Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.
is strictly forbidden.
Trademarks used in this text: Dell™, the DELL logo, PowerConnect™, OpenManage™,
ReadyRails™ , and
trademarks of Microsoft Corporation in the United States and/or other countries.
Other trademarks and trade names may be used in this publication to refer to either the entities claiming
the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and
trade names other than its own.
Tor x™
are trademarks of Dell Inc. Microsoft®, Windows® are registered
Connecting a Switch to a Terminal . . . . . . . . . . . 20
Booting the Switch
. . . . . . . . . . . . . . . . . . . . 21
Performing the Initial Configuration
Initial Configuration Procedure
Example Session
Next Steps
. . . . . . . . . . . . . . . . . . 23
. . . . . . . . . . . . . . . . . . . . . 26
. . . . . . . . . . . 21
. . . . . . . . . . . 22
4Contents
Page 7
Introduction
This document provides basic information about the Dell PowerConnect
81xx series of switches, PC8132, PC8132F, PC8164, PC8164F, including how
to install a switch and perform the initial configuration. For information
about how to configure and monitor switch features, see the User’s Configuration Guide, which is available on the Dell Support website at
support.dell.com/support for the latest updates on documentation and
firmware.
This document contains the following sections:
•Hardware Overview
•Installation
•Starting and Configuring the Switch
Features
The PowerConnect 8100 Series are highly scalable, non-stop networking
switches for campus aggregation and core switching 10 GbE deployments.
The family of Layer 3 switches delivers 10/40 GbE wire-speed performance
required to power demanding Enterprise and business infrastructures, while
enabling scalability and high density 10 GbE operation with simplified
management.
PC8100 Series delivers high availability and redundancy for small core and
aggregation deployments that helps grow your network to high density 10
GbE operation and to 40 GbE for the Enterprise core. The family delivers
high density stacking with either 10GbE or 40GbE ports, manageable as a
single logical unit, as well as redundancy with power supplies, fans and
firmware images. Simplified management also includes a USB Rapid
Deployment feature to expedite network addressing at bootup, as well as
streamline firmware image installs across the entire stack. Flexible
management options include an industry-standard CLI, remote management
using the embedded web server, and support for SNMP-based management
applications including Dell OpenManage Network Manager.
The PC8100 family includes storage networking support and iSCSI
optimization. To simplify connectivity with Dell EqualLogic arrays, the iSCSI
Auto-Configuration feature in all 8100 Series switches automatically detects
the arrays and configures the switch for optimal throughput. This feature is
enabled by default, streamlining the process to just connecting a cable.
Connectivity with Dell Compellent arrays is also simplified with a single
command configuration.
Introduction5
Page 8
Dell designed the PowerConnect 8100 Series for energy savings from the
power cord to the ports, starting with EEE-capable ports to reduce active and
passive port power consumption for all ports. In addition to redundant power
supplies that can operate efficiently in all modes, variable speed fans reduce
consumption by adjusting their speed for their environment through multiple
temperature monitors. Lastly, the PC8100 family includes Dell’s Lifetime
Limited Warranty with Basic Hardware Service (repair or replacement) for
life.
Hardware Overview
This section contains information about device characteristics and modular
hardware configurations for the PowerConnect 81xx switches.
PowerConnect 81xx has the following physical dimensions:
•440 x 460 x 44 mm (W x D x H).
•17.32 x 18.11 x 1.73 inches (W x D x H).
PowerConnect 81xx has a chassis design with four kinds of solutions and 640
Gbps and 320 Gbps switching bandwidth as listed below:
1
PC8132F - 24 port SFP+ 10G + 40G/80G extension module
The module slots can plug in three kinds of modules:
•SFP+
•10G Base-T
•QSFP+
The system also provides one RS-232 interface RJ45 type console port and a
dedicated Ethernet service port for OOB management functions.
The PC81xx has the following features:
•Support one USB port
•Forty-eight 10 Gbps ports for 1G/10G transceiver
6Hardware Overview
Page 9
•Two fixed 40 Gbps QSFP ports for 40G transceiver
•One 80 Gbps expansion slots for SFP+, 10G Base-T and QSFP+ modules
•On board high performance CPU system with large memory.
XLP308H/256 MB NOR Flash/2GB DDR III RAM.
•Temperature monitoring (TMP75)
•Software readable thermal monitor
•RTC time clock support
•Hot plugging redundant power supply
•Current monitoring for Power management
•The fan is removable and can be managed
•Standard 1U chassis high
Front Panel
The following image shows the PowerConnect 81xx front panel:
Figure 1. PowerConnect 81xx Front Panel
The front panel includes:
•24/48 fixed 10G Base-T or SFP+ ports
•Management port
•USB 2.0 port
NOTE: LED display for System, fan and power status indicators are on the back
panel.
QSFP+ Ports
Hardware Overview7
Page 10
Quad-Port SFP Uplink Fixed Ports
The PC8164 and PC8164F models feature two fixed QSFP ports, each
providing the following features:
•Four 10G ports with quad-breakout/QBO cable
•One 40G port supporting CR4, SR4 and LR4 transceivers
•Front panel port status LEDs
The QSFP connections can be used for stacking. Stacking is supported at
distances of up to 100M.
NOTE: The QSFP modules can be used only for the PowerConnect 81xx-
series switches.
Expansion Slot
The 80 Gbps expansion slot supports the following modules:
•SFP+ (four 10G ports)
•10G Base-T (four 10G ports)
•QSFP+ (may be configured as two 40G ports or up to 8 10G ports)
The modules are sold separately.
UART Interface
The UART (Universal Asynchronous Receiver Transmitter) port is modeled
after the industry standard 16550 UART devices. The UART port provides
serial communication capabilities, which allows communication with the
model or other external devices using RS-232 protocol. A serial port provides
a direct connection to the switch and allows you to access the CLI from a
console terminal connected to the port through the provided serial cable
(with RJ45 YOST to female DB-9 connectors).
The UART port is separately configurable and can be run as an asynchronous
link from 1200 baud to 4M baud.
8Hardware Overview
Page 11
The UART interface can be programmed with the following options:
•5, 6, 7, or 8 character bits
•1, 1.5, or 2 stop bits
•Parity option
•Even/odd parity (if parity option is enabled)
•Sticky parity (if parity option is enabled)
The defaults are 9600 baud rate, 8 data bits, No Parity, 1 Stop Bit, No Flow
Control.
