Dell OpenManage Server Administrator Version 6.4 Quick Reference Guide

Dell OpenManage
Server Administrator

Version 6.4

SNMP Reference Guide

Notes and Cautions
NOTE: A NOTE indicates important information that helps you make better use of
your computer.
A CAUTION indicates potential damage to hardware or loss of data if instructions
__________________
Information in this publication is subject to change without notice. © 2003–2010 Dell Inc. All rights reserved.
Reproduction of these materials whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell™, the DELL™ logo, PowerEdge™, PowerVault™, and OpenManage™ are trademarks of Dell Inc. Microsoft registered trademarks of Microsoft Corporation in the United States and/or other countries. Intel
®
Itanium
, Pentium®, Atom®, and Celeron® are registered trademarks, and MMX™, Xeon™, and Core™ are trademarks of Intel Corporation in the United States and/or other countries. VESA registered trademark of the Video Electronics Standards Association. AMD™, AMD Athlon™, AMD Opteron™, AMD Sempron™, AMD Turion™, AMD Phenom™, and AMD Duron™ are trademarks of Advanced Micro Devices, Inc. VIA C7™ and VIA Eden™ are either trademarks or registered trademarks of VIA Technology, Inc. Crusoe™ and Efficeon™ are trademarks of Transmeta Corporation in the USA and other countries.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
®
and Windows® are either trademarks or
®
®
is a
,
December 2010

Contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . 15
Audience . . . . . . . . . . . . . . . . . . . . . . . . 15
What’s New in This Release
Supported SNMP Versions
. . . . . . . . . . . . . . 15
. . . . . . . . . . . . 15
What's New in Chassis Information Group . . . . 16
What's New in Storage Management Group
What's New in Dell Remote Access Controller
Out-of-Band Group . . . . . . . . . . . . . . . . . 17
Introduction to the SNMP Reference Guide
Server Administrator Instrumentation MIB
. . . . . . 17
. . . . 18
Server Administrator Remote Access MIB . . . . 21
Server Administrator Baseboard Management Controller, ASF MIB
. . . . . . . . . . . . . . . . 21
Server Administrator Field Replaceable
Unit MIB . . . . . . . . . . . . . . . . . . . . . . 21
Server Administrator Storage Management
MIB . . . . . . . . . . . . . . . . . . . . . . . . . 22
Server Administrator Change Management MIB
. . . . . . . . . . . . . . . . . . . . . . . . . 23
Dell Remote Access Controller Out-of-Band
MIB . . . . . . . . . . . . . . . . . . . . . . . . . 24
How This Guide Defines Technical Terms
. . . . . 24
SNMP Basic Terminology . . . . . . . . . . . . . 25
Frequently Used Terms in Variable Names
Ta bl es
. . . . . . . . . . . . . . . . . . . . . . . 28
. . . . 28
Section Organization . . . . . . . . . . . . . . . . 32
Other Documents You May Need
. . . . . . . . . 33
. . . 16
Contents 3
Introduction to the Server Administrator SNMP Subagent 33
SNMP Management Information Base Object Identifiers
. . . . . . . . . . . . . . . . . . . . . . 35
SNMP Security . . . . . . . . . . . . . . . . . . . 36
Management Actions
SNMP Traps
. . . . . . . . . . . . . . . . . . . . 37
. . . . . . . . . . . . . . . 37
2 Instrumentation MIB Version Group . . . . 39
Management Information Base Major Version
Number . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Management Information Base Minor Version Number
. . . . . . . . . . . . . . . . . . . . . . . . . . 40
Management Information Base Maintenance Version Number
. . . . . . . . . . . . . . . . . . . . . . . . . . 40
3 Systems Management Software Group . . 41
Systems Management Software . . . . . . . . . . . . 41
4 System State Group . . . . . . . . . . . . . . . . . 47
5 Chassis Information Group . . . . . . . . . . . 69
4 Contents
Systems Management Software Variable Values
. . . 45
System State Group Table . . . . . . . . . . . . . . . . 47
System State Table
. . . . . . . . . . . . . . . . . 47
System State Table . . . . . . . . . . . . . . . . . 49
Chassis Information Group Tables . . . . . . . . . . . 69
Chassis Information Table
UUID Table
. . . . . . . . . . . . . . . . . . . . . 82
. . . . . . . . . . . . . 69
POST Log Table . . . . . . . . . . . . . . . . . . . 84
Event Log Table
. . . . . . . . . . . . . . . . . . . 86
System BIOS Table . . . . . . . . . . . . . . . . . 89
Firmware Table
. . . . . . . . . . . . . . . . . . . 96
Intrusion Table . . . . . . . . . . . . . . . . . . . 99
Baseboard Table
. . . . . . . . . . . . . . . . . . 101
Chassis Information Group Variable Values
. . . . . . 106
6 Operating System Group . . . . . . . . . . . . 121
Operating System Group Table . . . . . . . . . . . . . 121
Operating System Table
Operating System Memory Table
. . . . . . . . . . . . . . 121
. . . . . . . . . 123
7 System Resource Group . . . . . . . . . . . . 127
System Resource Group Tables . . . . . . . . . . . . . 127
System Resource Map Table
System Resource Owner Table
System Resource Input/Output (I/O) Port Table
. . . . . . . . . . . . 127
. . . . . . . . . . 129
. . 132
System Resource Memory Table . . . . . . . . . . 135
System Resource Interrupt Table
. . . . . . . . . 138
System Resource Direct Memory Access
(DMA) Table . . . . . . . . . . . . . . . . . . . . 141
System Resource Group Variable Values
. . . . . . . . 144
8 Power Group . . . . . . . . . . . . . . . . . . . . . 149
Power Group Tables . . . . . . . . . . . . . . . . . . . 149
Power Unit Table
Power Supply Table
Voltage Probe Table
. . . . . . . . . . . . . . . . . . 149
. . . . . . . . . . . . . . . . 152
. . . . . . . . . . . . . . . . 156
Amperage Probe Table . . . . . . . . . . . . . . . 161
AC Power Switch Table
AC Power Cord Table
. . . . . . . . . . . . . . 167
. . . . . . . . . . . . . . . 169
Contents 5
Battery Table . . . . . . . . . . . . . . . . . . . . 172
Power Usage Table
. . . . . . . . . . . . . . . . . 174
Power Profile Table . . . . . . . . . . . . . . . . . 180
Power Group Variable Values
. . . . . . . . . . . . . . 183
9 Thermal Group . . . . . . . . . . . . . . . . . . . . 197
Thermal Group Tables . . . . . . . . . . . . . . . . . . 197
Cooling Unit Table
Cooling Device Table
Temperature Probe Table
Thermal Group Variable Values
. . . . . . . . . . . . . . . . . 197
. . . . . . . . . . . . . . . . 200
. . . . . . . . . . . . . 205
. . . . . . . . . . . . . 211
10 User Security Group . . . . . . . . . . . . . . . 215
User Security Group Table . . . . . . . . . . . . . . . 215
User Security Table
. . . . . . . . . . . . . . . . . 215
11 Remote Flash BIOS Group . . . . . . . . . . . 219
Remote Flash BIOS Group Table . . . . . . . . . . . . 219
Remote Flash BIOS Table
Remote Flash BIOS Variable Values
. . . . . . . . . . . . . . 219
. . . . . . . . . . 222
12 Port Group . . . . . . . . . . . . . . . . . . . . . . . 225
