Delfield N8118B, N8130B, N8156B, N8169B, N8181B Service Manual

...
Page 1
Delfield
N8000, N8000-R, N8100B, N8100-BR, N8100-FA, 8100-EF, N8200, N8200G, N8600, N8700-D, N8700-R, N8800 Drop Ins
Service, Installation and Care Manual
Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately.
®
Hot Food Wells, Cold Pans, Granite Cold Slabs,
Frost Tops and Hot/Cold Food Wells
IMPORTANT INFORMATION
READ BEFORE USE
January 2012
Page 2
N8000 Series Drop-In Installation and Operation Manual
Delfield
Important Warning And Safety Information
WARNING Read This Manual Thoroughly Before Operating, Installing, Or Performing
Maintenance On The Equipment.
WARNING Failure To Follow Instructions In This Manual Can Cause Property Damage,
Injury Or Death.
WARNING Do Not Store Or Use Gasoline Or Other Flammable Vapors Or Liquids In The
Vicinity Of This Or Any Other Appliance.
WARNING Unless All Cover And Access Panels Are In Place And Properly Secured, Do
Not Operate This Equipment.
WARNING Do Not Clean With Water Jet.
CAUTION Observe the following:
• Minimum clearances must be maintained from all walls and combustible materials.
• Keep the equipment area free and clear of combustible material.
• Adequate clearance for air openings.
• Operate equipment only on the type of electricity indicated on the
specification plate.
• Retain this manual for future reference.
2
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
®
Page 3
N8000 Series Drop-In Installation and Operation Manual
Delfield
Contents Serial Number Location
Receiving And Inspecting Unit .................................................... 3
Specifications ......................................................................... 4-7
Installation
Curved Drop-In Cutout Details .................................................. 8
N8000, N8000N, N8000-R, N8100B, N8100NB, N8100-BR, N8200,
N8200G, 8100-FA, 8100-EF Series ............................................ 9
N8600 Series ........................................................................... 9
N8700-D, N8700N, N8700-R & N8800 Series ........................... 10
Operation
N8100B, N8100NB, N8100-BR ................................................ 11
N8100-FA .............................................................................. 11
8100-EF ................................................................................ 12
N8200 & N8200G ................................................................... 12
N8600 ................................................................................... 13
N8700-D, N8700N, N8700-R & N8800 Series ........................... 14
Maintenance ............................................................................ 15
Unit Assembly N8100-FA .......................................................... 16
Wiring Diagram
N8100-FA .............................................................................. 16
N8100B, N8100NB & N8100-BR .............................................. 17
8100-EF & 8100-EFN .............................................................. 17
N8200 & N8200G ................................................................... 17
N8600 .............................................................................. 18-19
N8800 ................................................................................... 19
N8700-D, N8700N & N8700-R ................................................ 20
Louver Diagram ....................................................................... 21
Miscellaneous Replacement Parts ............................................. 21
N8100-FA Replacement Parts List ............................................. 22
Condensing Unit Assembly Parts List ................................... 23-26
Food Well Assembly Parts List ............................................. 27-28
Standard Labor Guidelines ........................................................ 29
Standard Warranties ........................................................... 30-31
The serial number on self-contained refrigerated units is on the electrical specications tag located near the condensing unit.
The serial number on remote refrigerated units is on the outside bottom of the food well.
On hot food pans and hot/cold combination pans, the serial number tag is located on the back of the control raceway or remote panel.
The serial number tag also lists the refrigerant used and the amount of charge.
Always have the serial number of your unit available when calling for parts or service.
This manual covers only standard 8000 series units. If you have a custom designed unit, you should contact our parts/service department at (800) 733-8829 for questions.
©2012 The Deleld Company. All rights reserved. Reproduction without written permission is prohibited. “Deleld” is a registered trademark of The Deleld Company.
Receiving And Inspecting The Equipment
Even though most equipment is shipped crated, care should be taken during unloading so the equipment is not damaged while being moved into the building.
1. Visually inspect the exterior of the package and skid or container. Any damage should be noted and reported to the delivering carrier immediately.
2. If damaged, open and inspect the contents with the carrier.
3. In the event that the exterior is not damaged, yet upon opening, there is concealed damage to the equipment notify the carrier. Notication should be made verbally as well as in written form.
4. Request an inspection by the shipping company of the damaged equipment. This should be done within 10 days from receipt of the equipment.
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
5. Also open the compressor compartment housing and visually inspect the refrigeration package. Be sure lines are secure and base is still intact.
6. Freight carriers can supply the necessary damage forms upon request.
7. Retain all crating material until an inspection has been made or waived.
Uncrating The Equipment
First cut and remove the banding from around the crate. Remove the front of the crate material, use of some tools will be required.
3
Page 4
N8000 Series Drop-In Installation and Operation Manual
Delfield
Specifications
N8100B Series Self-Contained Mechanically Cooled Pans - R134A
Model
N8118B
N8130B
N8143B
N8156B
N8169B
N8181B
L D H
18” (45.7cm)
30.75” (78.1cm)
43.5” (110.5cm)
56.25” (142.9cm)
69” (175.3cm)
81.75” (208cm)
26” (66cm)
26” (66cm)
26” (66cm)
26” (66cm)
26” (66cm)
26” (66cm)
21.87” (55.5cm)
21.87” (55.5cm)
21.87” (55.5cm)
21.87” (55.5cm)
21.87” (55.5cm)
21.87” (55.5cm)
Counter Cutout Dimensions V/Hz/Ph Amps H.P. BTU
17” X 25” (43.2cm x 63.5cm)
29.75” x 25” (75.6cm x 63.5cm)
42.50” X 25” (108.6cm x 63.5cm)
55.25” x 25” (140.3cm x 63.5cm)
68” X 25” (172.7cm x 63.5cm)
80.75” x 25” (205.1cm x 63.5cm)
115/60/1
115/60/1 4.0 1/5 379
115/60/1
115/60/1 7.0 1/4 758
115/60/1 7.0 1/4 948
115/60/1 8.0 1/3 1138
4.0 1/5 204
4.0 1/5 569
N8100NB Series Self-Contained Mechanically Cooled Pans Narrow Style - R134A
N8146NB
N8168NB
46.75” (118.7cm)
67.5” (171.5cm)
18” (45.7cm)
18” (45.7cm)
21.81” (55.4cm)
21.81” (55.4cm)
45.75” x 17” (113.7cm x 43.2cm)
66.5” x 17” (168.9cm x 43.2cm)
115/60/1 4.0 1/5 454 17/40º/-5º 680 175lbs
115/60/1 4.0 1/5 676 26/31º/4º 804 240lbs
Evap BTU/ TD/TEMP
19/38º/-3º
26/31º/4°
35/26º/9º
43/32º/3º
51/29º/6º
59/32º/3º
Sys Cap
708 100lbs
812 140lbs
889 173lbs
1373 205lbs
1469 225lbs
1921 258lbs
Ship Weight
(45kg)
(64kg)
(78kg)
(93kg)
(102kg)
(117kg)
(80kg)
(109kg)
Refrig.