System LEDs
The system contains light emitting diodes (LEDs) that provide indications
about the System, Temp, Diag, Fan, Stack, and Locator status of the
PowerConnect 81xx unit. Table 1 contains the status LED definitions:
Table 1. LED Definitions for System
FeatureDetailed DescriptionComment
System LED
Temp LED
Diag LED
• Solid blue - Normal
operation
• Blinking blue - Booting
• Solid red - Critical
system error
• Blinking red - Noncritical system error (fan
fail, power supply fail)
• Off - Normal
temperature
• Solid amber - Overtemp
• Off - Normal operating
• Blinking green Diagnostic test running
On front panel
On back panel
a
On back panel
Hardware Overview9
Page 12
Table 1. LED Definitions for System (continued)
911151171375
owerConnect8164
FeatureDetailed DescriptionComment
Fan LED
• Solid green - Fan
On back panel
powered and at expected
RPM
• Solid red - Fan failed
Stack LED
• Solid blue - Switch in
On back panel
stacking mode
• Solid green - Switch in
stacking slave mode
• Off - Switch in stand
alone mode
Locator LED
• Blinking blue - Locator
On back panel
function is enabled
• Solid blue - Locator
function is disabled
a. The thermal sensors system temperature threshold is 75°C. When the threshold is exceeded, the
Temp LED lights up to Amber.
Figure 2. Port LEDs
FAN 1
Console
OOB
Locator
Stack
Temp
Dlag
System LED
1212121
2
10Hardware Overview
PowerConnect 8164
3
4
7
5
8
6
9
101112
15
13
14
17
16
20
18
23
21222319
24
Page 13
Installation
Site Preparation
Before installing the switch or switches, make sure that the chosen
installation location meets the following site requirements:
•
Clearance
Allow clearance for cabling, power connections, and ventilation.
•
Cabling
radio transmitters, broadcast amplifiers, power lines, and fluorescent
lighting fixtures.
•
Ambient Temperature
is 10° to 35ºC (50° to 95ºF).
NOTE: Decrease the maximum temperature by 1°C (1.8°F) per 300 m (985 ft.) above
900 m (2955 ft.).
•
Relative Humidity
(noncondensing) with a maximum humidity gradation of 10% per hour.
Unpacking the Switch
Package Contents
When unpacking each switch, make sure that the following items are
included:
•One PowerConnect switch
•One RJ45-to-DB-9 female cable
•Two sets of rail kits (no tools required)
•Two PSUs (packed separately)
•Two AC power cords (country/region specific)
•Getting Started Guide
•Safety and Regulatory Information
•Warranty and Support Information
•Software License Agreement
—There is adequate front and rear clearance for operator access.
—The cabling is routed to avoid sources of electrical noise such as
—The ambient switch operating temperature range
—The operating relative humidity is 8% to 85%
Installation11
Page 14
Unpacking Steps
NOTE: Before unpacking the switch, inspect the container and immediately report
any evidence of damage.
1
Place the container on a clean, flat surface and cut all straps securing the
container.
2
Open the container or remove the container top.
3
Carefully remove the switch from the container and place it on a secure
and clean surface.
4
Remove all packing material.
5
Inspect the product and accessories for damage.
Rack Mounting the Switch
You may either place the switch on the rack shelf or mount the switch directly
into a 19" wide, EIA-310-E compliant rack (four-post, two-post, or threaded
methods). The Dell ReadyRails™ system is provided for 1U front-rack, and
two-post installations. The ReadyRails system includes two separately
packaged rail assemblies and two rails that are shipped attached to the sides
of the switch.
WARNING: This is a condensed reference. Read the safety instructions in your
Safety, Environmental, and Regulatory information booklet before you begin.
NOTE: The illustrations in this document are not intended to represent a specific
switch.
Rack Mounting Safety Considerations
•Rack loading—Overloading or uneven loading of racks may result in shelf
or rack failure, causing damage to equipment and possible personal injury.
Stabilize racks in a permanent location before loading begins. Mount
components beginning at the bottom of the rack, then work to the top.
Do not exceed your rack load rating.
•Power considerations—Connect only to the power source specified on the
unit. When multiple electrical components are installed in a rack, ensure
that the total component power ratings do not exceed circuit capabilities.
Overloaded power sources and extension cords present fire and shock
hazards.
12Installation
Page 15
•Elevated ambient temperature—If installed in a closed rack assembly, the
operating temperature of the rack environment may be greater than room
ambient. Use care not to exceed the 50 degrees C maximum ambient
temperature of the switch.
•Reduced air flow—Install the equipment in the rack so that the amount of
airflow required for safe operation of the equipment is not compromised.
•Reliable earthing—Maintain reliable earthing of rack-mounted
equipment. Pay particular attention to supply connections other than
direct connections to the branch circuit, for example: use of power strips.
•Product should not be mounted with the rear panel facing in the
downward position.
Installing the Dell ReadyRails System
The ReadyRails rack mounting system is provided to easily configure your
rack for installation of your switch. The ReadyRails system can be installed
using the 1U tool-less method or one of three possible 1U tooled methods
(two-post flush mount, two-post center mount, or four-post threaded).
Installation13
Page 16
1U Tool-less Configuration (Four-post Square Hole or Unthreaded Round Hole)
1
With the ReadyRails flange ears facing outward, place one rail between the
left and right vertical posts. Align and seat the rear flange rail pegs in the
rear vertical post flange. In Figure 3, item 1 and its extractions illustrate
how the pegs appear in both the square and unthreaded round holes.
Figure 3. 1U Tool-less Configuration
2
Align and seat the front flange pegs in the holes on the front side of the
vertical post. See Figure 3, item 2.
3
Repeat this procedure for the second rail.
4
To remove each rail, pull on the latch release button on each flange ear and
unseat each rail. See Figure 3, item 3.
14Installation
Page 17
Two-post Flush-mount Configuration
1
For this configuration, the castings must be removed from the front side of
each ReadyRails assembly. See Figure 4, item 1 on page 15. Use a Torx
driver to remove the two screws from each front flange ear (on the switch
side of the rail) and remove each casting. Retain the castings for future
rack requirements. It is not necessary to remove the rear flange castings.
Figure 4. Two-post Flush-mount Configuration
2
Attach one rail to the front post flange with two user-supplied screws.
See Figure 4, item 2.
Installation15
Page 18
3
Slide the plunger bracket forward against the vertical post and secure the
plunger bracket to the post flange with two user-supplied screws.
See Figure 4, item 3.