6 Contents
Port Group Tables . . . . . . . . . . . . . . . . . . . . 225
Pointing Port Table
Keyboard Port Table
Processor Port Table
. . . . . . . . . . . . . . . . . 225
. . . . . . . . . . . . . . . . 228
. . . . . . . . . . . . . . . . 231
Memory Device Port Table . . . . . . . . . . . . . 234
Monitor Port Table
. . . . . . . . . . . . . . . . . 237
Small Computer System Interface (SCSI) Port
Ta bl e . . . . . . . . . . . . . . . . . . . . . . . . 240
Parallel Port Table . . . . . . . . . . . . . . . . . 242
Serial Port Table
Universal Serial Bus (USB) Port Table
. . . . . . . . . . . . . . . . . . 246
. . . . . . . 250
Port Group Variable Values
. . . . . . . . . . . . . . . 253
13 Device Group . . . . . . . . . . . . . . . . . . . . 259
Device Tables . . . . . . . . . . . . . . . . . . . . . . 259
Pointing Device Table
Keyboard Device Table . . . . . . . . . . . . . . . 262
Processor Device Table
Processor Device Status Table
Cache Device Table . . . . . . . . . . . . . . . . 275
Memory Device Table
Memory Device Mapped Address Table
Generic Device Table . . . . . . . . . . . . . . . 292
PCI Device Table
PCI Device Configuration Space Table
Network Device Table . . . . . . . . . . . . . . . 301
Managed System Services Device Table
SD Card Unit Table
SD Card Device Table . . . . . . . . . . . . . . . 314
Device Group Variable Values
. . . . . . . . . . . . . . . 260
. . . . . . . . . . . . . . 265
. . . . . . . . . . 273
. . . . . . . . . . . . . . . 281
. . . . . . 289
. . . . . . . . . . . . . . . . . . 295
. . . . . . 298
. . . . . 309
. . . . . . . . . . . . . . . . . 311
. . . . . . . . . . . . . 318
14 Slot Group . . . . . . . . . . . . . . . . . . . . . . . 349
System Slot Group Table . . . . . . . . . . . . . . . . 349
System Slot Table
System Slot Variable Values
. . . . . . . . . . . . . . . . . 349
. . . . . . . . . . . . . . 353
Contents 7
15 Memory Group . . . . . . . . . . . . . . . . . . . . 363
Physical Memory Tables . . . . . . . . . . . . . . . . 363
Physical Memory Array Table
Physical Memory Array Mapped Table
Physical Memory Configuration Table
Physical Memory Logging Table . . . . . . . . . . 373
Redundant Memory Unit Table
Physical Memory Card Table
. . . . . . . . . . . 363
. . . . . . 368
. . . . . . . 371
. . . . . . . . . . . 375
. . . . . . . . . . . . 378
Memory Group Variable Values
. . . . . . . . . . . . . 381
16 BIOS Setup Control Group . . . . . . . . . . . 387
BIOS Group Tables . . . . . . . . . . . . . . . . . . . . 387
BIOS Setup Control Table
. . . . . . . . . . . . . 387
SCSI Control Table . . . . . . . . . . . . . . . . . 398
Parallel Port Control Table
Serial Port Control Table
. . . . . . . . . . . . . 400
. . . . . . . . . . . . . . 402
USB Control Table . . . . . . . . . . . . . . . . . 404
IDE Control Table
Diskette Control Table
. . . . . . . . . . . . . . . . . . 406
. . . . . . . . . . . . . . . 408
Network Interface Control Table . . . . . . . . . . 410
BIOS Group Variable Values
. . . . . . . . . . . . . . 413
17 Local Response Agent Group . . . . . . . . 423
LRA Group Tables . . . . . . . . . . . . . . . . . . . . 423
LRA Global Settings
LRA Global Settings Table
LRA Action Table
. . . . . . . . . . . . . . . . 423
. . . . . . . . . . . . . 424
. . . . . . . . . . . . . . . . . . 426
8 Contents
Local Response Agent Variable Values
. . . . . . . . . 428
18 Cost of Ownership Group . . . . . . . . . . . 431
Cost of Ownership Group Tables . . . . . . . . . . . . 431
Cost of Ownership Table
COO Service Contract Table
COO Cost Event Log Table
COO Warranty Table . . . . . . . . . . . . . . . . 446
COO Lease Information Table
COO Schedule Number Table
COO Options Table . . . . . . . . . . . . . . . . . 452
COO Maintenance Table
COO Repair Table
COO Support Information Table . . . . . . . . . . 458
COO Trouble Ticket Table
. . . . . . . . . . . . . . 431
. . . . . . . . . . . . 442
. . . . . . . . . . . . . 444
. . . . . . . . . . . 448
. . . . . . . . . . . 451
. . . . . . . . . . . . . . 454
. . . . . . . . . . . . . . . . . . 456
. . . . . . . . . . . . . 460
Cost of Ownership Variable Values
. . . . . . . . . . . 462
19 Remote Access Group . . . . . . . . . . . . . . 465
DRAC 4 and DRAC 5 . . . . . . . . . . . . . . . . . . . 465
Remote Access Table
DRAC III
. . . . . . . . . . . . . . . . . . . . . . . . . 471
Remote Access Table
Remote User Administration Table
Remote SNMP Trap Table
. . . . . . . . . . . . . . . 465
. . . . . . . . . . . . . . . 472
. . . . . . . . . 481
. . . . . . . . . . . . . 489
Remote Dial-Up Table . . . . . . . . . . . . . . . 494
Remote User Dial-In Configuration Table
Remote Dial-Out Table
. . . . . . . . . . . . . . . 501
Remote Access Variable Values
. . . . . . . . . . . . 504
. . . . . 498
20 Cluster Group . . . . . . . . . . . . . . . . . . . . 521
Cluster Group . . . . . . . . . . . . . . . . . . . . . . 521
Cluster Table
. . . . . . . . . . . . . . . . . . . . 521
Contents 9
Cluster Group Variable Values . . . . . . . . . . . . . 524
21 Baseboard Management Controller
Group . . . . . . . . . . . . . . . . . . . . . . . . . . . 525
Baseboard Management Controller Group Tables . . . 525
Baseboard Management Controller Table
. . . . . 525
Baseboard Management Controller Serial Interface Table
. . . . . . . . . . . . . . . . . . . 529
Baseboard Management Controller LAN
