Dell 8100 Getting Started Guide

Page 1
Dell PowerConnect
ʬ
81xx Series Switch
Getting Started Guide
使用入门指南
入門指南
Guide de mise en route
Handbuch zum Einstieg
Panduan Pengaktifan
はじめに
Guia de Primeiros Passos
Руководство по началу работы
Guía de introducción
Başlangıç Kılavuzu
Regulatory Model: PC8132, PC8132F, PC8164, PC8164F
ʩʧʺʤʣʥʡʲʤ
ʪʩʸʣʮʺ
Page 2
Page 3
Dell PowerConnect
81xx Series Switch
Getting Started Guide
Regulatory Model: PC8132, PC8132F, PC8164, PC8164F
Page 4
Notes
NOTE: A NOTE indicates important information that helps you make better use of
your computer.
CAUTION: A CAUTION indicates potential damage to hardware or loss of data if
instructions are not followed.
____________________
Information in this publication is subject to change without notice. © 2012 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell™, the DELL logo, PowerConnect™, OpenManage™, ReadyRails™ , and trademarks of Microsoft Corporation in the United States and/or other countries.
Other trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
Tor x™
are trademarks of Dell Inc. Microsoft®, Windows® are registered
Regulatory Model PC8132, PC8132F, PC8164, PC8164F
February 2012 P/N JHCTM Rev. A00
Page 5

Contents

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . 5
Features . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2 Hardware Overview. . . . . . . . . . . . . . . . . . 6
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . 7
Quad-Port SFP Uplink Fixed Ports
Expansion Slot
UART Interface
System LEDs
. . . . . . . . . . . . . . . . . . . . . . . 8
. . . . . . . . . . . . . . . . . . . . . . . 8
. . . . . . . . . . . . . . . . . . . . . . . . 9
. . . . . . . . . . . . . 8
3 Installation . . . . . . . . . . . . . . . . . . . . . . . 11
Site Preparation . . . . . . . . . . . . . . . . . . . . . 11
Unpacking the Switch
Package Contents
Unpacking Steps
Rack Mounting the Switch
Rack Mounting Safety Considerations
Installing the Dell ReadyRails System
Installing the Switch
. . . . . . . . . . . . . . . . . . 11
. . . . . . . . . . . . . . . . . 11
. . . . . . . . . . . . . . . . . . 12
. . . . . . . . . . . . . . . 12
. . . . . . . 12
. . . . . . . 13
. . . . . . . . . . . . . . . . 18
Contents 3
Page 6
4 Starting and Configuring the Switch . . . 19
Connecting a Switch to a Terminal . . . . . . . . . . . 20
Booting the Switch
. . . . . . . . . . . . . . . . . . . . 21
Performing the Initial Configuration
Initial Configuration Procedure
Example Session
Next Steps
. . . . . . . . . . . . . . . . . . 23
. . . . . . . . . . . . . . . . . . . . . 26
. . . . . . . . . . . 21
. . . . . . . . . . . 22
4 Contents
Page 7

Introduction

This document provides basic information about the Dell PowerConnect 81xx series of switches, PC8132, PC8132F, PC8164, PC8164F, including how to install a switch and perform the initial configuration. For information about how to configure and monitor switch features, see the User’s Configuration Guide, which is available on the Dell Support website at support.dell.com/support for the latest updates on documentation and firmware.
This document contains the following sections:
Hardware Overview
Installation
Starting and Configuring the Switch

Features

The PowerConnect 8100 Series are highly scalable, non-stop networking switches for campus aggregation and core switching 10 GbE deployments. The family of Layer 3 switches delivers 10/40 GbE wire-speed performance required to power demanding Enterprise and business infrastructures, while enabling scalability and high density 10 GbE operation with simplified management.
PC8100 Series delivers high availability and redundancy for small core and aggregation deployments that helps grow your network to high density 10 GbE operation and to 40 GbE for the Enterprise core. The family delivers high density stacking with either 10GbE or 40GbE ports, manageable as a single logical unit, as well as redundancy with power supplies, fans and firmware images. Simplified management also includes a USB Rapid Deployment feature to expedite network addressing at bootup, as well as streamline firmware image installs across the entire stack. Flexible management options include an industry-standard CLI, remote management using the embedded web server, and support for SNMP-based management applications including Dell OpenManage Network Manager.
The PC8100 family includes storage networking support and iSCSI optimization. To simplify connectivity with Dell EqualLogic arrays, the iSCSI Auto-Configuration feature in all 8100 Series switches automatically detects the arrays and configures the switch for optimal throughput. This feature is enabled by default, streamlining the process to just connecting a cable. Connectivity with Dell Compellent arrays is also simplified with a single command configuration.
Introduction 5
Page 8
Dell designed the PowerConnect 8100 Series for energy savings from the power cord to the ports, starting with EEE-capable ports to reduce active and passive port power consumption for all ports. In addition to redundant power supplies that can operate efficiently in all modes, variable speed fans reduce consumption by adjusting their speed for their environment through multiple temperature monitors. Lastly, the PC8100 family includes Dell’s Lifetime Limited Warranty with Basic Hardware Service (repair or replacement) for life.

Hardware Overview

This section contains information about device characteristics and modular hardware configurations for the PowerConnect 81xx switches.
PowerConnect 81xx has the following physical dimensions:
440 x 460 x 44 mm (W x D x H).
17.32 x 18.11 x 1.73 inches (W x D x H).
PowerConnect 81xx has a chassis design with four kinds of solutions and 640 Gbps and 320 Gbps switching bandwidth as listed below:
1
PC8132F - 24 port SFP+ 10G + 40G/80G extension module
2
PC8164F - 48 port SFP+ 10G + 2port 40G QSFP + 40G/80G extension module
3
PC8132 - 24 port 10GBaseT + 40G/80G extension module
4
PC8164 - 48 port 10GBaseT + 2port 40G QSFP + 40G/80G extension module
The module slots can plug in three kinds of modules:
•SFP+
10G Base-T
•QSFP+
The system also provides one RS-232 interface RJ45 type console port and a dedicated Ethernet service port for OOB management functions.
The PC81xx has the following features:
Support one USB port
Forty-eight 10 Gbps ports for 1G/10G transceiver
6 Hardware Overview
Page 9
Two fixed 40 Gbps QSFP ports for 40G transceiver
One 80 Gbps expansion slots for SFP+, 10G Base-T and QSFP+ modules
On board high performance CPU system with large memory. XLP308H/256 MB NOR Flash/2GB DDR III RAM.
Temperature monitoring (TMP75)
Software readable thermal monitor
RTC time clock support
Hot plugging redundant power supply
Current monitoring for Power management
The fan is removable and can be managed
Standard 1U chassis high

Front Panel

The following image shows the PowerConnect 81xx front panel:
Figure 1. PowerConnect 81xx Front Panel
The front panel includes:
24/48 fixed 10G Base-T or SFP+ ports
Management port
USB 2.0 port
NOTE: LED display for System, fan and power status indicators are on the back
panel.
QSFP+ Ports
Hardware Overview 7
Page 10

Quad-Port SFP Uplink Fixed Ports

The PC8164 and PC8164F models feature two fixed QSFP ports, each providing the following features:
Four 10G ports with quad-breakout/QBO cable
One 40G port supporting CR4, SR4 and LR4 transceivers
Front panel port status LEDs
The QSFP connections can be used for stacking. Stacking is supported at distances of up to 100M.
NOTE: The QSFP modules can be used only for the PowerConnect 81xx-
series switches.

Expansion Slot

The 80 Gbps expansion slot supports the following modules:
SFP+ (four 10G ports)
10G Base-T (four 10G ports)
QSFP+ (may be configured as two 40G ports or up to 8 10G ports)
The modules are sold separately.

UART Interface

The UART (Universal Asynchronous Receiver Transmitter) port is modeled after the industry standard 16550 UART devices. The UART port provides serial communication capabilities, which allows communication with the model or other external devices using RS-232 protocol. A serial port provides a direct connection to the switch and allows you to access the CLI from a console terminal connected to the port through the provided serial cable (with RJ45 YOST to female DB-9 connectors).
The UART port is separately configurable and can be run as an asynchronous link from 1200 baud to 4M baud.
8 Hardware Overview
Page 11
The UART interface can be programmed with the following options:
5, 6, 7, or 8 character bits
1, 1.5, or 2 stop bits
Parity option
Even/odd parity (if parity option is enabled)
Sticky parity (if parity option is enabled)
The defaults are 9600 baud rate, 8 data bits, No Parity, 1 Stop Bit, No Flow Control.

System LEDs

The system contains light emitting diodes (LEDs) that provide indications about the System, Temp, Diag, Fan, Stack, and Locator status of the PowerConnect 81xx unit. Table 1 contains the status LED definitions:
Table 1. LED Definitions for System
Feature Detailed Description Comment
System LED
Temp LED
Diag LED
• Solid blue - Normal operation
• Blinking blue - Booting
• Solid red - Critical system error
• Blinking red - Non­critical system error (fan fail, power supply fail)
• Off - Normal temperature
• Solid amber - Overtemp
• Off - Normal operating
• Blinking green ­Diagnostic test running
On front panel
On back panel
a
On back panel
Hardware Overview 9
Page 12
Table 1. LED Definitions for System (continued)
911 15 1171375
owerConnect 8164
Feature Detailed Description Comment
Fan LED
• Solid green - Fan
On back panel
powered and at expected RPM
• Solid red - Fan failed
Stack LED
• Solid blue - Switch in
On back panel
stacking mode
• Solid green - Switch in stacking slave mode
• Off - Switch in stand alone mode
Locator LED
• Blinking blue - Locator
On back panel
function is enabled
• Solid blue - Locator function is disabled
a. The thermal sensors system temperature threshold is 75°C. When the threshold is exceeded, the Temp LED lights up to Amber.
Figure 2. Port LEDs
FAN 1
Console
OOB
Locator
Stack
Temp
Dlag
System LED
1212121
2
10 Hardware Overview
PowerConnect 8164
3
4
7
5
8
6
9
101112
15
13
14
17
16
20
18
23
21222319
24
Page 13

Installation

Site Preparation

Before installing the switch or switches, make sure that the chosen installation location meets the following site requirements:
Clearance
Allow clearance for cabling, power connections, and ventilation.
Cabling
radio transmitters, broadcast amplifiers, power lines, and fluorescent lighting fixtures.
Ambient Temperature
is 10° to 35ºC (50° to 95ºF).
NOTE: Decrease the maximum temperature by 1°C (1.8°F) per 300 m (985 ft.) above
900 m (2955 ft.).
Relative Humidity
(noncondensing) with a maximum humidity gradation of 10% per hour.

Unpacking the Switch

Package Contents
When unpacking each switch, make sure that the following items are included:
One PowerConnect switch
One RJ45-to-DB-9 female cable
Two sets of rail kits (no tools required)
Two PSUs (packed separately)
Two AC power cords (country/region specific)
Getting Started Guide
Safety and Regulatory Information
Warranty and Support Information
Software License Agreement
—There is adequate front and rear clearance for operator access.
—The cabling is routed to avoid sources of electrical noise such as
—The ambient switch operating temperature range
—The operating relative humidity is 8% to 85%
Installation 11
Page 14
Unpacking Steps
NOTE: Before unpacking the switch, inspect the container and immediately report
any evidence of damage.
1
Place the container on a clean, flat surface and cut all straps securing the container.
2
Open the container or remove the container top.
3
Carefully remove the switch from the container and place it on a secure and clean surface.
4
Remove all packing material.
5
Inspect the product and accessories for damage.