4
Repeat this procedure for the second rail.
Two-post Center-mount Configuration
1
Slide the plunger bracket rearward until it clicks into place and secure the
bracket to the front post flange with two user-supplied screws.
See Figure 5, item 1.
Figure 5. Two-post Center-mount Configuration
2
Slide the back bracket towards the post and secure it to the post flange
with two user-supplied screws. See Figure 5, item 2.
3
Repeat this procedure for the second rail.
16Installation
Page 19
Four-post Threaded Configuration
1
For this configuration, the flange ear castings must be removed from each
end of the ReadyRails assemblies. Use a Torx driver to remove the two
screws from each flange ear and remove each casting. See Figure 6, item 1
on page 17. Retain the castings for future rack requirements.
2
For each rail, attach the front and rear flanges to the post flanges with two
user-supplied screws at each end. See Figure 6, item 2 on page 17.
Figure 6. Four-post Threaded Configuration
Installation17
Page 20
Installing the Switch
The switch may be mounted in the 1U front-rack and 1U two-post (flush and
center) configurations. The following is an example of 1U front-rack
configuration. The 1U two-post (flush and center) configurations, you can
slide the switch into the rails in the same manner as the four-post
configurations.
1U Front-rack Installation
The rails that are attached to the switch must be configured.
1
Attach the switch rails (inner chassis members) to the PC81xx switch.
Figure 7, item 1 shows the detail for the front standoff with locking tab.
Figure 7. Attaching the Switch Rails
2
After both switch rails are installed, line them up on Ready-Rails previously
mounted to the rack and slide the switch in until flush with front of rack.
About 3inches prior to full insertion, the rail locking feature will engage to
keep the switch from inadvertently sliding out of the rack and falling.
18Installation
Page 21
Starting and Configuring the Switch
The following flow chart provides an overview of the steps you use to perform
the initial configuration after the switch is unpacked and mounted.
Figure 8. Installation and Configuration Flow Chart
Connect Power
and Console
Power On
Choose Option 2
Boot Menu
(Special Functions)
Reboot
Ye s
Enter Boot
Menu?
No
Loading Program
from Flash to RAM
Enter
Wizard?
No
Manual Initial
Configuration
Advanced
Configuration
Ye s
Easy Setup Wizard
Configuration
Starting and Configuring the Switch19
Page 22
Connecting a Switch to a Terminal
After completing all external connections, connect a terminal to a switch to
configure the switch.
NOTE: Read the release notes for this product before proceeding. You can
download the release notes from the Dell Support website at
support.dell.com/support.
NOTE: We recommend that you obtain the most recent version of the user
documentation from the Dell Support website at support.dell.com/support.
To monitor and configure the switch via serial console, use the RJ45 console
port on the back panel of the switch to connect it to a VT100 terminal or to a
computer running VT100 terminal emulation software. The console port is
implemented as a data terminal equipment (DTE) connector.
The following equipment is required to use the console port:
•VT100-compatible terminal or a desktop or a portable computer with a
serial port running VT100 terminal emulation software,
HyperTerminal.
•A serial cable (provided) with a RJ45 connector for the console port and
DB-9 connector for the terminal.
Perform the following tasks to connect a terminal to the switch console port:
Connect the DB-9 connector on the serial cable to the terminal or
Configure the terminal emulation software as follows:
a
Select the appropriate serial port (for example, COM 1) to connect to
the console.
b
Set the data rate to 9600 baud.
c
Set the data format to 8 data bits, 1 stop bit, and no parity.
d
Set the flow control to none.
e
Set the terminal emulation mode to
f
Select Terminal keys for Function, Arrow, and Ctrl keys. Ensure that
VT100
.
the setting is for Terminal keys (not Microsoft Windows keys).
such as Microsoft
20Starting and Configuring the Switch
Page 23
NOTE: When using HyperTerminal with Microsoft Windows 2000, make sure
that you have Windows 2000 Service Pack 2 or later installed. With Windows
2000 Service Pack 2, the arrow keys function properly in HyperTerminal's
VT100 emulation. Go to microsoft.com for more information about
Windows 2000 service packs.
3
Connect the RJ45 connector on the cable directly to the PowerConnect
81xx RJ45 console port located on the back of the switch.
Booting the Switch
When the power is turned on, the switch goes through a power-on self-test
(POST). POST runs every time the switch is initialized and checks hardware
components to determine if the switch is fully operational before completely
booting. If POST detects a critical problem, the program flow stops. If POST
passes successfully, valid firmware is loaded into RAM. POST messages are
displayed on the terminal and indicate test success or failure. The boot
process runs for approximately 60 seconds.
With local terminal connected, you can invoke the Boot menu after the first
part of the POST is completed. From the Boot menu, you can perform
configuration tasks such as resetting the system to factory defaults, activating
the backup image, or recovering a password. For more information about the
Boot menu functions, see the CLI Reference Guide.
Performing the Initial Configuration
The initial configuration procedure is based on the following assumptions:
•The PowerConnect switch was never configured before and is in the same
state as when you received it.
•The PowerConnect switch booted successfully.
•The console connection was established, and the
prompt appears on the screen of a VT100 terminal or terminal equivalent.
The initial switch configuration is performed through the console port. After
the initial configuration, you can manage the switch from the alreadyconnected console port or through a remote connection.
NOTE: The switch is not configured with a default user name, password, or
IP address.
Starting and Configuring the Switch21
Dell Easy Setup Wizard
Page 24
Before setting up the initial configuration of the switch, obtain the following
information from your network administrator:
•The IP address to be assigned to the out-of-band (OOB) interface for
device management.
•The IP subnet mask for the OOB interface.
•The IP address of the OOB interface default gateway.
These settings are necessary to allow the remote management of the switch
through Telnet (Telnet client) or HTTP (Web browser).
Initial Configuration Procedure
You can perform the initial configuration by using the Dell Easy Setup
Wizard or by using the CLI. The wizard automatically starts when the switch
configuration file is empty. You can exit the wizard at any point by entering
[ctrl+z], but all configuration settings specified will be discarded, and the
switch will use the default values.
NOTE: If you do not run the Easy Setup Wizard or do not respond to the initial Easy
Setup Wizard prompt within 60 seconds, the switch enters CLI mode.
For more information about performing the initial configuration by using the
CLI, see the CLI Reference Guide. This Getting Started Guide shows how to
use the Easy Setup Wizard for initial switch configuration. The wizard sets up
the following configuration on the switch:
•Establishes the initial privileged user account with a valid password. The
wizard configures one privileged user account during the setup.
