Delfield F5PR48D Owner’s Manual

F5 and F15 Series
Refrigerated Display Cases
Original Instructions Installation, Operation and Maintenance Manual
This manual is updated as new information and models are released. Visit our website for the latest manual.
Part Number: 9291460 11/17
Safety Notices
n
Read this manual thoroughly before operating, installing or performing maintenance on the equipment. Failure to follow instructions in this manual can cause property damage, injury or death.
DANGER
Do not install or operate equipment that has been misused, abused, neglected, damaged, or altered/ modified from that of original manufactured specifications.
DANGER
Keep power cord AWAY from HEATED surfaces. DO NOT immerse power cord or plug in water. DO NOT let power cord hang over edge of table or counter.
DANGER
All utility connections and fixtures must be maintained in accordance with local and national codes.
DANGER
Use appropriate safety equipment during installation and servicing.
n
Do not damage the refrigeration circuit when installing, maintaining or servicing the unit.
n
Authorized service representatives are obligated to follow industry standard safety procedures, including, but not limited to, local/national regulations for disconnection / lock out / tag out procedures for all utilities including electric, gas, water and steam.
n
This product contains chemicals known to the State of California to cause cancer and/or birth defects or other reproductive harm. Operation, installation, and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers, crystalline silica, and/or carbon monoxide. Inhalation of airborne particles of glasswool or ceramic fibers is known to the State of California to cause cancer. Inhalation of carbon monoxide is known to the State of California to cause birth defects or other reproductive harm.
n
Do not use electrical appliances or accessories other than those supplied by the manufacturer.
n
Use caution when handling metal surface edges of all equipment.
n
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision concerning use of the appliance by a person responsible for their safety. Do not allow children to play with this appliance.
Notice
Proper installation, care and maintenance are essential for maximum performance and trouble-free operation of your equipment. Visit our website www. mtwkitchencare.com for manual updates, translations, or contact information for service agents in your area.
n
Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. Never use flammable oil soaked cloths or combustible cleaning solutions, for cleaning.
Section 1 General Information
Section 2 Installation
Section 3 Operation
Table of Contents
Model Numbers .................................................................................................................. 5
Serial Number Information ...............................................................................................5
Warranty Information ........................................................................................................ 5
Regulatory Certifications ..................................................................................................5
Domestic Models ....................................................................................................................................5
Export Models .........................................................................................................................................5
Location ..............................................................................................................................7
Weight of Equipment .........................................................................................................8
Clearance Requirements ....................................................................................................8
Dimensions ......................................................................................................................... 8
F15 Leg & Caster Installation ............................................................................................. 9
Leveling ............................................................................................................................... 9
Stabilizing ........................................................................................................................... 9
Shelf Installation ................................................................................................................9
F5 Counter Installation For 36” & 48” Units ....................................................................10
F5 Counter Installation For 60” & 72” Units ....................................................................11
Electrical Service ..............................................................................................................12
Voltage .................................................................................................................................................... 12
Ground Fault Circuit Interrupter .................................................................................................... 12
Rated Amperages, Horsepower, Voltage & Power Cord Chart ............................................ 12
Drain Connections ............................................................................................................13
Refrigeration ....................................................................................................................13
Remote Option Installation .............................................................................................14
F5 Remote Models .............................................................................................................................. 14
F15 Remote Models ............................................................................................................................ 14
Refrigerated Display Cases ..............................................................................................15
Display Lock Operation ...................................................................................................15
115Volt Power Switch ......................................................................................................16
115Volt Light Switch ........................................................................................................ 16
115Volt Temperature Controls ........................................................................................ 16
Temperature Control & Display ...................................................................................................... 17
115Volt F15 Pressure Control ..........................................................................................18
Changing Display from Fahrenheit to Celsius on ERC112 Control .................................... 19
230-240 Volt Export Operation ....................................................................................... 20
Part Number: 9291460 11/17 3
Section 4 Maintenance
Table of Contents (continued)
General Cleaning ..............................................................................................................21
Interior Cleaning ..............................................................................................................22
Gaskets .................................................................................................................................................... 22
Preventing Blower Coil Corrosion ................................................................................................. 22
Exterior Cleaning..............................................................................................................22
Drain .........................................................................................................................................................22
Cleaning The Condenser Coil...........................................................................................23
Cleaning The Condensate Evaporator ............................................................................23
Remote Models Only .......................................................................................................................... 23
Door Maintenance ............................................................................................................23
Doors With Hinges .............................................................................................................................. 23
Sliding Doors ......................................................................................................................................... 23
4 Part Number: 9291460 11/17
Section 1
General Information
Model Numbers
This manual covers the following refrigerated display cases:
Mirrored Back Pass-thru See-thru
Self-Contained Drop-In
F5MC36DV F5PC36DV F5SC36DV F5MC48DV F5PC48DV F5SC48DV F5MC60DV F5PC60DV F5SC60DV F5MC72DV F5PC72DV F5SC72DV
Self-Contained Serview
F15MC48DV F15PC48DV F15SC48DV F15MC60DV F15PC60DV F15SC60DV F15MC72DV F15PC72DV F15SC72DV
Export Numbers
Mirrored Back Pass-thru See-thru
Export Self-Contained Drop-In
F5MC36D-E F5PC36D-E F5SC36D-E F5MC48D-E F5PC48D-E F5SC48D-E F5MC60D-E F5PC60D-E F5SC60D-E F5MC72D-E F5PC72D-E F5SC72D-E
Export Self-Contained Serview
F15MC48D-E F15PC48D-E F15SC48D-E F15MC60D-E F15PC60D-E F15SC60D-E F15MC72D-E F15PC72D-E F15SC72D-E
Serial Number Information
The serial number is on the identification plate that also includes the model number.