NEMA
Charge
Plug
5-15P
8.0oz
8.0oz 5-15P 2
5-15P
8.0oz
16.0oz 5-15P 4
16.0oz 5-15P 5
11.5oz 5-15P 6
5-15P
8.0oz
8.0oz 5-15P 3
12”x20” Pans
1
3
2
N8100BR Series Curved Self-Contained Mechanically Cooled Pans - R134A
Model
N8144-BR
N8159-BR
N8176-BR
N8194-BR
L D H
40.43” (103cm)
57.22” (145cm)
73.68” (187cm)
89.86” (228cm)
26.05” (66cm)
26.05” (66cm)
26.05” (66cm)
26.05” (66cm)
21.81” (55cm)
21.81” (55cm)
21.81” (55cm)
21.81” (55cm)
Counter Cutout Dimensions V/Hz/Ph Amps H.P. BTU
see drawing on page 8
see drawing on page 8
see drawing on page 8
see drawing on page 8
115/60/1 4.0 1/5 379
115/60/1
115/60/1 7.0 1/4 758
115/60/1 7.0 1/4 948
4.0 1/5 569
Evap BTU/ TD/TEMP
26/31º/4°
35/26º/9º
43/32º/3º
51/29º/6º
N8100-FA Series Forced Air Drop-In Mechanically Cooled Cold Pans - R404A
Model L D H
N8131-FA
N8144-FA
N8157-FA
N8169-FA
N8182-FA
31.25” (79.4cm)
44” (111.8cm)
56.75” (144.1cm)
69.5” (176.5cm)
82.25” (208.9cm)
26.67” (67.7cm)
26.67” (67.7cm)
26.67” (67.7cm)
26.67” (67.7cm)
26.67” (67.7cm)
26.62” (68cm)
26.62” (68cm)
26.62” (68cm)
28.62” (72.7cm)
28.62” (72.7cm)
Counter Cutout Dimensions V/Hz/Ph Amps H.P. BTU
30.25” x 25.5” (76.8cm x 64.8cm)
43” x 25.5”
109.2cm x 64.8cm)
55.75” x 25.5” (141.6cm x 64.8cm)
68.5” x 25.5”
174.0cm x 64.8cm)
81.25” x 25.5”
206.4cm x 64.8cm)
115/60/1 7.8 1/4 1339 140/15º/20
115/60/1 9.2 1/2 2035 140/22º/13
115/60/1 9.2 1/2 2731 280/14º/21° 3806
115/60/1 14.8 3/4
115/60/1 14.8 3/4 4070 280/20º/15° 5545
Evap BTU/ TD/TEMP
º
º
3374 280/20º/15° 5545
Sys
Ship
Cap
Weight
812 161lbs
(72kg)
889 184lbs
(83kg)
1373 233lbs
(105kg)
1469 243lbs
(109kg)
Sys
Ship
Cap
Weight
168lbs
2154
(76kg)
175lbs
3142
(79kg)
225lbs (102kg)
235lbs (107kg)
406lbs (184kg)
Refrig.
NEMA
Charge
Plug
8.0oz 5-15P 2
5-15P
8.0oz
16.0oz 5-15P 4
16.0oz 5-15P 5
Refrig.
NEMA
Charge
Plug
16.0oz 5-15P 2
32.0oz 5-15P 3
32.0oz 5-15P 4
48.0oz 5-20P 5
48.0oz 5-20P 6
12”x20” Pans
3
12”x20” Pans
4
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
®
Page 5
N8000 Series Drop-In Installation and Operation Manual
Delfield
Specifications
8100-EF Series LiquiTec® Eutetic Fluid Refrigerated Cold Pans - R404A
Model L D H
8118-EF
8132-EF
8145-EF
8159-EF
8172-EF
8186-EF
18.20” (46.2cm)
31.76” (80.7cm)
45.32” (115.1cm)
58.88” (149.6cm)
72.44” (184cm)
86” (218.4cm)
26” (66cm)
26” (66cm)
26” (66cm)
26” (66cm)
26” (66cm)
26” (66cm)
23.25” (59.1cm)
23.25” (59.1cm)
23.25” (59.1cm)
23.25” (59.1cm)
23.25” (59.1cm)
23.25” (59.1cm)
Counter Cutout Dimensions V/Hz/Ph Amps H.P.
17” x 25” (43.2cm x 63.5cm)
30.75” x 25” (78.1cm x 63.5cm)
44.25” x 25” (112.4cm x 63.5cm)
57.87” x 25” (147cm x 63.5cm)
71.5” x 25” (181.6cm x 63.5cm)
85” x 25” (215.9cm x 63.5cm)
115/60/1 7.5 1/4 204 19/50º/-15° 928 169lbs
115/60/1 7.5 1/4 379 26/42º/-7° 1112 215lbs
115/60/1 7.5 1/4 569 35/36º/-1° 1259 265lbs
115/60/1 7.5 1/4 758 43/32º/3° 1373 285lbs
115/60/1 7.5 1/4 948 51/29º/6° 1469 295lbs
115/60/1 7.5 1/4 1138 59/26º/9° 1529 394lbs
8100-EFN Series LiquiTec® Slim Line Eutetic Fluid Refrigerated Cold Pans - R404A
Model L D H
8148-EFN
8169-EFN
8191-EFN
47.66” (121.1cm)
69.22” (175.8cm)
90.78” (230.6cm)
18” (45.7cm)
18” (45.7cm)
18” (45.7cm)
23.25” (59.1cm)
23.25” (59.1cm)
23.25” (59.1cm)
Counter Cutout Dimensions V/Hz/Ph Amps H.P.
