Group — defines variables for the system’s slots 1200
15 Memory Group — defines variables for the system’s physical
memory
16 BIOS Setup Control Group — defines variables for BIOS functions
such as boot sequence, speakers, Wake on the local area network (LAN), diskettes, ports, and network interface controllers (NIC)
17 Local Response Agent Group — defines variables for global
settings and actions. These variables allow users to predetermine how the system responds to a particular type of event
18 Cost of Ownership Group — defines variables for tracking data on
the system’s service contract, lease, repair records, trouble tickets, and so on
MIB group number
>, where <
MIB group number
1
100
200
300
400
500
600
700
800
900
1000
1100
1300
1400
1500
1600
> is the MIB group
12
Section Topics MIB Group Numbers
20 Cluster Group — defines variables for systems that operate as a
cluster
21 Baseboard Management Controller Group — provides information
about the Baseboard Management Controller (BMC) that may be present in your system. In addition to providing general information about the BMC, this group provides information about the serial and local area network (LAN) interfaces of the BMC
26 Traps — defines the types of alerts that can be sent to report the
status of critical components
1800
1900
5000

Server Administrator Remote Access MIB

The Server Administrator Remote Access MIB ( filename dcs3rmt.mib ) provides in-band information about remote access hardware that may be present in your system.
The Server Administrator Remote Access MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. Table below describes each Server Administrator Remote Access MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Remote Access MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1.< assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group.
Table 2. Server Administrator Remote Access MIB Sections in This Guide
Section Topic MIB Group Numbers
19 Remote Access Group — provides information about remote
access hardware that may be present in your system and defines variables for administrative users, SNMP trap destinations, modem configuration for dial-up networking, dial-in configuration, and dial-out destinations
MIB group number
> where <
MIB group number
> is the MIB group number
1700

Server Administrator Baseboard Management Controller, ASF MIB

The Server Administrator BMC MIB (filename DcAsfSrv.mib) provides information about the traps sent by BMC. The Server Administrator BMC MIB structures its MIB objects that provide related information. The BMC MIB groups are identified by the SNMP OID 1.3.6.1.4.1.3183.1.1.< hence the enterprise ID is wired for management (3183).
MIB group number
>. The BMC MIB adheres to ASF 2.0 standard and

Server Administrator Field Replaceable Unit MIB

The Server Administrator Field Replaceable Unit MIB (filename dcs3fru.mib) provides information about field replaceable unit (FRU) hardware that may be present in your system.
The Server Administrator Field Replaceable Unit MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. The following table describes each Server Administrator Field Replaceable Unit MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Field Replaceable Unit MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1.< the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group.
MIB group number
> where <
MIB group number
> is
13
Table 3. Server Administrator Field Replaceable Unit MIB Sections in This Guide
Section Topic MIB Group Numbers
22 Field Replaceable Unit Group — provides information about field
replaceable units that may be present in your system
2000

Server Administrator Storage Management MIB

The Server Administrator Storage Management MIB (filename dcstorag.mib) provides storage management data that allows you to monitor the health of storage resources with SNMP management applications.
The following table describes each Server Administrator Storage Management MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Storage Management MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.<MIB group number> where <MIB group number> is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group.
Table 4. Server Administrator Storage Management MIB Sections in This Guide
Section Topics MIB Group Numbers
23 Storage Management Group — consists of definitions for the
following MIB groups:
Storage Management Group
Storage Management Information Group
Global Data Group
Physical Devices Group
Logical Devices Group
Storage Management Event Group
Software Group
10893 NA 20 NA NA 130 140 NA 1
27 Storage Management Alert Reference — lets you monitor the
health of storage resources such as controllers, connectors, array disks, and virtual disks
NA

Server Administrator Change Management MIB

The Server Administrator Change Management MIB (filename dellcm.mib) provides management data that allows you to monitor the inventory of devices and applications with SNMP management applications.
The following table describes each Server Administrator Change Management MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Change Management MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.< MIB group. See the relevant section for more information about the MIB objects defined in a MIB group.
Table 5. Server Administrator Change Management MIB Sections in This Guide
Section Topics MIB Group Number
24 Change Management Group - describes the
MIB group number
inventory data provided by the Change Management MIB that allows users to monitor devices and software present on a particular managed computer chassis
> where <
MIB group number
> is the MIB group number assigned to the
10899
14