Self-contained F5 series identification plate is located near the condensing unit.
The serial number on all self-contained F15 series units is located behind the compressor housing.
Always have the serial number of your unit available when calling for parts or service.
Warranty Information
Visit www.delfield.com/warranty to:
Register your product for warranty.
Verify warranty information.
View and download a copy of your warranty.
Regulatory Certifications
DOMESTIC MODELS
115Volt models are certified by:
National Sanitation Foundation (NSF)
EXPORT MODELS
Export models are certified by:
Technical Inspection Association
European Conformity
Underwriters Laboratories (UL)
Underwriters Laboratories of Canada (cUL)
National Sanitation Foundation (NSF)
Part Number: 9291460 11/17 5
General Information Section 1
THIS PAGE INTENTIONALLY LEFT BLANK
6 Part Number: 9291460 11/17
Section 2
Installation
DANGER
Installation must comply with all applicable fire and health codes in your jurisdiction.
Location
n
This equipment must be positioned so that the plug is accessible unless other means for disconnection from the power supply (e.g., circuit breaker or disconnect switch) is provided.
n
Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to the electrical conduit or gas lines.
n
To avoid instability the installation area must be capable of supporting the combined weight of the equipment and product. Additionally the equipment must be level side to side and front to back.
The location selected for the equipment must meet the following criteria. If any of these criteria are not met, select another location.
Units are intended for indoor use only.
The location MUST be level, stable and capable of supporting the weight of the equipment.
The location MUST be free from and clear of combustible materials.
Equipment MUST be level both front to back and side to side.
Position the equipment so it will not tip or slide.
Front casters MUST be locked once positioned.
Recommended air temperature is 50° - 100°F (10° - 38°C).
Proper air supply for ventilation is REQUIRED AND CRITICAL for safe and efficient operation.
Do not obstruct the flow of ventilation air. Make sure the air vents of the equipment are not blocked.
Do not install the equipment directly over a drain. Steam rising up out of the drain will adversely affect operation, air circulation, and damage electrical / electronic components.
n
This equipment is intended for indoor use only. Do not install or operate this equipment in outdoor areas.
Part Number: 9291460 11/17 7
Installation Section 2
Weight of Equipment
Model Export Option Weight
Self-Contained Drop-In
F5MC36DV F5MC36D-E 525lbs (238kg)
F5PC36DV F5PC36D-E 541lbs (245kg) F5SC36DV F5SC36D-E 546lbs (248kg)
F5MC48DV F5MC48D-E 590lbs (268kg)
F5PC48DV F5PC48D-E 609lbs (276kg) F5SC48DV F5SC48D-E 614lbs (279kg)
F5MC60DV F5MC60D-E 690lbs (313kg)
F5PC60DV F5PC60D-E 711lbs (323kg) F5SC60DV F5SC60D-E 718lbs (326kg)
F5MC72DV F5MC72D-E 790lbs (358kg)
F5PC72DV F5PC72D-E 815lbs (370kg) F5SC72DV F5SC72D-E 818lbs (371kg)
Self-Contained Serview
F15MC48DV F15MC48D-E 759lbs (344kg)
F15PC48DV F15PC48D-E 807lbs (366kg) F15SC48DV F15SC48D-E 786lbs (357kg)
F15MC60DV F15MC60D-E 949lbs (430kg)
F15PC60DV F15PC60D-E 1009lbs (458kg) F15SC60DV F15SC60D-E 983lbs (446kg)
F15MC72DV F15MC72D-E 1110lbs (503kg)
F15PC72DV F15PC72D-E 1159lbs (526kg) F15SC72DV F15SC72D-E 1140lbs (517kg)
Clearance Requirements
Keep the vents clean and free of obstruction.
