Delfield ST4048-MD1, ST407-23, 406CA-DHL, 406P Owner’s Manual

Compact Refrigerators & Freezers
400 & 4000 Series
Original Instructions Installation, Operation and Maintenance Manual
This manual is updated as new information and models are released. Visit our website for the latest manual.
*9294045*
Part Number: 9294045 07/17
Safety Notices
Warning
Read this manual thoroughly before operating, installing or performing maintenance on the equipment. Failure to follow instructions in this manual can cause property damage, injury or death.
DANGER
Do not install or operate equipment that has been misused, abused, neglected, damaged, or altered/ modified from that of original manufactured specifications.
DANGER
Keep power cord AWAY from HEATED surfaces. DO NOT immerse power cord or plug in water. DO NOT let power cord hang over edge of table or counter.
DANGER
All utility connections and fixtures must be maintained in accordance with Local and national codes.
Warning
Authorized Service Representatives are obligated to follow industry standard safety procedures, including, but not limited to, local/national regulations for disconnection / lock out / tag out procedures for all utilities including electric, gas, water and steam.
Warning
Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. Never use flammable oil soaked cloths or combustible cleaning solutions, for cleaning.
Warning
Do not use electrical appliances or accessories other than those supplied by the manufacturer.
Warning
Use caution when handling metal surface edges of all equipment.
Warning
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision concerning use of the appliance by a person responsible for their safety. Do not allow children to play with this appliance.
Caution
Use caution handling, moving and use of the R290 refrigerators to avoid either damaging the refrigerant tubing or increasing the risk of a leak. Components shall be replaced with like components. Servicing shall be done by a factory authorized service personnel to minimize the risk of possible ignition due to incorrect parts or improper service.
Notice
Proper installation, care and maintenance are essential for maximum performance and trouble-free operation of your equipment. Visit our website www. mtwkitchencare.com for manual updates, translations, or contact information for service agents in your area.
Warning
This product contains chemicals known to the State of California to cause cancer and/or birth defects or other reproductive harm. Operation, installation, and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers, crystalline silica, and/or carbon monoxide. Inhalation of airborne particles of glasswool or ceramic fibers is known to the State of California to cause cancer. Inhalation of carbon monoxide is known to the State of California to cause birth defects or other reproductive harm.
Section 1 General Information
Section 2 Installation
Section 3 Operation
Table of Contents
Model Numbers .................................................................................................................. 4
Serial Number Location ..................................................................................................... 4
Warranty Information ........................................................................................................ 4
Regulatory Certifications ..................................................................................................4
Location ..............................................................................................................................5
Weight of Equipment .........................................................................................................6
Clearance Requirements ....................................................................................................6
Dimensions ......................................................................................................................... 6
Electrical Service ................................................................................................................ 7
Voltage .......................................................................................................................................................7
Ground Fault Circuit Interrupter .......................................................................................................7
Rated Amperages, Horsepower, Voltage & Power Cord Chart ...............................................7
Refrigeration ......................................................................................................................7
Drain Connections ..............................................................................................................7
Caster Or Leg Installation .................................................................................................. 8
Leg Leveling .............................................................................................................................................8
Caster and Leg Mounting Detail .......................................................................................................9
Loosen Freezer Compressor Bolts ..................................................................................... 9
Section 4 Maintenance
Section 5 Troubleshooting
Controls/Programming/Settings ....................................................................................11
R404A Refrigerators ............................................................................................................................ 11
R290 Refrigerators ............................................................................................................................... 11
Freezers ................................................................................................................................................... 12
Evaporator Fan Operation ................................................................................................................ 12
Interior Cleaning ..............................................................................................................14
Preventing Blower Coil Corrosion ................................................................................................. 14
Exterior Cleaning..............................................................................................................14
Drain ......................................................................................................................................................... 14
Cleaning the Condenser Coil ...........................................................................................14
Doors/Hinges .................................................................................................................... 14
Problem -> Cause -> Correction Chart ............................................................................15
Part Number: 9294045 07/17 3
Section 1
General Information
Model Numbers
This manual covers standard units only.
NOTE: For custom units, consult Manitowoc KitchenCare at 1-844-724-CARE.
Work Top Refrigerator Bases With Stainless Steel Top &
Backsplash
402P ST4048P
Undercounter Refrigerator Bases With Stainless Steel Top
406P UC4048P
Undercounter Refrigerator With Subtop And 3.75” Casters
406CAP
The prefix P on a model number indicates the use of the refrigerant propane.
Undercounter Freezer Base With Stainless Steel Top
407
Undercounter Freezer With Subtop And 3.75” Casters
407CA
Serial Number Location
The serial number on 400 series compact refrigerators and freezers is printed on the right side of the interior back wall.
The serial tag on 4000 series compact refrigerators and freezers is located either on the left upper sidewall inside the cabinet or under the top nosing directly above the door when the door is in the closed position (right hand door when there are two doors).
Always have the serial number of your unit available when calling for parts or service.
Warranty Information
Visit
http://www.delfield.com/warranty to:
Register your product for warranty.
Verify warranty information.
View and download a copy of your warranty.
Regulatory Certifications
Models are certified by:
National Sanitation Foundation (NSF)
Underwriters Laboratories (UL)
Underwriters Laboratories of Canada (cUL)
4 Part Number: 9294045 07/17
Section 2
Installation
DANGER
Installation must comply with all applicable fire and health codes in your jurisdiction.
Caution
Do not position the air intake vent near steam or heat exhaust of another appliance.
DANGER
Use appropriate safety equipment during installation and servicing
Warning
Remove all removable panels before lifting and installing.
Warning
Do not damage the refrigeration circuit when installing, maintaining or servicing the unit.
Location
Warning
This equipment must be positioned so that the plug is accessible unless other means for disconnection from the power supply (e.g., circuit breaker or disconnect switch) is provided.
Warning
Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to the electrical conduit or gas lines.
The location selected for the equipment must meet the following criteria. If any of these criteria are not met, select another location.
Units are intended for indoor use only.
The location MUST be level, stable and capable of supporting the weight of the equipment.
The location MUST be free from and clear of combustible materials.
Equipment MUST be level both front to back and side to side.
Position the equipment so it will not tip or slide.
Front casters MUST be locked once positioned.
Recommended air temperature is 41° - 86°F (5° - 30°C).
Proper air supply for ventilation is REQUIRED AND CRITICAL for safe and efficient operation. Refer to Clearance Requirements chart on page 6.
Do not obstruct the flow of ventilation air. Make sure the air vents of the equipment are not blocked.
Do not install the equipment directly over a drain. Steam rising up out of the drain will adversely affect operation, air circulation, and damage electrical / electronic components.
Warning
To avoid instability the installation area must be capable of supporting the combined weight of the equipment and product. Additionally the equipment must be level side to side and front to back.
Warning
This equipment is intended for indoor use only. Do not install or operate this equipment in outdoor areas.