46.88” x 17.25” (119.1cm x 43.8cm)
68.5” x 17.25” (174cm x 43.8cm)
90” x 17.25” (228.6cm x 43.8cm)
115/60/1 7.5 1/4 379 26/42º/-7° 1112 235lbs
115/60/1 7.5 1/4 569 35/36º/-1° 1259 285lbs
115/60/1 7.5 1/4 758 43/32º/13° 1373 295lbs
BTU Load
BTU Load
Evap BTU/ TD/TEMP
Evap BTU/ TD/TEMP
Sys Cap
Sys Cap
Ship Weight
(77kg)
(98kg)
(120kg)
(130kg)
(134kg)
(179kg)
Ship Weight
(107kg)
(130kg)
(134kg)
Refrig.
NEMA
Charge
Plug
24.0oz 5-15P 1
24.0oz 5-15P 2
24.0oz 5-15P 3
24.0oz 5-15P 4
24.0oz 5-15P 5
24.0oz 5-15P 6
Refrig.
NEMA
Charge
Plug
24.0oz 5-15P 2
24.0oz 5-15P 3
24.0oz 5-15P 4
12x20 Pans
12x20 Pans
N8000 Series Ice Cooled Cold Pans
Model
N8018
N8030
N8043
N8056
N8069
N8081
L D H
18” (45.7cm)
30.75” (78.1cm)
43.5” (110.5cm)
56.25” (142.9cm)
69” (175.3cm)
81.75” (208cm)
26” (66cm)
26” (66cm)
26” (66cm)
26” (66cm)
26” (66cm)
26” (66cm)
10.75” (27.3cm)
10.75” (27.3cm)
10.75” (27.3cm)
10.75” (27.3cm)
10.75” (27.3cm)
10.75” (27.3cm)
Counter Cutout Dimensions
17” x 25” (43.2cm x 63.5cm)
29.75” x 25” (75.6cm x 63.5cm)
42.5” x 25” (107.9cm x 63.5cm)
55.25” x 25” (140.3cm x 63.5cm)
68” x 25” (172.7cm x 63.5cm)
80.75” x 25” (205.1cm x 63.5cm)
N8000N Series Narrow Ice Cooled Cold Pans
N8046N
N8068N
46.75” (118.8cm)
67.5” (171.5cm)
18” (45.7cm)
18” (45.7cm)
10.75” (27.3cm)
10.75” (27.3cm)
45.75” x 17” (116.2cm x 43.2cm)
66.50” x 17” (168.9cm x 43.2cm)
Ship Weight
38lbs (17kg)
84lbs (38kg)
110lbs (50kg)
139lbs (63kg)
160lbs (73kg)
197lbs (89kg)
100lbs (45kg)
120lbs (55kg)
12”x20” Pans Held
1
2
3
4
5
6
2
3
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
5
Page 6
N8000 Series Drop-In Installation and Operation Manual
Delfield
Specifications
N8000-R Series Curved Ice Cooled Cold Pans
Model
N8044-R
N8059-R
N8076-R
N8094-R
L D H
40.48” (103cm)
57.22” (145cm)
73.68” (187cm)
89.89” (228cm)
26.05” (66cm)
26.05” (66cm)
26.05” (66cm)
26.05” (66cm)
10.77” (27cm)
10.77” (27cm)
10.77” (27cm)
10.77” (27cm)
Counter Cutout Dimensions
see drawing on page 8 100lbs
see drawing on page 8 118lbs
see drawing on page 8 145lbs
see drawing on page 8 164lbs
N8200 Series Self-Contained Frost Tops - R404A
Model
N8231
N8245
N8259
N8273
N8287
L D H
31.75" (80.6cm)
45.63” (115.9cm)
59.5” (151.1cm)
73.38" (186.4cm)
87.25" (221.6cm)
26” (66cm)
26” (66cm)
26” (66cm)
26” (66cm)
26” (66cm)
15.75” (40cm)
15.75” (40cm)
15.75” (40cm)
15.75” (40cm)
15.75” (40cm)
Counter Cutout Dimensions V/Hz/Ph Amps H.P. BTU
30.75” x 25" (78.1cm x 63.5cm)
44.63” x 25” (113.3cm x 63.5cm)
58.50” x 25” (148.6cm x 63.5cm)
72.38” x 25” (183.8cm x 63.5cm)
86.25" x 25" (219.1cm x 63.5cm)
Ship Weight
(45kg)
(53kg)
(65kg)
(74kg)
115/60/1 7.5 1/4
115/60/1 7.5 1/4
115/60/1 7.5 1/4
115/60/1 8.0 1/4
115/60/1 8.0 1/3
12”x20” Pans Held
2
3
4
5
Evap BTU/ TD/TEMP
379 26/42º/-7° 1112
569 35/36º/-1° 1259
758 43/32º/3° 1373
948 51/29º/6° 1469
1138 59/30º/5° 1787
Sys Cap Ship Weight
142lbs (64kg)
168lbs (76kg)
193lbs (88kg)
209lbs (95kg)
239lbs (108kg)
Refrig. Charge
24.0oz
24.0oz
24.0oz
24.0oz
24.0oz
NEMA Plug
5-15P
5-15P
5-15P
5-15P
5-15P
N8200G Series Self-Contained Granite Cold Slabs
Model
N8231G
N8245G
N8259G
N8273G
L D H
31.75” (80.6cm)
45.63” (115.9cm)
59.5” (151.1cm)
73.38” (186.4cm)
25.87” (65.7cm)
25.87” (65.7cm)
25.87” (65.7cm)
25.87” (65.7cm)
19” (48.3cm)
19” (48.3cm)
19” (48.3cm)
19” (48.3cm)
Counter Cutout Dimensions V/Hz/Ph Amps H.P. BTU
30.75” X 25” (78.1cm x 63.5cm)
44.63” x 25” (113.4cm x 63.5cm)
58.5” x 25” (148.6cm x 63.5cm)
72.38” x 25” (183.8cm x 63.5cm)
115/60/1 7.5 1/4
115/60/1 7.5 1/4
115/60/1 8.0 1/3
115/60/1 9.0 1/2
Evap BTU/ TD/TEMP
379 26/42º/-7° 1112
569 35/36º/-1° 1259
758 43/37º/-2° 1572
948 51/43º/-8° 2183
N8600 Series Self Contained Combination Hot/Cold Food Wells - R404A
Model
N8630
N8643
N8656
N8669
N8681
L D H
30.75” (78.1cm)
43.5” (110.5cm)
56.25” (142.9cm)
69” (175.3cm)