Dell Remote Access Controller Out-of-Band MIB

The Dell Remote Access Controller Out-of-Band MIB (filename dellRAC.mib) provides management data that allows you to monitor the Chassis Management Controller. This MIB also contains information on RAC legacy alerting. The following table describes each Dell RAC Out-of-Band group and lists the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group.
Table 6. Dell RAC Out-of-Band MIB
Section Topics MIB Group Number
25 The Dell RAC Out-of-Band MIB consists of information for the
following groups:
Product Information
Chassis Status
Chassis Power
CMC Power Information
CMC PSU Information
Chassis Alerts
Legacy Alerting
2

How This Guide Defines Technical Terms

The following table provides information about where to find definitions for technical terms in this reference guide.
Table 7. Where to Find Definitions for Technical Terms
Type of Definition See
Basic SNMP vocabulary. Introduction
MIB-group-specific variable values. MIB-group-specific MIB variables contain links to the tables that define these values in the last section of the section in which these variables are used.
Systems management terms, acronyms, and commonly managed components referred to in this reference guide.
Server Administrator-standard data types that specify variable values in this reference guide.
Sections 3, 5, 7, 8, 9, and 11 through 18.
Glossary
web site at dell.com/support/manuals.
Appendix A, Standard Data Type Definitions.
available on the Dell Support

Basic Terminology

It is important to have a good understanding of the key technical terms used in this guide. This guide provides definitions for all essential terms used in describing the Server Administrator MIBs. For definitions on all essential terms and acronyms, see the
Glossary
available on the Dell Support website at dell.com/support/manuals.

Frequently Used Terms in Variable Names

The following terms are frequently used in the name of a MIB variable:
Capability refers to the actions an object can perform, or to actions that can be taken by the object. Hot-pluggable is an example of a capability. If a card is hot-pluggable, it can be replaced while a system is running. Capability settings refer
15
to the capabilities of the object that the user can select from and activate if desired. Capability settings allow users of the server administrator to predetermine how an object behaves under specific conditions.
Settings are the conditions of a manageable object that determine what happens when a certain value is detected in a component. For example, a user can set the upper critical threshold of a temperature probe to 75 degrees Celsius. If the probe reaches that temperature, the setting causes an alert to be sent to the management console. Some settings, when reached, can trigger a system shutdown or other response to prevent damage to the system.
State refers to the condition of an object that has more than one condition. For example, an object may be in a or in an
enabled
state.
Status refers to the health of an object or how the object is functioning. For example, the status of a temperature probe that is measuring acceptable temperatures would be reported as normal. When the probe begins reading temperatures that exceed limits set by the user, it reports a critical status.
not ready

Tables

This reference guide contains two types of tables: tables that are used to organize and define variable values and tables that define MIB objects. Readers must understand the difference between these two types of tables.
SNMP Tables
Most of the MIB objects defined in this reference guide are organized into SNMP tables. SNMP tables organize data into two-dimensional structural arrays. In SNMP, objects that have a relationship to other objects are called columnar objects. Columnar objects are objects used to form lists and tables. When a MIB group is divided into one or more
table
discrete tables, the word Universal Unique Identifier (UUID). The UUID object has a type and a value that uniquely identifies an object such as a chassis. The table defines all of the variables that comprise the managed object UUID.
The following table is an example of an SNMP table. The table contains variables that must occur in a definite sequence. In the example table the defined variables are UUID Chassis Index, UUID Index, UUID Type, and UUID Value.
has a technical meaning. An example is the section of this reference guide entitled
These objects comprise the Server Administrator definitions for the UUID.
Table 8. UUID Table
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.20
Description Defines the UUID table.
Syntax SEQUENCE OF UUIDTableEntry
Access Not accessible
Table 9. UUID Table Entry
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1
Description Defines the UUID table entry.
Syntax UUIDTableEntry
Access Not accessible
Index
uUIDTable
uUIDTableEntry
uUIDIndex
16
Table 10. UUID Chassis Index
,
uUIDchassisIndex
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only
Table 11. UUID Index
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.2
Description Defines the index of the UUID in a specified chassis.
Syntax DellObjectRange
Access Read-only
Table 12. UUID Type
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3
Description Defines the type of the UUID for this chassis.
Syntax DellUUIDType
uUIDchassisIndex
uUIDIndex
uUIDType
Access Read-only
Table 13. UUID Value
Name
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4
Description Defines the value of the UUID for this chassis.
Syntax Octet String (SIZE[16])
Access Read-only Read-only
uUIDValue

