Please read this manual completely before attempting to install or operate this equipment! Notify carrier of
damage! Inspect all components immediately. See page 2.
Warning
To assure proper operation a 2" airspace must be maintained between the bottom of any cooking equipment
and the top of this unit. Cooking equipment must have a barrier (i.e. bottom, drip pan) between its heat
source and the top of the equipment stand. Failure to comply with this could severely damage the equipment
stand and void all warranties.
IMPORTANT INFORMATION
PLEASE SAVE THESE INSTRUCTIONS!
READ BEFORE USE
July 2010
Page 2
F2000/F17 Series Equipment Stand Service and Installation Manual
Delfield
™
®
ContentsSerial Number Location
Receiving And Inspecting ..........................................................2
Even though most equipment is shipped crated, care should be
taken during unloading so the equipment is not damaged while
being moved into the building.
1. Visually inspect the exterior of the package and skid or
container. Any damage should be noted and reported to the
delivering carrier immediately.
2. If damaged, open and inspect the contents with the carrier.
3. In the event that the exterior is not damaged, yet upon
opening, there is concealed damage to the equipment notify
the carrier. Notification should be made verbally as well as
in written form.
4. Request an inspection by the shipping company of the
damaged equipment. This should be done within 10 days
from receipt of the equipment.
5. Check the lower portion of the unit to be sure legs or casters
are not bent.
6. Also open the compressor compartment housing and
visually inspect the refrigeration package. Be sure lines are
secure and base is still intact.
7. Freight carriers can supply the necessary damage forms
upon request.
8. Retain all crating material until an inspection has been made
or waived.
Uncrating the Equipment
First cut and remove the banding from around the crate. Remove
the front of the crate material, use of some tools will be required.
If the unit is on legs remove the top of the crate as well and lift
the unit off the skid. If the unit is on casters it can be "rolled" off
the skid.
This unit is intended for indoor use only. Be sure the location chosen has
a floor strong enough to support the total weight of the cabinet, cooking
equipment and contents. Reinforce the floor as necessary to provide for
maximum loading, for complete weight chart, please refer to page 7.
Good refrigeration is based on good air circulation inside and out.
Inside cabinet: Do not pack refrigerator so full that air cannot circulate.
Outside cabinet: Be sure that the unit has access to ample air to and from
the unit. If air flow is available to the rear of the unit that will help dissipate
exhaust air. In the event the unit is attached to the wall mount brackets,
it is important that air flow is available to the compressor compartment.
Allow air flow to the bottom of the unit as well, avoid hot corners when
possible. Allowing for the proper air flow and ventilation to the compressor
compartment will extend the life of the compressor as well as ensure proper
operation.
Cooking Equipment: WARNING! To assure proper
operation a 2" airspace must be maintained between
the bottom of any cooking equipment and the top of
this unit. Cooking equipment must have a barrier (i.e.
bottom, drip pan) between its heat source and the top
of the equipment stand. Failure to comply with this
could severely damage the equipment stand and void
all warranties.
Leveling
A level cabinet looks better and will perform better because the drain
pan will drain properly, the doors will line up with the frames properly,
and the cabinet will not be subject to undue strain.
A unit on legs will have an adjustable bullet foot on each leg, adjust
each for a level unit. A unit on casters will not be adjustable. Be sure
the unit is on a level floor, make necessary changes to the floor for
proper level.
Lock all front casters to ensure the stability of the unit.
Wall bracket installation
A wall bracket kit is supplied to secure the equipment stand to an interior
wall. Some models are supplied on optional casters. These units must
also have the wall bracket installed during use.
The wall bracket must be installed properly and the
equipment stand firmly secured to it before using this
unit! Failure to observe this warning may result in
damage to the equipment and/or injury to the operator!
Never use the drawers as steps!
Do not overload the drawers or drop or throw product into the drawer
pans.
To install the wall bracket, follow these instructions:
1.
Place the threaded rod through the front and rear
brackets in the compressor section. Thread the rod into
F2000/F17 Series Equipment Stand Service and Installation Manual
the wall bracket, making sure the longer bracket tabs
are above the height of the unit.
Tighten the rod until the bracket is held snug against the
2.
back of the unit.
Move the unit against the wall at the desired location.
3.