•Enables CLI login and HTTP access to use the local authentication setting
only.
•Sets up the IP address for the OOB interface.
•Sets up the SNMP community string to be used by the SNMP manager at
a given IP address. You may choose to skip this step if SNMP management
is not used for this switch.
22Starting and Configuring the Switch
Page 25
Example Session
This section describes an Easy Setup Wizard session. The following values are
used by the example session:
NOTE: There is no username, password, or ip address when the switch is unboxed
or set to factory defaults.
•SNMP is not enabled.
•The default user name,
entered. The Wizard does not display the password as it is entered.
•The OOB management interface uses
assignment.
NOTE: In the example below, the possible user options or default values are
enclosed in [ ]. If you press <Enter> with no options defined, the default value is
accepted. Help text is in parentheses.
The following example contains the sequence of prompts and responses
associated with running an example Dell Easy Setup Wizard session, using
the input values listed above.
After the switch completes the POST and is booted, the following text is
displayed:
(Unit 1-Waiting to select management unit)>
Applying Global configuration, please wait ...
Welcome to Dell Easy Setup Wizard
root
, is accepted and a password of
192.168.2.1
admin123
for IP address
is
The Setup Wizard guides you through the initial switch
configuration, and gets you up and running as quickly
as possible. You can skip the setup wizard, and enter
CLI mode to manually configure the switch. You must
respond to the next question to run the setup wizard
within 60 seconds, otherwise the system will continue
with normal operation using the default system
configuration. Note: You can exit the setup wizard at
any point by entering [ctrl+z].
Would you like to run the setup wizard (you must
answer this question within 60 seconds)? [Y/N] y
Starting and Configuring the Switch23
Page 26
First:
Do you want to select the operational mode as Simple
Mode? [Y/N] y
Step 1:
The system is not setup for SNMP management by
default. To manage the switch using SNMP (required for
Dell Network Manager) you can
. Set up the initial SNMP version 2 account now.
. Return later and setup other SNMP accounts. (For
more information on setting up an SNMP version 1
or 3 account, see the user documentation).
Would you like to setup the SNMP management interface
now? [Y/N] n
Step 2:
Now we need to setup your initial privilege (Level 15)
user account. This account is used to login to the CLI
and Web interface. You may setup other accounts and
change privilege levels later. For more information on
setting up user accounts and changing privilege
levels, see the user documentation.
To setup a user account:
Please enter the user name. [root]:
Please enter the user password:
Please reenter the user password:
Step 3:
Next, IP addresses are setup on the OOB (Out-Of-Band)
Interface and/or the VLAN1 routing interface.
You can use these IP addresses to access the CLI, Web
interface, or SNMP interface of the switch.
To access the switch through any Management Interface
you can
24Starting and Configuring the Switch
Page 27
. Setup the IP address for the Management Interface.
. Setup the default gateway if IP address is
manually configured on both routing and OOB
interface.
Would you like to setup the Out-Of-Band interface now?
[Y/N] y
Please enter the IP address of the device (A.B.C.D) or
enter "DHCP" (without the quotes) to automatically
request an IP address from the network DHCP server.
[192.168.2.1]:
Please enter the IP subnet mask (A.B.C.D or /nn).
[255.255.255.0]:
This is the configuration information that has been
collected:
Operational Mode = Simple
User Account setup = root
Password = ********
Out-of-band IP address = 192.168.2.1 255.255.255.0
Final Step:
If the information is correct, please enter (Y) to
save the configuration, and copy the settings to the
start-up configuration file. If the information is
incorrect, enter (N) to discard the configuration and
restart the wizard: [Y/N] y
Thank you for using the Dell Easy Set up Wizard. You
will now enter CLI mode.
Applying Interface configuration, please wait ...
console>
Starting and Configuring the Switch25
Page 28
Next Steps
After completing the initial configuration described in this section, you can
connect any of the front-panel switch ports to your production network for
in-band remote management.
If you specified DHCP for the OOB management interface IP address, the
interface will acquire its IP address from a DHCP server on the network. To
discover the dynamically-assigned IP address, use the console port connection
to issue the following command:
show ip interface out-of-band.
To access the Dell OpenManage Switch Administrator interface, enter the
OOB management interface IP address into the address field of a Web
browser. For remote management access to the CLI, enter the OOB
management interface IP address into a Telnet or SSH client. Alternatively,
you can continue to use the console port for local CLI access to the switch.
Your PowerConnect 81xx switch supports basic switching features such as
VLANs, 802.1X, RADIUS and TACACS+. For more information on the
features supported in Simple mode, see Simple Switch Mode: Port Aggregator Feature White Paper.
If the switch is configured to operate in Normal mode, it can also support
features such as spanning tree protocol, as well as advanced Layer 3 features
such as dynamic routing and multicast. Use the web-based management
interface or the CLI to configure the features your network requires. For
information about how to configure the switch features, see the User’s Configuration Guide or CLI Reference Guide available on the support site
support.dell.com/support.
The Setup Wizard guides you through the initial switch
configuration, and gets you up and running as quickly
as possible. You can skip the setup wizard, and enter
CLI mode to manually configure the switch. You must
respond to the next question to run the setup wizard
within 60 seconds, otherwise the system will continue
with normal operation using the default system
configuration. Note: You can exit the setup wizard at
any point by entering [ctrl+z].
未启用。
SNMP
默认用户名
已接受,而且密码
root
admin123
已输入。在输入密码
时,向导不会显示密码。
管理接口使用
OOB
项,按 <Enter> 键将接受默认值。帮助文本在括号中。
192.168.2.1
来分配
IP
地址。
Dell Easy Setup Wizard
简易安装向导)示例会话相关的提示序列和响应。
POST
并引导后,将显示以下文本信息:
Would you like to run the setup wizard (you must
answer this question within 60 seconds)? [Y/N] y
48启动和配置交换机
Page 51
First:
Do you want to select the operational mode as Simple
Mode? [Y/N] y
Step 1:
The system is not setup for SNMP management by
default. To manage the switch using SNMP (required for
Dell Network Manager) you can
. Set up the initial SNMP version 2 account now.
. Return later and setup other SNMP accounts. (For
more information on setting up an SNMP version 1
or 3 account, see the user documentation).