Interface Table . . . . . . . . . . . . . . . . . . . 533
Baseboard Management Controller Group Variable Values
. . . . . . . . . . . . . . . . . . . . . . . . . . 537
22 Field Replaceable Unit Group . . . . . . . . 541
Field Replaceable Unit Group Tables . . . . . . . . . . 541
Field Replaceable Unit Table
. . . . . . . . . . . . 541
23 Storage Management Group . . . . . . . . . 547
10 Contents
Field Replaceable Unit Group Variable Values
. . . . . 545
Storage Management Group . . . . . . . . . . . . . . 547
Storage Management Information Group
Global Data Group
Physical Devices Group
Controller Table
. . . . . . . . . . . . . . . . . . . . 550
. . . . . . . . . . . . . . . . . 556
. . . . . . . . . . . . . . . . . . . 557
. . . . . . . . 549
Channel Table . . . . . . . . . . . . . . . . . . . 577
Enclosure Table
Array Disk Enclosure Connection Table
. . . . . . . . . . . . . . . . . . . 582
. . . . . . 607
Array Disk Channel Connection Table . . . . . . . 609
Fan Table
Fan Connection Table
. . . . . . . . . . . . . . . . . . . . . . 612
. . . . . . . . . . . . . . . 618
Power Supply Table . . . . . . . . . . . . . . . . 620
Power Supply Connection Table
. . . . . . . . . . 625
Temperature Probe Table . . . . . . . . . . . . . 627
Temperature Probe Connection Table
Enclosure Management Module Table
. . . . . . . 632
. . . . . . 634
Enclosure Management Module Connection
Ta bl e . . . . . . . . . . . . . . . . . . . . . . . . 639
Battery Table
. . . . . . . . . . . . . . . . . . . . 642
Battery Connection Table . . . . . . . . . . . . . 648
Logical Devices Group
Virtual Disk Table
. . . . . . . . . . . . . . . . . 650
. . . . . . . . . . . . . . . . . . 650
Array Disk Logical Connection Table . . . . . . . 660
Storage Management Event Group
. . . . . . . . . . . 663
24 Change Management Group . . . . . . . . . 667
Inventory Group . . . . . . . . . . . . . . . . . . . . . 667
Device Group
Device Group Table
Application Group
Application Group Table
Operating System Group
Inventory Collector Product Information
. . . . . . . . . . . . . . . . . . . . . . 668
. . . . . . . . . . . . . . . . 668
. . . . . . . . . . . . . . . . . . . . 670
. . . . . . . . . . . . . . 671
. . . . . . . . . . . . . . . . 673
. . . . . . . . 674
25 Dell Remote Access Controller
Out-of-Band Group . . . . . . . . . . . . . . . . 677
Product Information . . . . . . . . . . . . . . . . . . . 677
Chassis Status
DRsCMCChangeTime
Chassis Power
. . . . . . . . . . . . . . . . . . . . . . 681
. . . . . . . . . . . . . . . 690
. . . . . . . . . . . . . . . . . . . . . . 691
Contents 11
CMC Power Information . . . . . . . . . . . . . . . . . 692
CMC PSU Information
Chassis Alerts
Legacy Alerting
. . . . . . . . . . . . . . . . . . 696
. . . . . . . . . . . . . . . . . . . . . . 698
. . . . . . . . . . . . . . . . . . . . . 700
26 Traps . . . . . . . . . . . . . . . . . . . . . . . . . . . 703
Trap Variables . . . . . . . . . . . . . . . . . . . . . . 704
Understanding the Trap Description
Understanding Trap Severity
Instrumentation Traps
Miscellaneous Traps
. . . . . . . . . . . . . . . . . . 710
. . . . . . . . . . . . . . . . 710
Temperature Probe Traps . . . . . . . . . . . . . 712
Cooling Device Traps
Voltage Probe Traps
. . . . . . . . . . . . . . . . 715
. . . . . . . . . . . . . . . . 717
Amperage Probe Traps . . . . . . . . . . . . . . . 719
Chassis Intrusion Traps
Redundancy Unit Traps
Power Supply Traps . . . . . . . . . . . . . . . . 725
Memory Device Traps
Fan Enclosure Traps
. . . . . . . . . . . . . . . 727
. . . . . . . . . . . . . . . . 728
AC Power Cord Traps . . . . . . . . . . . . . . . . 729
Hardware Log Traps
. . . . . . . . . . . . . . . . 730
Processor Device Status Traps
Pluggable Device Traps . . . . . . . . . . . . . . 733
Battery Traps
SD Card Device Traps
. . . . . . . . . . . . . . . . . . . . 734
. . . . . . . . . . . . . . . 736
. . . . . . . . . . 705
. . . . . . . . . . . . . . 710
. . . . . . . . . . . . . . 722
. . . . . . . . . . . . . . . 723
. . . . . . . . . . 731
12 Contents
RAC Traps
BMC Traps
. . . . . . . . . . . . . . . . . . . . . . . . 737
. . . . . . . . . . . . . . . . . . . . . . . . 743
27 Storage Management Alert
Reference
Alert Monitoring and Logging . . . . . . . . . . . . . . 749
. . . . . . . . . . . . . . . . . . . . . . . 749
Viewing Alerts
Alert Severity Levels
SNMP Support for Storage Management Alerts
SNMP Trap Forwarding
SNMP Trap Definitions
. . . . . . . . . . . . . . . . . . . . . 750
. . . . . . . . . . . . . . . . . . 750
. . . . 751
. . . . . . . . . . . . . . 751
. . . . . . . . . . . . . . . 752
SNMP Trap Variables . . . . . . . . . . . . . . . 752
Viewing SNMP Traps
Alert Descriptions and Corrective Actions
. . . . . . . . . . . . . . . . . . 753
. . . . . . . 753
A Standard Data Type Definitions . . . . . . 755
Common Data Types . . . . . . . . . . . . . . . . . . . 755
Variables with Data Types of State Capabilities and State Capabilities Unique
Dell Status Data Types
Dell Date
. . . . . . . . . . . . . . . . . . . . . . . . . 759
Full Dates
. . . . . . . . . . . . . . . . . . . . . . 760
. . . . . . . . . . . . . . . . 756
. . . . . . . . . . . . . . . . . 758
B SNMP Sample Output . . . . . . . . . . . . . . 761
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 767
Contents 13
14 Contents
1