Secure the wall mount bracket to the wall using the top
4.
two holes provided in the bracket tabs exposed above
the unit. The wall material must be capable of supporting
a minimum load of 300 pounds (136 kilograms) in the
vertical direction. All screws must be 1/4" diameter and
be capable of transferring the load from the bracket to
the wall.
Remove the threaded rod from the wall mount bracket
5.
and move the unit away from the wall, leaving the bracket
attached to the wall.
Secure the bracket to the wall using the remaining four
6.
holes.
Move the unit back into place and thread the rod back
7.
into the wall mount bracket.
The unit should now be secured to the wall. Test the
8.
mounting by pulling on the unit and checking that all
screws are tightened and the unit is firmly in place. If
the unit is secured, you may now place other equipment
on top of the stand and use the unit as required.
Never place any equipment on top of this unit without
first installing the wall bracket as shown above and
ensuring that the equipment is securely anchored and
stable.
To remove the unit in order to clean behind it, first
9.
remove any equipment placed on top of the stand.
Then rotate the knob on the threaded rod counterclockwise to loosen and remove the rod from the bracket.
Before removing any cooking equipment
(including cooking oils) from the equipment stand,
allow time for the equipment to cool thoroughly.
Use extreme care in moving cooking equipment.
The threaded rod must be reinstalled and tightened
before returning the unit to service!
Be sure all cooking equipment resting on the equipment
stand is properly anchored. Consult the manufacturer’s
instructions for the cooking equipment to determine
the proper mounting technique. It is the owner’s and
operator’s responsibility to securely anchor cooking
equipment to the equipment stand.
Plumbing
Self-contained equipment stands come standard with a condensate
evaporator. If the condensate evaporator fails, the unit’s drain must
have an outlet to an appropriate drainage area or container.
Moisture collecting from improper drainage can create a
slippery surface on the floor and a hazard to employees.
It is the owner’s and operator’s responsibility to provide
a container or outlet for drainage.
F2000/F17 Series Equipment Stand Service and Installation Manual
Delfield
™
®
Installation — Continued
Electrical connection
Refer to the amperage data on page 3 & 4, the serial tag, your local
code or the National Electrical Code to be sure the unit is connected
to the proper power source. A protected circuit of the correct
voltage and amperage must be run for connection of the line cord,
or permanent connection to the unit.
Operation: Refrigerated Base Equipment Stands
Drawer base equipment stands are designed and pre-set at the
factory to maintain a temperature of 36°F to 40°F (2°C to 4°C). A
solar-powered digital thermometer is located on the front of the
unit to allow monitoring of the drawer housing temperature.
The drawer housing temperature is controlled by a pressure
control located in the machine compartment. Continuous opening
and closing of the drawers will hamper the unit’s ability to maintain
optimum refrigeration temperature. Excess weight on top of the
unit will adversely affect the operation of the drawers.
The cooling coil is coated in epoxy to provide long-lasting service.
However, storing all acidic items, such as peppers and tomatoes
with lids that are sealable and immediately wiping up all spills of
either acid or base items will greatly extend the life of your unit.
The on/off switch must be turned to OFF and the
unit disconnected from the power source whenever
performing service, maintenance functions or
cleaning the refrigerated area.
Under no circumstances is a self-contained unit to
be operated without the louvered panel in place.
Never stand on the unit or its drawers! They are not
designed to hold the weight of an adult, and may
collapse or unit may tip if misused in this manner.
These units use HFC-404A refrigerant and have a
lock-out high pressure limiting device. Under severe
overloading conditions, in the event of a condenser fan
failure or a plugged or blocked condenser, this device
may shut down the refrigeration system.
Operation: Freezer Base Equipment Stands
Freezer base equipment stands are designed and pre-set at the
factory to maintain a temperature of 0°F to -5°F (-18°C to -21°C)
interior cabinet temperature at 100°F (38°C) ambient room
temperature. Self-contained units have a digital thermometer
installed in the removable louver. The digital thermometer for
remote units is located in the removable access panel.
Freezers use a Paragon time clock dial for automatic defrosting of
the evaporator coil. The time clock dial is accessible by removing
the larger plate of the electrical box located behind the removable
louver.