Section Organization

Sections in this reference guide are based on the Server Administrator MIBs, so the complexity of each section depends on the complexity of each MIB group. The first section provides a high-level introduction to the MIB group. If the group is defined by one or more tables, the second section lists these tables. The third section documents the variables that comprise the group, and if applicable, the variables that comprise the tables. The fourth section contains definitions for any Server Administrator-specific variables that are used in the section. The following example shows the typical content of these four sections:
17
1. BIOS Setup Control Group — This section explains the purpose of the MIB group and summarizes the major features of the component groups.
2. BIOS Group Tables — If there is more than one SNMP table for a group, this section lists all of the tables. For this BIOS group example, there are eight tables listed. In each section, double-clicking any table on the list takes you to that table.
– BIOS Setup Control Table – SCSI Control Table – Parallel Port Control Table – Serial Port Control Table – USB Control Table – IDE Control Table – Diskette Control Table – Network Interface Control Table
3. Variables that make up each table in the group — This section documents the variables for the eight tables that comprise the BIOS group.
4. BIOS Variable Values — This section explains any Server Administrator-specific variables and data types that are used in this section. In the BIOS group example, there are 17 unique, Server Administrator-specific variable meanings. Information on each Server Administrator-specific variable is presented in a formatted table.

Other Documents You May Need

In addition to this guide, you can access the following guides available on the Dell Support website at dell.com/support/ manuals. On the Manuals page, click Software Systems Management. Click the appropriate product link on the right­side to access the documents.
The
Server Administrator Messages Reference Guide
management console or on your operating system’s event viewer. This guide explains the text, severity, and cause of each message that the server administrator issues.
The
Server Administrator CIM Reference Guide
extension of the standard management object format (MOF) file. The Server-Administrator CIM provider documents supported classes of management objects.
The
Glossary
provides information on the terms used in this document.
lists the messages that you can receive on your systems
documents the Common Information Model (CIM) provider, an

Introduction to the Server Administrator SNMP Subagent

This guide provides formatted information drawn primarily from the MIB files written for the Server Administrator services that support the SNMP protocol.
For each of the variables defined in the MIBs, the following fields are specified:
Variable name
OID or unique identifying number
Description
Data type of the variable (for example: integer, string, octet string)
Whether the variable is accessible, not accessible, read-only, or read-write
Index or indexes, if applicable
For each MIB group that has unique variable definitions, tables are included in the last section of the section to explain the meaning of the terms.
Standards for writing MIBs are defined by the Internet Engineering Task Force (IETF). Structure of Management Information (SMI) is a standard that specifies the rules for defining the structure and type of managed objects and
18
events in a MIB. SMIv1 is specified in Request For Comments (RFC) 1155. The Server Administrator MIB conforms to the SMIv1 standard.
SNMP is a systems management standard originally designed for network management. SNMP manages much more than networks. Information Technology (IT) professionals use SNMP for monitoring and managing computer systems and the various components and peripherals supported by their systems.
SNMP standards are defined by the Internet Engineering Task Force (IETF). SNMP version 1 was published in August 1988 and is the most commonly supported version of SNMP. SNMP version 2 was first published in May 1993, but has not gained widespread market acceptance. SNMP version 3 was recently completed and has addressed security issues that exist in version 1.
All SNMP systems consist of one or more managed systems that provide data through an SNMP agent to a management system. The management system provides a user interface to view data from the managed systems. The management system and managed systems communicate over a network (typically through User Datagram Protocol/Internet Protocol [UDP/IP]).
The management system and a managed system communicate by means of a common data schema. SNMP MIB files define the structure, type, and values of the SNMP data. While MIBs can be standardized or enterprise specific, most operating systems supply SNMP agents for the standard MIB-I and MIB-II schemas. MIB-I defines a base set of standard management information for systems implementing the Internet Protocol (IP) suite. MIB-II defines characteristics of the system, characteristics of network interfaces, and characteristics of components of the IP on the system. In addition to the standard MIBs, many hardware vendors have defined MIBs that provide management data specific to their systems and peripheral devices.
Monitored data can be retrieved through SNMP using the Get command. Typically, this command requires the host name or IP address of the target machine as well as the OID of the data to retrieve. Exact details are dependent on the operating system and the development tools being used to create the management application. The Get command has a variant known as GetNext.