81.75” (207.6cm)
26” (66cm)
26” (66cm)
26” (66cm)
26” (66cm)
26” (66cm)
23.75” (60.3cm)
23.75” (60.3cm)
23.75” (60.3cm)
23.75” (60.3cm)
23.75” (60.3cm)
Counter Cutout Dimensions
29.75” X 25” (75.5cm x 63.5cm)
42.50” x 25” (107.9cm x 63.5cm)
55.25” x 25” (140.3cm x 63.5cm)
68” x 25” (172.7cm x 63.5cm)
80.75” x 25” (205.1cm x 63.5cm)
Control Panel Cutout Dimensions
12.25” x 4.25” x 7.00” (31.1cm x 10.8cm x 17.8cm)
12.25” x 4.25” x 7.00” (31.1cm x 10.8cm x 17.8cm)
12.25” x 4.25” x 7.00” (31.1cm x 10.8cm x 17.8cm)
12.25” x 4.25” x 7.00” (31.1cm x 10.8cm x 17.8cm)
12.25” x 4.25” x 7.00” (31.1cm x 10.8cm x 17.8cm)
V/Hz/Ph Amps H.P. BTU
120/60/1 24.0 1/4
120/240 /60/1
120/240 /60/1
120/240 /60/1
120/240 /60/1
21.0 1/4
21.0 1/4
42.0 1/4
42.0 1/3
Sys Cap Ship Weight
219lbs (99kg)
284lbs (129kg)
338lbs (153kg)
425lbs (193kg)
Evap BTU/TDSys
Cap
379 26/42º/-7° 1112
569 35/36º/-1° 1259
758 43/32º/3° 1373
948 51/29º/6° 1469
1138 59/30º/5° 1787
Refrig. Charge
24.0oz
24.0oz
24.0oz
32.0oz
Ship Weight
164lbs (74kg)
198lbs (90kg)
233lbs (106kg)
266lbs (121kg)
301lbs (137kg)
NEMA Plug
5-15P
5-15P
5-15P
5-15P
Refrig. Charge
16.0oz 2
16.0oz 3
16.0oz 4
16.0oz 5
24.0oz 6
12”x20”
Pans
6
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
®
Page 7
N8000 Series Drop-In Installation and Operation Manual
Delfield
Specifications
N8700D Series Individually Controlled Heated Food Wells
Model
N8717-D
N8731-D
N8745-D
N8759-D
N8773-D
N8787-D
L D H
17.88” (45.4cm)
31.75” (80.6cm)
45.63” (115.9cm)
59.5” (151.1cm)
73.38” (186.4cm)
87.25” (221.4cm)
26” (66cm)
26” (66cm)
26” (66cm)
26” (66cm)
26” (66cm)
26” (66cm)
9.5” (24cm)*
9.5” (24cm)*
9.5” (24cm)*
9.5” (24cm)*
9.5” (24cm)*
9.5” (24cm)*
Counter Cutout Dimensions
16.88” X 25” (42.8cm x 63.5cm)
30.75” x 25” (78.1cm x 63.5cm)
44.62” x 25” (113.3cm x 63.5cm)
58.5” x 25” (148.6cm x 63.5cm)
72.37” x 25” (183.8cm x 63.5cm)
86.25” x 25” (219.1cm x 63.5cm)
*14” Overall height including drain connection
N8700-R Series Curved Individually Controlled Heated Food Wells
Model
N8744-R
N8759-R
N8776-R
N8794-R
L D H
40.48” (103cm)
57.22” (145cm)
73.68” (187cm)
89.80” (228cm)
26.05” (66cm)
26.05” (66cm)
26.00” (66cm)
25.91” (66cm)
9.5” (24cm)*
9.5” (24cm)*
9.5” (24cm)*
9.5” (24cm)*
*14” Overall height including drain connection
Counter Cutout Dimensions
see drawing on page 8 10.31” x 4.62” x 7.00”
see drawing on page 8 14.5” x 4.62” x 7.00”
see drawing on page 8 18.69” x 4.62” x 7.00”
see drawing on page 8 22.88” x 4.62” x 7.00”
Control Panel Cutout Dimensions
7.00” x 4.62” x 7.00” (17.8cm x 11.7cm x 17.8cm)
10.31” x 4.62” x 7.00” (26.2cm x 11.7cm x 17.8cm)
14.5” x 4.62” x 7.00” (36.8cm x 11.7cm x 17.8cm)
18.69” x 4.62” x 7.00” (47.5cm x 11.7cm x 17.8cm)
22.88” x 4.62” x 7.00” (58.1cm x 11.7cm x 17.8cm)
27” x 4.62” x 7.00” (68.6cm x 11.7cm x 17.8cm)
Control Panel Cutout Dimensions
(26cm x 12cm x 18cm)
(37cm x 12cm x 18cm)
(47cm x 12cm x 18cm)
(58cm x 12cm x 18cm)
V/Hz/Ph Amps
120/60/1 8.3 41lbs
120/60/1 16.6 99lbs
208-230 /60/1
208-230 /60/1
208-230 /60/1
208-230 /60/1
V/Hz/Ph Amps
120/60/1 16.6 99lbs
208-230 /60/1
208-230 /60/1
208-230 /60/1
Ship Weight
(19kg)
(45kg)
15.0/16.0 134lbs (61kg)
20.0/22.0 166lbs (75kg)
24.0/27.0 186lbs (84kg)
29.0/32.0 236lbs (107kg)
Ship Weight
(45kg)
15.0/16.0 134lbs (61kg)
20.0/22.0 166lbs (75kg)
24.0/27.0 186lbs (84kg)
12”x20” Pans
1
2
3
4
5
6
12”x20” Pans
2
3
4
5
N8700N Series Individually Controlled Heated Narrow Food Wells
Model
N8746N N8746ND
N8768N N8768ND
L D H
45.61” (116cm)
67.48” (172cm)
15.87” (40cm)
15.87” (40cm)
9.5” (24cm)
9.5” (24cm)
*ND Models are standard with drains
Counter Cutout Dimensions
44.62” x 15.0” (113.3cm x 38.1cm)
66.50” x 15.0” (168.9cm x 38.1cm)
Control Panel Cutout Dimen­sions
10.31” x 4.62” x 7.00” (26.2cm x 11.7cm x 17.8cm)
14.50” x 4.62” x 7.00” (36.8cm x 11.7cm x 17.8cm)
