Installation, Operation and Maintenance Manual
by Deleld
Original Document
Part Number 9291493 Rev00 11/19
Caution
,
Read this instruction before operating this equipment.
Safety Notices
Warning
n
Read this manual thoroughly before operating, installing or performing maintenance on the equipment. Failure to follow instructions in this manual can cause property damage, injury or death.
DANGER
Failure to disconnect the power at the main power supply disconnect could result in serious injury or death. The power switch DOES NOT disconnect all incoming power.
DANGER
Do not install or operate equipment that has been misused, abused, neglected, damaged, or altered/ modified from that of original manufactured specifications.
DANGER
All utility connections and fixtures must be maintained in accordance with local and national codes.
DANGER
Serious injury or death can occur from inhaling high concentrations of refrigerant vapors. These vapors also reduce oxygen levels in confined areas. Contact with liquid can cause frostbite. All containers, equipment and hoses are under high pressure. Do not puncture or damage these components.
Warning
n
This product contains chemicals known to the State of California to cause cancer and/or birth defects or other reproductive harm. Operation, installation, and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers, crystalline silica, and/or carbon monoxide. Inhalation of airborne particles of glasswool or ceramic fibers is known to the State of California to cause cancer. Inhalation of carbon monoxide is known to the State of California to cause birth defects or other reproductive harm.
Warning
n
Authorized Service Representatives are obligated to follow industry standard safety procedures, including, but not limited to, local/national regulations for disconnection / lock out / tag out procedures for all utilities including electric, gas, water and steam.
Warning
n
DO NOT touch refrigeration lines inside units; some may exceed temperatures of 200°F (93.3°C).
Warning
n
Do not damage the refrigeration circuit when installing, maintaining or servicing the unit.
Caution
,
Maintenance and servicing work, other than cleaning as described in this manual, must be done by an authorized service personnel.
Warning
n
Use caution when handling metal surface edges of all equipment.
Warning
n
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision concerning use of the appliance by a person responsible for their safety. Do not allow children to play with this appliance.
Warning
n
Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. Never use flammable oil soaked cloths or combustible cleaning solutions, for cleaning.
Notice
Proper installation, care and maintenance are essential for maximum performance and trouble-free operation of your equipment. Visit our website www. mtwkitchencare.com for manual updates, translations, or contact information for service agents in your area.
Section 1 General Information
Section 2 Installation
Section 3 Operation
Table of Contents
Model Numbers .................................................................................................................. 5
Options ................................................................................................................................6
Serial Number Location ..................................................................................................... 6
Warranty Information ........................................................................................................ 6
Regulatory Certifications ..................................................................................................6
Location ..............................................................................................................................7
Weight .................................................................................................................................7
Clearance Requirements ....................................................................................................9
Dimensions ......................................................................................................................... 9
Electrical Service ..............................................................................................................11
Voltage .................................................................................................................................................... 11
Ground Fault Circuit Interrupter .................................................................................................... 11
Rated Amperages, Horsepower & Voltage Chart ..................................................................... 12
Drain Connections ............................................................................................................14
Refrigeration ....................................................................................................................14
Leveling .............................................................................................................................15
Stabilizing .........................................................................................................................15
Leg & Caster Installation ..................................................................................................15
Accessory Installation ......................................................................................................15
Section 4 Maintenance
Frost Top Serving Counter Operation .............................................................................17
Refrigerated Cold Pan Serving Counter Operation ....................................................... 17
Refrigerated Cold Pan with LiquiTec Serving Counter Operation ................................ 18
ERC112 Temperature Control & Display ...................................................................................... 18
Changing Display from Fahrenheit to Celsius on ERC112 Control .................................... 19
Heated Serving Counter Operation ................................................................................20
Heated and Refrigerated Combo Counter Operation ...................................................21
Heated Section Operation ............................................................................................................... 21
Refrigerated Section Operation ..................................................................................................... 22
Option Self Contained Combination Hot/Cold Food Wells, N8600 Series, Operation 23 Option Individually Controlled Energy Savings Heated Food Wells, DESP Series,
Operation ..........................................................................................................................24
Cleaning and Sanitizing Procedures ...............................................................................25
General .................................................................................................................................................... 25
Interior Cleaning .................................................................................................................................. 26
Exterior Cleaning ................................................................................................................................. 26
Cleaning the Condenser Coil .......................................................................................................... 27
Drain Maintenance ............................................................................................................................. 27
Doors/Hinges ........................................................................................................................................ 27
Part Number: 9291493 REV00 11/19 3
Table of Contents (continued)
THIS PAGE INTENTIONALLY LEFT BLANK
4 Part Number: 9291493 REV00 11/19
Section 1
General Information
Model Numbers
This manual covers the following standard counters.