Rack Mounting the Switch

You may either place the switch on the rack shelf or mount the switch directly into a 19" wide, EIA-310-E compliant rack (four-post, two-post, or threaded methods). The Dell ReadyRails™ system is provided for 1U front-rack, and two-post installations. The ReadyRails system includes two separately packaged rail assemblies and two rails that are shipped attached to the sides of the switch.
WARNING: This is a condensed reference. Read the safety instructions in your
Safety, Environmental, and Regulatory information booklet before you begin.
NOTE: The illustrations in this document are not intended to represent a specific
switch.
Rack Mounting Safety Considerations
Rack loading—Overloading or uneven loading of racks may result in shelf or rack failure, causing damage to equipment and possible personal injury. Stabilize racks in a permanent location before loading begins. Mount components beginning at the bottom of the rack, then work to the top. Do not exceed your rack load rating.
Power considerations—Connect only to the power source specified on the unit. When multiple electrical components are installed in a rack, ensure that the total component power ratings do not exceed circuit capabilities. Overloaded power sources and extension cords present fire and shock hazards.
12 Installation
Page 15
Elevated ambient temperature—If installed in a closed rack assembly, the operating temperature of the rack environment may be greater than room ambient. Use care not to exceed the 50 degrees C maximum ambient temperature of the switch.
Reduced air flow—Install the equipment in the rack so that the amount of airflow required for safe operation of the equipment is not compromised.
Reliable earthing—Maintain reliable earthing of rack-mounted equipment. Pay particular attention to supply connections other than direct connections to the branch circuit, for example: use of power strips.
Product should not be mounted with the rear panel facing in the downward position.
Installing the Dell ReadyRails System
The ReadyRails rack mounting system is provided to easily configure your rack for installation of your switch. The ReadyRails system can be installed using the 1U tool-less method or one of three possible 1U tooled methods (two-post flush mount, two-post center mount, or four-post threaded).
Installation 13
Page 16
1U Tool-less Configuration (Four-post Square Hole or Unthreaded Round Hole)
1
With the ReadyRails flange ears facing outward, place one rail between the left and right vertical posts. Align and seat the rear flange rail pegs in the rear vertical post flange. In Figure 3, item 1 and its extractions illustrate how the pegs appear in both the square and unthreaded round holes.
Figure 3. 1U Tool-less Configuration
2
Align and seat the front flange pegs in the holes on the front side of the vertical post. See Figure 3, item 2.
3
Repeat this procedure for the second rail.
4
To remove each rail, pull on the latch release button on each flange ear and unseat each rail. See Figure 3, item 3.
14 Installation
Page 17
Two-post Flush-mount Configuration
1
For this configuration, the castings must be removed from the front side of each ReadyRails assembly. See Figure 4, item 1 on page 15. Use a Torx driver to remove the two screws from each front flange ear (on the switch side of the rail) and remove each casting. Retain the castings for future rack requirements. It is not necessary to remove the rear flange castings.
Figure 4. Two-post Flush-mount Configuration
2
Attach one rail to the front post flange with two user-supplied screws. See Figure 4, item 2.
Installation 15
Page 18
3
Slide the plunger bracket forward against the vertical post and secure the plunger bracket to the post flange with two user-supplied screws. See Figure 4, item 3.
4
Repeat this procedure for the second rail.
Two-post Center-mount Configuration
1
Slide the plunger bracket rearward until it clicks into place and secure the bracket to the front post flange with two user-supplied screws. See Figure 5, item 1.
Figure 5. Two-post Center-mount Configuration
2
Slide the back bracket towards the post and secure it to the post flange with two user-supplied screws. See Figure 5, item 2.
3
Repeat this procedure for the second rail.
16 Installation
Page 19
Four-post Threaded Configuration
1
For this configuration, the flange ear castings must be removed from each end of the ReadyRails assemblies. Use a Torx driver to remove the two screws from each flange ear and remove each casting. See Figure 6, item 1 on page 17. Retain the castings for future rack requirements.
2
For each rail, attach the front and rear flanges to the post flanges with two user-supplied screws at each end. See Figure 6, item 2 on page 17.
Figure 6. Four-post Threaded Configuration
Installation 17
Page 20
Installing the Switch
The switch may be mounted in the 1U front-rack and 1U two-post (flush and center) configurations. The following is an example of 1U front-rack configuration. The 1U two-post (flush and center) configurations, you can slide the switch into the rails in the same manner as the four-post configurations.
1U Front-rack Installation
The rails that are attached to the switch must be configured.
1
Attach the switch rails (inner chassis members) to the PC81xx switch. Figure 7, item 1 shows the detail for the front standoff with locking tab.
Figure 7. Attaching the Switch Rails
2
After both switch rails are installed, line them up on Ready-Rails previously mounted to the rack and slide the switch in until flush with front of rack. About 3inches prior to full insertion, the rail locking feature will engage to keep the switch from inadvertently sliding out of the rack and falling.
18 Installation
Page 21

Starting and Configuring the Switch

The following flow chart provides an overview of the steps you use to perform the initial configuration after the switch is unpacked and mounted.
Figure 8. Installation and Configuration Flow Chart
Connect Power and Console
Power On
Choose Option 2
Boot Menu (Special Functions)
Reboot
Ye s
Enter Boot
Menu?
No
Loading Program from Flash to RAM
Enter
Wizard?
No
Manual Initial Configuration
Advanced Configuration
Ye s
Easy Setup Wizard Configuration
Starting and Configuring the Switch 19
Page 22

Connecting a Switch to a Terminal

After completing all external connections, connect a terminal to a switch to configure the switch.
NOTE: Read the release notes for this product before proceeding. You can
download the release notes from the Dell Support website at support.dell.com/support.
NOTE: We recommend that you obtain the most recent version of the user
documentation from the Dell Support website at support.dell.com/support.
To monitor and configure the switch via serial console, use the RJ45 console port on the back panel of the switch to connect it to a VT100 terminal or to a computer running VT100 terminal emulation software. The console port is implemented as a data terminal equipment (DTE) connector.
The following equipment is required to use the console port:
VT100-compatible terminal or a desktop or a portable computer with a serial port running VT100 terminal emulation software,
HyperTerminal.
A serial cable (provided) with a RJ45 connector for the console port and DB-9 connector for the terminal.
Perform the following tasks to connect a terminal to the switch console port:
Connect the DB-9 connector on the serial cable to the terminal or
1
computer running VT100 terminal emulation software.
2
Configure the terminal emulation software as follows:
a
Select the appropriate serial port (for example, COM 1) to connect to the console.
b
Set the data rate to 9600 baud.
c
Set the data format to 8 data bits, 1 stop bit, and no parity.
d
Set the flow control to none.
e
Set the terminal emulation mode to
f
Select Terminal keys for Function, Arrow, and Ctrl keys. Ensure that
VT100
.
the setting is for Terminal keys (not Microsoft Windows keys).
such as Microsoft
20 Starting and Configuring the Switch
Page 23
NOTE: When using HyperTerminal with Microsoft Windows 2000, make sure
that you have Windows 2000 Service Pack 2 or later installed. With Windows 2000 Service Pack 2, the arrow keys function properly in HyperTerminal's VT100 emulation. Go to microsoft.com for more information about Windows 2000 service packs.
3
Connect the RJ45 connector on the cable directly to the PowerConnect 81xx RJ45 console port located on the back of the switch.

Booting the Switch

When the power is turned on, the switch goes through a power-on self-test (POST). POST runs every time the switch is initialized and checks hardware components to determine if the switch is fully operational before completely booting. If POST detects a critical problem, the program flow stops. If POST passes successfully, valid firmware is loaded into RAM. POST messages are displayed on the terminal and indicate test success or failure. The boot process runs for approximately 60 seconds.
With local terminal connected, you can invoke the Boot menu after the first part of the POST is completed. From the Boot menu, you can perform configuration tasks such as resetting the system to factory defaults, activating the backup image, or recovering a password. For more information about the Boot menu functions, see the CLI Reference Guide.

Performing the Initial Configuration

The initial configuration procedure is based on the following assumptions:
The PowerConnect switch was never configured before and is in the same state as when you received it.
The PowerConnect switch booted successfully.
The console connection was established, and the prompt appears on the screen of a VT100 terminal or terminal equivalent.
The initial switch configuration is performed through the console port. After the initial configuration, you can manage the switch from the already­connected console port or through a remote connection.
NOTE: The switch is not configured with a default user name, password, or
IP address.
Starting and Configuring the Switch 21
Dell Easy Setup Wizard
Page 24
Before setting up the initial configuration of the switch, obtain the following information from your network administrator:
The IP address to be assigned to the out-of-band (OOB) interface for device management.
The IP subnet mask for the OOB interface.
The IP address of the OOB interface default gateway.
These settings are necessary to allow the remote management of the switch through Telnet (Telnet client) or HTTP (Web browser).
Initial Configuration Procedure
You can perform the initial configuration by using the Dell Easy Setup Wizard or by using the CLI. The wizard automatically starts when the switch
configuration file is empty. You can exit the wizard at any point by entering [ctrl+z], but all configuration settings specified will be discarded, and the switch will use the default values.
NOTE: If you do not run the Easy Setup Wizard or do not respond to the initial Easy
Setup Wizard prompt within 60 seconds, the switch enters CLI mode.
For more information about performing the initial configuration by using the CLI, see the CLI Reference Guide. This Getting Started Guide shows how to use the Easy Setup Wizard for initial switch configuration. The wizard sets up the following configuration on the switch:
Establishes the initial privileged user account with a valid password. The wizard configures one privileged user account during the setup.
Enables CLI login and HTTP access to use the local authentication setting only.
Sets up the IP address for the OOB interface.
Sets up the SNMP community string to be used by the SNMP manager at a given IP address. You may choose to skip this step if SNMP management is not used for this switch.
22 Starting and Configuring the Switch
Page 25
Example Session
This section describes an Easy Setup Wizard session. The following values are used by the example session:
NOTE: There is no username, password, or ip address when the switch is unboxed
or set to factory defaults.
SNMP is not enabled.
The default user name, entered. The Wizard does not display the password as it is entered.
The OOB management interface uses assignment.
NOTE: In the example below, the possible user options or default values are
enclosed in [ ]. If you press <Enter> with no options defined, the default value is accepted. Help text is in parentheses.
The following example contains the sequence of prompts and responses associated with running an example Dell Easy Setup Wizard session, using the input values listed above.
After the switch completes the POST and is booted, the following text is displayed:
(Unit 1-Waiting to select management unit)>
Applying Global configuration, please wait ...
Welcome to Dell Easy Setup Wizard
root
, is accepted and a password of
192.168.2.1
admin123
for IP address
is
The Setup Wizard guides you through the initial switch configuration, and gets you up and running as quickly as possible. You can skip the setup wizard, and enter CLI mode to manually configure the switch. You must respond to the next question to run the setup wizard within 60 seconds, otherwise the system will continue with normal operation using the default system configuration. Note: You can exit the setup wizard at any point by entering [ctrl+z].
Would you like to run the setup wizard (you must answer this question within 60 seconds)? [Y/N] y
Starting and Configuring the Switch 23
Page 26
First:
Do you want to select the operational mode as Simple Mode? [Y/N] y
Step 1:
The system is not setup for SNMP management by default. To manage the switch using SNMP (required for Dell Network Manager) you can
. Set up the initial SNMP version 2 account now.
. Return later and setup other SNMP accounts. (For
more information on setting up an SNMP version 1 or 3 account, see the user documentation).
Would you like to setup the SNMP management interface now? [Y/N] n
Step 2:
Now we need to setup your initial privilege (Level 15) user account. This account is used to login to the CLI and Web interface. You may setup other accounts and change privilege levels later. For more information on setting up user accounts and changing privilege levels, see the user documentation.
To setup a user account:
Please enter the user name. [root]:
Please enter the user password:
Please reenter the user password:
Step 3:
Next, IP addresses are setup on the OOB (Out-Of-Band) Interface and/or the VLAN1 routing interface.
You can use these IP addresses to access the CLI, Web interface, or SNMP interface of the switch.
To access the switch through any Management Interface you can
24 Starting and Configuring the Switch
Page 27
. Setup the IP address for the Management Interface.
. Setup the default gateway if IP address is
manually configured on both routing and OOB interface.
Would you like to setup the Out-Of-Band interface now? [Y/N] y
Please enter the IP address of the device (A.B.C.D) or enter "DHCP" (without the quotes) to automatically request an IP address from the network DHCP server. [192.168.2.1]:
Please enter the IP subnet mask (A.B.C.D or /nn). [255.255.255.0]:
This is the configuration information that has been collected:
Operational Mode = Simple
User Account setup = root
Password = ********
Out-of-band IP address = 192.168.2.1 255.255.255.0
Final Step:
If the information is correct, please enter (Y) to save the configuration, and copy the settings to the start-up configuration file. If the information is incorrect, enter (N) to discard the configuration and restart the wizard: [Y/N] y
Thank you for using the Dell Easy Set up Wizard. You will now enter CLI mode.
Applying Interface configuration, please wait ...
console>
Starting and Configuring the Switch 25
Page 28
Next Steps
After completing the initial configuration described in this section, you can connect any of the front-panel switch ports to your production network for in-band remote management.
If you specified DHCP for the OOB management interface IP address, the interface will acquire its IP address from a DHCP server on the network. To discover the dynamically-assigned IP address, use the console port connection to issue the following command:
show ip interface out-of-band.
To access the Dell OpenManage Switch Administrator interface, enter the OOB management interface IP address into the address field of a Web browser. For remote management access to the CLI, enter the OOB management interface IP address into a Telnet or SSH client. Alternatively, you can continue to use the console port for local CLI access to the switch.
Your PowerConnect 81xx switch supports basic switching features such as VLANs, 802.1X, RADIUS and TACACS+. For more information on the features supported in Simple mode, see Simple Switch Mode: Port Aggregator Feature White Paper.
If the switch is configured to operate in Normal mode, it can also support features such as spanning tree protocol, as well as advanced Layer 3 features such as dynamic routing and multicast. Use the web-based management interface or the CLI to configure the features your network requires. For information about how to configure the switch features, see the User’s Configuration Guide or CLI Reference Guide available on the support site support.dell.com/support.
26 Starting and Configuring the Switch
Page 29
Dell PowerConnect
81xx 系列 交换机
使用入门指南
管制型号:
PC8132、PC8132F、PC8164
PC8164F
Page 30
注:“注”表示可以帮助您更好地使用计算机的重要信息。
小心:“小心”表示如果不遵循说明,就有可能损坏硬件或导致数据
丢失。
____________________
本出版物中的信息如有更改,恕不另行通知。
© 2012 Dell Inc.
未经
Dell Inc.
本文中使用的商标: 和
Torx™
其它国家/地区的注册商标。
本出版物中述及的其它商标和产品名称是指拥有相应商标和产品名称的公司或其制造的产 品。
Dell Inc.
版权所有,翻印必究。
书面许可,严禁以任何形式对这些材料进行复制。
Dell™DELL
Dell Inc.
的商标。
对本公司的商标和产品名称之外的其它商标和产品名称不拥有任何专有权。
徽标、
Microsoft
PowerConnect™OpenManage™ReadyRails™
®
Windows
®
是 Microsoft Corporation
在美国和/或
管制型号
PC8132、PC8132F、PC8164、PC8164F
2012 年 2 月P/N JHCTM Rev. A00
Page 31
目录
1 简介 . . . . . . . . . . . . . . 31
2 硬件概览 . . . . . . . . . . . . 32
功能. . . . . . . . . . . . . . . . . . . . . . . . . 31
前面板 . . . . . . . . . . . . . . . . . . . . . . . 33
四端口
扩充槽
UART
系统
上行链路固定端口
SFP
. . . . . . . . . . . . . . . . . . . . . . . 34
. . . . . . . . . . . . . . . . . . . . . . 34
接口
. . . . . . . . . . . . . . . . . . . . . . 35
LED
. . . . . . . . . . . 33
3 安装 . . . . . . . . . . . . . . 37
现场准备 . . . . . . . . . . . . . . . . . . . . . . 37
打开交换机包装
包装箱物品 . . . . . . . . . . . . . . .
打开包装步骤 . . . . . . . . . . . . . .
对交换机进行机架安装
机架安装安全说明 . . . . . . . . . . . .
安装 Dell ReadyRails 系统. . . . . . . . . .
安装交换机 . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . 37
37
38
. . . . . . . . . . . . . . . 38
38
39
43
目录 29
Page 32
4 启动和配置交换机 . . . . . . . . 44
将交换机连接至终端 . . . . . . . . . . . . . . . . 45
引导交换机
进行初始配置
. . . . . . . . . . . . . . . . . . . . . 46
. . . . . . . . . . . . . . . . . . . . 46
初始配置步骤 . . . . . . . . . . . . . . .
示例会话 . . . . . . . . . . . . . . . . .
接下来的步骤 . . . . . . . . . . . . . . .
47
48
51
30 目录
Page 33
简介
本说明文件提供有关
PC8132F、PC8164、PC8164F
初始配置。 有关如何配置和监测交换机功能的信息,请参阅 站上的《 明文件及固件的最新更新,请访问该站点,网址为
support.dell.com/support
本说明文件包含以下部分:
User's Configuration Guide
硬件概览 安装 启动和配置交换机
Dell PowerConnect 81xx
的基本信息,包括如何安装交换机和执行
》(用户配置指南)。要获取有关说
系列交换机
PC8132
Dell
支持网
功能
PowerConnect 8100
聚合和核心交换 和业务基础设施供电所需的 可扩展性和高密度
PC8100
于扩张您的网络到高密度 系列有 备、风扇和固件映像冗余,可提供高密度堆栈。简化的管理还包括 快速部署功能,以加速启动时的网络寻址,以及简化整个堆栈的固件映像 安装。灵活的管理选项包括工业标准 程管理,以及对包括
SNMP
PC8100
阵列的连接性,所有 检测阵列并配置交换机以获得最优吞吐量。此功能默认为启用,将该过程 简化为只需连接电缆。通过单个命令配置也简化了与 列的连接性。
Dell
从支持 以在所有模式下高效运行的冗余电源设备,变速风扇还可通过多个温度监 测器调整其环境速度来减少消耗。 最后, 有限保修和终生基本硬件服务(维修或更换)。
系列提供适用于小型核心与聚合部署的高可用性和冗余,这有助
10GbE 或 40GbE
的管理应用程序的支持。
系列包括存储网络支持和
设计了
PowerConnect 8100
的端口开始,降低所有端口的有源和无源端口功耗。除了可
EEE
系列为高度可扩展、不间断网络交换机,适用于校园
10 GbE
部署。第
10/40 GbE
10 GbE
运行。
10 GbE
端口、可作为单个逻辑单元管理,以及电源设
Dell OpenManage Network Manager
系列交换机中的
8100
层交换机系列提供对要求苛刻的企业
3
线速性能,同时通过简化管理实现
运行以及适用于企业核心的
、使用嵌入式
CLI
优化。为简化与
iSCSI
自动配置功能均可自动
iSCSI
Dell Compellent
系列,用于节省从电源线到端口的能源,
PC8100
系列还包括
40 GbE
服务器的远
Web
在内的基于
Dell EqualLogic
Dell
。该
USB
的终生
简介 31
Page 34