Would you like to setup the SNMP management interface
now? [Y/N] n
Step 2:
Now we need to setup your initial privilege (Level 15)
user account. This account is used to login to the CLI
and Web interface. You may setup other accounts and
change privilege levels later. For more information on
setting up user accounts and changing privilege
levels, see the user documentation.
To setup a user account:
Please enter the user name. [root]:
Please enter the user password:
Please reenter the user password:
Step 3:
Next, IP addresses are setup on the OOB (Out-Of-Band)
Interface and/or the VLAN1 routing interface.
You can use these IP addresses to access the CLI, Web
interface, or SNMP interface of the switch.
To access the switch through any Management Interface
you can
启动和配置交换机49
Page 52
. Setup the IP address for the Management Interface.
. Setup the default gateway if IP address is
manually configured on both routing and OOB
interface.
Would you like to setup the Out-Of-Band interface now?
[Y/N] y
Please enter the IP address of the device (A.B.C.D) or
enter "DHCP" (without the quotes) to automatically
request an IP address from the network DHCP server.
[192.168.2.1]:
Please enter the IP subnet mask (A.B.C.D or /nn).
[255.255.255.0]:
This is the configuration information that has been
collected:
Operational Mode = Simple
User Account setup = root
Password = ********
Out-of-band IP address = 192.168.2.1 255.255.255.0
Final Step:
If the information is correct, please enter (Y) to
save the configuration, and copy the settings to the
start-up configuration file. If the information is
incorrect, enter (N) to discard the configuration and
restart the wizard: [Y/N] y
Thank you for using the Dell Easy Set up Wizard. You
will now enter CLI mode.
The Setup Wizard guides you through the initial switch
configuration, and gets you up and running as quickly
as possible. You can skip the setup wizard, and enter
CLI mode to manually configure the switch. You must
respond to the next question to run the setup wizard
within 60 seconds, otherwise the system will continue
with normal operation using the default system
configuration. Note: You can exit the setup wizard at
any point by entering [ctrl+z].
Would you like to run the setup wizard (you must
answer this question within 60 seconds)? [Y/N] y
74啟動和設定交換器
Page 77
First:
Do you want to select the operational mode as Simple
Mode? [Y/N] y
Step 1:
The system is not setup for SNMP management by
default. To manage the switch using SNMP (required for
Dell Network Manager) you can
. Set up the initial SNMP version 2 account now.
. Return later and setup other SNMP accounts. (For
more information on setting up an SNMP version 1
or 3 account, see the user documentation).
Would you like to setup the SNMP management interface
now? [Y/N] n
Step 2:
Now we need to setup your initial privilege (Level 15)
user account. This account is used to login to the CLI
and Web interface. You may setup other accounts and
change privilege levels later. For more information on
setting up user accounts and changing privilege
levels, see the user documentation.
To setup a user account:
Please enter the user name. [root]:
Please enter the user password:
Please reenter the user password:
Step 3:
Next, IP addresses are setup on the OOB (Out-Of-Band)
Interface and/or the VLAN1 routing interface.
You can use these IP addresses to access the CLI, Web
interface, or SNMP interface of the switch.
啟動和設定交換器75
Page 78
To access the switch through any Management Interface
you can
. Setup the IP address for the Management Interface.
. Setup the default gateway if IP address is
manually configured on both routing and OOB
interface.
Would you like to setup the Out-Of-Band interface now?
[Y/N] y
Please enter the IP address of the device (A.B.C.D) or
enter "DHCP" (without the quotes) to automatically
request an IP address from the network DHCP server.
[192.168.2.1]:
Please enter the IP subnet mask (A.B.C.D or /nn).
[255.255.255.0]:
This is the configuration information that has been
collected:
Operational Mode = Simple
User Account setup = root
Password = ********
Out-of-band IP address = 192.168.2.1 255.255.255.0
Final Step:
If the information is correct, please enter (Y) to
save the configuration, and copy the settings to the
start-up configuration file. If the information is
incorrect, enter (N) to discard the configuration and
restart the wizard: [Y/N] y
Thank you for using the Dell Easy Set up Wizard. You
will now enter CLI mode.
Applying Interface configuration, please wait ...
console>
76啟動和設定交換器
Page 79
接下來的步驟
完成本節所述的初始組態後,您可以將任意前板交換器連接埠連接到生產
網路以便進行帶內遠端管理。
如果指定 DHCP 來分配 OOB 管理介面 IP 位址,則該介面會從網路上的
DHCP 伺服器獲得 IP 位址。要發現動態分配的 IP 位址,請使用主控臺連
接埠連接來發出以下命令:
show ip interface out-of-band。
要存取 Dell OpenManage Switch Administrator 介面,請在 Web 瀏覽器
的位址欄位中輸入 OOB 管理介面 IP 位址。要對 CLI 進行遠端管理存
取,請在 Telnet 或 SSH 用戶端中輸入 OOB 管理介面 IP 位址。或者,可
以繼續使用主控臺連接埠對交換器進行本機 CLI 存取。
La reproduction de ce document de quelque manière que ce soit sans l'autorisation écrite de Dell Inc.
est strictement interdite.
Marques utilisées dans ce document : Dell™, le logo DELL, PowerConnect™, et OpenManage™,
ReadyRails™ et
des marques déposées de Microsoft Corporation aux Etats-Unis et/ou dans d'autres pays.
Tous les autres noms de marques et marques commerciales utilisés dans ce document se rapportent
aux sociétés propriétaires de ces marques et de ces noms ou à leurs produits. Dell Inc. décline tout
intérêt propriétaire vis-à-vis des marques et des noms de marque autres que les siens.
Tor x ™
sont des marques commerciales de Dell Inc. Microsoft®, et Windows® sont
Connexion du commutateur à un terminal . . . . . . . 99
. . . . . . . . . . . . . . . . . . . 98
Démarrage du commutateur
. . . . . . . . . . . . . . 100
Réalisation de la configuration initiale
Procédure de configuration initiale
Exemple de session
Prochaines étapes
. . . . . . . . . . . . . . . . 102
. . . . . . . . . . . . . . . . 107
. . . . . . . . 100
. . . . . . . . 101
82Table des matières
Page 85
Introduction
Ce document contient des informations générales sur les commutateurs série
Dell PowerConnect 81xx , ainsi que des informations relatives à l'installation
et à la configuration initiale d'un commutateur. Pour obtenir des informations
sur la configuration et le contrôle des fonctions du commutateur, reportezvous au User's Configuration Guide (Guide de configuration), disponible sur
le site du Support Dell à l'adresse support.dell.com/support et prenez
connaissance des dernières mises à jour concernant la documentation et le
micrologiciel.
