Series GC, GB & GBS Reach-Ins
CoolScapes™
Original Instructions
Installation, Operation and Maintenance Manual
This manual is updated as new information and models are released. Visit our website for the latest manual.
Part Number: 9294839 11/17
Safety Notices
nWarning
Read this manual thoroughly before operating, installing or performing maintenance on the equipment. Failure to follow instructions in this manual can cause property damage, injury or death.
DANGER
Do not install or operate equipment that has been misused, abused, neglected, damaged, or altered/ modified from that of original manufactured specifications.
DANGER
Keep power cord AWAY from HEATED surfaces. DO NOT immerse power cord or plug in water. DO NOT let power cord hang over edge of table or counter.
DANGER
All utility connections and fixtures must be maintained in accordance with Local and national codes.
nWarning
Authorized Service Representatives are obligated to follow industry standard safety procedures, including, but not limited to, local/national regulations for disconnection / lock out / tag out procedures for all utilities including electric, gas, water and steam.
nWarning
Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. Never use flammable oil soaked cloths or combustible cleaning solutions, for cleaning.
nWarning
This product contains chemicals known to the State of California to cause cancer and/or birth defects or other reproductive harm. Operation, installation, and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers, crystalline silica, and/or carbon monoxide. Inhalation of airborne particles of glasswool or ceramic fibers is known to the State of California to cause cancer. Inhalation of carbon monoxide is known to the State of California to cause birth defects or other reproductive harm.
nWarning
Do not use electrical appliances or accessories other than those supplied by the manufacturer.
nWarning
Use caution when handling metal surface edges of all equipment.
nWarning
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision concerning use of the appliance by a person responsible for their safety. Do not allow children to play with this appliance.
,Caution
Use caution handling, moving and use of the R290 refrigerators to avoid either damaging the refrigerant tubing or increasing the risk of a leak. Components shall be replaced with like components. Servicing shall be done by a factory authorized service personnel to minimize the risk of possible ignition due to incorrect parts or improper service.
Notic
Proper installation, care and maintenance are essential for maximum performance and trouble-free operation of your equipment. Visit our website www. mtwkitchencare.com for manual updates, translations, or contact information for service agents in your area.
Table of Contents
Section 1 |
|
General Information |
|
Model Numbers................................................................................................................... |
5 |
Serial Number Information................................................................................................ |
5 |
Warranty Information......................................................................................................... |
5 |
Regulatory Certifications................................................................................................... |
5 |
Section 2 |
|
Installation |
|
Location............................................................................................................................... |
7 |
Weight of Equipment.......................................................................................................... |
8 |
Clearance Requirements.................................................................................................... |
8 |
Drain Connections.............................................................................................................. |
8 |
Dimensions.......................................................................................................................... |
9 |
Electrical Service............................................................................................................... |
10 |
Refrigeration..................................................................................................................... |
11 |
Leveling............................................................................................................................. |
12 |
Stabilizing.......................................................................................................................... |
12 |
Leg & Caster Installation.................................................................................................. |
12 |
Shelf Installation............................................................................................................... |
13 |
Applicable to GC Models................................................................................................................... |
13 |
Applicable to GB Models................................................................................................................... |
13 |
Reversible Full Door Instructions.................................................................................... |
14 |
New top Hinge Supplied with GB Models.................................................................................. |
14 |
GC Alternate Hinge Must Be Purchased...................................................................................... |
14 |
Reversible Half Door Instructions.................................................................................... |
15 |
New Top and Center Hinges Must Be Purchased..................................................................... |
15 |
Pilaster Clip Kit Installation Instructions........................................................................ |
17 |
Applicable to GC Models................................................................................................................... |
17 |