硬件概览

本节包含有关设备特性和 信息。
PowerConnect 81xx
440 x 460 x 44
17.32 x 18.11 x 1.73
PowerConnect 81xx
换带宽的机箱设计,如下所列:
1 PC8132F - 24 端口 SFP+ 10G + 40G/80G
2 PC8164F - 48 端口 SFP+ 10G + 2
3 PC8132 - 24
4 PC8164 - 48
模块插槽可插入三种模块:
SFP+
10G Base-T
QSFP+
系统还提供一个 务端口用于
PC81xx
具有以下功能:
支持一个 四十八个 两个固定 一个
80 Gbps
具有大内存的机载高性能
Flash/2GB DDR III RAM
温度监测 软件可读取温度监测
时钟支持
RTC
热插拔冗余电源设备
端口 端口
RS-232
管理功能。
OOB
USB
10 Gbps
40 Gbps QSFP
扩展插槽用于
(TMP75)
PowerConnect 81xx
的物理尺寸如下所示:
毫米(宽
英寸(宽
采用具有四种解决方案以及
10GBaseT + 40G/80G
10GBaseT + 2 端口 40G QSFP + 40G/80G
接口
端口
端口用于
高)。
x 厚 x
高)。
x 厚 x
端口
类型的控制台端口和一个用以网服
RJ45
1G/10G
端口用于
SFP+、10G Base-T 和 QSFP+
CPU
收发器
40G
系统。
交换机的模块化硬件配置的
640 Gbps 和 320 Gbps
扩展模块
40G QSFP + 40G/80G
扩展模块
扩展模块
收发器
模块
XLP308H/256 MB NOR
扩展模块
32 硬件概览
Page 35
电源管理的电流监测
风扇可拆卸,也可能损坏
标准
1U
机箱高
前面板
图表
1. PowerConnect 81xx
前面板包括:
四端口
PC8164 和 PC8164F
功能:
QSFP
PowerConnect 81xx
固定
24/48
管理端口
USB 2.0
注:系统、风扇和电源状态指示灯的 LED 显示在背面板上。
四个具有四芯 一个支持 前面板端口状态
连接可用于堆栈。在长达
注:QSFP 模块仅可用于 PowerConnect 81xx 系列交换机。
10G Base-T 或 SFP+
端口
SFP
上行链路固定端口
模块具有个固
/QBO
CR4、SR4 和 LR4
LED
前面板
电缆的
前面板
QSFP+
端口
端口
10G
收发器的
100M
端口
QSFP
距离支持堆栈。
端口,个端口提供以下
端口
40G
硬件概览 33
Page 36
扩充槽
80 Gbps
模块单独出售
UART
UART UART
它外部设备通信。可以行端口接连接到交换机,并可从通过提供 的行电缆连接到此端口( 端来访问
UART
运行。
UART
•5、6、7 或
•1、
默认设置为 控制
槽支持下列模块:
(四个
SFP+
10G Base-T
QSFP+
(可配置为两个
10G
(四个
端口)
10G
端口)
端口或多达八个
40G
10G
接口
(通用异步收发机)端口根据工业标准
端口提供行通信功能,可用于与该型或使用
RJ45 YOST
CLI
端口可单配置,并可作为从
接口可使用以下选项程:
字符位
8
1.5 或 2
奇偶校验选项 偶数/奇数校验(如果启用奇偶校验选项) 固定奇偶校验(如果启用奇偶校验选项)
停止位
8 个数据位、无奇偶校验、1 停止位、无
9600
1200
16550 UART
到内
DB-9
4M
端口)
设备模。
RS-232
连接器)的控制台
特的异步链路
协议的其
34 硬件概览
Page 37
系统
系统包含提供有关 堆栈和定位状态示的发光二极定义
功能 详细说明 注释
系统
温度
诊断
风扇
堆栈
定位器
a. 热感器系统温度阈值为 75C 超出阈值时,温度 LED 灯呈琥珀色亮起。
1.
LED
系统的
LED
LED
LED
LED
LED
LED
PowerConnect 81xx
定义
LED
设备的系统、温度、断、风扇、
(LED)
稳定蓝色
闪烁蓝色
稳定红色 错误
闪烁红色 错误(风扇故障、电源 设备故障)
熄灭
稳定琥珀色
熄灭
闪烁绿色 断测试
稳定绿色 开且处于预期
稳定红色
故障
稳定蓝色 模式
稳定绿色 从模式
熄灭
闪烁蓝色 启用
稳定蓝色 禁用
正常运行
-
正在引导
-
严重系统
-
非严重系统
-
正常温度
-
温度过高
-
正常运行
-
正在运行诊
-
风扇电源打
­ RPM
风扇出现
-
切换至堆栈
-
切换至堆栈
-
切换至独立模式
-
定位器功能
-
定位器功能
-
1 包含状态
在前面板上
在背面板上
a
在背面板上
在背面板上
在背面板上
在背面板上
LED
硬件概览 35
Page 38
911 15 1171375
owerConnect 8164
端口
2.
LED
System LED
Console
OOB
Locator
Stack
Temp
Dlag
FAN 1
3
1212121
4
2
PowerConnect 8164
7
5
8
6
9
101112
15
13
14
17
16
20
18
23
21222319
24
36 硬件概览
Page 39
安装

现场准备

安装交换机之前,请确保选择的安装位置满足以下现场要求:
空间正面和背面有足够空间供操作员进行操作。留出用于布线、电源 连接以及通风的空间。
布线布线应远离电气噪音干扰源,如无线电发射器、广播放大器、电
线以及荧光照明装置。
环境温度交换机的运行环境温度范围为
注:在 900 米(2955 英尺)以上,每升高 300 米(985 英尺)最高温度下降
1C (1.8F)
相对湿度运行相对湿度为 每小时
10%

打开交换机包装

包装箱物品
每台交换机的包装时,请保其中包含以下物
一台
PowerConnect
一根
RJ45 至 DB-9
两套滑轨套件(无需工具)
两个
两根交流电源线(特定于国家/地区)
使用入门指南
安全和管制信息
保修和支持信息
软件许可协议
(单独包装)
PSU
8% 到 85%
交换机
内孔电缆
10 至 35C(50 至 95F
(非冷凝),最大湿度变化梯度为
)。
安装 37
Page 40
打开包装步骤
注:在打开交换机的包装之前,先检查包装盒,如有任何损坏迹象,请立
即报告。
将包装盒放在整洁平坦的表面上,然后剪断固定包装盒的所有包
1
装带。 打开包装盒或取下包装盒盖。
2
从包装盒中小心取出交换机,然后将其放在稳固整洁的表面上。
3
取出所有包装材料。
4
检查产品及附件是否出现损坏。
5