V/Hz/Ph Amps
120/60/1 17.0 100lbs
208-230 /60/1
N8800 Series Single Tank Electric Hot Food Wells
Model
N8831
N8845
N8859
N8873
N8887
L D H
31.75” (80.6cm)
45.63” (115.9cm)
59.5” (151.1cm)
73.38” (186.4cm)
87.25” (221.6cm)
26” (66cm)
26” (66cm)
26” (66cm)
26” (66cm)
26” (66cm)
®
11” (27.9cm)
11” (27.9cm)
11” (27.9cm)
11” (27.9cm)
11” (27.9cm)
Counter Cutout Dimensions
30.75” X 25” (78.1cm x
63.5
44.63” x 25” (113.4cm x
63.5
58.5” x 25” (148.6cm x
63.5
72.38” x 25” (183.8cm x
63.5
86.25” x 25” (219.1cm x
63.5
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
Control Panel Cutout Dimen­sions
12.25” x 4.25” x 7.00”
cm)
(31.1cm x 10.8cm x 17.8cm)
12.25” x 4.25” x 7.00”
cm)
(31.1cm x 10.8cm x 17.8cm)
12.25” x 4.25” x 7.00”
cm)
(31.1cm x 10.8cm x 17.8cm)
12.25” x 4.25” x 7.00”
cm)
(31.1cm x 10.8cm x 17.8cm)
12.25” x 4.25” x 7.00”
cm)
(31.1cm x 10.8cm x 17.8cm)
V/Hz/Ph Amps
120/60/1 17.0 100lbs
208-230 /60/1
208-230 /60/1
208-230 /60/1
208-230 /60/1
Ship Weight
(45kg)
15.0/16.0 130lbs (59kg)
Ship Weight
(45kg)
15.0/16.0 136lbs (62kg)
20.0/22.0 158lbs (72kg)
24.0/27.0 195lbs (88kg)
29.0/32.0 224lbs (102kg)
12”x20” Pans
2
3
12”x20” Pans
2
3
4
5
6
7
Page 8
N8000 Series Drop-In Installation and Operation Manual
Delfield
Curved Drop-In Cutout Details
2 pan standard curved drop-in cutout detail Models:
• N8044-R
• N8144-BR
• N8744-R
85˚
19.75” 50cm
172.50˚
19.75” 50cm
85˚
25.10” 64cm
95˚
3 pan standard curved drop-in cutout detail Models:
• N8059-R
• N8159-BR
• N8759-R
25.10” 64cm
85˚
4 pan standard curved drop-in cutout detail Models:
• N8076-R
• N8176-BR
• N8776-R
25.10” 64cm
85˚
19.56” 50cm
19.56” 50cm
95˚
95˚
25.00” 64cm
15.92” 40cm
25.00” 64cm
15.73” 40cm
25.00” 64cm
15.73” 40cm
172.50˚
172.50˚
172.50˚
25.00” 64cm
15.92” 40cm
17.06” 43cm
13.78” 35cm
17.06” 43cm
25.00” 64cm
25.00” 64cm
13.78” 35cm
95˚
172.50˚
172.50˚
25.10” 64cm
15.73” 40cm
13.78” 35cm
25.00” 64cm
17.06” 43cm
25.00” 64cm
19.56” 50cm
95˚
85˚
172.50˚
25.10” 64cm
15.73” 40cm
25.00” 64cm
19.56” 50cm
95˚
85˚
25.10” 64cm
5 pan standard curved drop-in cutout detail Models:
• N8094-R
• N8194-BR
• N8794-R
8
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
25.10” 64cm
172.50˚
17.06” 43cm
25.00” 64cm
13.78” 35cm
172.50˚
13.78” 35cm
17.06” 43cm
25.00” 64cm
172.50˚
15.67” 40cm
25.00” 64cm
95˚
19.50” 50cm
85˚
25.10” 64cm
®
17.06”
172.50˚
43cm
25.00” 64cm
13.78” 35cm
19.50” 50cm
85˚
25.00” 64cm
95˚
15.67” 40cm
Page 9
N8000 Series Drop-In Installation and Operation Manual
Delfield
CAUTION
DANGER
DANGER
Installation N8000, N8000N, N8000-R, N8100B, N8100NB, N8100-BR, N8200, N8200G, N8100-FA & 8100-EF
These units are intended for indoor use only. A room temperature of no more than 86°F (30°C) is recommended. Be sure the location chosen has a counter strong enough to support the total weight of the unit and contents. A fully loaded model may weigh as much as 600 pounds! Reinforce the counter as necessary to provide maximum loading.
Unit requires that the sides and bottom are not any closer than 3” (7.6cm) to any combustible material.
The counter cut-out sizes and power requirements are shown on the specication pages. A gasket is installed in the ange of each unit. The weight of the unit on the gasket forms a seal preventing liquids from seeping into the cut-out opening.
Louvers
Self-contained refrigerated units (N8100, N8100NB, N8100-BR, N8200 and N8200G Series) require airow to the compressor. A 13” x 25” (33 cm x 63.5 cm) louver is provided by Deleld and must be installed in the counter in front of the condenser. The louver cutout dimension is 11” x 22” (27.9 cm x 55.9 cm). The rear must have an opening to permit removal of heated air. The opening must be at least 8” x 11”, a total of 88 square inches (20.3 cm x 27.9 cm, a total of 566 square centimeters).