New Bottom Hinge Cartridge Installation...................................................................... |
18 |
T-1 Tray Slide Installation................................................................................................. |
19 |
T-2 Tray Slide Installation................................................................................................. |
20 |
T-3 Tray Slide Installation................................................................................................. |
21 |
T-4 Rack Slide Installation................................................................................................ |
22 |
Section 3 |
|
Operation |
|
R290 Controls/Programming/Settings............................................................................ |
23 |
R290 Temperature Control & Display............................................................................................ |
24 |
R290 Evaporator Fan Operation..................................................................................................... |
25 |
R290 Changing Display from Fahrenheit to Celsius on ERC112 Control.......................... |
26 |
Section 4 |
|
Maintenance |
|
Cleaning and Sanitizing Procedures............................................................................... |
27 |
General.................................................................................................................................................... |
27 |
Interior Cleaning.................................................................................................................................. |
28 |
Exterior Cleaning.................................................................................................................................. |
28 |
Drain......................................................................................................................................................... |
29 |
Cleaning the Condenser Coil........................................................................................................... |
29 |
Casters...................................................................................................................................................... |
29 |
Doors/Hinges........................................................................................................................................ |
29 |
Preventing Blower Coil Corrosion.................................................................................................. |
29 |
Part Number: 9294839 11/17 |
3 |
Table of Contents (continued)
Section 5
Troubleshooting
Problem -> Cause -> Correction Chart............................................................................. |
31 |
4 |
Part Number: 9294839 11/17 |
Section 1
General Information
Model Numbers
This manual covers the following models:
1 Section Refrigerators
Glass Doors |
Solid Doors |
GBR1P-G(H) |
GBR1P-S(H) |
GBSR1P-G(H) |
GBSR1P-S(H) |
GCR1P-G(H) |
GCR1P-S(H) |
|
|
2 Section Refrigerators |
|
Glass Doors |
Solid Doors |
GBR2P-G(H) |
GBR2P-S(H) |
GBSR2P-G(H) |
GBSR2P-S(H) |
GCR2P-G(H) |
GCR2P-S(H) |
|
|
3 Section Refrigerators |
|
Glass Doors |
Solid Doors |
GBR3P-G(H) |
GBR3P-S(H) |
GBSR3P-G(H) |
GBSR3P-S(H) |
GCR3P-G(H) |
GCR3P-S(H) |
|
Solid Doors Freezers |
|
1 Section |
2 Section |
3 Section |
GBF1P-S(H) |
GBF2P-S(H) |
GBF3P-S(H) |
GBSF1P-S(H) |
GBSF2P-S(H) |
GBSF3P-S(H) |
GCF1P-S(H) |
GCF2P-S(H) |
GCF3P-S(H) |
Serial Number Information
The serial number is on the identification plate that also includes the model number. The identification plate is located near the top front corner of the left interior wall.
Always have the serial number of your unit available when calling for parts or service.
Warranty Information
Visit
http://www.delfield.com/warranty to:
•Register your product for warranty.
•Verify warranty information.
•View and download a copy of your warranty.
Regulatory Certifications
Models are certified by:
• National Sanitation Foundation (NSF)
• Underwriters Laboratories (UL)
• Underwriters Laboratories of Canada (cUL)
Part Number: 9294839 11/17 |
5 |
General Information |
Section 1 |
|
|
THIS PAGE INTENTIONALLY LEFT BLANK
6 |
Part Number: 9294839 11/17 |
Section 2
Installation
DANGER
Installation must comply with all applicable fire and health codes in your jurisdiction.
DANGER
Use appropriate safety equipment during installation and servicing.
nWarning
Do not damage the refrigeration circuit when installing, maintaining or servicing the unit.
Location
nWarning
This equipment must be positioned so that the plug is accessible unless other means for disconnection from the power supply (e.g., circuit breaker or disconnect switch) is provided.
nWarning
Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to the electrical conduit or gas lines.
nWarning
To avoid instability the installation area must be capable of supporting the combined weight of the equipment and product. Additionally the equipment must be level side to side and front to back.
nWarning
This equipment is intended for indoor use only. Do not install or operate this equipment in outdoor areas.
The location selected for the equipment must meet the following criteria. If any of these criteria are not met, select another location.
•The location MUST be level, stable and capable of supporting the weight of the equipment.
•The location MUST be free from and clear of combustible materials.
•Equipment MUST be level both front to back and side to side.
•Position the equipment so it will not tip or slide.
•Front casters MUST be locked once positioned.
•Recommended air temperature is 60° - 100°F (16° - 38°C).
•Proper air supply for ventilation is REQUIRED AND CRITICAL for safe and efficient operation. Refer to Clearance Requirements chart on page 8.
•Do not obstruct the flow of ventilation air. Make sure the air vents of the equipment are not blocked.
•Do not install the equipment directly over a drain. Steam rising up out of the drain will adversely affect operation, air circulation, and damage electrical / electronic components.