Introduction

This reference guide provides information about the Simple Network Management Protocol (SNMP) Management Information Base (MIB) which is applicable for Dell OpenManage Version 6.4.
NOTE: This guide contains information that may also be applicable to earlier
OpenManage supported platforms.
This introduction is divided into two sections. The first section, "Introduction to the SNMP Reference Guide" on page 17, explains the SNMP Reference Guide design. All essential Simple Network Management Protocol (SNMP) terms are defined in this section. Some of the vocabulary may seem complex and unfamiliar to system administrators who are using SNMP for the first time. SNMP experts can skim this section, and beginners can read the section more carefully.
The second section, "Introduction to the Server Administrator SNMP Subagent" on page 33, is a more technical introduction to the management information base (MIB) that underlies Server Administrator services.

Audience

This guide is intended for system administrators, network administrators, and anyone who wants to write SNMP MIB applications to monitor systems.

What’s New in This Release

This section lists the SNMP versions supported and changes to the Server Administrator MIBs in this release.

Supported SNMP Versions

Operating System Supported SNMP version
Windows SNMP v1 and v2c
Linux SNMP v1, v2c, and v3
Introduction 15

What's New in Chassis Information Group

Added the following MIB object to the Chassis Information Table:
Chassis Express Service Code Name
Added the following MIB object to the Baseboard Table:
Baseboard Express Service Code Name
Added the following Chassis Information Group Variable Values to the Firmware Type Table:
unifiedserverconfigurator
lifecyclecontroller

What's New in Storage Management Group

Physical Devices Group
Added the following MIB objects to the Controller Table:
Controller Encryption Mode
Controller CacheCade
Logical Devices Group
Added the following MIB objects to the Virtual Disk Table:
Virtual Disk Is CacheCade
Virtual Disk Disk Cache Policy
Added the following enumeration values to the Virtual Disk Write Policy, under the Virtual Disk Table:
9: Not Applicable
Added the following enumeration value to the Virtual Disk Read Policy, under the Virtual Disk Table:
9: Not Applicable

What's New in Dell Remote Access Controller Out-of-Band Group

Added the following MIB objects to the Chassis Status Table:
drsChassis FrontPanel Ambient Temperature
16 Introduction
drsCMC Ambient Temperature
drsCMC Processor Temperature

Introduction to the SNMP Reference Guide

This reference guide provides a formatted version of the following Management Information Base that are released with the current version of Dell OpenManage.
Management Information Base (MIB) Name
Server Administrator
Management Information Base (MIB) Filename
10892.mib
Instrumentation MIB
Remote Access MIB
Server Administrator Field
dcs3rmt.mib
dcs3fru.mib
Replaceable Unit MIB
Server Administrator
dcstorag.mib
Storage Management MIB
Server Administrator
dellcm.mib
Change Management MIB
Dell RAC Out-of-Band MIB
dellRAC.mib
Sections in this guide follow MIB groups and provide explanations and definitions for the terms used to define MIB objects. Content in this reference guide is organized as documented in the following subsections.
General Content
Table 1-1 describes the sections that provide general information about the MIBs documented in this guide.
Table 1-1. General Content Sections in This Guide
Section Topics MIB Group
Number
1 Introduction to SNMP basics and to the MIBs that
support Server Administrator services
NA
Introduction 17
Table 1-1. General Content Sections in This Guide
Section Topics MIB Group
26 Traps — describes in-band traps defined in the Server
Administrator Instrumentation MIB and out-of-band traps sent by the Remote Access Controller (RAC) and Baseboard Management Controller (BMC).
Appendix A Standard Data Type Definitions — defines standard
data types used in this reference guide.
Appendix B SNMP Sample Output — provides a sample SNMP
output.
(continued)
Number
5000
NA
NA