对交换机进行机架安装

可将交换机置于机架搁板上或接安装到 要求的机中(四柱、两柱或线形方法)。
两柱安装。
1U
加到交换机侧面发运的滑轨。
警告:这是简要参考。请先阅读 “安全、环境和管制”信息手册中的安全
说明,再开始操作。
注:本说明文件中的示意图不用于表示特定交换机。
ReadyRails
系统包含个单包装的滑轨部件和
寸宽、
19 Dell ReadyRails
EIA-310-E
系统可供
机架安装安全说明
机架装载过载或装载不均匀可能导致搁板或机架出现故障,从而导致 损坏设备和可能造成人身伤害。在一个固定位置固定机架,再开始 装载。在机架底部开始安装组件,然后逐个往上安装到顶部请勿超 过机架载。
电源连接至设备上指定的电源。在机架中安装多个电子组件 时,总额功率过电路容量。过载电源和延长线 火灾危险
高的环境温度如果安装在封闭的机架件中,机架环境的操作温度 可能高于温。小心不要超过交换机的最大环境温度
更低的气流将设备安装在机架中,而不会影响安全操作设备所需的气 流
摄氏度。
50
38 安装
Page 41
的接地保持可的机架安装设备接地。 请特别注意提供连接而不 是接连接至支电
不能将产品背面板朝向下的位置安装。
使用电源线。
安装
Dell ReadyRails
提供
ReadyRails
工具的方或三种可能的
1U
柱居中安装或四线行安装)一安装
免工具配置(四柱方孔或无螺纹圆孔)
1U
1将 ReadyRails
系统
安装系统以轻松配置机便安装交换机。 可使用
需要工具的方法(两柱平齐安装、
1U
ReadyRails
凸缘吊耳朝外,将一个滑轨放在左右垂直柱之间。将
后端凸缘滑轨连接对准插入后端垂直柱凸缘中。在
及其提取图说明连接销在方孔和无螺纹圆孔中是怎样的。
1
3. 1U
免工具配置
系统。
图3
中,项
将前端凸缘连接对准插入垂直柱前端的孔中。 请参阅 图3,项
2
2
安装 39
Page 42
第二个滑轨重复此
3
卸下每个滑轨,动每个凸缘吊耳上的闩锁释按钮并拔出每个滑
4
请参阅 图3,项目 3。
轨。
两柱平齐安装配置
对于配置,必须从每个
1
图4,第 页
上的项 1。 用
40
ReadyRails
Torx
件的前端卸下件。 请参阅
螺丝刀卸下每个前端凸缘吊耳上的
颗螺钉(在滑轨交换机一卸下每个件。保留件供以后机 架需。不卸下后端凸缘铸件。
两柱平齐安装配置
4.
使用两户提供的螺钉将一个滑轨连接到前柱凸缘。 请参阅 图4,
2
2。
40 安装
Page 43
正对垂直柱向前滑动柱塞支架,使用用户提供的两颗螺钉柱塞
3
架固定到垂直柱凸缘。 对第二个滑轨重复此
4
两柱居中安装配置
后滑动柱塞支架,至其入到位,使用用户提供的两颗螺钉将
1
支架固定至前柱凸缘。
两柱居中安装配置
5.
请参阅 图4,项目 3。
请参阅 图5,项目 1。
朝柱子滑动后端支架,使用用户提供的两颗螺钉将其固定至柱子凸
2
请参阅 图5,项目 2。
第二个滑轨重复此
3
安装 41
Page 44
四柱线形配置
对于配置,必须
1
螺丝刀卸下每个前端凸缘吊耳上的两颗螺钉并卸下每个件。
Torx
参阅
图6, 页42
对于每个滑轨,使用用户提供的两颗螺钉将前端和后端凸缘连接至
2
凸缘端。
四柱线形配置
6.
ReadyRails
上的项 1。保留件供以后机架需
请参阅 图6,第 页
件的端卸下凸缘吊耳铸件。
上的项 2。
42
42 安装
Page 45
安装交换机
交换机可安装在 配置的示。 的方式将交换机滑入滑轨。
前机架安装
1U
必须配置连接交换机的滑轨
将交换机滑轨(内机箱成员)连接至
1
显示具有卡舌的前定位器的详情
连接交换机滑轨
7.
1U
1U
1U
双柱平齐和居中)配置,可以与四柱配置相同
双柱平齐和居中)配置中。下面是
PC81xx
交换机。7,项
1U
1
安装两个交换机滑轨后,在前安装到机架上的就绪滑轨
2
(Ready-Rails)
全插入前的
上将其成一行,滑入交换机机架前端平
英寸,将使用滑轨锁定功能使交换机避免意外
3
滑出机架并掉落
安装 43
Page 46

启动和配置交换机

以下流程图概述了在开交换机包装并安装交换机后,用于行初始 配置的步骤
安装和配置流程图
8.
连接电源和
控制台
开机
选择选项 2
引导菜单
(特殊功能)
重新引导
44 启动和配置交换机
进入引导
菜单?
将程序从闪存载
入到 RAM
进入
向导?
手动初始配置
简易安装向
导配置
高级配置
Page 47

将交换机连接至终端

完成所有部连接后,将终端连接交换机以配置该交换机。
注:在继续操作之前,请阅读本产品的版本注释。您可以从 Dell 支持网站
support.dell.com/support
注:我们建议您从 Dell 支持网站
户说明文件。
要通过控制台监测和配置交换机,请使用交换机背面板端口,将交换机连接
机。控制台端口可用作数据终端设备 要使用控制台端口,需要以下设备:
VT100
一根行电缆(附带),带有连接制台端口的 端的
兼容终端,或一台配备行端口运行
Microsoft HyperTerminal
连接器。
DB-9
要将终端连接交换机控制台端口,请执行以下务:
行电缆上的
1
机相连。照以下步骤配置仿真软件
2
a
择适当行端口(
b
将数据速率设置为
c
将数据格式设置为
d
将流制设置为
e
仿真设置为
f
择终作为箭头键和 端(而不是
注:在 Microsoft Windows 2000 中使用超级终端时,请确保已安装
Windows 2000 Service Pack 2 或更高版本。使用 Windows 2000 Service Pack 2 可以确保箭头键在超级终端的 VT100 仿真中正常工作。有关 Windows 2000 Service Pack 的详情,请访问
将电缆上的
3
RJ45
RJ45
制台端口。
下载版本注释。
support.dell.com/support
VT100
终端或在运行
(DTE)
VT100
连接器。
)的式机或便携式计算机。
连接器运行
DB-9
COM 1
特。
9600
个数位、1 个停止位以及无奇偶校验。
8
(无)。
none
VT100
Microsoft Windows
VT100
仿真软件的端或
)连接到制台。
设置用于
Ctrl
)。
microsoft.com
连接器连接至位于交换机背部的
获取最新版本的用
RJ45
终端仿真软件的
VT100
RJ45
仿真软件
连接器和连接
PowerConnect 81xx
控制
启动和配置交换机 45
Page 48

引导交换机

开电源时,交换机将行开机自测 机时行,用于检查硬件组件,以确定交换机在完全引导之前是否完全正 。如 功通过,将入一个有效的固件到 用于指自测是否成功。引导过程大约运行
连接本终端后,在 单。从 出厂默认活备映像或者恢复 有关详情,请参阅《
POST
引导单中,您可以执行配置务,如将系统置为
Boot
检测到严重问题,程序流就会停止。如
POST
CLI
第一部分完成后,可以调用
指南》。
(POST)。POST
中。
RAM
POST
60
每次初始化交换
信息示在终端上,
引导
Boot
引导
Boot
POST
单功能