Plumbing
The units drain must have an outlet to an appropriate drainage area or container. A drain trap must be installed. N8200 series have 1/2” drain and N8200G series have 3/4” drain located on end/center. The 1” diameter drain on N8000, N8000-R, N8100, N8100NB, N8100-BR, N8100-FA and 8100-EF Series units is shipped loose and must be connected during installation. N8157-FA, N8169-FA, and N8182-FA have two drains.
Electrical connection
Refer to the amperage data on the specication pages, the serial tag or your local code to be sure the unit is connected to the proper power source. A protected circuit of the correct voltage and amperage must be run for con nec tion of the line cord.
Some units have an ON/OFF switch located behind the louvered panel in the machine compartment. Simply turn the switch to ON to begin operation.
Some units have an OFF position on the thermostat dial which is located behind the louvered panel in the machine compartment. Simply turn the dial to begin operation.
Moisture collecting from improper drainage can create a slippery surface on the oor and a hazard to employees. It is the owner’s responsibility to provide a container or outlet for drainage.
Some N8000, N8000N, N8000-R, N8100B,
N8100NB and N8100-BR may have polyethylene insulation in the drain hole. This can easily be cut out without any contact or damage to the units interior insulation or refrigeration lines.
The unit must be disconnected from the power source whenever performing service
or maintenance functions.
Never operate the unit without the louvered
panel in place!
Installation N8600
These units are intended for indoor use only. A room temperature of no more than 86°F (30°C) is recommended. Be sure the location chosen has a counter strong enough to support the total weight of the unit and contents. A fully loaded model may weigh as much as 600 pounds! Reinforce the counter as necessary to provide for maximum loading.
Unit requires that the sides and bottom are not any closer than 3” (7.6cm) to any combustible material.
The counter cut-out sizes and power requirements are shown on the specication pages. A gasket is installed in the ange of each unit. The weight of the unit on the gasket forms a seal preventing liquids from seeping into the cut-out opening.
The cut-out dimensions for the control box on N8600 Series units is 4.25” x 12.25” (10.8 cm x 31.1 cm).
Louvers
For proper refrigerated operation, N8600 Series units require airow to the compressor. A 13” x 25” louver is (33.0 cm x 63.5 cm) is provided by Deleld and must be installed in the counter in front of the condenser. The louver cutout dimension is 11”
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
x 22” (27.9 cm x 55.9 cm). The rear must have an opening to permit removal of heated air. The opening must be at least 8” x 11”, a total of 88 square inches (20.3 cm x 27.9 cm, a total of 566 square centimeters).
Plumbing
The units 1” (2.54cm) drain must have an outlet to an appropriate drainage area or container.
Moisture collecting from improper drainage can create a slippery surface on the oor and a hazard to employees. It is the owner’s
CAUTION
responsibility to provide a container or outlet for drainage.
Electrical connection
Refer to the amperage data on the specication pages, the serial tag or your local code to be sure the unit is connected to the proper power source.
The unit must be disconnected from the
power source whenever performing service
or maintenance functions.
Never operate the unit without the louvered
panel in place!
9
Page 10
N8000 Series Drop-In Installation and Operation Manual
Delfield
CAUTION
DANGER
Installation N8700-D, N8700N, N8700-R & N8800 Series
These units are intended for indoor use only. Be sure the location chosen has a counter strong enough to support the total weight of the unit and contents. A fully loaded model may weigh as much as 600 pounds! Reinforce the counter as necessary to provide maximum loading.
Plumbing N8700-D, N8700N-D and N8700-R Plumbing: Unit is equipped
with 1/2” (1.3cm) drains, (one per well located in right rear corner 1/2” (1.3cm) female N.P.T.) manifold and 1/2” (1.3cm) gate valve.
Unit requires that the sides and bottom are not any closer than 3” (7.6cm) to any combustible material.
The counter cut-out sizes and power requirements are shown on the specication pages. A gasket is installed in the ange of each unit. The weight of the unit on the gasket forms a seal preventing liquids from seeping into the cut-out opening.
N8700 Series pans should be installed with the drains at the back, away from the operator’s sides.
The controls on N8700-D, N8700-R and N8800 series units are mounted in a control panel, designed to be installed at a “remote” location. The control panel should be installed so that the indicator light for each control is to the right of the control. N8700, N8700N and N8700-R series units have 48” (121.9cm) of conduit and N8800 Series units have 24” (61.0cm) of conduit between the pans and the remote control panel to facilitate this installation.
N8800 Plumbing: Well is sloped to a 1.00” (2.5cm) male N.P.T. stainless steel drain.
Moisture collecting from improper drainage can create a slippery surface on the oor and a hazard to employees. It is the owner’s responsibility to provide a container or outlet for drainage.
Electrical connection
Refer to the amperage data on the specication pages, the serial tag or your local code to be sure the unit is connected to the proper power source.
The unit must be disconnected from the power source whenever performing service or maintenance functions.
Control Panel Installation, N8700-D, N8700N & N8700-R Series
The control panel is designed to be installed on the side opposite the drains.
If you choose to install the control panel on the same side as the drains the control panel will either be upside down or the knobs will control the opposite wells.
10
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
Control panel installed opposite drains
Drains
®
Page 11
Delfield
Operation N8100B, N8100NB & N8100-BR
Ruby Tuesday Salad Bar Service and Installation Manual
DEFROST TIMER
18648-BUC
. . . . . . . . . . . . . . . . . . . . . . .
16 oz.
18660-BUC
. . . . . . . . . . . . . . . . . . . . . . .
16 oz.
18672-BUC
16 oz.
18691-BUC
. . . . . . . . . . . . . . . . . . . . . . .
16 oz.
18699-BUC
24 oz.
186114-BUC
24 oz.
55# cut-in and 30# cut-out to maintain
82# cut-in and 57# cut-out to maintain
N8100 Series mechanically cooled cold pans are adjusted at the factory to provide proper operation without any further adjustments. However, if it is necessary to adjust the temperature, the control is located in the machine compartment. Turn the knob clockwise as indicated on the control. Settings are from 1 thru 7 (7 being the coldest). Adjustments should be made gradually. Several small adjustments will be more effective than one large adjustment. It may take an hour or longer to realize the temperature change depending on the application and location of the unit.