Server Administrator Instrumentation MIB

The Server Administrator Instrumentation MIB (filename 10892.mib) provides instrumentation data that allows you to monitor the health of a system with SNMP management applications. It provides:
Information about the status of temperatures, power supplies, voltages, currents, fans, and memory at key points in the system
Rapid access to detailed fault and performance information gathered by industry standard systems management agents
Version information for Basic Input/Output System (BIOS), firmware, and operating system
A detailed account of every cost of ownership (COO) detail about your system
In addition, traps are sent to report a change in status of the health of critical components.
The Server Administrator Instrumentation MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. Table 1-2 describes each Server Administrator Instrumentation MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Instrumentation MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1.<MIB group number>, where <MIB group number> is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group.
18 Introduction
Table 1-2. Server Administrator Instrumentation MIB Sections
in This Guide
Section Topics MIB Group
Numbers
2 Instrumentation MIB Version Group — defines version
numbers of the Instrumentation MIB
3 Systems Management Software Group — defines information
about the systems management software and the supported systems management standards
4 System State Group — defines status, state, and redundancy for
a system and its components
5 Chassis Information Group — defines chassis types, events, and
indicators
6 Operating System Group — defines variables for name, version,
service pack, and other information about a system’s operating system
7 System Resource Group — defines variables for input/output
ports, memory, interrupts, and direct memory access
8 Power Group — defines variables for power units, power
supplies, and their current and voltage probes
9 Thermal Group — defines variables for temperature probes and
cooling devices
10 User Security Group — defines variables for creating and
modifying user accounts
11 Remote Flash BIOS Group — defines variables for updating the
system’s BIOS remotely
12 Port Group — defines variables for major port types such as
keyboard, monitor, small computer system interface (SCSI), Universal Serial Bus (USB), and parallel and serial ports
13 Device Group — defines variables for pointing, keyboard,
processor, cache, memory, and personal computer interface devices
14 Slot Group — defines variables for the system’s slots 1200
1
100
200
300
400
500
600
700
800
900
1000
1100
Introduction 19
Table 1-2. Server Administrator Instrumentation MIB Sections
in This Guide
Section Topics MIB Group
15 Memory Group — defines variables for the system’s
physical memory
16 BIOS Setup Control Group — defines variables for BIOS
functions such as boot sequence, speakers, Wake on the local area network (LAN), diskettes, ports, and network interface controllers (NIC)
17 Local Response Agent Group — defines variables for global
settings and actions. These variables allow users to predetermine how the system responds to a particular type of event
18 Cost of Ownership Group — defines variables for tracking data
on the system’s service contract, lease, repair records, trouble tickets, and so on
20 Cluster Group — defines variables for systems that operate as a
cluster
21 Baseboard Management Controller Group — provides
information about the Baseboard Management Controller (BMC) that may be present in your system. In addition to providing general information about the BMC, this group provides information about the serial and local area network (LAN) interfaces of the BMC
26 Traps — defines the types of alerts that can be sent to report the
status of critical components
(continued)
Numbers
1300
1400
1500
1600
1800
1900
5000
20 Introduction

Server Administrator Remote Access MIB

The Server Administrator Remote Access MIB (filename dcs3rmt.mib) provides in-band information about remote access hardware that may be present in your system.
The Server Administrator Remote Access MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. Table 1-3 describes each Server Administrator Remote Access MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Remote Access MIB groups are identified by the SNMP OID
1.3.6.1.4.1.674.10892.1.<MIB group number> where <MIB group number> is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group.
Table 1-3. Server Administrator Remote Access MIB Sections in This Guide
Section Topic MIB Group
Numbers
19 Remote Access Group — provides information about remote
access hardware that may be present in your system and defines variables for administrative users, SNMP trap destinations, modem configuration for dial-up networking, dial-in configuration, and dial-out destinations
1700

Server Administrator Baseboard Management Controller, ASF MIB

The Server Administrator BMC MIB (filename DcAsfSrv.mib) provides information about the traps sent by BMC. The Server Administrator BMC MIB structures its MIB objects that provide related information. The BMC MIB groups are identified by the SNMP OID 1.3.6.1.4.1.3183.1.1.<MIB group number>. The BMC MIB adheres to ASF 2.0 standard and hence the enterprise ID is wired for management (3183).

Server Administrator Field Replaceable Unit MIB

The Server Administrator Field Replaceable Unit MIB (filename dcs3fru.mib) provides information about field replaceable unit (FRU) hardware that may be present in your system.
Introduction 21
The Server Administrator Field Replaceable Unit MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. Table 1-4 describes each Server Administrator Field Replaceable Unit MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Field Replaceable Unit MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1.<MIB group number> where <MIB group number> is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group.
Table 1-4. Server Administrator Field Replaceable Unit MIB Sections in This Guide
Section Topic MIB Group
Numbers
22 Field Replaceable Unit Group — provides information about
field replaceable units that may be present in your system
2000

Server Administrator Storage Management MIB

The Server Administrator Storage Management MIB (filename dcstorag.mib) provides storage management data that allows you to monitor the health of storage resources with SNMP management applications.
Table 1-5 describes each Server Administrator Storage Management MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Storage Management MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.<MIB group number> where <MIB group number> is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group.
22 Introduction
Table 1-5. Server Administrator Storage Management MIB Sections in This Guide
Section Topics MIB Group
Numbers
23 Storage Management Group — consists of definitions for the
following MIB groups:
• Storage Management Group
• Storage Management Information Group
• Global Data Group
• Physical Devices Group
•Logical Devices Group
• Storage Management Event Group
27 Storage Management Alert Reference — lets you monitor the
health of storage resources such as controllers, connectors, array disks, and virtual disks
10893
NA