进行初始配置

初始配置步骤基于以下假设条件:
PowerConnect
PowerConnect
制台连接已建立并且 终端或同等终端设备的屏幕上。
通过控制台端口执行初始交换机配置。完成初始配置后,可以通过连接 的控制台端口或远程连接管理交换机。
注:交换机未配置默认的用户名、密码和 IP 地址。
在设置交换机的初始配置之前,从网络管理员处获得以下信息:
要分
要通过 机,需要这设置。
接口的
OOB
接口默认网关
OOB
Telnet(Telnet
交换机前从进行过任何配置,其状态收到时
交换机导成功。
提示信息显示
IP
浏览器)来远程管理交换
(OOB)
子网掩码
IP
户端)或
安装向导
Dell
接口进行设备管理的
IP
HTTP(Web
VT100
46 启动和配置交换机
Page 49
初始配置步骤
可以使用 为时,将自动启动该向导。可以时通过的所有配置设置被丢弃,交换机将使用默认
注:如果不运行简易安装向导或在 60 秒内没有响应初始简易安装向导提
示,交换机会进入 CLI 模式。
有关使用 用入指南》说明如何使用简安装向导行初始交换机配置。该向导 设置交换机的以下配置:
建立拥权限初始户帐户以及有密码。在安装过中,该向 导将配置一个具有权限的用户帐户
启用
设置
设置 交换机不使用
安装向导
Dell
行初始配置的详情,请参阅《
CLI
登录
CLI
OOB
SNMP
HTTP
接口的
IP
管理器在指定
SNMP
CLI
访问,以便仅使用地验设置。
址要使用的
IP
管理,则可以选择跳过这一步。
行初始配置。交换机配置文件
[ctrl+z]
CLI
退出向导
指南》。 本《使
SNMP
团体字符。如果
启动和配置交换机 47
Page 50
示例会话
本节介绍了一个简易安装向导会话。示例会话将使用以下值:
注:当交换机从箱子中取出或设置为工厂默认值时,没有用户名、密码或
IP 地址。
注:在以下示例中,可能的用户选项或默认值包括在 [ ] 中。如果未定义选
以下示包含与使用上面列出的输入值运行 (
Dell
交换机完成
(Unit 1-Waiting to select management unit)>
Applying Global configuration, please wait ...
Welcome to Dell Easy Setup Wizard
The Setup Wizard guides you through the initial switch configuration, and gets you up and running as quickly as possible. You can skip the setup wizard, and enter CLI mode to manually configure the switch. You must respond to the next question to run the setup wizard within 60 seconds, otherwise the system will continue with normal operation using the default system configuration. Note: You can exit the setup wizard at any point by entering [ctrl+z].
启用。
SNMP
默认户名
,而且密码
root
admin123
已输入。在密码
时,导不会显示密码
管理接口使用
OOB
项,按 <Enter> 键将接受默认值。帮助文本在括号中。
192.168.2.1
来分
IP
Dell Easy Setup Wizard
安装向导)示例会话相关的提示序列和响应。
POST
引导后,将示以下文本信息:
Would you like to run the setup wizard (you must answer this question within 60 seconds)? [Y/N] y
48 启动和配置交换机
Page 51
First:
Do you want to select the operational mode as Simple Mode? [Y/N] y
Step 1:
The system is not setup for SNMP management by default. To manage the switch using SNMP (required for Dell Network Manager) you can
. Set up the initial SNMP version 2 account now.
. Return later and setup other SNMP accounts. (For
more information on setting up an SNMP version 1 or 3 account, see the user documentation).
Would you like to setup the SNMP management interface now? [Y/N] n
Step 2:
Now we need to setup your initial privilege (Level 15) user account. This account is used to login to the CLI and Web interface. You may setup other accounts and change privilege levels later. For more information on setting up user accounts and changing privilege levels, see the user documentation.
To setup a user account:
Please enter the user name. [root]:
Please enter the user password:
Please reenter the user password:
Step 3:
Next, IP addresses are setup on the OOB (Out-Of-Band) Interface and/or the VLAN1 routing interface.
You can use these IP addresses to access the CLI, Web interface, or SNMP interface of the switch.
To access the switch through any Management Interface you can
启动和配置交换机 49
Page 52
. Setup the IP address for the Management Interface.
. Setup the default gateway if IP address is
manually configured on both routing and OOB interface.
Would you like to setup the Out-Of-Band interface now? [Y/N] y
Please enter the IP address of the device (A.B.C.D) or enter "DHCP" (without the quotes) to automatically request an IP address from the network DHCP server. [192.168.2.1]:
Please enter the IP subnet mask (A.B.C.D or /nn). [255.255.255.0]:
This is the configuration information that has been collected:
Operational Mode = Simple
User Account setup = root
Password = ********
Out-of-band IP address = 192.168.2.1 255.255.255.0
Final Step:
If the information is correct, please enter (Y) to save the configuration, and copy the settings to the start-up configuration file. If the information is incorrect, enter (N) to discard the configuration and restart the wizard: [Y/N] y
Thank you for using the Dell Easy Set up Wizard. You will now enter CLI mode.
Applying Interface configuration, please wait ...
console>
50 启动和配置交换机
Page 53
接下来的步骤
完成本节所的初始配置后,您可以将任意前面板交换机端口连接到生 网络以便进行带内远程管理。
DHCP
口连接来发出以下命令:
show ip interface out-of-band
要访问 的字段入 问,请在 以继续使用控制台端口对交换机行本
您的
802.1X
请参阅简单交换机模式:端口聚合器功能白皮书。 如将交换机配置为在通模式下工作,也能支持如生成树协议之类的
功能,以及高级第 的管理接口或 能的信息,请参阅《 《
CLI Reference Guide
获取:
DHCP
服务器获得
Dell OpenManage Switch Administrator
Telnet 或 SSH
PowerConnect 81xx
RADIUS 和 TACACS+。
support.dell.com/support
来分配
址。要现动分配的
IP
OOB
层功能(如动态路由和多点传送)。使用基于
3
可配置您的网络需要的功能。 有关如何配置交换机功
CLI
Users Configuration Guide
》(
管理接口
OOB
管理接口
户端中
交换机支持基本的交换功能,如
CLI
IP
有关在简单模式中支持的功能的详情
指南),这些资料可从以下支持站点
址,该接口从网络上的
IP
址,请使用控制台
IP
界面,请在
址。要对
OOB
CLI
CLI
管理接口
访问。
》(用户配置指南)或
IP
Web
行远程管理访
址。或,可
VLAN
浏览
Web
启动和配置交换机 51
Page 54
52 启动和配置交换机
Page 55
Dell PowerConnect
81xx 系列 交換器
入門指南
管制型號: PC8132、PC8132F PC8164PC8164F
Page 56
註:「注」表示可以幫助您更好地使用電腦的重要資訊。
警示 : 「警示」表示如果不遵循說明,就有可能損壞硬體或導致資料丟失。
____________________
本出版物中的資訊如有變更,恕不另行通知。 © 2012 Dell Inc. 版權所有,翻印必究。
未經 Dell Inc. 書面許可,嚴禁以任何形式對這些材料進行複製。
本文中使用的商標: Dell™、DELL 徽標、PowerConnect™、OpenManage™、ReadyRails
Torx
Dell Inc. 的商標。Microsoft®、Windows® Microsoft Corporation 在美國和 /
和 其他國家 / 地區的注冊商標。
本出版物中述及的其他商標和產品名稱是指擁有相應商標和產品名稱的公司或其製造的產 品。Dell Inc. 對本公司的商標和產品名稱之外的其他商標和產品名稱不擁有任何專有權。
管制型號:PC8132PC8132FPC8164PC8164F
2012 2 P/N JHCTM Rev. A00
Page 57
目錄
1 簡介 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
2 硬體概覽 . . . . . . . . . . . . . . . . . . . . . . . . . 58
功能 . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
前板 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
四連接埠 SFP 上行連結固定連接埠
擴充槽
UART 介面
系統 LED
. . . . . . . . . . . . . . . . . . . . . . . . . . 60
. . . . . . . . . . . . . . . . . . . . . . . . 60
. . . . . . . . . . . . . . . . . . . . . . . . . 61
. . . . . . . . . . 60
3 安裝 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
現場準備. . . . . . . . . . . . . . . . . . . . . . . . . 63
打開交換器包裝
包裝箱物品
打開包裝步驟
對交換器進行機架安裝
機架安裝安全說明
安裝 Dell ReadyRails 系統
安裝交換器
. . . . . . . . . . . . . . . . . . . . 63
. . . . . . . . . . . . . . . . . . . . 63
. . . . . . . . . . . . . . . . . . . 64
. . . . . . . . . . . . . . . . 64
. . . . . . . . . . . . . . . . 64
. . . . . . . . . . . . . 65
. . . . . . . . . . . . . . . . . . . . 69
目錄 55
Page 58
4 啟動和設定 交換器 . . . . . . . . . . . . . . . . . 70
將交換器連接至終端機. . . . . . . . . . . . . . . . . 71
開機交換器
進行初始組態
初始組態步驟
示例工作階段
接下來的步驟
. . . . . . . . . . . . . . . . . . . . . . . 72
. . . . . . . . . . . . . . . . . . . . . . 72
. . . . . . . . . . . . . . . . . . . 73
. . . . . . . . . . . . . . . . . . . 74
. . . . . . . . . . . . . . . . . . . 77
56 目錄
Page 59
簡介
本說明文件介紹有關 Dell PowerConnect 81xx 系列交換器 PC8132 PC8132FPC8164PC8164F 的基本資訊,包括如何安裝交換器並進行 初始組態。 有關如何設定和監測交換器功能的資訊,請參閱 Dell 支援 We b 站點上的User's Configuration Guide(使用者組態指南)。要獲 取有關說明文件及韌體的最新更新,請存取該站點,網址為
http://support.dell.com/support
本說明文件包含以下部分:
硬體概覽
安裝
啟動和設定交換器
功能
PowerConnect 8100 系列為高度可延展、不間斷網路交換器,適用于校園 聚合和核心交換 10 GbE 部署。第 3 層交換器系列提供對要求苛刻的企業 和業務基礎結構供電所需的 10/40 GbE 線速效能,同時通過簡化管理實現 可延展性和高密度 10 GbE 運行。
PC8100 系列提供適用於小型核心與聚合部署的高可用性和冗餘,這有助 於擴張您的網路到高密度 10 GbE 運行以及適用於企業核心的 40 GbE。該 系列有 10GbE 40GbE 連接埠、可作為單個邏輯單元管理,以及電源設 備、風扇和韌體映像冗餘,可提供高密度堆疊。簡化的管理還包括 USB 快速部署功能,以加速啟動時的網路定址,以及簡化整個堆疊的韌體映像 安裝。靈活的管理選項包括工業標準 CLI、使用嵌入式 Web 伺服器的遠 端管理,以及對包括 Dell OpenManage Network Manager 在內的基於
SNMP 的管理應用程式的支援。
PC8100 系列包括存儲網路支援和 iSCSI 優化。為簡化與 Dell EqualLogic
陣列的連接性,所有 8100 系列交換器中的 iSCSI 自動組態功能均可自動 檢測陣列並設定交換器以獲得最優輸送量。此功能預設為啟用,將該過程 簡化為只需連接纜線。通過單個命令組態也簡化了與 Dell Compellent 陣 列的連接性。
Dell 設計了 PowerConnect 8100 系列,用於節省從電源線到連接埠的能 源,從支援 EEE 的連接埠開始,降低所有連接埠的有源和無源連接埠功 耗。除了可以在所有模式下高效運行的冗餘電源設備,變速風扇還可通過 多個溫度監測器調整其環境速度來減少消耗。 最後,PC8100 系列還包括 Dell 的終生有限保證和終生基本硬體服務(維修或更換)。
簡介 57
Page 60

硬體概覽

本節包含有關 交換器 PowerConnect 81xx 設備特性和模組化硬體組態的 資訊。
PowerConnect 81xx 的物理尺寸如下所示:
440 x 460 x 44
17.32 x 18.11 x 1.73
PowerConnect 81xx 採用具有四種解決方案以及 640 Gbps 320 Gbps 交 換頻寬的機箱設計,如下所列:
1
PC8132F - 24
2
PC8164F - 48
模組
3
PC8132 - 24
4
PC8164 - 48
模組
模組插槽可插入三種模組:
•SFP+
10G Base-T
•QSFP+
系統還提供一個 RS-232 RJ45 型的主控臺連接埠和一個專用乙太網 路服務連接埠用於 OOB 管理功能。
PC81xx 具有以下功能:
支援一個
四十八個
兩個固定
一個
80 Gbps
具有大記憶體的機載高效能
Flash/2GB DDR III RAM
溫度監測
軟體可讀取溫度監測
•RTC
時鐘支援
毫米(寬
英寸(寬
連接埠
SFP+ 10G + 40G/80G
連接埠
SFP+ 10G + 2
連接埠
10GBaseT + 40G/80G
連接埠
10GBaseT + 2
USB
連接埠
10 Gbps
40 Gbps QSFP
(TMP75)
連接埠用於
擴充槽用於
x 厚 x
高)。
x 厚 x
高)。
擴充模組
連接埠
40G QSFP + 40G/80G
擴充模組
連接埠
40G QSFP + 40G/80G
1G/10G
連接埠用於
SFP+、10G Base-T 和 QSFP+
CPU
收發機
40G
收發機
系統。
XLP308H/256 MB NOR
擴充
擴充
模組
58 硬體概覽
Page 61
熱插拔冗餘電源設備
電源管理的電流監測
風扇可拆卸,也可能損壞
標準
1U
機箱高
前板
圖表 PowerConnect 81xx 前板
1. PowerConnect 81xx 前板
前板包括:
24/48
USB 2.0
固定
10G Base-T 或 SFP+
管理連接埠
連接埠
註:系統、風扇和電源狀態指示燈的 LED 顯示在背面板上。
QSFP+ 連接埠
連接埠
硬體概覽 59
Page 62

四連接埠 SFP 上行連結固定連接埠

PC8164 PC8164F 模組具有兩個 QSFP 連接埠,個連接埠提供以 下功能:
四個具有四芯
一個支援
前板連接埠狀態
QSFP 連接可用於堆疊。在長達 100M 距離支援堆疊。
註:QSFP 模組僅可用於 PowerConnect 81xx 系列交換器。
/QBO
纜線的
CR4、SR4 和 LR4
LED
10G
連接埠
收發機的
40G
連接埠
擴充槽
80 Gbps 槽支援下列模組:
•SFP+
10G Base-T
•QSFP+
模組單獨出售
(四個
10G
連接埠)
(四個
10G
(可設定為兩個
連接埠)
40G
連接埠或多達八個
10G
連接埠)

UART 介面

UART(通用非同步收發機)連接埠根據工業標準 16550 UART 設備 模。UART 連接埠提供列通訊功能,可用於與該型或使用 RS-232 通 訊定的其他外部設備通訊。可以列連接埠接連接到交換器,並 可從通過提供的列纜線連接到此連接埠(RJ45 YOST 到內 DB-9 連接 器)的主控臺終端機來存取 CLI
UART 連接埠可單設定,並可作為從 1200 波特 4M 波特的 結運行。
UART 可使用以下選項程:
•5、6、7 或 8
•1、1.5 或 2
同位檢查選項
偶數/奇數同位檢查(如果啟用同位檢查選項)
固定同位檢查(如果啟用同位檢查選項)
字元位元
停止位元
60 硬體概覽
Page 63
預設為 9600 輸速8 個資料位元、無同1 停止位元、無 流控制

系統 LED

系統包含提供有關 PowerConnect 81xx 設備的系統、溫度、斷、風扇、 堆疊和定位器狀態的示的發光二極(LED)1 包含 LED
1. 系統的 LED 定義
功能 詳細說明 注釋
系統 LED
溫度 LED
診斷 LED
風扇 LED
堆疊 LED
穩定藍色
閃爍藍色
穩定紅色 錯誤
閃爍紅色 錯誤 (風扇故障、電源 設備故障)
熄滅
穩定琥珀色
熄滅
閃爍綠色 斷測試
穩定綠色 開且處於預期
穩定紅色 故障
穩定藍色 模式
穩定綠色 從模式
熄滅
-
正常運行
-
正在開機
-
嚴重系統
-
非嚴重系統
-
正常溫度
-
溫度過高
-
正常運行
-
正在運行診
-
風扇電源打
RPM
-
風扇出現
-
切換至堆疊
-
切換至堆疊
-
切換至獨立模式
在前板上
在背板上
a
在背板上
在背板上
在背板上
硬體概覽 61
Page 64
1. 系統的 LED 定義 (續)
911 15 1171375
owerConnect 8164
功能 詳細說明 注釋
定位 LED
閃爍藍色
-
定位器功能
在背板上
啟用
穩定藍色
-
定位器功能
禁用
a.
熱感器系統溫度閾值為
75C。
超出閾值時,溫度
LED
燈呈琥珀色亮起。
2. 連接埠 LED
Console
OOB
System LED
Locator
Stack
Temp
Dlag
FAN 1
1212121
2
62 硬體概覽
PowerConnect 8164
3
4
7
5
8
6
9
101112
15
13
14
17
16
20
18
23
21222319
24
Page 65
安裝

現場準備

安裝交換器之前,請確保選擇的安裝位置滿足以下現場要求:
空間
正面和背面有足夠空間供操作員進行操作。留出用於佈線、電源
連接以及通風的空間。
佈線
佈線應遠離電氣噪音干擾源,如無線電發射器、廣播放大器、電
線以及螢光照明裝置。
環境溫度
註:在 900 米(2955 英尺)以上,每升高 300 米(985 英尺)最高溫度下降
1C (1.8F)
相對濕度
每小時
交換器的運行環境溫度範圍為
運行相對濕度為
10%