These units are not designed to cool warm food products. Items should be placed in the unit pre-cooled at least to the desired holding temperature, if not slightly colder. In some applications, a gradual warming of product may occur, particularly at the exposed top of the product. Stirring or rotation of the product may be necessary to maintain overall temperature.
N8000 Series Drop-In Installation and Operation Manual
Warming of food product can occur very quickly outside of the unit. When loading or rotating product, avoid leaving food items in a non-refrigerated location for any length of time to prevent warming or spoilage.
The temperature control is used to turn the unit on and off as well as control the temperature of the cold pan. The settings range from 1 through 7 (7 being the coldest). To turn the cold pan off, turn the knob to the OFF position.
If the cold pan is to be used with ice, it is recommended that the optional perforated bottoms be used. These will allow ice to melt properly.
The unit must be turned off when not in use or overnight for defrosting and cleaning.
Operation N8100-FA
N8100-FA Series forced air mechanically cooled cold pans come equipped with 115-volt, 60 Hertz, single phase refrigeration units. The refrigeration valves are open and ready to operate as soon as the power supply cord is plugged into the standard 115-volt, grounded electrical outlet.
Pressure Control
The temperature is controlled by an adjustable pressure control located in the machine compartment and adjustable control has the word COLDER near the knob, with an arrow to indicate the adjustment direction. This control is eld adjustable and does not require a service agent. If you have any questions, feel free to contact the Deleld Service Department at (800) 733-8829.
In attempting to adjust the pressure control, you can do damage to the unit by accidentally adjusting the differential. Deleld is not responsible for charges incurred while adjusting the pressure control.
Food in the N8100-FA pans should not be loaded in such a way as to interfere with the air curtain owing over the cold pans.
Defrost Timer
Every 2 hours for 15 minutes.
30 psi (207 kPa) dierential 80 psi (552 kPa) cut-in 50 psi (345 kPa) cut-out
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
11
Page 12
N8000 Series Drop-In Installation and Operation Manual
Delfield
Operation 8100-EF Series
There is a switch on the compressor housing front to turn the 8100-EF units on and off. 8100-EF Series LiquiTec uid cold pans are adjusted at the factory to provide proper operation without any further adjustments. However, if it is necessary to adjust the temperature, the control is located in the machine compartment. Turn the knob clockwise as indicated on the control to adjust it colder. Adjustments should be made gradually. Several small adjustments will be more effective than one large adjustment. It may take an hour or longer to realize the temperature change depending on the application and location of the unit.
These units are not designed to cool warm food products. Items should be placed in the unit pre-cooled at least to the desired holding temperature, if not slightly colder. In some applications, a gradual warming of product may occur, particularly at the exposed top of the product. Stirring or rotation of the product may be necessary to maintain overall temperature. Warming of food product can occur very quickly outside of the unit. When loading or rotating the product, avoid leaving food items in a non-refrigerated location for any length of time to prevent warming or spoilage.
The cold pan is not intended to be used with ice.
®
Eutetic
The unit must be turned off when not in use or overnight for defrosting and cleaning.
Temperature Control Settings: 17°F (8ºC) differential 25°F (-4ºC) cut-in 8°F (-13ºC)cut-out
Operation N8200
N8200 Series frost tops are designed to maintain an even layer of frost to pleasantly display product. Once turned on, the compressor will run continuously. The unit should be turned off overnight or when not in use. There is no temperature control on the N8200 series. The ON/OFF switch is the only means available to cycle the unit.
Operation N8200G
N8200G Series granite cold slabs are designed to maintain a low temperature surface for quick turn products such as ice cream. Frost patterns will vary depending on room conditions such as temperature, humidity and airow. The “work zone” of the granite surface is considered to be inside a 2” (5.1cm) perimeter. Temperatures in the perimeter zone may be higher and again the frost patterns in this area will vary based on room conditions.
Since it takes time for the frost to accumulate initially, the unit should be turned on approximately one hour before it is actually required. Product should not be placed on the frost top prior to turning the unit on, because it may freeze to the surface of the unit.
The unit must be turned off when not in use or overnight for defrosting and cleaning.
Unit is controlled by an on/off switch. Once turned on, the unit will run continuously. There is no temperature control in this unit. Turn the unit on approximately two hours prior to use to allow for ample cool down time. The unit must be turned off when not in use or overnight for defrosting and cleaning.
12
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
®
Page 13
Delfield
DARNGE
STPE S
Operation N8600 Hot/Cold Series
Hot Operation
N8600 Series hot and cold combination pans must be operated with water in the well for proper hot operation. Fill well with a minimum of 4” (10.2cm) of water. Place function switch in HOT position to begin heating. Turn thermostat dial to the desired temperature.
Never use anything other than plain water in the wells or tank. Failure to observe this warning may result in personal injury or damage to the unit.
When operated at the highest temperature setting, the top of the unit will become very hot. Staff and customers using the equipment should be informed about this.
To turn unit off, simply move the function switch to OFF position. Drain water and allow unit to cool before cleaning or switching to cold operation.
Cold Operation
Simply place the function switch to the COLD position. The compressor controller has been factory set and no temperature adjustment should be necessary. If the cold pan is to be used with ice, it is recommended that the optional perforated bottoms be used. These will allow ice to melt properly.
N8000 Series Drop-In Installation and Operation Manual
Switching from hot to cold operation
Follow this procedure:
1. Place the function switch in the OFF position and drain out hot water.
2. Allow the unit to cool until it can be safely cleaned.
3. When clean up procedures are complete, unit will be ready for cold operation. This takes about one hour.
To assure maximum compressor life, do not switch from “hot” to “cold” operation without allowing a cool down period. Never switch from hot to cold operation while hot water remains in the pans. Failure to observe this warning will greatly reduce compressor life and eventually cause premature compressor failure.
Switching from cold to hot operation
No special procedure is required to switch from the cold to hot operation. Be certain to ll will with a minimum of 4” of water.
The unit is designed so that the compressor and the heating elements cannot operate at the same time. Continued operation of the compressor in the “hot position” should not
be considered normal. Call for service if this happens.
N8600 Immersion Heater Reset Switch
As a safety feature the N8600 food well immersion heater has a reset switch. If the heater gets too hot, it will turn off. Low or no water can be the cause.
The unit must be turned off when you push the manual reset switch.