Part Number: 9294839 11/17 |
7 |
Installation |
Section 2 |
|
|
Weight of Equipment
Description |
|
Models |
|
Weight |
|
|
|
|
|
|
1 Section Refrigerators |
|
||
|
|
|
|
|
Glass Doors |
|
GBR1P-G(H), |
|
|
|
|
GBSR1P-G(H), |
|
236 lbs (107 kg) |
|
|
GCR1P-G(H) |
|
|
|
|
|
|
|
Solid Doors |
|
GBR1P-S(H) |
|
312 lbs (142 kg) |
|
|
|
|
|
|
|
GBSR1P-S(H) |
|
351 lbs (159 kg) |
|
|
|
|
|
|
|
GCR1P-S(H) |
|
282 lbs (128 kg) |
|
|
|
|
|
|
2 Section Refrigerators |
|
||
|
|
|
|
|
Glass Doors |
|
GBR2P-G(H), |
|
|
|
|
GBSR2P-G(H), |
|
322 lbs (146 kg) |
|
|
GCR2P-G(H) |
|
|
|
|
|
|
|
Solid Doors |
|
GBR2P-S(H), |
|
495 lbs (225 kg) |
|
|
GBSR2P-S(H) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GCR2P-S(H) |
|
430 lbs (195 kg) |
|
|
|
|
|
|
3 Section Refrigerators |
|
||
|
|
|
|
|
Glass Doors |
|
GBR3P-G, |
|
|
|
|
GBSR3P-G, |
|
485 lbs (220 kg) |
|
|
GCR3P-G |
|
|
|
|
|
|
|
Solid Doors |
|
GBR3P-S(H) |
|
727 lbs (330 kg) |
|
|
|
|
|
|
|
GBSR3P-S(H) |
|
767 lbs (348 kg) |
|
|
|
|
|
|
|
GCR3P-S(H) |
|
668 lbs (303 kg) |
|
|
|
|
|
|
|
1 Section Freezers |
|
|
|
|
|
|
|
Solid Doors |
|
GBF1P-S(H) |
|
336 lbs (152 kg) |
|
|
|
|
|
|
|
GBSF1P-S(H) |
|
354 lbs (161 kg) |
|
|
|
|
|
|
|
GCF1P-S(H) |
|
299 lbs (136 kg) |
|
|
|
|
|
|
|
2 Section Freezers |
|
|
|
|
|
|
|
Solid Doors |
|
GBF2P-S(H) |
|
532 lbs (241 kg) |
|
|
|
|
|
|
|
GBSF2P-S(H) |
|
495 lbs (225 kg) |
|
|
|
|
|
|
|
GCF2P-S(H) |
|
445 lbs (202 kg) |
|
|
|
|
|
|
|
3 Section Freezers |
|
|
|
|
|
|
|
Solid Doors |
|
GBF3P-S(H), |
|
772 lbs (350 kg) |
|
|
GBSF3P-S(H) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GCF3P-S(H) |
|
707 lbs (321 kg) |
|
|
|
|
|
Clearance Requirements
DANGER
Minimum clearance requirements are the same for noncombustible locations as for combustible locations. The flooring under the appliance must be made of a noncombustible material.
DANGER
Risk of fire/shock. All minimum clearances must be maintained. Do not obstruct vents or openings.
Top
12.00” (305mm)
•Keep the vents clean and free of obstruction.
•Casters or optional legs must be used and not removed.
Drain Connections
nWarning
Moisture collecting from improper drainage can create a slippery surface on the floor and a hazard to employees. It is the owner’s responsibility to provide a container or outlet for drainage.