Server Administrator Change Management MIB

The Server Administrator Change Management MIB (filename dellcm.mib) provides management data that allows you to monitor the inventory of devices and applications with SNMP management applications.
Table 1-6 describes each Server Administrator Change Management MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Change Management MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.<MIB group number> where <MIB group number> is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group.
Table 1-6. Server Administrator Change Management MIB Sections in This Guide
Section Topics MIB Group
Number
24 Change Management Group - describes the inventory data
provided by the Change Management MIB that allows users to monitor devices and software present on a particular managed computer chassis
Introduction 23
10899

Dell Remote Access Controller Out-of-Band MIB

The Dell Remote Access Controller Out-of-Band MIB (filename dellRAC.mib) provides management data that allows you to monitor the Chassis Management Controller. This MIB also contains information on RAC legacy alerting. Table 1-7 describes each Dell RAC Out-of-Band group and lists the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group
Table 1-7. Dell RAC Out-of-Band MIB
Section Topics MIB Group
Number
25 The Dell RAC Out-of-Band MIB consists of information for
the following groups:
• "Product Information" on page 677
• "Chassis Status" on page 681
• "Chassis Power" on page 691
• "CMC Power Information" on page 692
• "CMC PSU Information" on page 696
• "Chassis Alerts" on page 698
• "Legacy Alerting" on page 700
2

How This Guide Defines Technical Terms

The following table provides information about where to find definitions for technical terms in this reference guide.
Table 1-8. Where to Find Definitions for Technical Terms
Type of Definition See
Basic SNMP vocabulary. "Introduction" on page 15
MIB-group-specific variable values. MIB-group-specific MIB variables contain links to the tables that define these values in the last section of the section in which these variables are used.
Systems management terms, acronyms, and commonly managed components referred to in this reference guide.
Sections 3, 5, 7, 8, 9, and 11 through 18.
Glossary available on the Dell Support website at support.dell.com/manuals.
24 Introduction
Table 1-8. Where to Find Definitions for Technical Terms
Type of Definition See
Server Administrator-standard data types that specify variable values in this reference guide.
(continued)
Appendix A, "Standard Data Type Definitions" on page 755.

SNMP Basic Terminology

It is important to have a good understanding of the key technical terms used in this guide. This guide provides definitions for all essential terms used in describing the Server Administrator MIBs. For definitions on all essential terms and acronyms, see the Glossary available on the Dell Support website at support.dell.com/manuals.
SNMP Master Agent
Typically, the SNMP agent on a managed system consists of one SNMP master agent and zero or more SNMP extension agents. This SNMP agent extendable structure facilitates the addition of new MIB modules without having to rebuild the entire SNMP agent and is invisible to SNMP management applications.
The SNMP master agent is responsible for receiving SNMP request protocol messages from SNMP management applications and sending SNMP response protocol messages. As part of processing SNMP request protocol messages, the SNMP master agent typically communicates with one or more SNMP extension agents. This communication does not involve standard SNMP protocol messages. The SNMP master agent uses an extension protocol that shields the SNMP extension agent from the standard SNMP protocol messages. The extension protocol also provides a way for SNMP extension agents to send SNMP event notifications (called traps in SNMPv1). The SNMP master agent is also responsible for sending SNMP event notification protocol messages to SNMP management applications.
On supported operating systems, the SNMP master agent is provided with the operating system. For example, on supported Microsoft Windows operating systems, the Windows SNMP service is the SNMP master agent. For information on the versions of the SNMP protocol supported by the SNMP master agent, see the operating system documentation.
Introduction 25
SNMP Extension Agent
The SNMP extension agent is responsible for registering the MIB objects that it supports with the SNMP master agent and then processing requests from the SNMP master agent for those MIB objects. The SNMP extension agent also initiates event notifications to the SNMP master agent. The SNMP extension agent does not receive or send standard SNMP protocol messages. The SNMP extension agent communicates with the SNMP master agent using an extension protocol defined by the SNMP master agent. The Server Administrator SNMP subagent is an SNMP extension agent.
Managed Object
A managed object is any item in a computer system that can be singled out for discovery, monitoring, or user intervention and correction.
NOTE: Not all managed objects described in this guide are supported by all systems.
MIB
A MIB acts as a structured road map for managed objects. As an Application Programming Interface (API), a MIB allows systems management tools to retrieve data maintained by an agent. The server administrator MIB is divided into several major groups of managed objects.
Variable
A variable is a component of a managed object. A temperature probe, for example, has a variable to describe its capabilities, its health or status, and certain indexes that you can use to locate specific temperature probes. One index for the probe would be the probe’s chassis number. Some systems may have multiple chassis—one chassis for the central processing unit and another chassis for storage. A chassis within a system can also have more than one temperature probe. Variables for a temperature probe include its capabilities, status, chassis index, and index.
One-Based Index
When an index is one-based, counting starts at 1. One-based indexing counts the first instance as 1, the second index as 2, and so on.
26 Introduction
Zero-Based Index
When an index is zero-based, counting starts at 0. Zero-based indexing counts the first instance as 0, the second index as 1, and so on.
Fields
Managed object variables contain fields. In this reference guide, managed object variables have the following fields defined:
Name is the exact string by which the variable is known in the MIB. MIB variables are named according to the following conventions:
Variable names start with a lowercase letter.
Spaces are not allowed between words in the variable name.
Acronyms are in uppercase letters, except when an acronym is the first word in the variable name.
With the exception of the first letter of the variable name and acronyms, all other words in the variable name start with capital letters.
The following variable names illustrate these conventions:
temperatureProbeLowerCriticalThreshold
coolingUnitIndex
pCIDeviceSpeed
Object Identifier (OID) is the unique number assigned to an object defined in a MIB. An OID is written as a sequence of subidentifiers in decimal notation. Each OID in this reference guide has a prefix that identifies the managed objects as belonging to Dell: 1.3.6.1.4.1.674. The additional numbers identify the MIB group and subgroup as well as the table entry number of any variables.
For example, the OID for the temperature probe managed object table is
700.20 and the variable for the location of the temperature probe (temperatureProbeLocationName) has an OID of 700.20.1.8. The full OIDs for these items are 1.3.6.1.4.1.674.10892.1.700.20 for the temperatureProbeTable and 1.3.6.1.4.1.674.10892.1.700.20.1.8 for the temperatureProbeLocation. For more information about the structure of OIDs, see "SNMP Management Information Base Object Identifiers" on page 35.
Description is a brief explanation of what a particular managed object does.
Introduction 27
Syntax defines the data type in which the values of the variable must be expressed. Most variables in this reference guide use standard data types such as string or boolean. All data types that are unique to server administrator variables are defined at the end of the section in which they occur. Standard data types are defined in "Standard Data Type Definitions" on page 755.
Access specifies whether persons with administrative privileges can read but not modify the value of a variable (read only) or can both read and modify the value of a variable (read-write).