Description Shelleyglas® Shelleysteel®
KC-28 SC-28
KC-28-NU SC-28-NU
KC-36 SC-36
KC-36-NU SC-36-NU
KC-50 SC-50
Mobile All-Purpose
Counters
Frost Top Serving
Counters
Mobile Ice Pan
Counter
Mobile Cashier’s
Counters
Refrigerated
Cold Pan Serving
Counters
Refrigerated
Cold Pan Serving
Counters with
LiquiTec
Triangle Corner
Counter
Mobile Tray and
Silver Stands
KC-50-NU SC-50-NU
KC-60 SC-60
KC-60-NU SC-60-NU
KC-74 SC-74
KC-74-NU SC-74-NU
KC-96 SC-96
KC-96-NU SC-96-NU KCFT-36-NU SCFT-36-NU KCFT-50-NU SCFT-50-NU KCFT-60-NU SCFT-60-NU KCFT-74-NU SCFT-74-NU KCFT-96-NU SCFT-96-NU
KCI-36 SCI-36
KCI-36-NU SCI-36-NU
KCI-50 SCI-50
KCI-50-NU SCI-50-NU
KCI-60 SCI-60
KCI-60-NU SCI-60-NU
KCI-74 SCI-74
KCI-74-NU SCI-74-NU
KCI-96 SCI-96
KCI-96-NU SCI-96-NU
KCS-30 SCS-30 KCS-36 SCS-36
KCS-50 SCS-50 KCSC-36B SCSC-36B KCSC-50B SCSC-50B KCSC-60B SCSC-60B KCSC-74B SCSC-74B KCSC-96B SCSC-96B
KCSC-36-EF SCSC-36-EF KCSC-50-EF SCSC-50-EF KCSC-60-EF SCSC-60-EF KCSC-74-EF SCSC-74-EF KCSC-96-EF SCSC-96-EF
NA SC-TRI
SC-TRIOS KCTS-28 SCTS-28 KCTS-36 SCTS-36
Description Shelleyglas® Shelleysteel®
Mobile Beverage
Counters
Heated Serving
Counters
Heated and Ice Cooled Combo
Counters
Heated and
Refrigerated
Combo Counters
Trimline L-shaped
Heated Serving
Counter
Carving Counter KRB SRB
KCU-36 SCU-36
KCU-36-NU SCU-36-NU
KCU-50 SCU-50
KCU-50-NU SCU-50-NU
KCU-60 SCU-60
KCU-60-NU SCU-60-NU
KCU-74 SCU-74
KCU-74-NU SCU-74-NU
KCU-96 SCU-96
KCU-96-NU SCU-96-NU
KH-2 SH-2
KH-2-NU SH-2-NU
KH-3 SH-3
KH-3-NU SH-3-NU
KH-4 SH-4
KH-4-NU SH-4-NU
KH-5 SH-5
KH-5-NU SH-5-NU
KH-6 SH-6
KH-6-NU SH-6-NU KHC-50-NU SHC-50-NU KHC-60-NU SHC-60-NU KHC-74-NU SHC-74-NU KHC-96-NU SHC-96-NU
NA SH2C-62-NU KH2C-74-NU SH2C-74-NU KH2C-96-NU SH2C-96-NU KH3C-96-NU SH3C-96-NU KH4C-96-NU SH4C-96-NU
KHCR-50-B SHCR-50-B KHCR-60-B SHCR-60-B KHCR-74-B SHCR-74-B KHCR-96-B SHCR-96-B
NA SH2CR-62-B KH2CR-74-B SH2CR-74-B KH2CR-96-B SH2CR-96-B KH3CR-96-B SH3CR-96-B KH4CR-96-B SH4CR-96-B
NA SLT4 (-L or -R)
Part Number: 9291493 REV00 11/19 5
General Information Section 1
Options
This manual covers the following options. For other custom counters, consult the customer service department.