Management Information Base Object Identifiers

Each data class within a Management Information Base (MIB) is defined by an Object Identifier (OID). OIDs are unique across all MIBs. An OID consists of a series of digits separated by periods. The OID functions in a similar fashion to a phone number. The phone number 011-512-471-0000 uniquely identifies a single phone. The phone number can be broken down into a number of components to uniquely identify a phone. The first component, 011, is the country code for the United States. The second component, 512, identifies the area code for central Texas. The third component, 471, is the phone exchange for a large state university in the city of Austin. The final component, 0000, is the main switchboard.
There are two main differences between the phone number example and an actual OID. The first difference is that there are many more components in an OID, up to 128. The combination of these components is called an OID prefix. The second difference is that OIDs support the concept of indexes or keys. The OID prefix specifies the data class but does not specify an instance of the data within the class. Indexes can be used to identify the instances of a data class. These indexes are referred to as the OID suffix.
The assignment of values for each OID prefix component can be illustrated by using a tree structure. The following is an example of an OID assignment:
Table 14. ROOT
CCITT(0)
ISO(1)
ORG(3)
DOD(6)
19
INTERNET(1)
MGMT(2)
MIB(1)
EXPERIMENTA L(3)
PRIVATE(4)
ENTERPRISES(
1)
DELL (674)
SNMPv2(6)
In the preceding example, the OID prefix for the Dell enterprise would be 1.3.6.1.4.1.674.
The numbers in boldface type show the categories and numbers that apply to Server Administrator. All Server Administrator-defined OIDs consist of 1.3.6.1.4.1.674 followed by additional component values.

SNMP Security

SNMP version 1 has a very limited security mechanism. SNMP agents support the use of a community string, which is configured at each SNMP agent and is passed as a part of all SNMP request messages. There is no verification that the requester is actually a member of the specified community. As most system and network management data is not confidential, this limited security is acceptable for Get types of requests. On the other hand, this security is not acceptable for Set types of operations where an SNMP request could power off a system, reconfigure a redundant array of independent disks (RAID) card, and so on. Some vendors have chosen not to support SNMP Set operations for this reason. Server Administrator is able to support SNMP Set operations because its SNMP agents implement a hash/ digest mechanism to prevent unauthorized SNMP Set operations. One limitation of this practice is that only server administrator-developed SNMP management applications have the capability to support the hash/digest mechanism.
NOTE: The default SNMP agent configuration usually includes a SNMP community name such as public. For security reasons, change the SNMP community names from their default values. For information about changing SNMP community names, see the Support website at dell.com/support/manuals. For additional guidelines, see the Securing an SNMP Environment article, dated May 2003, in the Dell Power Solutions magazine. This magazine is also available at dell.com/ powersolutions .
NOTE: Server Administrator provides support to enable or disable SNMP Set operations. For more information on enabling or disabling SNMP Set operations in Server Administrator, see the
Administrator User’s Guide
the Dell Support web site at dell.com/support/manuals.
Dell OpenManage Server Administrator User’s Guide
available on the Dell
Dell OpenManage Server
or the
Dell OpenManage Server Administrator Command Line Interface User's Guide

Management Actions

Management actions can be performed using the SNMP Set command. These actions can consist of configuring a phone number for the system’s owner, rebooting a system, or changing the asset tag of the system. See the previous section, Security, for limitations on Set operations.
20
on