T
o Set Time of Day:
Turn the knob of the Paragon time clock dial in the center of the inner
(2 hour) dial and rotate it in a counter-clockwise direction. This will
rotate the outer dial. Continue turning until the correct time of day
on the outer dial lines up with the time pointer.
CAUTION: There is a risk of electrical shock when
removing of top panel or timer cover. Live electrical
parts may be exposed. Disconnect power supply
before servicing.
Operation of Paragon Timer:
The Paragon timer is preset at the factory to provide four defrosts per
day at 6:00 am, 12:00 pm, 6:00 pm and 12:00 midnight. To defrost
on the factory preset schedule the time must be set. If it is necessary
to change the number of defrosts due to unusual operating conditions
it can be accomplished by placing the pins in the outer dial at the
appropriate time of day that defrost initiation is desired.
the defrost limit control, the defrost control switches to refrigeration
mode.
If for any reason the timer remains in defrost for a period of time
greater than 40 minutes, a back-up defrost termination is also
provided.
This back-up is an integral part of the time clock and is set at the
factory at 40 minutes.
It can be changed in the field as follows: push down and rotate
pointer on inside (2 hour) dial until it is opposite desired time
period (in minutes).
Caution: Even under the most severe operating
conditions, it should not be necessary to set the
back-up time greater than 60 minutes. Consult the
factory if complete de-icing of the coil is not accom-
plished within this time period.
When the defrost control goes into defrost, power to the condensing
unit and evaporator fans is interrupted, and the defrost heater is
energized. The defrost heater warms the evaporator coil thereby
melting all frost accumulated during the previous refrigeration cycle.
Once all frost is eliminated, the temperature of the coil continues to
rise until it reaches 70°F (27°C). When this temperature is sensed by
Factory recommended low-pressure control settings are:
HFC-404A refrigerators: 85# cut-in and 65# cut-out to maintain
approximate interior temperature of 38°F. Differential setting of
20#.
HFC-404A freezers: 32# cut-in and 8# cut-out to maintain
approximate interior temperature of 0°F to 5°F. Differential setting
of 24#.
Pressure control settings are measured in pounds,
not fahrenheit.
Minor adjustments can be made to the pressure
control setting by turning the knob in a clockwise
direction for a colder temperature or counter
clockwise for a warmer temperature. In attempting
to adjust the pressure control, you can do
damage to your unit by accidentally adjusting the
differential. If you are uncertain of this procedure,
we strongly recommend that adjustments be
made by a qualified service agent. Delfield is not
responsible for charges incurred while having the
pressure control adjusted.
F2000/F17 Series Equipment Stand Service and Installation Manual
Thermometer Part #3516059
To calibrate thermometer or change °F to °C follow these steps.
Remove two screws and rear cover plate from thermometer.
1.
Reposition °F/°C switch to desired setting.
2.
Insert probe into an ice water bath. Ensure ice water temp is
3.
at 32°F or 0°C.
Adjust calibration screw to proper display temperature.
F2000/F17 Series Equipment Stand Service and Installation Manual
Delfield
™
®
Maintenance
Door Gasket Maintenance
Door gaskets require regular cleaning to prevent mold and mildew
build up and also to retain the elasticity of the gasket. Gasket
cleaning can be done with the use of warm soapy water. Avoid
full strength cleaning products on gaskets as this can cause them
to become brittle and crack. Never use sharp tools or knives to
scrape or clean the gasket. Gaskets can be easily replaced and do
not require the use of tools or an authorized service person. The
gaskets are “Dart” style and can be pulled out of the groove in the
door and new gaskets can be “pressed” back into place.
Drain Maintenance - Base
Each unit has a drain located inside the unit that removes the
condensation from the evaporator coil and routes it to an external
condensate evaporator pan. Each drain can become loose or
disconnected during normal use. If you notice water accumulation
on the inside of the unit be sure the drain tube is connected to
the evaporator drain pan. If water is collecting underneath the unit
make sure the end of the drain tube is in the condensate evaporator
in the machine compartment. The leveling of the unit is important
as the units are designed to drain properly when level. Be sure all
drain lines are free of obstructions.