Description Option
N8630
Self Contained Combination Hot/Cold
Food Wells
Individually Controlled Energy Savings
Heated Food Wells
N8643 N8656 N8669
N8681 1 Well DESP 2 Well DESP 3 Well DESP 4 Well DESP 5 Well DESP 6 Well DESP
Serial Number Location
Always have the serial number of your unit available when calling for parts or service. Serial numbers are printed on serial tags.
Heated counter serial tags are located above the louvered panel near the on/off switch.
Refrigerated counter serial tags are located in the compressor area near the on/off switch.
Utility counters with understorage often have the serial tag located on the left inside the storage area.
All purpose counters, utility equipment or delivery carts do not require serial numbers but a serial tag is placed at the top of the pylon on the back of the unit.
Warranty Information
Register your product for warranty,
Verify warranty information,
View and download a copy of your warranty,
at www.delfield.com/warranty
Regulatory Certifications
All models are certified by:
National Sanitation Foundation (NSF)
All models with electrical are certified by:
Underwriters Laboratories (UL)
Underwriters Laboratories of Canada (cUL)
6 Part Number: 9291493 REV00 11/19
Section 2
Installation
DANGER
Installation must comply with all applicable fire and health codes in your jurisdiction.
DANGER
Use appropriate safety equipment during installation and servicing
Warning
n
Remove all removable panels before lifting and installing.
Location
Warning
n
This equipment must be positioned so that the plug is accessible unless other means for disconnection from the power supply (e.g., circuit breaker or disconnect switch) is provided.
Warning
n
Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to the electrical conduit or gas lines.
Warning
n
To avoid instability the installation area must be capable of supporting the combined weight of the equipment and product. Additionally the equipment must be level side to side and front to back.
Warning
n
This equipment is intended for indoor use only. Do not install or operate this equipment in outdoor areas.
Caution
,
Do not position the air intake vent near steam or heat exhaust of another appliance.
The location selected for the equipment must meet the following criteria. If any of these criteria are not met, select another location.
Units are intended for indoor use only.
The location MUST be level, stable and capable of supporting the weight of the equipment.
The location MUST be free from and clear of combustible materials.
Equipment MUST be level both front to back and side to side.
Position the equipment so it will not tip or slide.
Front casters MUST be locked once positioned.
Recommended air temperature is 60° - 100°F (16° - 38°C).
Proper air supply for ventilation is REQUIRED AND CRITICAL for safe and efficient operation. Refer to Clearance Requirements chart on page 9.
Do not obstruct the flow of ventilation air. Make sure the air vents of the equipment are not blocked.
Do not install the equipment directly over a drain. Steam rising up out of the drain will adversely affect operation, air circulation, and damage electrical / electronic components.