8 |
Part Number: 9294839 11/17 |
Section 2 |
Installation |
|
|
Dimensions
Model |
|
Length |
Depth |
Height |
|
|
|
|
|
|
1 Section Refrigerators |
|
||
|
|
|
|
|
GBR1P-G(H), |
|
27.34” |
32.44” |
79.50” |
GBR1P-S(H), |
|
(70cm) |
(82cm) |
(202cm) |
GBSR1P-G(H), |
|
|
|
|
GBSR1P-S(H), |
|
|
|
|
GCR1P-G(H), |
|
|
|
|
GCR1P-S(H) |
|
|
|
|
|
|
|
|
|
|
2 Section Refrigerators |
|
||
|
|
|
|
|
GBR2P-G(H), |
|
55.16” |
32.44” |
79.50” |
GBR2P-S(H), |
|
(140cm) |
(82cm) |
(202cm) |
GBSR2P-G(H), |
|
|
|
|
GBSR2P-S(H), |
|
|
|
|
GCR2P-G(H), |
|
|
|
|
GCR2P-S(H) |
|
|
|
|
|
|
|
|
|
|
3 Section Refrigerators |
|
||
|
|
|
|
|
GBR3P-G, |
|
82.97” |
32.44” |
79.50” |
GBR3P-S(H), |
|
(211cm) |
(82cm) |
(202cm) |
GBSR3P-G, |
|
|
|
|
GBSR3P-S(H), |
|
|
|
|
GCR3P-G, |
|
|
|
|
GCR3P-S(H), |
|
|
|
|
|
|
|
|
|
|
1 Section Freezers |
|
||
|
|
|
|
|
GBF1P-S(H), |
|
27.34” |
32.44” |
79.50” |
GBSF1P-S(H), |
|
(70cm) |
(82cm) |
(202cm) |
GCF1P-S(H) |
|
|
|
|
|
|
|
|
|
|
2 Section Freezers |
|
||
|
|
|
|
|
GBF2P-S(H), |
|
55.16” |
32.44” |
79.50” |
GBSF2P-S(H), |
|
(140cm) |
(82cm) |
(202cm) |
GCF2P-S(H) |
|
|
|
|
|
|
|
|
|
|
3 Section Freezers |
|
||
|
|
|
|
|
GBF3P-S(H), |
|
82.97” |
32.44” |
79.50” |
GBSF3P-S(H), |
|
(211cm) |
(82cm) |
(202cm) |
GCF3P-S(H) |
|
|
|
|
|
|
|
|
|
Model |
|
Volume |
|
|
|
|
1 Section Refrigerators |
|
|
|
|
GBR1P-G(H), |
|
21ft3 |
GBR1P-S(H), |
|
(595L) |
GBSR1P-G(H), |
|
|
GBSR1P-S(H), |
|
|
GCR1P-G(H), |
|
|
GCR1P-S(H) |
|
|
|
|
|
|
2 Section Refrigerators |
|
|
|
|
GBR2P-G(H), |
|
46ft3 |
GBR2P-S(H), |
|
(1303L) |
GBSR2P-G(H), |
|
|
GBSR2P-S(H), |
|
|
GCR2P-G(H), |
|
|
GCR2P-S(H) |
|
|
|
|
|
|
3 Section Refrigerators |
|
|
|
|
GBR3P-G, |
|
71ft3 |
GBR3P-S(H), |
|
(2010L) |
GBSR3P-G, |
|
|
GBSR3P-S(H), |
|
|
GCR3P-G, |
|
|
GCR3P-S(H), |
|
|
|
|
|
|
1 Section Freezers |
|
|
|
|
GBF1P-S(H), |
|
21ft3 |
GBSF1P-S(H), |
|
(595L) |
GCF1P-S(H) |
|
|
|
|
|
|
2 Section Freezers |
|
|
|
|
GBF2P-S(H), |
|
46ft3 |
GBSF2P-S(H), |
|
(1303L) |
GCF2P-S(H) |
|
|
|
|
|
|
3 Section Freezers |
|
|
|
|
GBF3P-S(H), |
|
71ft3 |
GBSF3P-S(H), |
|
(2010L) |
GCF3P-S(H) |
|
|
|
|
|
Part Number: 9294839 11/17 |
9 |
Installation |
Section 2 |
|
|
Electrical Service
DANGER
Check all wiring connections, including factory terminals, before operation. Connections can become loose during shipment and installation.
nWarning
This appliance must be grounded and all field wiring must conform to all applicable local and national codes. Refer to rating plate for proper voltage. It is the responsibility of the end user to provide the disconnect means to satisfy the authority having jurisdiction.
•Plug units with R290 refrigerant into a receptacle that is a minimum of 14” (36cm) above the floor.
•All electrical work, including wire routing and grounding, must conform to local, state and national electrical codes.
•The equipment must be grounded.
•A separate fuse/circuit breaker must be provided for each unit.
•Check all green ground screws, cables and wire connections to verify they are tight before start-up.
•The maximum allowable voltage variation is ±10% of the rated voltage at equipment start-up (when the electrical load is highest).