Casters or optional legs must be used and not removed.
Dimensions
Model Length Depth Height
Self-Contained Drop-In
F5MC36DV 36” (91cm) 31.5” (80cm) 57” (145cm)
F5PC36DV 36” (91cm) 33.38” (85cm) 57” (145cm) F5SC36DV 36” (91cm) 33.38” (85cm) 57” (145cm)
F5MC48DV 48” (122cm) 31.5” (80cm) 57” (145cm)
F5PC48DV 48” (122cm) 33.38” (85cm) 57” (145cm) F5SC48DV 48” (122cm) 33.38” (85cm) 57” (145cm)
F5MC60DV 60” (152cm) 31.5” (80cm) 57” (145cm)
F5PC60DV 60” (152cm) 33.38” (85cm) 57” (145cm) F5SC60DV 60” (152cm) 33.38” (85cm) 57” (145cm)
F5MC72DV 72” (183cm) 31.5” (80cm) 57” (145cm)
F5PC72DV 72” (183cm) 33.38” (85cm) 57” (145cm) F5SC72DV 72” (183cm) 33.38” (85cm) 57” (145cm)
Self-Contained Serview
F15MC48DV 48” (122cm) 31.5” (80cm) 78” (198cm)
F15PC48DV 48” (122cm) 33.38” (85cm) 78” (198cm) F15SC48DV 48” (122cm) 33.38” (85cm) 78” (198cm)
F15MC60DV 60” (152cm) 31.5” (80cm) 78” (198cm)
F15PC60DV 60” (152cm) 33.38” (85cm) 78” (198cm) F15SC60DV 60” (152cm) 33.38” (85cm) 78” (198cm)
F15MC72DV 72” (183cm) 31.5” (80cm) 78” (198cm)
F15PC72DV 72” (183cm) 33.38” (85cm) 78” (198cm) F15SC72DV 72” (183cm) 33.38” (85cm) 78” (198cm)
Export Self-Contained Drop-In
F5MC36D-E 36” (91cm) 31.5” (80cm) 57.5” (146cm)
F5PC36D-E 36” (91cm) 33.38” (85cm) 57.5” (146cm) F5SC36D-E 36” (91cm) 33.38” (85cm) 57.5” (146cm)
F5MC48D-E 48” (122cm) 31.5” (80cm) 57.5” (146cm)
F5PC48D-E 48” (122cm) 33.38” (85cm) 57.5” (146cm) F5SC48D-E 48” (122cm) 33.38” (85cm) 57.5” (146cm)
F5MC60D-E 60” (152cm) 31.5” (80cm) 57.5” (146cm)
F5PC60D-E 60” (152cm) 33.38” (85cm) 57.5” (146cm) F5SC60D-E 60” (152cm) 33.38” (85cm) 57.5” (146cm)
F5MC72D-E 72” (183cm) 31.5” (80cm) 57.5” (146cm)
F5PC72D-E 72” (183cm) 33.38” (85cm) 57.5” (146cm) F5SC72D-E 72” (183cm) 33.38” (85cm) 57.5” (146cm)
Export Self-Contained Serview
F15MC48D-E 48” (122cm) 31.5” (80cm) 78” (198cm)
F15PC48D-E 48” (122cm) 33.38” (85cm) 78” (198cm) F15SC48D-E 48” (122cm) 33.38” (85cm) 78” (198cm)
F15MC60D-E 60” (152cm) 31.5” (80cm) 78” (198cm)
F15PC60D-E 60” (152cm) 33.38” (85cm) 78” (198cm) F15SC60D-E 60” (152cm) 33.38” (85cm) 78” (198cm)
F15MC72D-E 72” (183cm) 31.5” (80cm) 78” (198cm)
F15PC72D-E 72” (183cm) 33.38” (85cm) 78” (198cm) F15SC72D-E 72” (183cm) 33.38” (85cm) 78” (198cm)
8 Part Number: 9291460 11/17