Weight
Shelleyglas® Shelleysteel® Weight
Mobile All-Purpose Counters
KC-28 SC-28 165lbs (75kg)
KC-28-NU SC-28-NU 120lbs (54kg)
KC-36 SC-36 185lbs (84kg)
KC-36-NU SC-36-NU 160lbs (73kg)
KC-50 SC-50 205lbs (93kg)
KC-50-NU SC-50-NU 180lbs (82kg)
KC-60 SC-60 240lbs (109kg)
KC-60-NU SC-60-NU 210lbs (95kg)
KC-74 SC-74 270lbs (123kg)
KC-74-NU SC-74-NU 240lbs (109kg)
KC-96 SC-96 310lbs (141kg)
KC-96-NU SC-96-NU 280lbs (127kg)
Frost Top Serving Counters
KCFT-36-NU SCFT-36-NU 380lbs (172kg) KCFT-50-NU SCFT-50-NU 455lbs (206kg) KCFT-60-NU SCFT-60-NU 540lbs (245kg) KCFT-74-NU SCFT-74-NU 610lbs (277kg) KCFT-96-NU SCFT-96-NU 680lbs (308kg)
Part Number: 9291493 REV00 11/19 7
Installation Section 2
Shelleyglas® Shelleysteel® Weight
Mobile Ice Pan Counter
KCI-36 SCI-36 240lbs (109kg)
KCI-36-NU SCI-36-NU 200lbs (91kg)
KCI-50 SCI-50 285lbs (129kg)
KCI-50-NU SCI-50-NU 245lbs (111kg)
KCI-60 SCI-60 320lbs (145kg)
KCI-60-NU SCI-60-NU 280lbs (127kg)
KCI-74 SCI-74 360lbs (163kg)
KCI-74-NU SCI-74-NU 330lbs (150kg)
KCI-96 SCI-96 400lbs (181kg)
KCI-96-NU SCI-96-NU 380lbs (172kg)
Mobile Cashier’s Counters
KCS-30 SCS-30 180lbs (82kg) KCS-36 SCS-36 210lbs (95kg) KCS-50 SCS-50 270lbs (122kg)
Refrigerated Cold Pan Serving Counters
KCSC-36B SCSC-36B 350lbs (159kg) KCSC-50B SCSC-50B 425lbs (193kg) KCSC-60B SCSC-60B 500lbs (227kg) KCSC-74B SCSC-74B 575lbs (261kg) KCSC-96B SCSC-96B 650lbs (295kg)
Refrigerated Cold Pan Serving Counters with LiquiTec
KCSC-36-EF SCSC-36-EF 380lbs (172kg) KCSC-50-EF SCSC-50-EF 455lbs (206kg) KCSC-60-EF SCSC-60-EF 530lbs (240kg) KCSC-74-EF SCSC-74-EF 615lbs (279kg) KCSC-96-EF SCSC-96-EF 680lbs (308kg)
Triangle Corner Counter
NA SC-TRI 160lbs (73kg)
SC-TRIOS 160lbs (73kg)
Mobile Tray and Silver Stands
KCTS-28 SCTS-28 150lbs (68kg) KCTS-36 SCTS-36 192lbs (87kg)
Mobile Beverage Counters
KCU-36 SCU-36 200lbs (91kg)
KCU-36-NU SCU-36-NU 170lbs (77kg)
KCU-50 SCU-50 230lbs (104kg)
KCU-50-NU SCU-50-NU 190lbs (86kg)
KCU-60 SCU-60 270lbs (123kg)
KCU-60-NU SCU-60-NU 230lbs (104kg)
KCU-74 SCU-74 300lbs (136kg)
KCU-74-NU SCU-74-NU 260lbs (118kg)
KCU-96 SCU-96 340lbs (154kg)
KCU-96-NU SCU-96-NU 300lbs (136kg)
Heated Serving Counters
KH-2 SH-2 380lbs (172kg)
KH-2-NU SH-2-NU 225lbs (102kg)
KH-3 SH-3 460lbs (209kg)
KH-3-NU SH-3-NU 275lbs (125kg)
KH-4 SH-4 550lbs (250kg)
KH-4-NU SH-4-NU 330lbs (150kg)
KH-5 SH-5 660lbs (299kg)
KH-5-NU SH-5-NU 420lbs (191kg)
KH-6 SH-6 720lbs (327kg)
KH-6-NU SH-6-NU 510lbs (231kg)
Shelleyglas® Shelleysteel® Weight
Heated and Ice Cooled Combo Counters
KHC-50-NU SHC-50-NU 300lbs (136kg) KHC-60-NU SHC-60-NU 350lbs (159kg) KHC-74-NU SHC-74-NU 400lbs (181kg) KHC-96-NU SHC-96-NU 425lbs (193kg)