Drawer Maintenance
Drawer Assembly Cleaning
The drawer assembly is designed to be cleaned easily. Both drawer
and tracks are removable without tools. The drawer tracks are
dishwasher safe or can be cleaned in a sink with detergents and
a soft bristle brush. Drawers and tracks should be cleaned on a
weekly basis.
Remove Drawers
Pull the drawer box out until it stops. Lift up on the drawer front
and pull the drawer box completely out. Using a soft bristle brush,
clean the track on the bottom of the drawer box. When finished, it
should be wiped clean of all food and debris.
Tracks
The drawer box assembly must be removed. Pull the drawer tracks
out until they hit a stop. Locate blue safety clips towards the back
of each drawer track. Blue safety clips have a tab on the top. Push
the tab back until it clicks. Lift up and pull the drawer tracks all
the way out of the drawer
cage. The drawer tracks
are dishwasher safe or
can be cleaned in a sink
with detergents and a soft
tab on top of
blue safety clip
Using a soft bristle brush, wash the track making sure each roller
is thoroughly cleaned. The drawer cage should be cleaned with
a soft bristle brush, removing any food and debris gathered on
the bottom ledge. Once it’s cleaned thoroughly with a soft bristle
brush, wipe remaining debris clean with a soft towel.
bristle brush. Drawers
and tracks should be
cleaned on a weekly basis.
Reassembly
Push the drawer tracks into the drawer cage. The blue safety clip
must remain pushed towards the back. Lift up and slide the drawer
track all the way into the drawer cage. The blue safety clip will
lock in place automatically. Once all tracks are replaced, insert the
drawer box. Rest the drawer box bottom track on the front track
roller. Then push the drawer back in place SLOWLY. When the
drawer box is about half way in you will hit a STOP. You must lift
the front of the drawer up approximately ½” (1.3cm) to continue
inward. Clean tracks as often as possible. The cleaner the tracks
are the better they will operate.
Caster Maintenance
Wipe casters with a damp cloth monthly to prevent corrosion.
The power switch must be turned to OFF and the
unit disconnected from the power source whenever
performing service, maintenance functions or cleaning
the refrigerated area.
Refrigerators and Freezers
The interior and exterior can be cleaned using soap and warm water.
If this isn’t sufficient, try ammonia and water or a nonabrasive
liquid cleaner. When cleaning the exterior, always rub with the
“grain” of the stainless steel to avoid marring the finish. Do not
use an abrasive cleaner because it will scratch the stainless steel
and can damage the breaker strips and gaskets.
Stainless Steel Care and Cleaning
To prevent discoloration or rust on stainless steel several important
steps need to be taken. First, we need to understand the properties
of stainless steel. Stainless steel contains 70- 80% iron, which will
rust. It also contains 12-30% chromium, which forms an invisible
passive film over the steel’s surface, which acts as a shield against
corrosion. As long as the protective layer is intact, the metal is still
stainless. If the film is broken or contaminated, outside elements
can begin to breakdown the steel and begin to form discoloration
or rust. Proper cleaning of stainless steel requires soft cloths or
plastic scouring pads.
NEVER USE STEEL PADS, WIRE BRUSHES OR SCRAPERS!
Cleaning solutions need to be alkaline based or non-chloride
cleaners. Any cleaner containing chlorides will damage the
protective film of the stainless steel. Chlorides are also commonly
found in hard water, salts, and household and industrial cleaners. If
cleaners containing chlorides are used be sure to rinse repeatedly
and dry thoroughly. Routine cleaning of stainless steel can be done
with soap and water. Extreme stains or grease should be cleaned
with a non-abrasive cleaner and plastic scrub pad. Always rub with
the grain of the steel. There are stainless steel cleaners available
which can restore and preserve the finish of the steels protective
layer. Early signs of stainless steel breakdown are small pits and
cracks. If this has begun, clean thoroughly and start to apply
stainless steel cleaners in attempt to restore the passivity of the
steel.
Never use an acid based cleaning solution! Many food
products have an acidic content, which can deteriorate
the finish. Be sure to clean the stainless steel surfaces
of ALL food products. Common items include, tomatoes,
peppers and other vegetables.
Cleaning the Condenser Coil
In order to maintain proper refrigeration performance, the
condenser fins must be cleaned of dust, dirt and grease regularly.
It is recommended that this be done at least every three months.