SNMP Traps

SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on. Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion. SNMP traps avoid these limitations of the polling method.
An SNMP trap is an asynchronous event indicating that something significant has occurred. This is analogous to a pager receiving an important message, except that the SNMP trap frequently contains all the information needed to diagnose a fault.
Two drawbacks to SNMP traps are that they are sent using UDP, which is not a guaranteed delivery mechanism, and that they are not acknowledged by the receiver.
An SNMP trap message contains the trap’s enterprise OID, the agent IP address, a generic trap ID, the specific trap ID, a time stamp, and zero or more variable bindings (varbinds). The combination of an enterprise OID and a specific trap ID uniquely identifies each Server Administrator-defined trap. A varbind consists of an OID and its value and provides additional information about the trap.
In order for a management system to receive SNMP traps from a managed system, the node must be configured to send traps to the management system. Trap destination configuration is dependent on the operating system. When this configuration is done, a management application on the management system can wait for traps and act on them when received.
For a list of traps supported by the Server Administrator Instrumentation Service, see Instrumentation Traps. For information on Server Administrator Storage Management traps, see Storage Management Alert Reference.
For a list of traps supported by the Remote Access Controller, see RAC Traps, BMC Traps and iDRAC7 Traps.
21
22

Dell OpenManage SNMP Version 7.2

This section contains information added or updated for the current release.

What’s New in This Release

Added support for Enhanced Messaging (EEMI), which includes unique system identifiers (system service tag, chassis service tag, and system FQDN) and message identifier, (Message ID) for enhanced SNMP trap varbinds. You can associate an event to the respective server using the unique system identifiers. For more information, see the
Dell Event Message Reference Guide
Added new varbinds for OpenManage Server Administrator Storage Management:
– Added the following new table for Tape Drive:
Storage Management Group MIB
* tapeDriveTable
* tapeDriveEntry
* tapeDriveNumber
* tapeDriveName
* tapeDriveVendor
* tapeDriveProductID
* tapeDriveNexusID
* tapeDriveBusType
* tapeDriveSASAddress
* tapeDriveMediaType
2
– Added MIB table for Traditional Trap Varbinds: Storage Management Alert MIB
* messageIDEvent
* descriptionEvent
* locationEvent
* objectNameEvent
* objectOIDEvent
* objectNexusEvent
* currentStatusEvent
* previousStatusEvent
– Added MIB table for Trap Enhanced Varbinds:
* enhancedMessageIDEvent
* systemFQDNEvent
* serviceTagEvent
* chassisServiceTagEvent
Added new enhanced varbinds for OpenManage Server Administrator :
23
– Added the following tables for Trap on Traditional and Enhanced Varbinds.
SNMP Traps: Traditional Varbinds:
* alertSystem
* alertTableIndexOID
* alertMessage
* alertCurrentStatus
* alertPreviousStatus
* alertData
Enhanced Varbinds:
* alertMsgID
* alertSystemFQDN
* alertServiceTag
* alertChassisServiceTag
Added support for an additional feature — DIMM ranking, in Memory Module.
Added new enhancements in iDRAC :
– Added new enhancements in iDRAC with SNMP supported version of v2c and v3.
– iDRAC7 MIB
* The iDRAC7 MIB file is now published in both types of SMI (Structure of Managed Information)
notations: SMIv1 and SMIv2. Previously it was only published in SMIv1 notation. Also, the name of the SMIv1 copy of the MIB file has changed. Previously it was named iDRAC-MIB.txt. Now it is named iDRAC-SMIv1.mib. The SMIv2 copy of the MIB file is named iDRAC-SMIv2.mib.
* Updated the lists in the iDRAC7 Supported SNMP Versions section. SNMPv3 queries are now
supported. And the SNMP v2c trap format is now supported.
* Added a new section on iDRAC7 SNMP Data Security Features.
* Added the following three additional new Trap variables:
alertDeviceDisplayNamex
alertMessageArguments
alertChassisServiceTag
* Added the following two new subgroups:
System Details Group
Storage Details Group
* Added the following five new objects under the System Information Group:
systemSystemID
systemOSVersion
systemRoomName
systemChassisSystemHeight
systemBladeGeometry
* Added the following one new object under the Status Group:
systemPowerState
* Added the following two new sets of System Trap Group traps:
Fiber Channel Traps
24
Temperature Statistics Traps
25
26
3

Instrumentation MIB Version Group

The Instrumentation Management Information Base (MIB) Version Group defines the attributes that identify the version of the Instrumentation MIB supported by the systems management software.
The mIBMajorVersionNumber, mIBMinorVersionNumber, and mIBMaintenanceVersionNumber attributes are scalar objects, meaning that they are not related to other MIB objects and are thus not placed in a table.