NA SH2C-62-NU 350lbs (159kg) KH2C-74-NU SH2C-74-NU 410lbs (186kg) KH2C-96-NU SH2C-96-NU 430lbs (195kg) KH3C-96-NU SH3C-96-NU 450lbs (204kg) KH4C-96-NU SH4C-96-NU 460lbs (209kg)
Heated and Refrigerated Combo Counters
KHCR-50-B SHCR-50-B 475lbs (216kg) KHCR-60-B SHCR-60-B 575lbs (261kg) KHCR-74-B SHCR-74-B 688lbs (312kg) KHCR-96-B SHCR-96-B 730lbs (331kg)
NA SH2CR-62-B 575lbs (261kg)
KH2CR-74-B SH2CR-74-B 690lbs (313kg) KH2CR-96-B SH2CR-96-B 740lbs (336kg) KH3CR-96-B SH3CR-96-B 750lbs (340kg) KH4CR-96-B SH4CR-96-B 760lbs ( 345kg)
Trimline L-shaped Heated Serving Counter
NA SLT4 (-L or -R) 300lbs (136kg)
Carving Counter
KRB SRB 180lbs (82kg)
OPTION WEIGHTS
Option Weight
Self Contained Combination Hot/Cold Food Wells
N8630 164lbs (74kg) N8643 198lbs (90kg) N8656 233lbs (106kg) N8669 266lbs (121kg) N8681 301lbs (137kg)
Individually Controlled Energy Savings Heated Food Wells
1 Well DESP 41lbs (19kg) 2 Well DESP 99lbs (45kg) 3 Well DESP 134lbs (61kg) 4 Well DESP 166lbs (75kg) 5 Well DESP 186lbs (84kg) 6 Well DESP 236lbs (107kg)
8 Part Number: 9291493 REV00 11/19
Section 2 Installation
Clearance Requirements
DANGER
The flooring under the appliance must be made of a noncombustible material.
DANGER
Risk of fire/shock. Do not obstruct vents or openings.
Equipment Clearance
Option Self Contained Combination Hot/
Cold Food Wells, N8600 Series
Option Individually Controlled Energy
Savings Heated Food Wells, DESP Series
3” (8cm) on sides
and bottom
3” (8cm) on sides
and bottom
Dimensions
Shelleyglas® Shelleysteel®
Mobile All-Purpose Counters
KC-28
KC-28-NU
KC-36
KC-36-NU
KC-50
KC-50-NU
KC-60
KC-60-NU
KC-74
KC-74-NU
KC-96
KC-96-NU
KCFT-36-NU SCFT-36-NU 36”
KCFT-50-NU SCFT-50-NU 50”
KCFT-60-NU SCFT-60-NU 60”
KCFT-74-NU SCFT-74-NU 74”
KCFT-96-NU SCFT-96-NU 96”
KCI-36
KCI-36-NU
KCI-50
KCI-50-NU
KCI-60
KCI-60-NU
KCI-74
KCI-74-NU
KCI-96
KCI-96-NU
KCS-30 SCS-30 30”
KCS-36 SCS-36 36”
KCS-50 SCS-50 50”
KCSC-36B SCSC-36B 36”
KCSC-50B SCSC-50B 50”
KCSC-60B SCSC-60B 60”
KCSC-74B SCSC-74B 74”
KCSC-96B SCSC-96B 96”
SC-28
SC-28-NU
SC-36
SC-36-NU
SC-50
SC-50-NU
SC-60
SC-60-NU
SC-74
SC-74-NU
SC-96
SC-96-NU
Frost Top Serving Counters
Mobile Ice Pan Counter
SCI-36
SCI-36-NU
SCI-50
SCI-50-NU
SCI-60
SCI-60-NU
SCI-74
SCI-74-NU
SCI-96
SCI-96-NU
Mobile Cashier’s Counters
Refrigerated Cold Pan Serving Counters
Length Depth Height
(71cm)
(91cm)
(127cm)
(152cm)
(188cm)
(244cm)
(91cm)
(127cm)
(152cm)
(188cm)
(244cm)
(91cm)
(127cm)
(152cm)
(188cm)
(244cm)
(76cm)
(91cm)
(127cm)
(91cm)
(127cm)
(152cm)
(188cm)
(244cm)
28”
36”
50”
60”
74”
96”
36”
50”
60”
74”
96”
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
30”
(76cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
36”
(91cm)
Part Number: 9291493 REV00 11/19 9