If conditions are such that the condenser is totally blocked in three
months, the frequency of cleaning should be increased. Clean the
condenser with a vacuum cleaner or stiff brush. If extremely dirty,
a commercially available condenser cleaner may be required.
Failure to maintain a clean condenser coil can initially cause high
temperatures and excessive run times. Continuous operation with
a dirty or clogged condenser coil can result in compressor failure.
Neglecting the condenser coil cleaning procedures will void any
warranties associated with the compressor and cost to replace the
compressor.
F2000/F17 Series Equipment Stand Service and Installation Manual
Never use a high-pressure water wash for this
cleaning procedure as water can damage the electrical
components located near or at the condenser coil.
Preventing blower coil corrosion
To help prevent corrosion of the blower coil, store all acidic items,
such as pickles and tomatoes, in sealable containers. Immediately
wipe up all spills.
Units with pans should be operated with pans in place.
Operating the unit without all pans in place will lower
efficiency and may damage the unit.
Cleaning the condensate evaporator (remote models only)
The stainless steel condensate evaporator pan should be cleaned
every six months. Use a vacuum cleaner or damp cloth to remove
dust that may have accumulated. This will prevent corrosion of the
stainless steel.
Over shelves and other items mounted to the top of the counters
should never be installed in the field due to the potential damage
to the refrigeration system.
1030-262-0000Side, evaporator
23516173Guard, fan
3030-260-0000Top, evaporator
4030-259-0000Front, enclosure
53516172Blade, fan
63516271Valve, expansion, 1/2hp, R404a
72194046Control, limit, fan delay/defrost
8031-264-0000Bracket, fan motor
92162691Motor, fan, 115V
F2000/F17 Series Equipment Stand Service and Installation Manual
Delfield
™
®
Standard Labor Guidelines To Repair Or Replace Parts On Delfield Equipment
Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage.
• A maximum of 1-hour is allowed to diagnose a defective component.
• A maximum of 1-hour is allowed for retrieval of parts not in stock.
• A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed.
• Overtime, installation/start-up, normal control adjustments, general maintenance, glass breakage, freight damage, and/or
correcting and end-user installation error will not be reimbursed under warranty unless pre-approved with a Service Work
Authorization from Delfield. You must submit the number with the service claim.
Labor Of 1 Hour Is Allowed To Replace:
• Compressor Start Components and Overload Protector • Condensate Element
• Defrost Timer • Door Hinges, Locks, and Gaskets
• Drawer Tracks/Cartridges • Evaporator/Condenser Fan Motor and Blade
• Fan Delay/Defrost Termination Switch • Hi-limit/Thermal Protector Switch
• Solenoid Coil • Thermostat
• Thermometer • Transformer
Labor Of 2 Hours To Replace:
• Defrost Element • Locate/Repair Leak
• Pressure Control • Solenoid Valve
Labor Of 3 Hours To Replace:
• Condenser or Evaporator Coil • Expansion Valve
Labor Of 4 Hours To Replace:
• Compressor
This includes recovery of refrigerant and leak check.
$55.00 maximum reimbursement for refrigerant recovery (includes recovery machine, pump, torch, oil, flux, minor fittings,
solder, brazing rod, nitrogen, or similar fees.)
Refrigerant:
• R404A A maximum of $15.00/lb. or $1.00/oz. will be reimbursed.
F2000/F17 Series Equipment Stand Service and Installation Manual
Delfield
™
®
Standard Limited Warranty -
The Delfield Company (“Delfield”) warrants to the Original Purchaser
of the Delfield product (herein called the “Unit”) that such Unit,
and all parts thereof, will be free from defects in material and
workmanship under normal use and service for a period of one (1)
year from the date of shipment of the Unit to the Original Purchaser
or, if the Original Purchaser returns the warranty card completely
filled out including the date of installation within thirty (30) days
of receipt of the Unit, one (1) year from the date of installation.
During this one year warranty period, Delfield will repair or replace
any defective part or portion there of returned to Delfield by the
Original Purchaser which Delfield determines was defective due to
faulty material or workmanship. The Original purchaser will pay all
labor, crating, freight and related costs incurred in the removal of
the Unit of defective component and shipment to Delfield, except
that during a period of either ninety (90) days from the date of
shipment of the Unit to the Original Purchaser or, if the Original
Purchaser returns the warranty card completely filled out including
the date of installation within thirty (30) days of receipt of the Unit,
ninety (90) days from the date of installation Delfield will pay all
related labor costs. Delfield will pay the return costs if the Unit or
part thereof was defective.