打開交換器包裝

包裝箱物品
每台交換器的包裝時,請保其中包含以下物
一台
PowerConnect
一根
RJ45 至 DB-9
兩套滑軌套件(無需工具)
兩個
PSU
(單獨包裝)
兩根交流電源線(特定於國家/地區)
入門指南
安全和管制資訊
保證和支援資訊
軟體授權合約
8% 到 85%
交換器
內孔纜線
10 至 35C(50 至 95F
(非冷凝),最大濕度變化梯度為
)。
安裝 63
Page 66
打開包裝步驟
註:在打開交換器的包裝之前,先檢查包裝盒,如有任何損壞跡象,請立
即報告。
1
將包裝盒放在整潔平坦的表面上,然後剪斷固定包裝盒的所有包 裝帶。
2
打開包裝盒或取下包裝盒蓋。
3
從包裝盒中小心取出交換器,然後將其放在穩固整潔的表面上。
4
取出所有包裝材料。
5
檢查產品及附件是否出現損壞。

對交換器進行機架安裝

可將交換器放置於機架擱板上或接安裝到 19 寸寬、符合 EIA-310-E 要求的機中(四柱、兩柱或線形方法)。 Dell ReadyRails
1U 兩柱安裝。 ReadyRails 系統包含兩個單包裝的滑軌部件和加到交換器側面發運的滑軌。
警告: 這是簡要參考。請先閱讀 「安全、環境和管制」資訊手冊中的安全
說明,再開始操作。
註:本說明文件中的示意圖不用於表示特定交換器。
機架安裝安全說明
機架裝載超載或裝載不均勻可能導致擱板或機架出現故障,從而導致 損壞設備和可能造成人身傷害。先在一個固定位置固定機架,再開始 裝載。在機架底部開始安裝元件,然後逐個往上安裝到頂部。請勿超 過機架額定負載。
電源說明僅連接至設備上定的電源。在機架中安裝多個電子元件 時,確保元件額定功率不超過電路容量。超載電源和延長 火災危險
高的環境溫度如果安裝在封閉的機架部件中,機架環境的操作溫度 可能高於溫。請小心不超過交換器的最大環境溫度
更低的氣流將設備安裝在機架中,而不會影響操作設備所需的氣 流
系統可供
50
攝氏度。
64 安裝
Page 67
的接地保持的機架安裝設備接地。 請特別注意提供連接而不 是接連接至支電
不能將產品背面板朝向下的位置安裝。
使用電源線。
安裝 Dell ReadyRails 系統
提供 ReadyRails 安裝系統以輕鬆設定機便安裝交換器。 可使用 1U 工具的方或三種可能的 1U 需要工具的方兩柱平齊安裝、 柱居中安裝或四線行安裝)一安裝 ReadyRails 系統。
1U 免工具組態(四柱方孔或無螺紋圓孔)
1將 ReadyRails
端凸緣滑軌連接對準端垂直柱凸緣中。在
及其提取圖說明連接銷在方孔和無螺紋圓孔中是怎樣的。
1
3. 1U 免工具組態
凸緣吊耳面朝外,將一個滑軌放在左右垂直柱之間。將
圖3
中,項
2
將前端凸緣連接對準入垂直柱的孔中。 請參閱 圖3,
2。
3
第二個滑軌重複此
4
卸下每個滑軌,動每個凸緣吊耳上的閂鎖釋按鈕並拔出每個滑
參閱 圖3,項 3。
軌。
安裝 65
Page 68
兩柱平齊安裝組態
1
對於組態,必須從每個 圖4,頁碼
66
上的項 1。 用
ReadyRails
Torx
部件的前卸下件。參閱
螺絲刀卸下每個前端凸緣吊耳上的
顆螺釘(在滑軌交換器一卸下每個件。件供以後機 架需。不卸下後端凸緣鑄件。
4. 兩柱平齊安裝組態
2
使用兩顆使者提供的螺釘將一個滑軌連接到前柱凸緣 請參閱 圖4,
2。
3
正對垂直柱向前滑動柱塞支架,並使使者提供的兩顆螺釘柱塞 支架固定到垂直柱凸緣。
4
第二個滑軌重複此
參閱 圖4,項 3。
66 安裝
Page 69
兩柱居中安裝組態
1
後滑動柱塞支架,至其卡入到位,並使使者提供的兩顆螺釘 將支架固定至前柱凸緣。
5. 兩柱居中安裝組態
2
朝柱子滑動後端支架,並使用使用者提供的兩顆螺釘將其固定至柱子 凸緣
參閱 圖5,項 2。
3
第二個滑軌重複此
參閱 圖5,項 1。
安裝 67
Page 70
四柱線形組態
1
對於組態,必須
螺絲刀卸下每個前端凸緣吊耳上的兩顆螺釘並卸下每個件。
Torx
參閱
圖6
頁碼
2
對於每個滑軌,使使者提供的兩顆螺釘將前和後端凸緣連接至 柱凸緣各端
6. 四柱線形組態
ReadyRails
68
上的項 1。件供以後機架需
參閱 圖6,頁碼
部件的各端卸下凸緣吊耳鑄件。 用
68
上的項 2。
68 安裝
Page 71
安裝交換器
交換器可安裝在 1U 1U 雙柱平齊中)組態中。下面是 1U 組態的示1U 雙柱平齊中)組態,可以與四組態 的方式將交換器滑軌
1U 前機架安裝
必須設定連接交換器的滑軌
1
將交換器滑軌(內部機箱成員)連接至 顯示具有卡舌的前定位器的詳情
7. 連接交換器滑軌
PC81xx
交換器。7,項
1
2
安裝兩個交換器滑軌後,在前安裝到機架上的就緒滑軌
上將其成一行,並滑入交換器直至與機架前端平齊。在完全插
Rails)
前的
3
英寸,將使用滑軌使交換器避免意外滑出機架
並掉落
(Ready-
安裝 69
Page 72

啟動和設定交換器

以下流程圖概述了在開交換器包裝並安裝交換器後,用於進行初始 組態的步驟
8. 安裝和設定流程圖
連接電源和主
控台
開機
選擇選項 2
動功能表
( 特殊功能 )
重新動
進入動
功能表?
將程式從快閃記
憶體載入 RAM
進入
精靈?
手動初始設定
簡易設定精
靈設定
進階設定
70 啟動和設定交換器
Page 73

將交換器連接至終端機

完成所有部連接後,將終端機連接交換器以設定該交換器。
註:在繼續操作之前,請閱讀本產品的版本注釋。可以從 Dell 支援 Web
support.dell.com/support 下載版本注釋。
註:我們建議您從 Dell 支援網站 support.dell.com/support 獲取最新版本的使
用者說明文件。
要通過序列主控臺監測和設定交換器,請使用交換器背板的 RJ45 主控臺 連接埠,將交換器連接 VT100 終端機或在運行 VT100 終端機模擬軟 體的電腦。主控臺連接埠可用作資終端機設備 (DTE) 連接器。
要使用主控臺連接埠,需要以下設備:
VT100
軟體
一根序列纜線(附帶),帶有連接主控臺連接埠的 終端機的
要將終端機連接交換器主控臺連接埠,請行以下務:
1
序列纜線上的 或電相連。
2
照以下步驟設定終端機模軟體
a
b
c
d
e
f
3
將纜線上的
RJ45
容終端機,或一台序列連接埠運行
(如 Microsoft HyperTerminal)
DB-9
連接器。
DB-9
連接器運行
擇適當序列連接埠 (
速率設定為
格式設定為
將流控制設定為
9600
特。
8
料位元、1 個停止位以及無同位檢查。
none
(無)。
終端機模設定為 VT100
擇終端鍵作為箭頭鍵端鍵 (而不是
註:在 Microsoft Windows 2000 中使用超級終端機時,請確保已安裝
Windows 2000 Service Pack 2 或更高版本。使用 Windows 2000 Service Pack 2 可以確保箭頭鍵在超級終端機的 VT100 模擬中正常工作。有關 Windows 2000 Service Pack 的詳情,請存取 microsoft.com
Microsoft Windows
RJ45
連接器連接至位於交換器背部的
臺式機或可
VT100
COM 1
終端機模軟體的終端
)連接到主控臺。
Ctrl
確保此設定用於
)。
VT100
RJ45
終端機模
連接器和連接
PowerConnect 81xx
主控臺連接埠。
啟動和設定交換器 71
Page 74

開機交換器

開電源時,交換器將進行開機自測 (POST)POST 每次初始化交換 器時進行,用於檢硬體元件,以定交換器在完全開機之前是否完全正 。如 POST 檢測到嚴重問題,程式流就會停止。如 POST 功通過,將入一個有效的韌體到 RAM 中。POST 資訊示在終端機 上,用於指自測是否成功。開機過程大約運行 60 秒。
連接本終端機後,在 POST 第一部分完成後,可以調用 Boot(開機) 功能。從 Boot(開機)功能中,您可以行組態務,如將系統 設為出廠預設、啟動備映像或者恢復有關 Boot(開機)功功能的詳情,請參閱CLI 參考指南》