Frequently Used Terms in Variable Names

The following terms are frequently used in the name of a MIB variable:
Capability refers to the actions an object can perform, or to actions that can be taken by the object. Hot-pluggable is an example of a capability. If a card is hot-pluggable, it can be replaced while a system is running. Capability settings refer to the capabilities of the object that the user can select from and activate if desired. Capability settings allow users of the server administrator to predetermine how an object behaves under specific conditions.
Settings are the conditions of a manageable object that determine what happens when a certain value is detected in a component. For example, a user can set the upper critical threshold of a temperature probe to 75 degrees Celsius. If the probe reaches that temperature, the setting causes an alert to be sent to the management console. Some settings, when reached, can trigger a system shutdown or other response to prevent damage to the system.
State refers to the condition of an object that has more than one condition. For example, an object may be in a not ready or in an enabled state.
Status refers to the health of an object or how the object is functioning. For example, the status of a temperature probe that is measuring acceptable temperatures would be reported as normal. When the probe begins reading temperatures that exceed limits set by the user, it reports a critical status.

Tables

This reference guide contains two types of tables: tables that are used to organize and define variable values and tables that define MIB objects. Readers must understand the difference between these two types of tables.
28 Introduction
SNMP Tables
Most of the MIB objects defined in this reference guide are organized into SNMP tables. SNMP tables organize data into two-dimensional structural arrays. In SNMP, objects that have a relationship to other objects are called columnar objects. Columnar objects are objects used to form lists and tables. When a MIB group is divided into one or more discrete tables, the word table has a technical meaning. An example is the section of this reference guide entitled Universal Unique Identifier (UUID). The UUID object has a type and a value that uniquely identifies an object such as a chassis. The table defines all of the variables that comprise the managed object UUID.
The following table is an example of an SNMP table. The table contains variables that must occur in a definite sequence. In the example table the defined variables are UUID Chassis Index, UUID Index, UUID Type, and UUID Value.
Example SNMP Table
UUID Table
These objects comprise the Server Administrator definitions for the UUID.
Name uUIDTable
Object ID 1.3.6.1.4.1.674.10892.1.300.20
Description Defines the UUID table.
Syntax SEQUENCE OF UUIDTableEntry
Access Not accessible
UUID Table Entry
Name uUIDTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1
Description Defines the UUID table entry.
Syntax UUIDTableEntry
Access Not accessible
Index uUIDIndex, uUIDchassisIndex
Introduction 29
UUID Chassis Index
Name uUIDchassisIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1
Description Defines the index (one-based) of this chassis.
Syntax DellObjectRange
Access Read-only
UUID Index
Name uUIDIndex
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.2
Description Defines the index of the UUID in a specified chassis.
Syntax DellObjectRange
Access Read-only
UUID Type
Name uUIDType
Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3
Description Defines the type of the UUID for this chassis.
Syntax DellUUIDType
Access Read-only
30 Introduction