Ce document contient les sections suivantes :
•Présentation du matériel
•Installation
•Démarrage et configuration du commutateur
Caractéristiques
Les PowerConnect 8100 Series sont des commutateurs réseau sansinterruption hautement évolutifs pour une agrégation de site ou des
déploiements 10 GbE de commutation de cœur. La famille des
commutateurs de couche 3 offre une performance sans ralentissement de
10/40 GbE nécessaire pour alimenter les infrastructures d'entreprise, tout en
autorisant une extensibilité et un fonctionnement 10 GbE de haute densité
avec une gestion simplifiée.
Le PC 8100 Series offre une haute disponibilité et une forte redondance pour
un petit groupe et le déploiement d'agrégation qui aide votre réseau à
s'accroître pour un fonctionnement à 10 GbE de haute densité et jusqu'à
40 GbE pour le cœur Enterprise. La famille offre un empilage haute densité
avec les ports 10 GbE ou 40 GbE, gérable comme une unité logique simple,
comme pour la redondance avec les blocs d'alimentation, les ventilateurs et
les images du micrologiciel. La gestion simplifiée comprend également une
fonction de déploiement rapide USB afin d'expédier l'adressage réseau au
démarrage, ainsi que l'installation de l'image du micrologiciel rationalisée sur
l'intégralité de la pile de commutateurs. Les options de gestion flexible
comprennent une implémentation CLI conforme aux normes de l'industrie,
une gestion à distance à l'aide d'un serveur web intégré et une prise en charge
des applications de gestion basées sur le SNMP comprenant le Dell
OpenManage Network Manager.
Introduction83
Page 86
La famille PC8100 comprend une prise en charge du réseau de stockage et
une optimisation iSCSI. Pour simplifier la connectivité avec les baies Dell
EqualLogic, la fonction iSCSI Auto-Configuration (Configuration
automatique iSCSI) de tous les commutateurs 8100 Series détecte les baies
et configure le commutateur pour une capacité optimale. Cette fonction est
activée par défaut, rationalisant le processus à un simple branchement de
câble. La connectivité avec les baies Dell Compellent est également
simplifiée grâce à une configuration à commande unique.
Dell a conçu le Power Connect 8100 Series pour réaliser des économies
d'énergie du câble d'alimentation aux ports, en commençant par les ports
prenant en charge l'EEE pour réduire la consommation d'alimentation de
port actif et passif de tous les ports. En plus des blocs d'alimentation
redondants qui peuvent fonctionner efficacement dans tous les modes, la
vitesse variable des ventilateurs réduit la consommation en ajustant leur
vitesse à leur environnement via de multiples moniteurs de température.
Enfin, la famille PC8100 comprend la garantie de durée de vie limitée de Dell
avec le service de matériel de base (réparation ou remplacement) pour la vie.
Présentation du matériel
Cette section contient des informations sur les caractéristiques du
périphérique et sur les configurations matérielles modulaires des
commutateurs PowerConnect 81xx.
Les dimensions physiques du PowerConnect 81xx sont les suivantes :
•440 x 460 x 44 mm (Largeur x Profondeur x Hauteur)
•17,32 x 18,11 x 4,39 cm (Largeur x Profondeur x Hauteur)
Le PowerConnect 81xx possède un châssis avec quatre types de solutions et
une largeur de bande de commutation de 640 Gbit/s et de 320 Gbit/s comme
décrite ci-dessous :
Les logements du module peuvent être branchés dans trois types de modules :
•SFP+
•10G Base-T
•QSFP+
Le système peut également fournir un port de console de type RJ45 pour une
interface RS-232 et un port service Ethernet dédié pour les fonctions de
gestion hors-bande.
Le PC81xx est équipé des fonctions suivantes :
•Prise en charge d'un port USB
•Quarante-huit ports 10 Gbit/s pour un émetteur-récepteur de 1G/10G
•Deux ports QSFP 40 Gbit/s fixes pour un émetteur-récepteur de 40G
•Un logement d'extension de 80 Gbit/s pour les modules SFP+, 10G Base-T
et QSFP+
•Un processeur à mémoire élevée avec une carte haute performance.
XLP308H/256 Mo NOR Flash/2 Go DDR III RAM.
•Surveillance de la température (TMP75)
•Moniteur du logiciel de lecteur de la température
•Prise en charge de l'horloge RTC
•Bloc d'alimentation redondant connectable à chaud
•Surveillance de la gestion d'alimentation
•Le ventilateur est amovible et peut êre manié
•Châssis 1U standard élevé
Présentation du matériel85
Page 88
Panneau avant
L'image suivante illustre le panneau avant du PowerConnect 81xx :
Figure 1. PowerConnect 81xx Panneau avant
Le panneau avant comprend :
•24/48 ports fixes 10G Base-T ou SFP+
•Port de gestion
•Port USB 2.0
REMARQUE : L’affichage des voyants System, fan et power status est situé sur le
panneau arrière.
Ports QSFP+
Quatre ports SFP reliés en amont à des ports fixes
Les modèles PC8164 et PC8164F possèdent deux ports QSFP fixes, chacun
offrant les fonctions suivantes :
•Quatre ports 10G avec un câble à quatre sortie/QBO
•Un port 40G prenant en charge les émetteurs-récepteurs CR4, SR4 et LR4
•Voyants d'état du port du panneau avant
Les connexions QSFP peuvent être utilisées pour l'empilage. L'empilage est
pris en charge pour des distances pouvant atteindre 100 m.
REMARQUE : Les modules QSFP ne peuvent être utilisés que pour les
commutateurs série PowerConnect 81xx.
86Présentation du matériel
Page 89
Logement d'extension
Le logement d'extension de 80 Gbit/s prend en charge les modules suivants :
•SFP+ (4 ports 10G)
•10G Base-T (4 ports 10G)
•QSFP+ (peut être configuré avec deux ports 40G ou jusqu'à 8 ports 10G)
Les modules sont vendus séparément.
Interface UART
Le port UART (Universal Asynchronous Receiver Transmitter) a été modelé
suite à la norme de l'industrie 16550 sur les périphériques UART Le port
UART offre des capacités de communication en série, permettant une
communication avec le modèle ou les périphériques externes utilisant le
protocole RS-232. Un port série offre une connexion directe au commutateur
et vous permet d'accéder à l'interface CLI depuis un terminal de console
connecté au port via le câble série fourni (YOST RJ45 vers des connecteurs
DB-9 femelles).