進行初始組態

初始組態步驟基於以下假設條件:
PowerConnect
相同。
PowerConnect
主控臺連接已建立並且 Dell 簡易安裝精靈 終端機或同等終端機設備的螢上。
通過主控臺連接埠行初始交換器組態。完成初始組態後,可以通過已連 接的主控臺連接埠或遠端連接管理交換器。
註:交換器未設定預設的使用者名稱、密碼和 IP 位址。
在設定交換器的初始組態之前,從網路管理員處獲得以下資訊:
要分配給帶外
OOB
OOB
要通過 Telnet(Telnet 用端)或 HTTP(Web 瀏覽器)來遠端管理交換 器,需要這設定。
面的
閘道
交換器前從進行過任何組態,其狀態收到時
交換器開機成功。
提示資訊顯示
(OOB)
IP
面進行設備管理的
子網路遮罩
IP
IP
VT100
72 啟動和設定交換器
Page 75
初始組態步驟
可以使用 Dell 簡易安裝精靈 CLI 來進行初始組態。交換器組態時,將自動啟動該靈。可以時通過輸入 [ctrl+z] 退出精靈,指定 的所有組態設定被丟棄,交換器將使用預設
註:如果不運行簡易安裝精靈或在 60 秒內沒有回應初始簡易安裝精靈提
示,交換器會進入 CLI 模式。
有關使用 CLI 進行初始組態的詳情,請參閱CLI 參考指南》使用 入門指南說明如何使用簡安裝靈來進行初始交換器組態。該靈設定
交換器的以下組態:
建立擁使者帳戶以及有效的密碼。在安裝過中, 該精靈將設定一個具有使者帳戶
啟用
CLI
登入
設定
設定 交換器不使用
OOB
SNMP
HTTP
面的
管理器在指定
SNMP
取,以便使驗證設定。
IP
IP
址要使用的
管理,則可以選擇跳過這一步。
SNMP
體字。如果
啟動和設定交換器 73
Page 76
示例工作階段
本節介紹了一個簡易安裝精靈工作階段。示工作階段將使用以下值:
註:當交換器從箱子中取出或設定為工廠預設值時,沒有使用者名稱、密
碼或 IP 位址。
•SNMP
OOB
註:在以下示例中,可能的使用者選項或預設值包括在 [ ] 中。如果未定義
以下示包含與使用上的輸入運行 Dell 簡易安裝精靈示例工作 階段相關的提示和列。
交換器完成 POST 並開機後,將示以下文資訊:
(Unit 1-Waiting to select management unit)>
Applying Global configuration, please wait ...
Welcome to Dell Easy Setup Wizard
The Setup Wizard guides you through the initial switch configuration, and gets you up and running as quickly as possible. You can skip the setup wizard, and enter CLI mode to manually configure the switch. You must respond to the next question to run the setup wizard within 60 seconds, otherwise the system will continue with normal operation using the default system configuration. Note: You can exit the setup wizard at any point by entering [ctrl+z].
啟用。
使者名稱 root 已,而且密碼 admin123 已輸入。在輸入密 碼時,精靈會顯示密碼
管理使 192.168.2.1 來分配
選項,按 <Enter> 鍵將接受預設值。幫助文字在括弧中。
IP
Would you like to run the setup wizard (you must answer this question within 60 seconds)? [Y/N] y
74 啟動和設定交換器
Page 77
First:
Do you want to select the operational mode as Simple Mode? [Y/N] y
Step 1:
The system is not setup for SNMP management by default. To manage the switch using SNMP (required for Dell Network Manager) you can
. Set up the initial SNMP version 2 account now.
. Return later and setup other SNMP accounts. (For
more information on setting up an SNMP version 1 or 3 account, see the user documentation).
Would you like to setup the SNMP management interface now? [Y/N] n
Step 2:
Now we need to setup your initial privilege (Level 15) user account. This account is used to login to the CLI and Web interface. You may setup other accounts and change privilege levels later. For more information on setting up user accounts and changing privilege levels, see the user documentation.
To setup a user account:
Please enter the user name. [root]:
Please enter the user password:
Please reenter the user password:
Step 3:
Next, IP addresses are setup on the OOB (Out-Of-Band) Interface and/or the VLAN1 routing interface.
You can use these IP addresses to access the CLI, Web interface, or SNMP interface of the switch.
啟動和設定交換器 75
Page 78
To access the switch through any Management Interface you can
. Setup the IP address for the Management Interface.
. Setup the default gateway if IP address is
manually configured on both routing and OOB interface.
Would you like to setup the Out-Of-Band interface now? [Y/N] y
Please enter the IP address of the device (A.B.C.D) or enter "DHCP" (without the quotes) to automatically request an IP address from the network DHCP server. [192.168.2.1]:
Please enter the IP subnet mask (A.B.C.D or /nn). [255.255.255.0]:
This is the configuration information that has been collected:
Operational Mode = Simple
User Account setup = root
Password = ********
Out-of-band IP address = 192.168.2.1 255.255.255.0
Final Step:
If the information is correct, please enter (Y) to save the configuration, and copy the settings to the start-up configuration file. If the information is incorrect, enter (N) to discard the configuration and restart the wizard: [Y/N] y
Thank you for using the Dell Easy Set up Wizard. You will now enter CLI mode.
Applying Interface configuration, please wait ...
console>
76 啟動和設定交換器
Page 79
接下來的步驟
完成本節所的初始組態後,您可以將任意前板交換器連接埠連接到生 網路以便進行內遠端管理。
指定 DHCP 來分 OOB 管理介 IP 址,該介面會從網路上的 DHCP 伺服器獲得 IP 位址。要現動態分 IP 位址,請使用主控臺 接埠連接來發出以下命令:
show ip interface out-of-band
要存取 Dell OpenManage Switch Administrator,請在 Web 瀏覽器 的欄位中輸入 OOB 管理介面 IP 址。要對 CLI 進行遠端管理存 取,請在 Telnet 或 SSH 用端中輸入 OOB 管理介 IP 址。或者,可繼續使用主控臺連接埠對交換器進行本機 CLI 存取。
您的 PowerConnect 81xx 交換器支援基本的交換功能,如 VLAN
802.1XRADIUS TACACS+ 請參閱簡單交換器模式:連接埠聚合器功能白皮書
將交換器設定為在通模式下工作,也能支援跨距樹狀目錄通訊 之類的功能,以及進 3 層功能(如動態路和多點送)。使用 基於 Web 的管理介面或 CLI 可設定您的網路需要的功能。 有關如何設定 交換器功能的資訊,請參閱User's Configuration Guide(使用者組態 指南)或CLI 參考指南》,這些資料可從以下支援站點獲取: support.dell.com/support
。 有關在簡單模式中支援的功能的詳情
啟動和設定交換器 77
Page 80
78 啟動和設定交換器
Page 81
Commutateur Dell
PowerConnect 81xx Series
Guide de mise en route
Modèle réglementaire : PC8132, PC8132F, PC8164, PC8164F
Page 82
Remarques
REMARQUE : Une REMARQUE indique des informations importantes qui peuvent
vous aider à mieux utiliser votre ordinateur.
PRÉCAUTION : Une PRECAUTION indique un risque potentiel d'endommagement
du matériel ou de pertes de données si les instructions ne sont pas suivies.
____________________
Les informations contenues dans ce document peuvent être modifiées sans préavis. © 2012 Dell Inc. tous droits réservés.
La reproduction de ce document de quelque manière que ce soit sans l'autorisation écrite de Dell Inc. est strictement interdite.
Marques utilisées dans ce document : Dell™, le logo DELL, PowerConnect™, et OpenManage™, ReadyRails™ et des marques déposées de Microsoft Corporation aux Etats-Unis et/ou dans d'autres pays.
Tous les autres noms de marques et marques commerciales utilisés dans ce document se rapportent aux sociétés propriétaires de ces marques et de ces noms ou à leurs produits. Dell Inc. décline tout intérêt propriétaire vis-à-vis des marques et des noms de marque autres que les siens.
Tor x ™
sont des marques commerciales de Dell Inc. Microsoft®, et Windows® sont
Modèle réglementaire PC8132, PC8132F, PC8164, PC8164F
Février 2012 N/P JHCTM Rév. A00
Page 83

Table des matières

1 Introduction . . . . . . . . . . . . . . . . . . . . . . . 83
Caractéristiques . . . . . . . . . . . . . . . . . . . . . 83
2 Présentation du matériel. . . . . . . . . . . . . 84
Panneau avant . . . . . . . . . . . . . . . . . . . . . . 86
Quatre ports SFP reliés en amont à des ports fixes
Logement d'extension
Interface UART
Voyants du système
. . . . . . . . . . . . . . . . . . 87
. . . . . . . . . . . . . . . . . . . . . . 87
. . . . . . . . . . . . . . . . . . . 88
. . . 86
3 Installation . . . . . . . . . . . . . . . . . . . . . . . 90
Préparation du site . . . . . . . . . . . . . . . . . . . 90
Déballage du commutateur
Contenu du carton
Etapes du déballage
Montage du commutateur en rack
Considérations pour la sécurité du montage
. . . . . . . . . . . . . . . . . . . . . . . 92
du rack
Installation du système ReadyRails de Dell
Installation du commutateur
. . . . . . . . . . . . . . . 90
. . . . . . . . . . . . . . . . . 90
. . . . . . . . . . . . . . . . 91
. . . . . . . . . . . 91
. . . . 92
. . . . . . . . . . . . 97
Table des matières 81
Page 84
4 Démarrage et configuration
du commutateur
Connexion du commutateur à un terminal . . . . . . . 99
. . . . . . . . . . . . . . . . . . . 98
Démarrage du commutateur
. . . . . . . . . . . . . . 100
Réalisation de la configuration initiale
Procédure de configuration initiale
Exemple de session
Prochaines étapes
. . . . . . . . . . . . . . . . 102
. . . . . . . . . . . . . . . . 107
. . . . . . . . 100
. . . . . . . . 101
82 Table des matières
Page 85

Introduction

Ce document contient des informations générales sur les commutateurs série Dell PowerConnect 81xx , ainsi que des informations relatives à l'installation et à la configuration initiale d'un commutateur. Pour obtenir des informations sur la configuration et le contrôle des fonctions du commutateur, reportez­vous au User's Configuration Guide (Guide de configuration), disponible sur le site du Support Dell à l'adresse support.dell.com/support et prenez connaissance des dernières mises à jour concernant la documentation et le micrologiciel.
Ce document contient les sections suivantes :
Présentation du matériel
Installation
Démarrage et configuration du commutateur

Caractéristiques

Les PowerConnect 8100 Series sont des commutateurs réseau sans­interruption hautement évolutifs pour une agrégation de site ou des déploiements 10 GbE de commutation de cœur. La famille des commutateurs de couche 3 offre une performance sans ralentissement de 10/40 GbE nécessaire pour alimenter les infrastructures d'entreprise, tout en autorisant une extensibilité et un fonctionnement 10 GbE de haute densité avec une gestion simplifiée.
Le PC 8100 Series offre une haute disponibilité et une forte redondance pour un petit groupe et le déploiement d'agrégation qui aide votre réseau à s'accroître pour un fonctionnement à 10 GbE de haute densité et jusqu'à 40 GbE pour le cœur Enterprise. La famille offre un empilage haute densité avec les ports 10 GbE ou 40 GbE, gérable comme une unité logique simple, comme pour la redondance avec les blocs d'alimentation, les ventilateurs et les images du micrologiciel. La gestion simplifiée comprend également une fonction de déploiement rapide USB afin d'expédier l'adressage réseau au démarrage, ainsi que l'installation de l'image du micrologiciel rationalisée sur l'intégralité de la pile de commutateurs. Les options de gestion flexible comprennent une implémentation CLI conforme aux normes de l'industrie, une gestion à distance à l'aide d'un serveur web intégré et une prise en charge des applications de gestion basées sur le SNMP comprenant le Dell OpenManage Network Manager.
Introduction 83
Page 86
La famille PC8100 comprend une prise en charge du réseau de stockage et une optimisation iSCSI. Pour simplifier la connectivité avec les baies Dell EqualLogic, la fonction iSCSI Auto-Configuration (Configuration automatique iSCSI) de tous les commutateurs 8100 Series détecte les baies et configure le commutateur pour une capacité optimale. Cette fonction est activée par défaut, rationalisant le processus à un simple branchement de câble. La connectivité avec les baies Dell Compellent est également simplifiée grâce à une configuration à commande unique.
Dell a conçu le Power Connect 8100 Series pour réaliser des économies d'énergie du câble d'alimentation aux ports, en commençant par les ports prenant en charge l'EEE pour réduire la consommation d'alimentation de port actif et passif de tous les ports. En plus des blocs d'alimentation redondants qui peuvent fonctionner efficacement dans tous les modes, la vitesse variable des ventilateurs réduit la consommation en ajustant leur vitesse à leur environnement via de multiples moniteurs de température. Enfin, la famille PC8100 comprend la garantie de durée de vie limitée de Dell avec le service de matériel de base (réparation ou remplacement) pour la vie.

Présentation du matériel

Cette section contient des informations sur les caractéristiques du périphérique et sur les configurations matérielles modulaires des commutateurs PowerConnect 81xx.
Les dimensions physiques du PowerConnect 81xx sont les suivantes :
440 x 460 x 44 mm (Largeur x Profondeur x Hauteur)
17,32 x 18,11 x 4,39 cm (Largeur x Profondeur x Hauteur)
Le PowerConnect 81xx possède un châssis avec quatre types de solutions et une largeur de bande de commutation de 640 Gbit/s et de 320 Gbit/s comme décrite ci-dessous :
1
PC8132F - 24 ports SFP+ 10G + module d'extension 40G/80G
2
PC8164F - 48 ports SFP+ 10G + 2 ports 40G QSFP + module d'extension 40G/80G
3
PC8132 - 24 ports 10GBaseT + module d'extension 40G/80G
4
PC8164 - 48 ports 10GBaseT + 2 ports 40G QSFP + module d'extension 40G/80G
84 Présentation du matériel
Page 87
Les logements du module peuvent être branchés dans trois types de modules :
•SFP+
10G Base-T
•QSFP+
Le système peut également fournir un port de console de type RJ45 pour une interface RS-232 et un port service Ethernet dédié pour les fonctions de gestion hors-bande.
Le PC81xx est équipé des fonctions suivantes :
Prise en charge d'un port USB
Quarante-huit ports 10 Gbit/s pour un émetteur-récepteur de 1G/10G
Deux ports QSFP 40 Gbit/s fixes pour un émetteur-récepteur de 40G
Un logement d'extension de 80 Gbit/s pour les modules SFP+, 10G Base-T et QSFP+
Un processeur à mémoire élevée avec une carte haute performance. XLP308H/256 Mo NOR Flash/2 Go DDR III RAM.
Surveillance de la température (TMP75)
Moniteur du logiciel de lecteur de la température
Prise en charge de l'horloge RTC
Bloc d'alimentation redondant connectable à chaud
Surveillance de la gestion d'alimentation
Le ventilateur est amovible et peut êre manié
Châssis 1U standard élevé
Présentation du matériel 85
Page 88

Panneau avant

L'image suivante illustre le panneau avant du PowerConnect 81xx :
Figure 1. PowerConnect 81xx Panneau avant
Le panneau avant comprend :
24/48 ports fixes 10G Base-T ou SFP+
Port de gestion
Port USB 2.0
REMARQUE : L’affichage des voyants System, fan et power status est situé sur le
panneau arrière.
Ports QSFP+

Quatre ports SFP reliés en amont à des ports fixes

Les modèles PC8164 et PC8164F possèdent deux ports QSFP fixes, chacun offrant les fonctions suivantes :
Quatre ports 10G avec un câble à quatre sortie/QBO
Un port 40G prenant en charge les émetteurs-récepteurs CR4, SR4 et LR4
Voyants d'état du port du panneau avant
Les connexions QSFP peuvent être utilisées pour l'empilage. L'empilage est pris en charge pour des distances pouvant atteindre 100 m.
REMARQUE : Les modules QSFP ne peuvent être utilisés que pour les
commutateurs série PowerConnect 81xx.
86 Présentation du matériel
Page 89

Logement d'extension

Le logement d'extension de 80 Gbit/s prend en charge les modules suivants :
SFP+ (4 ports 10G)
10G Base-T (4 ports 10G)
QSFP+ (peut être configuré avec deux ports 40G ou jusqu'à 8 ports 10G)
Les modules sont vendus séparément.