The term “Original Purchaser” as used herein means that person,
firm, association, or corporation for whom the Unit was originally
installed.
This warranty does not apply to any Unit or part thereof that has
been subjected to misuse, neglect, alteration, or accident, such as
accidental damage to the exterior finish, operated contrary to the
recommendations specified by Delfield; or repaired or altered by
anyone other than Delfield in any way so as to, in Delfield’s sole
judgement, affect its quality or efficiency. This warranty does not
apply to any Unit that has been moved from the location where
it was originally installed. This warranty also does not cover the
refrigerator drier or the light bulbs used in the Unit. The warranty
is subject to the user’s normal maintenance and care responsibility
as set forth in the Service and Installation Manual, such as cleaning
the condenser coil, and is in lieu of all other obligations of Delfield.
Delfield neither assumes, nor authorizes any other person to
assume for Delfield, any other liability in connection with Delfield’s
products.
Removal or defacement of the original Serial Number or Model
Number from any Unit shall be deemed to release Delfield from
all obligations hereunder or any other obligations, express or
implied.
Parts furnished by suppliers to Delfield are guaranteed by
Delfield only to the extent of the original manufacturer’s express
warranty to Delfield. Failure of the Original Purchaser to receive
such manufacturers warranty shall in no way create any warranty,
expressed or implied, or any other obligation or liability on Delfield’s
part in respect thereof.
One year parts, 90 days labor
If shipment of a replacement part is requested prior to the arrival in
the Delfield factory of the part claimed to be defective, the Original
Purchaser must accept delivery of the replacement part on a C.O.D.
basis, with credit being issued after the part has been received and
inspected at Delfield’s plant and determined by Delfield to be within
this warranty.
Under no condition does this warranty give the Original Purchaser
the right to replace the defective Unit with a complete Unit of the
same manufacturer or of another make. Unless authorized by
Delfield in writing, this warranty does not permit the replacement
of any part, including the motor-compressor, to be made with the
part of another make or manufacturer.
No claims can be made under this warranty for spoilage of any
products for any reason, including system failure.
The installation contractor shall be responsible for building access,
entrance and field conditions to insure sufficient clearance to allow
any hood(s), vent(s), or Unit(s) if necessary, to be brought into the
building. Delfield will not be responsible for structural changes or
damages incurred during installation of the Unit or any exhaust
system.
Delfield shall not be liable in any manner for any default or delay
in performance hereunder caused by or resulting from any
contingency beyond Delfield’s control, including, but not limited
to, war, governmental restrictions or restraints, strike, lockouts,
injunctions, fire, flood, acts of nature, short or reduced supply of
raw materials, or discontinuance of the parts by the original part
manufacturer.
Except as provided in any Additional Four Year Protection Plan,
if applicable, and the Service Labor Contract, if applicable, the
foregoing is exclusive and in lieu of all other warranties, whether
written or oral, express or implied. This warranty supersedes
and excludes any prior oral or written representations or
warranties. Delfield expressly disclaims any implied warranties
of merchantability, fitness for a particular purpose, or compliance
with any law, treaty, rule or regulation relating to the discharge of
substances into the environment. The sole and exclusive remedies
of any person relating to the Unit, and the full liability of Delfield for
any breach of this warranty, will be as provided in this warranty.
Other than this Delfield Standard One Year Limited Warranty,
any applicable Delfield Additional Four Year Protection Plan or
applicable Delfield Service Labor Contract, the Original Purchaser
agrees and acknowledges that no other warranties are offered
or provided in connection with or for the Unit or any other part
thereof.
In no event will Delfield be liable for special, incidental or
consequential damages, or for damages in the nature of
penalties.