Le port UART est configurable séparément et peut être exécuté comme lien
asynchrone de 1 200 bauds à 4 M de bauds.
L'interface UART peut être programmée avec les options suivantes :
•caractères sur 5, 6, 7 ou 8 bits
•1, 1,5 ou 2 bits d'arrêt
•Option de parité
•Parité régulière/inhabituelle (si l'option de parité est activée)
•Parité permanente (si l'option de parité est activée)
Les valeurs par défaut sont 9 600 bauds, 8 bits de données, pas de parité, 1 bit
d'arrêt, pas de contrôle de débit.
Présentation du matériel87
Page 90
Voyants du système
Le système est équipé de diodes émettant de la lumière (DEL) qui donnent
des indications sur l'état de System, Temp, Diag, Fan, Stack et Locator de
l'unité PowerConnect 81xx. Tableau 1 contient les définitions des voyants
d'état :
Tableau 1. Définitions des voyants du système
FonctionDescription détailléeCommentaire
Voyant du système
Voyant Temp
Voyant Diag
Voyant Fan
• Bleu fixe :
fonctionnement normal
• Bleu clignotant :
amorçage
• Rouge fixe : erreur
système critique
• Rouge clignotant : erreur
système non critique
(défaillance du
ventilateur, défaillance
du bloc d'alimentation)
• Arrêt : température
normale
• Orange fixe :
Température excessive
• Arrêt : fonctionnement
normal
• Vert clignotant : test de
diagnostic en cours
d'exécution
• Vert fixe : ventilateur
alimenté correctement et
avec le nombre de tours
par minute attendu
• Rouge fixe : ventilateur
défectueux
a
Sur le panneau avant
Sur le panneau arrière
Sur le panneau arrière
Sur le panneau arrière
88Présentation du matériel
Page 91
Tableau 1. Définitions des voyants du système (Suite)
911151171375
owerConnect8164
System LED
FonctionDescription détailléeCommentaire
Voyant Stack
• Bleu fixe : passage au
Sur le panneau arrière
mode empilage
• Vert fixe : passage au
mode esclave d'empilage
• Arrêt : passage au mode
autonome
Voyant localisateur
• Bleu clignotant : la
Sur le panneau arrière
fonction localisateur est
activée
• Bleu fixe : la fonction
localisateur est
désactivée
a. Le seuil de la température système des capteurs thermiques est de 75 °C. Lorsque ce seuil est
dépassé, le voyant Temp s'allume en orange.
Figure 2. Voyants de port
FAN 1
Console
OOB
Locator
Stack
Temp
Dlag
1212121
2
PowerConnect 8164
3
4
7
5
8
6
91011
15
13
14
12
17
16
18
Présentation du matériel89
23
21222319
20
24
Page 92
Installation
Préparation du site
Avant d'installer le ou les commutateurs, assurez-vous que l'endroit choisi
pour l'installation répond aux conditions suivantes :
•
Dégagement
dégagés pour rester accessibles à un opérateur. Prévoyez un dégagement
pour le câblage, les connexions électriques et la ventilation.
•
Câblage
bruit électrique, telles que les émetteurs radioélectriques, les
amplificateurs de diffusion, les lignes électriques et les luminaires pour
lampes fluorescentes.
•
Température ambiante
commutateur peut fonctionner est comprise entre 10 et 35°C.
REMARQUE : au dessus de 900 mètres, réduisez la température maximale d'un
degré Celsius (1°C) par 300 mètres.
•
Humidité relative
entre 8 % et 85 % (sans condensation) avec une augmentation maximale
de 10 % par heure.
Déballage du commutateur
: l'avant et l'arrière de l'unité doivent être suffisamment
: les câbles doivent être acheminés de façon à éviter les sources de
: la température ambiante à laquelle le
: l'humidité relative de fonctionnement est comprise
Contenu du carton
Lors du déballage de chaque commutateur, vérifiez que le carton contient les
éléments suivants :
•Un commutateur PowerConnect
•Un câble RJ45 vers un connecteur DB-9 femelle
•Deux ensembles de kits de rail (aucun outil nécessaire)
•Deux processeurs (emballés séparément)
•Deux cordons d'alimentation (spécifiques aux pays/régions)
•Le Guide de mise en route
90Installation
Page 93
•Les Informations sur la sécurité et les réglementations
•Les Informations sur la garantie et le support technique
•Le Contrat de licence du logiciel
Etapes du déballage
REMARQUE : Avant de déballer le commutateur, examinez le carton et signalez
immédiatement tout dommage apparent.
1
Posez le carton sur une surface plane et propre et coupez toutes les sangles
d'attache.
2
Ouvrez le carton ou retirez le couvercle.
3
Retirez avec précaution le commutateur de son carton et posez-le sur une
surface propre et stable.
4
Retirez tout le matériel d'emballage.
5
Vérifiez que le produit et ses accessoires ne sont pas endommagés.
Montage du commutateur en rack
Vous pouvez soit placer le commutateur dans l'armoire rack soit fixer le
commutateur directement dans un rack compatible EIA-310-E de 48 cm
(méthodes à quatre postes, deux postes ou filetée). Le système ReadyRails™
de Dell est fourni pour un rack frontal 1U et des installations à deux postes.
Le système ReadyRails comprend deux assemblages sur rails emballés
séparément et deux rails fournis fixés sur les côtés du commutateur.
AVERTISSEMENT : Il s'agit d'une référence concentrée. Veuillez lire les
consignes de sécurité dans votre livret de sécurité, environnemental et
d'informations réglementaires avant de commencer.
REMARQUE : Les illustrations contenues dans ce document ne représentent pas
un commutateur spécifique.
Installation91
Page 94
Considérations pour la sécurité du montage du rack
•Chargement du rack : Le surchargement ou le chargement irrégulier du
rack peut entraîner une défaillance de l'armoire ou du rack, pouvant
endommager l'équipement et blesser l'utilisateur. Stabilisez les racks de
manière permanente avant de commencer le chargement. Montez les
composants en commençant par le bas du rack puis remontez vers le haut.
Ne dépassez pas le taux de chargement du rack.
•Considérations d’alimentation : Branchez uniquement la source
d'alimentation spécifiée à l'unité. Lorsque des composants électriques
multiples sont installés dans un rack, assurez-vous que le taux
d'alimentation des composants n'excède pas les capacités du circuit. Les
sources d'alimentation et les rallonges surchargées peuvent provoquer un
incendie ou une électrocution.