Interface UART

Le port UART (Universal Asynchronous Receiver Transmitter) a été modelé suite à la norme de l'industrie 16550 sur les périphériques UART Le port UART offre des capacités de communication en série, permettant une communication avec le modèle ou les périphériques externes utilisant le protocole RS-232. Un port série offre une connexion directe au commutateur et vous permet d'accéder à l'interface CLI depuis un terminal de console connecté au port via le câble série fourni (YOST RJ45 vers des connecteurs DB-9 femelles).
Le port UART est configurable séparément et peut être exécuté comme lien asynchrone de 1 200 bauds à 4 M de bauds.
L'interface UART peut être programmée avec les options suivantes :
caractères sur 5, 6, 7 ou 8 bits
1, 1,5 ou 2 bits d'arrêt
Option de parité
Parité régulière/inhabituelle (si l'option de parité est activée)
Parité permanente (si l'option de parité est activée)
Les valeurs par défaut sont 9 600 bauds, 8 bits de données, pas de parité, 1 bit d'arrêt, pas de contrôle de débit.
Présentation du matériel 87
Page 90

Voyants du système

Le système est équipé de diodes émettant de la lumière (DEL) qui donnent des indications sur l'état de System, Temp, Diag, Fan, Stack et Locator de l'unité PowerConnect 81xx. Tableau 1 contient les définitions des voyants d'état :
Tableau 1. Définitions des voyants du système
Fonction Description détaillée Commentaire
Voyant du système
Voyant Temp
Voyant Diag
Voyant Fan
• Bleu fixe : fonctionnement normal
• Bleu clignotant : amorçage
• Rouge fixe : erreur système critique
• Rouge clignotant : erreur système non critique (défaillance du ventilateur, défaillance du bloc d'alimentation)
• Arrêt : température normale
• Orange fixe : Température excessive
• Arrêt : fonctionnement normal
• Vert clignotant : test de diagnostic en cours d'exécution
• Vert fixe : ventilateur alimenté correctement et avec le nombre de tours par minute attendu
• Rouge fixe : ventilateur défectueux
a
Sur le panneau avant
Sur le panneau arrière
Sur le panneau arrière
Sur le panneau arrière
88 Présentation du matériel
Page 91
Tableau 1. Définitions des voyants du système (Suite)
911 15 1171375
owerConnect 8164
System LED
Fonction Description détaillée Commentaire
Voyant Stack
• Bleu fixe : passage au
Sur le panneau arrière
mode empilage
• Vert fixe : passage au mode esclave d'empilage
• Arrêt : passage au mode autonome
Voyant localisateur
• Bleu clignotant : la
Sur le panneau arrière
fonction localisateur est activée
• Bleu fixe : la fonction localisateur est désactivée
a. Le seuil de la température système des capteurs thermiques est de 75 °C. Lorsque ce seuil est dépassé, le voyant Temp s'allume en orange.
Figure 2. Voyants de port
FAN 1
Console
OOB
Locator
Stack
Temp
Dlag
1212121
2
PowerConnect 8164
3
4
7
5
8
6
91011
15
13
14
12
17
16
18
Présentation du matériel 89
23
21222319
20
24
Page 92

Installation

Préparation du site

Avant d'installer le ou les commutateurs, assurez-vous que l'endroit choisi pour l'installation répond aux conditions suivantes :
Dégagement
dégagés pour rester accessibles à un opérateur. Prévoyez un dégagement pour le câblage, les connexions électriques et la ventilation.
Câblage
bruit électrique, telles que les émetteurs radioélectriques, les amplificateurs de diffusion, les lignes électriques et les luminaires pour lampes fluorescentes.
Température ambiante
commutateur peut fonctionner est comprise entre 10 et 35°C.
REMARQUE : au dessus de 900 mètres, réduisez la température maximale d'un
degré Celsius (1°C) par 300 mètres.
Humidité relative
entre 8 % et 85 % (sans condensation) avec une augmentation maximale de 10 % par heure.

Déballage du commutateur

: l'avant et l'arrière de l'unité doivent être suffisamment
: les câbles doivent être acheminés de façon à éviter les sources de
: la température ambiante à laquelle le
: l'humidité relative de fonctionnement est comprise
Contenu du carton
Lors du déballage de chaque commutateur, vérifiez que le carton contient les éléments suivants :
Un commutateur PowerConnect
Un câble RJ45 vers un connecteur DB-9 femelle
Deux ensembles de kits de rail (aucun outil nécessaire)
Deux processeurs (emballés séparément)
Deux cordons d'alimentation (spécifiques aux pays/régions)
Le Guide de mise en route
90 Installation
Page 93
Les Informations sur la sécurité et les réglementations
Les Informations sur la garantie et le support technique
Le Contrat de licence du logiciel
Etapes du déballage
REMARQUE : Avant de déballer le commutateur, examinez le carton et signalez
immédiatement tout dommage apparent.
1
Posez le carton sur une surface plane et propre et coupez toutes les sangles d'attache.
2
Ouvrez le carton ou retirez le couvercle.
3
Retirez avec précaution le commutateur de son carton et posez-le sur une surface propre et stable.
4
Retirez tout le matériel d'emballage.
5
Vérifiez que le produit et ses accessoires ne sont pas endommagés.

Montage du commutateur en rack

Vous pouvez soit placer le commutateur dans l'armoire rack soit fixer le commutateur directement dans un rack compatible EIA-310-E de 48 cm (méthodes à quatre postes, deux postes ou filetée). Le système ReadyRails™ de Dell est fourni pour un rack frontal 1U et des installations à deux postes. Le système ReadyRails comprend deux assemblages sur rails emballés séparément et deux rails fournis fixés sur les côtés du commutateur.
AVERTISSEMENT : Il s'agit d'une référence concentrée. Veuillez lire les
consignes de sécurité dans votre livret de sécurité, environnemental et d'informations réglementaires avant de commencer.
REMARQUE : Les illustrations contenues dans ce document ne représentent pas
un commutateur spécifique.
Installation 91
Page 94
Considérations pour la sécurité du montage du rack
Chargement du rack : Le surchargement ou le chargement irrégulier du rack peut entraîner une défaillance de l'armoire ou du rack, pouvant endommager l'équipement et blesser l'utilisateur. Stabilisez les racks de manière permanente avant de commencer le chargement. Montez les composants en commençant par le bas du rack puis remontez vers le haut. Ne dépassez pas le taux de chargement du rack.
Considérations d’alimentation : Branchez uniquement la source d'alimentation spécifiée à l'unité. Lorsque des composants électriques multiples sont installés dans un rack, assurez-vous que le taux d'alimentation des composants n'excède pas les capacités du circuit. Les sources d'alimentation et les rallonges surchargées peuvent provoquer un incendie ou une électrocution.
Température ambiante élevée : Dans le cas d'une installation dans un rack fermé, la température de fonctionnement de l'environnement du rack peut être plus élevée que celle de la pièce ambiante. Faites attention à ne pas dépasser une température ambiante du commutateur de 50 degrés.
Ventilation réduite : Installez l'équipement dans le rack afin que la quantité de ventilation pour un fonctionnement en toute sécurité de l'équipement ne soit pas compromise.
Mise à la terre fiable : Assurez une mise à la terre fiable de l'équipement monté en rack. Faites particulièrement attention aux branchements d'alimentation autre que les connexions directes au circuit de dérivation, par exemple : utilisation de multiprises.
Le produit ne doit pas être monté avec le panneau arrière faisant face au sol.
Installation du système ReadyRails de Dell
Le système de montage en rack ReadyRails est fourni pour configurer facilement votre rack pour l'installation de votre commutateur. Le système ReadyRails peut être installé à l'aide d'une méthode sans outil 1U ou selon l'une des trois méthodes utilisant des outils possibles (montage encastré à deux postes, montage centré à deux postes ou filetage à quatre postes).
92 Installation
Page 95
Configuration 1U sans outil (Trou carré à quatre postes ou trou rond non-fileté)
1
Les crochets de la collerette ReadyRails vers l'extérieur, installez un rail entre les postes verticaux gauche et droit. Alignez puis placez les taquets du rail de la collerette arrière dans la collerette du poste vertical arrière. Dans la Figure 3, l'élément 1 et ses extractions illustrent la manière dont les taquets apparaissent dans les trous carrés ou les trous ronds non filetés.
Figure 3. Configuration 1U sans outil
2
Alignez et placez les taquets de la collerette avant dans les trous sur l'avant du poste vertical. Reportez-vous à la Figure 3, élément 2.
3
Répétez cette procédure pour le second rail.
4
Pour retirer chaque rail, poussez le bouton du loquet d'éjection de chaque collerette et désinstallez chaque rail. Reportez-vous à la Figure 3, élément 3.
Installation 93
Page 96
Configuration du montage intégré à deux postes
1
Pour cette configuration, les pièces moulées doivent être retirées de l'avant de chaque assemblage ReadyRails. Reportez-vous à la Figure 4, élément 1 à la page 94. Utilisez un tournevis Torx pour retirer les deux vis de chaque collerette avant (sur le côté du commutateur du rail) puis retirez chaque pièce moulée. Conservez les pièces moulées pour plus tard. Il n'est pas nécessaire de retirer les pièces moulées de la collerette arrière.
Figure 4. Configuration du montage intégré à deux postes
2
Fixez un rail sur la collerette du poste avant à l'aide des deux vis fournies par l'utilisateur. Reportez-vous à la Figure 4, élément 2.
94 Installation
Page 97
3
Faites glisser le support piston vers l'avant contre poste vertical et fixez-le à la collerette du poste à l'aide des deux vis fournies par l'utilisateur. Reportez-vous à la Figure 4, élément 3.
4
Répétez cette procédure pour le second rail.
Configuration du montage centré à deux postes
1
Faites glisser le support piston vers l'arrière jusqu'à ce qu'il s'enclenche fixez-le à la collerette du poste à l'aide des deux vis fournies par l'utilisateur. Reportez-vous à la Figure 5, élément 1.
Figure 5. Configuration du montage centré à deux postes
2
Faites glisser le support arrière vers l'avant du poste et fixez-le à la collerette du poste à l'aide des deux vis fournies par l'utilisateur. Reportezvous à la Figure 5, élément 2.
3
Répétez cette procédure pour le second rail.
Installation 95
Page 98
Configuration filetée à quatre postes
1
Pour cette configuration, les pièces moulées de la collerette doivent être retirées de chaque extrémité des assemblages ReadyRails. Utilisez un tournevis Torx pour retirer les deux vis de chaque collerette et retirer chaque pièce moulée. Reportez-vous à la Figure 6, élément 1 à la page 96. Conservez les pièces moulées pour plus tard.
2
Pour chaque rail, fixez les collerettes avant et arrière aux collerettes du poste à l'aide des deux vis fournies par l'utilisateur à chaque extrémité. Reportez-vous à la Figure 6, élément 2 à la page 96.
Figure 6. Configuration filetée à quatre postes
96 Installation
Page 99
Installation du commutateur
Le commutateur peut être monté dans une configuration rack avant 1U et dans les configurations à deux postes 1U (intégrée et centrée). Ci-dessous est un exemple d'une configuration de rack avant 1U. Pour les configurations à deux postes 1U (intégrée et centrée), vous pouvez faire glisser le commutateur dans les rails de la même manière que pour les configurations à quatre postes.
Installation du rack avant 1U
Les rails fixés au commutateur doivent être configurés.
Fixez les rails du commutateur (membres du châssis interne) au
1
commutateur PC81xx. Figure 7, l'élément 1 décrit les détails du picot de fixation avant avec la patte de verrouillage.
Figure 7. Fixation des rails du commutateur
2
Une fois les deux rails du commutateur installés, alignez-les avec les Ready-Rails précédemment fixés au rack et faites glisser le commutateur jusqu'à ce qu'il s'intègre à l'avant du rack. Environ 8 centimètres avant l'insertion totale, la fonction de verrouillage du rail s'active afin d'empêcher le commutateur de glisser en dehors du rack et de tomber par inadvertance.
Installation 97
Page 100

Démarrage et configuration du commutateur

L'organigramme ci-dessous présente un aperçu des étapes que vous devez effectuer lors de la configuration initiale après avoir déballé et monté le commutateur.
Figure 8. Organigramme des procédures d'installation et de configuration
Connexion de l'alimentation
et de la console
Mise sous tension
Oui
Choix de l'option 2
Menu d'amorçage
(fonctions spéciales)
Redémarrage
Entrer
dans le menu
d'amorçage ?
Non
Chargement du
programme de la
mémoire flash
vers la RAM
Entrer
dans l'Assistant ?
Non
Configuration
initiale manuelle
Configuration
avancée
98 Démarrage et configuration du commutateur
Oui
Assistant de
configuration Easy
Setup
Loading...