F2000/F17 Series Equipment Stand Service and Installation Manual
Delfield
™
®
Additional Four Year Protection Plan -
In addition to the Standard One Year Warranty on the MotorCompressor contained in the above listed Delfield product (the
“Unit”), The Delfield Company (“Delfield”) also agrees to repair,
or exchange with similar or interchangeable parts in design and
capacity at Delfield’s option, the defective Motor-Compressor contained in the Unit (the “Motor-Compressor), or any part thereof, for
the Original Purchaser only, at any time during the four (4) years
following the initial one (1) year period commencing on the date
of installation for the Original Purchaser. Failure of the Original
Purchaser to register the registration card containing the Original
Purchasers name, address, date of installation, model number and
serial number of the Unit containing the Motor-Compressor within
30 days from the date of installation shall void this warranty. This
additional warranty is only available if the Motor-Compressor is
inoperative due to defects in material or factory workmanship, as
determined by Delfield in its sole judgement and discretion. The
Original Purchaser shall be responsible for returning the defective Motor-Compressor to Delfield prepaid, F.O.B. at the address
shown on the back cover of this manual.
The term “Original Purchaser” as used herein means that person,
firm, association, or corporation for whom the Unit was originally
installed.
The term “Motor-Compressor” as used herein does not include
unit base, air or water cooled condenser, receiver, electrical accessories such as relay, capacitors, refrigerant controls, or condenser
fan/motor assembly. This warranty does not cover labor charges
incidental to the replacement of parts. This warranty further
does not include any equipment to which said condensing unit is
connected, such as cooling coils, temperature controls or refrigerant metering devices. This warranty shall be void if the MotorCompressor, in Delfield’s sole judgement, has been subjected to
misuse, neglect, alteration or accident, operated contrary to the
recommendations specified by the Unit manufacturer, repaired or
altered by anyone other than Delfield in any way so as, in Delfield’s
sole judgment, to affect its quality or efficiency or if the serial
number has been altered, defaced or removed. This Warranty
does not apply to a Motor-Compressor in any Unit that has been
moved from the location where it was originally installed. The
addition of methyl chloride to the condensing unit or refrigeration
system shall void this warranty.
For motor compressor only.
General Conditions
Delfield shall not be liable in any manner for any default or delay
in performance hereunder caused by or resulting from any contingency beyond Delfield’s control, including, but not limited to, war,
governmental restrictions or restraints, strike, lockouts, injunctions, fire, flood, acts of nature, short or reduced supply of raw
materials, or discontinuance of any part or the Motor-Compressor
by the unit manufacturer.
Replacement of a defective Motor-Compressor is limited to one (1)
Motor-Compressor by us during the four (4) year period. Delfield
shall replace the Motor-Compressor at no charge.
This warranty does not give the Original Purchaser of the MotorCompressor the right to purchase a complete replacement MotorCompressor of the same make or of another make. It further does
not permit the replacement to be made with a Motor-Compressor
of another kind unless authorized by Delfield. In the event Delfield
authorizes the Original Purchaser to purchase a replacement
Motor-Compressor locally, only the wholesale cost of the MotorCompressor is refundable.
Expressly excluded from this warranty are damages resulting from
spoilage of goods.
Except as provided in any applicable Standard One Year Limited
Warranty or applicable Service Labor Contract, the foregoing is
exclusive and in lieu of all other warranties, whether written or
oral, express or implied. This Warranty supersedes and excludes
any prior oral or written representations or warranties. Delfield
expressly disclaims any implied warranties of merchantability, fitness for a particular purpose or compliance with any law, treaty,
rule or regulation relating to the Motor-Compressor, and the full
liability of Delfield for any breach of this warranty, will be as provided in this warranty.
Other than any applicable Delfield Standard One year Limited Warranty, this Delfield Additional Four Year Protection Plan and any
applicable Delfield Service Labor Contract, the Original Purchaser
agrees and acknowledges that no other warranties are offered or
provided in connection with or for the Motor-Compressor or any
part thereof.
22
In no event will Delfield be liable for special, incidental or consequential damages, or for damages in the nature of penalties.
F2000/F17 Series Equipment Stand Service and Installation Manual
Delfield
™
®
Drawer Warranty -
The Delfield Company (“Delfield”) warrants to the Original
Purchaser of the Delfield drawer system (herein called the “Unit”)
that such Unit, and all parts thereof, will be free from defects in
material and workmanship under normal use and service for a
period of one (1) year from the date of shipment of the Unit to the
Original Purchaser or, if the Original Purchaser returns the warranty card completely filled out including the date of installation
within thirty (30) days of receipt of the Unit, one (1) year from the
date of installation. In addition, Delfield warrants the left and right
intermediate track deemed the “Roller track assembly” profiles,
this is the part that contains all the Delrin rollers for ten years.