•Température ambiante élevée : Dans le cas d'une installation dans un rack
fermé, la température de fonctionnement de l'environnement du rack peut
être plus élevée que celle de la pièce ambiante. Faites attention à ne pas
dépasser une température ambiante du commutateur de 50 degrés.
•Ventilation réduite : Installez l'équipement dans le rack afin que la
quantité de ventilation pour un fonctionnement en toute sécurité de
l'équipement ne soit pas compromise.
•Mise à la terre fiable : Assurez une mise à la terre fiable de l'équipement
monté en rack. Faites particulièrement attention aux branchements
d'alimentation autre que les connexions directes au circuit de dérivation,
par exemple : utilisation de multiprises.
•Le produit ne doit pas être monté avec le panneau arrière faisant face
au sol.
Installation du système ReadyRails de Dell
Le système de montage en rack ReadyRails est fourni pour configurer
facilement votre rack pour l'installation de votre commutateur. Le système
ReadyRails peut être installé à l'aide d'une méthode sans outil 1U ou selon
l'une des trois méthodes utilisant des outils possibles (montage encastré à
deux postes, montage centré à deux postes ou filetage à quatre postes).
92Installation
Page 95
Configuration 1U sans outil (Trou carré à quatre postes ou trou rond non-fileté)
1
Les crochets de la collerette ReadyRails vers l'extérieur, installez un rail
entre les postes verticaux gauche et droit. Alignez puis placez les taquets
du rail de la collerette arrière dans la collerette du poste vertical arrière.
Dans la Figure 3, l'élément 1 et ses extractions illustrent la manière dont
les taquets apparaissent dans les trous carrés ou les trous ronds non filetés.
Figure 3. Configuration 1U sans outil
2
Alignez et placez les taquets de la collerette avant dans les trous sur l'avant
du poste vertical. Reportez-vous à la Figure 3, élément 2.
3
Répétez cette procédure pour le second rail.
4
Pour retirer chaque rail, poussez le bouton du loquet d'éjection de chaque
collerette et désinstallez chaque rail. Reportez-vous à la Figure 3,
élément 3.
Installation93
Page 96
Configuration du montage intégré à deux postes
1
Pour cette configuration, les pièces moulées doivent être retirées de l'avant
de chaque assemblage ReadyRails. Reportez-vous à la Figure 4, élément 1 à
la page 94. Utilisez un tournevis Torx pour retirer les deux vis de chaque
collerette avant (sur le côté du commutateur du rail) puis retirez chaque
pièce moulée. Conservez les pièces moulées pour plus tard. Il n'est pas
nécessaire de retirer les pièces moulées de la collerette arrière.
Figure 4. Configuration du montage intégré à deux postes
2
Fixez un rail sur la collerette du poste avant à l'aide des deux vis fournies
par l'utilisateur. Reportez-vous à la Figure 4, élément 2.
94Installation
Page 97
3
Faites glisser le support piston vers l'avant contre poste vertical et fixez-le à
la collerette du poste à l'aide des deux vis fournies par l'utilisateur.
Reportez-vous à la Figure 4, élément 3.
4
Répétez cette procédure pour le second rail.
Configuration du montage centré à deux postes
1
Faites glisser le support piston vers l'arrière jusqu'à ce qu'il s'enclenche
fixez-le à la collerette du poste à l'aide des deux vis fournies par
l'utilisateur. Reportez-vous à la Figure 5, élément 1.
Figure 5. Configuration du montage centré à deux postes
2
Faites glisser le support arrière vers l'avant du poste et fixez-le à la
collerette du poste à l'aide des deux vis fournies par l'utilisateur.
Reportezvous à la Figure 5, élément 2.
3
Répétez cette procédure pour le second rail.
Installation95
Page 98
Configuration filetée à quatre postes
1
Pour cette configuration, les pièces moulées de la collerette doivent être
retirées de chaque extrémité des assemblages ReadyRails. Utilisez un
tournevis Torx pour retirer les deux vis de chaque collerette et retirer
chaque pièce moulée. Reportez-vous à la Figure 6, élément 1 à la page 96.
Conservez les pièces moulées pour plus tard.
2
Pour chaque rail, fixez les collerettes avant et arrière aux collerettes du
poste à l'aide des deux vis fournies par l'utilisateur à chaque extrémité.
Reportez-vous à la Figure 6, élément 2 à la page 96.
Figure 6. Configuration filetée à quatre postes
96Installation
Page 99
Installation du commutateur
Le commutateur peut être monté dans une configuration rack avant 1U et
dans les configurations à deux postes 1U (intégrée et centrée). Ci-dessous est
un exemple d'une configuration de rack avant 1U. Pour les configurations à
deux postes 1U (intégrée et centrée), vous pouvez faire glisser le
commutateur dans les rails de la même manière que pour les configurations
à quatre postes.
Installation du rack avant 1U
Les rails fixés au commutateur doivent être configurés.
Fixez les rails du commutateur (membres du châssis interne) au
1
commutateur PC81xx. Figure 7, l'élément 1 décrit les détails du picot de
fixation avant avec la patte de verrouillage.
Figure 7. Fixation des rails du commutateur
2
Une fois les deux rails du commutateur installés, alignez-les avec les
Ready-Rails précédemment fixés au rack et faites glisser le commutateur
jusqu'à ce qu'il s'intègre à l'avant du rack. Environ 8 centimètres avant
l'insertion totale, la fonction de verrouillage du rail s'active afin d'empêcher
le commutateur de glisser en dehors du rack et de tomber par
inadvertance.
Installation97
Page 100
Démarrage et configuration
du commutateur
L'organigramme ci-dessous présente un aperçu des étapes que vous devez
effectuer lors de la configuration initiale après avoir déballé et monté le
commutateur.
Figure 8. Organigramme des procédures d'installation et de configuration
Connexion de
l'alimentation
et de la console
Mise sous tension
Oui
Choix de l'option 2
Menu d'amorçage
(fonctions
spéciales)
Redémarrage
Entrer
dans le menu
d'amorçage ?
Non
Chargement du
programme de la
mémoire flash
vers la RAM
Entrer
dans l'Assistant ?
Non
Configuration
initiale manuelle
Configuration
avancée
98Démarrage et configuration du commutateur
Oui
Assistant de
configuration Easy
Setup
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.