Ground Fault Circuit Interrupter
Ground Fault Circuit Interrupter (GFCI/GFI) protection is a system that shuts down the electric circuit (opens it) when it senses an unexpected loss of power, presumably to ground. Manitowoc does not recommend the use of GFCI/GFI circuit protection to energize our equipment. If code requires the use of a GFCI/GFI then you must
follow the local code. The circuit must be dedicated, sized properly and there must be a panel GFCI/GFI breaker. We do not recommend the use of GFCI/GFI outlets to energize our equipment as they are known for more intermittent nuisance trips than panel breakers.
Rated Amperages, Horsepower, Voltage & Power Cord Chart
Maximum 10ft (3m) cord with plug.
|
|
Models |
Amps |
HP |
V, Hz, Ph |
NEMA |
|
|
|
|
|
|
|
|
Plug |
|
|
|
GBR1P-G(H), |
4.2 |
0.22 |
115, 60, 1 |
5-15p |
|
Section |
|
GBR1P-S(H), |
|
|
|
|
|
|
GBSR1P-S(H), |
|
|
|
|
|
|
|
|
GBSR1P-G(H), |
|
|
|
|
|
1 |
|
GCR1P-G(H) |
|
|
|
|
|
|
|
GCR1P-S(H) |
|
|
|
|
Refrigerators |
Section2 |
|
GBR2P-G(H), |
6.0 |
0.33 |
115, 60, 1 |
5-15p |
|
GBR2P-S(H), |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
GBSR2P-G(H), |
|
|
|
|
|
|
|
GBSR2P-S(H), |
|
|
|
|
|
|
|
GCR2P-G(H) |
|
|
|
|
|
|
|
GCR2P-S(H) |
|
|
|
|
|
|
|
GBR3P-G, |
6.5 |
0.355 |
115, 60, 1 |
5-15p |
|
Section |
|
GBR3P-S(H), |
|
|
|
|
|
|
GBSR3P-S(H), |
|
|
|
|
|
|
|
|
GBSR3P-G, |
|
|
|
|
|
3 |
|
GCR3P-G |
|
|
|
|
|
|
|
GCR3P-S(H) |
|
|
|
|
|
Section |
|
GBF1P-S(H), |
7.2 |
0.55 |
115, 60, 1 |
5-15p |
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
GBSF1P-S(H), |
|
|
|
|
|
1 |
|
GCF1P-S(H) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Freezers |
Section2 |
|
GBF2P-S(H), |
10.0 |
0.68 |
115, 60, 1 |
5-15p |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
GBSF2P-S(H), |
|
|
|
|
|
|
|
GCF2P-S(H) |
|
|
|
|
|
|
|
|
|
|
|
|
|
Section |
|
GBF3P-S(H), |
14.7 |
0.55 |
115, 60, 1 |
5-20P |
|
|
|
(x2) |
|
|
||
|
|
|
|
|
|
||
|
|
|
GBSF3P-S(H), |
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
|
GCF3P-S(H) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Energy Use For Energy Star® Certified Units
|
|
Models |
Energy Use |
|
|
|
|
in kWh |
|
|
Section |
GBR1P-G, GBSR1P-G, GCR1P-G |
2.08 |
|
|
|
|
||
|
GBR1P-S, GBSR1P-S, GCR1P-S |
1.85 |
||
|
|
GBR1P-GH, GBSR1P-GH, GCR1P-GH |
1.66 |
|
|
1 |
|
|
|
Refrigerators |
GBR1P-SH, GBSR1P-SH, GCR1P-SH |
1.70 |
||
|
||||
|
|
|
||
Section2 |
GBR2P-G, GBSR2P-G, GCR2P-G |
3.18 |
||
|
|
|||
|
|
|
|
|
|
|
GBR2P-GH, GBSR2P-GH, GCR2P-GH |
2.91 |
|
|
|
|
|
|
|
|
GBR2P-S, GBSR2P-S, GCR2P-S |
2.71 |
|
|
|
|
|
|
|
|
GBR2P-SH, GBSR2P-SH, GCR2P-SH |
2.49 |
|
|
|
|
|
|
|
Section3 |
GBR3P-G,GBSR3P-G, GCR3P-G |
4.92 |
|
|
|
|
||
|
GBR3P-SH, GBSR3P-SH, GCR3P-SH |
3.54 |
||
|
|
GBR3P-S, GBSR3P-S, GCR3P-S |
3.59 |
|
|
|
|
|
10 |
Part Number: 9294839 11/17 |