These are the only parts falling under the 10 year warranty. During
this one year warranty period, Delfield will repair or replace any
defective part or portion thereof returned to Delfield by the Original
Purchaser which Delfield determines was defective due to faulty
material or workmanship. The Original Purchaser will pay all
labor, crating, freight and related costs incurred in the removal of
the Unit or defective component and shipment to Delfield, except
that during a period of either ninety (90) days from the date of
shipment of the Unit to the Original Purchaser or, if the Original
Purchaser returns the warranty card completely filled out including the date of installation within thirty (30) days of receipt of the
Unit, ninety (90) days from the date of installation Delfield will pay
all related labor costs. Delfield will pay the return costs if the Unit
or part thereof was defective.
One/ Ten Year Parts * 90 Day labor
If shipment of a replacement part is requested prior to the arrival
in the Delfield factory of the part claimed to be defective, Delfield
will send a UPS call tag to the customer to receive damaged or
defective parts back for inspection. Delfield must receive the parts
back to redeem warranty coverage from Fulterer. It is also very
important to receive these parts to determine if any future change
to the design is needed.
Under no condition does this Warranty give the Original Purchaser
the right to replace the defective Unit with a complete Unit of the
same manufacturer or of another make. Unless authorized by
Delfield in writing, this Warranty does not permit the replacement
of any part to be made with the part of another make or manufacturer.
No claims can be made under this Warranty for spoilage of products for any reason, including system failure.
Delfield shall not be liable in any manner for any default or delay
in performance hereunder caused by or resulting from any contingency beyond Delfield’s control, including, but not limited to,
war, governmental restrictions or restraints, strikes, lockouts,
injunctions, fire, floods, acts of nature, short or reduced supply of
raw materials, or discontinuance of the parts by the original part
manufacturer.
The term “Original Purchaser” as used herein means that person,
firm, association, or corporation for whom the Unit was originally
installed.
This Warranty does not apply to any Unit or part hereof that has
been subjected to misuse, neglect, alteration, or accident, such as
accidental damage to the exterior finish; operated contrary to the
recommendations specified by Delfield; or repaired or altered by
anyone other than Delfield in any way so as to, in Delfield’s sole
judgment, affect its quality or efficiency. This Warranty does not
apply to any Unit that has been moved from the location where it
was originally installed. The warranty is subject to the user’s normal maintenance and care responsibility as set forth in the Service
and Installation Manual. Delfield neither assumes, nor authorizes
any other person to assume for Delfield, any other liability in connection with Delfield’s products.
Removal or defacement of the original Serial Number or Model
Number from any Unit shall be deemed to release Delfield from
all obligations hereunder or any other obligations, express or
implied.
Parts furnished by suppliers to Delfield are guaranteed by Delfield
only to the extent of the original manufacturer’s express warranty
to Delfield. Failure of the Original Purchaser to receive such manufacturer’s warranty shall in no way create any warranty, express
or implied, or any other obligation or liability on Delfield’s part in
respect thereof.
Except as provided in any Additional Four Year Protection Plan,
if applicable, and the Service Labor Contract, if applicable,
the foregoing is exclusive and in lieu of all other warranties,
whether written or oral, express or implied. This Warranty
supersedes and excludes any prior oral or written representations
or warranties. Delfield expressly disclaims any implied warranties
of merchantability, fitness for a particular purpose or compliance
with any law, treaty, rule or regulation relating to the discharge
of substances into the environment. The sole and exclusive
remedies of any person relating to the Unit, and the full liability
of Delfield for any breach of this Warranty, will be as provided in
this Warranty.
Other than this Delfield Standard One Year Limited Warranty,
any applicable Delfield Additional Four Year Protection Plan or
applicable Delfield Service Labor Contract, the Original Purchaser
agrees and acknowledges that no other warranties are offered or
provided in connection with or for the Unit or any part thereof.
In no event will Delfield be liable for special, incidental or
consequential damages, or for damages in the nature of
penalties.