Management Information Base Major Version Number

Name
Object ID 1.3.6.1.4.1.674.10892.1.1.1.0
Description Defines the major version number of the version of this MIB supported by the
Syntax DellUnsigned8BitRange
Access Read-only
mIBMajorVersionNumber
systems management software. For example, if the MIB version is 1.2.3, the major version number is 1.
A major version number change indicates a major change in object functionality.

Management Information Base Minor Version Number

Name
Object ID 1.3.6.1.4.1.674.10892.1.1.2.0
Description Defines the minor version number of the version of this MIB supported by the
Syntax DellUnsigned8BitRange
Access Read-only
mIBMinorVersionNumber
systems management software. For example, if the MIB version is 1.2.3, the minor version number is 2.
A minor revision provides additional support for new objects as well as problem fixes.

Management Information Base Maintenance Version Number

Name
Object ID 1.3.6.1.4.1.674.10892.1.1.3.0
Description Defines the maintenance version number for the version of this MIB supported by
mIBMaintenanceVersionNumber
the systems management software. For example, if the MIB version is 1.2.3, the maintenance version number is 3.
27
Syntax DellUnsigned8BitRange
Access Read-only
28
4

Systems Management Software Group

The Systems Management Software Group allows users to see information about the standards and software that are supported by the agent of a particular managed computer chassis. The Systems Management Software Group classifies each computer chassis according to the systems management standard that the agent supports.
Additional objects define the universal resource locator (URL) of the systems management software and the language in which systems management information displays. Defining these objects enables users to manage a system using an internet browser. You can access Server Administrator using the secure hypertext transfer protocol (https) and a pre­assigned port number of 1311, or you can specify a port number of your own choosing.
NOTE: Using the SoftwareServer Preferences menu of Server Administrator, you can bind to either one IP address or to all IP addresses.
To manage a system locally using Server Administrator, type the following in the address field of your browser: https:// localhost:<1311 or
To manage a system remotely using Server Administrator, type one of the following in the address field of your browser:
https://<systemname>:<1311 or
number>

Systems Management Software

The following objects describe the fields for server administrator systems management information. The systems management software variables are scalar objects, meaning that they are not related to other management information base (MIB) objects and are thus not placed in a table.
Table 15. Systems Management Software Name
user-specified port number>
user specified port number>
or https://<IP address>:<1311 or
user specified port
Name
Object ID 1.3.6.1.4.1.674.10892.1.100.1
Description Defines the systems management software product name.
Syntax DellString
Access Read-only
Table 16. Systems Management Software Version Number Name
Name
Object ID 1.3.6.1.4.1.674.10892.1.100.2
Description Defines the version number of the systems management software.
Syntax DellString
Access Read-only
systemManagementSoftwareName
systemManagementSoftwareVersionNumberName
29
Table 17. Systems Management Software Build Number
Name
systemManagementSoftwareBuildNumber
Object ID 1.3.6.1.4.1.674.10892.1.100.3
Description Defines the build number of the systems management software.
Syntax DellUnsigned16BitRange
Access Read-only
Table 18. Systems Management Software Description Name
Name
systemManagementSoftwareDescriptionName
Object ID 1.3.6.1.4.1.674.10892.1.100.4
Description Defines the description of the systems management software.
Syntax DellString
Access Read-only
Table 19. Systems Management Software Supported Protocol
Name
systemManagementSoftwareSupportedProtocol
Object ID 1.3.6.1.4.1.674.10892.1.100.5
Description Defines the systems management standards (SNMP or CIM) supported by the
systems management software.
Syntax SMSSupportedTypes (Systems Management Software Supported Standards)
Access Read-only
Table 20. Systems Management Software Preferred Protocol
Name
systemManagementSoftwarePreferredProtocol
Object ID 1.3.6.1.4.1.674.10892.1.100.6
Description Defines the preferred systems management standard for the systems
management software.
Syntax SMSSupportedTypes (Systems Management Software Supported Standards)
Access Read-only
Table 21. Systems Management Software Update Level Name
Name
systemManagementSoftwareUpdateLevelName
Object ID 1.3.6.1.4.1.674.10892.1.100.7
Description Defines the update level of the system management software.
Syntax DellString
Access Read-only
30
Loading...