Access Hole for N8600 Immersion Heater Reset Switch
The unit must be turned off when not in use or overnight for defrosting and cleaning.
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
13
Page 14
N8000 Series Drop-In Installation and Operation Manual
Delfield
DARNGE
DARNGE
DARNGE
Operation N8700-D, N8700N, N8700-R & N8800 Series
These units are designed to hold warm food product between 140ºF to 160ºF (60ºC to 71ºC).
N8700-D, N8700N and N8700-R series individually heated hot food units may be operated “wet” (with water in the wells) or “dry”. However, “wet” operation is recommended for better performance.
N8800 Series single tank hot food units are designed to be operated “wet” (with water in the tank) only.
Proper water level (approximately 2” [5.1cm]) must be maintained to prevent damage to the tank on the N8800 Series units.
After the unit is hard wired to the electrical system, select desired temperature by rotating temperature control. A knob and indicator light are provided for each individual heated food well.
First Time Use
Before the unit is used the rst time for serving, turn the temperature knob to “HI” and heat the well for 20 to 30 minutes.
Any residue or dust that adhered to the heater element(s) will be burned off during this initial preheat period.
When serving thick sauces always use the hot food well in “wet” operation. This provides more uniform temperature for the sauce.
Never place food directly in well. Always use pans.
For most efficient operation, keep covered inserts in each well during preheating or when empty.
Always place covers on pans when not serving to prevent food from drying out.
Wet Operation
Fill the food well with a minimum of 2” (5.1cm) of water and cover with lid or empty pan. To preheat water, set temperature control at “HI”. With pans in place, wells will boil water. Food temperature will vary depending on type and amount of product. To minimize steam and water usage, set control at lowest setting that will maintain proper food temperature. To reduce preheating time, use hot water to ll the well.
When operating these units “wet,” never use anything other than plain water in the wells or tank. Failure to observe this warning may result in personal injury or damage to the unit.
When operated at the highest temperature setting, the top of the unit will become very hot. Staff and customers using the equipment should be informed about this.
Steam can cause serious burns. Always use some type of protective covering on your hands and arms when removing lids from the unit. Lift the lid in a way that will direct escaping steam away from your face and body.
Dry Operation N8700 Series only
Wet operation is usually much more efficient and is preferred. However, these units may be operated without water with no damage to the unit.
When operated dry, the bottom of the well will discolor. To clean, use a stainless steel cleaner or mild abrasive.
The dry well should never be preheated longer
than 15 minutes.
When operated dry, the well bottoms become
very hot. Do not allow unprotected skin to
contact any well surface.
14
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
®
Page 15
Delfield
Maintenance
N8000 Series Drop-In Installation and Operation Manual
Drain Maintenance - N8100-FA Series
Each unit has a drain located inside the unit that removes the condensation from the evaporator coil and routes it to an external condensate evaporator pan. Each drain can become loose or disconnected during normal use. If you notice water accumulation on the inside of the unit be sure the drain tube is connected to the evaporator drain pan. If water is collecting underneath the unit make sure the end of the drain tube is in the condensate evaporator in the machine compartment. The leveling of the unit is important as the units are designed to drain properly when level. Be sure all drain lines are free of obstructions.
The power switch must be turned to OFF and
the unit disconnected from the power source whenever performing service, maintenance
functions or cleaning the refrigerated area.
Stainless Steel Care and Cleaning
To prevent discoloration or rust on stainless steel several important steps need to be taken. First, we need to understand the properties of stainless steel. Stainless steel contains 70- 80% iron, which will rust. It also contains 12-30% chromium, which forms an invisible passive lm over the steel’s surface, which acts as a shield against corrosion. As long as the protective layer is intact, the metal is still stainless. If the lm is broken or contaminated, outside elements can begin to breakdown the steel and begin to form discoloration or rust. Proper cleaning of stainless steel requires soft cloths or plastic scouring pads.
Cleaning the Condenser Coil
In order to maintain proper refrigeration performance, the condenser ns must be cleaned of dust, dirt and grease regularly. It is recommended that this be done at least every three months. If conditions are such that the condenser is totally blocked in three months, the frequency of cleaning should be increased. Clean the condenser with a vacuum cleaner or stiff brush. If extremely dirty, a commercially available condenser cleaner may be required.
Failure to maintain a clean condenser coil can initially cause high temperatures and excessive run times. Continuous operation with a dirty or clogged condenser coil can result in compressor failure. Neglecting the condenser coil cleaning procedures will void any warranties associated with the compressor and cost to replace the compressor.
Never use a high-pressure water wash for this cleaning procedure as water can damage the electrical components located near or at the
CAUTION
condenser coil.
NEVER USE STEEL PADS, WIRE BRUSHES OR SCRAPERS!
Cleaning solutions need to be alkaline based or non-chloride cleaners. Any cleaner containing chlorides will damage the protective lm of the stainless steel. Chlorides are also commonly found in hard water, salts, and household and industrial cleaners. If cleaners containing chlorides are used be sure to rinse repeatedly and dry thoroughly. Routine cleaning of stainless steel can be done with soap and water. Extreme stains or grease should be cleaned with a non-abrasive cleaner and plastic scrub pad. Always rub with the grain of the steel. There are stainless steel cleaners available which can restore and preserve the nish of the steels protective layer. Early signs of stainless steel breakdown are small pits and cracks. If this has begun, clean thoroughly and start to apply stainless steel cleaners in attempt to restore the passivity of the steel.
Never use an acid based cleaning solution! Many food products have an acidic content, which can deteriorate the nish. Be sure to clean
CAUTION
the stainless steel surfaces of ALL food products. Common items include, tomatoes, peppers and other vegetables.
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
15
Page 16
N8000 Series Drop-In Installation and Operation Manual
Delfield
MODELS - NORDIC BREEZE
Unit Assembly N8100-FA
UPRIGHT AIR DIFFUSER WITH AIR DEFLECTOR
BLACK AIRFLOW EXTRUSIONS
PERFORATED PAN CLIP
ADAPTER BARS
COIL ASSY COVER
PLEXIGLAS END CAPS
Wiring Diagram N8100-FA
L1
1
2
35
DEFROST TIMER
PRESSURE CONTROL
CONDENSING UNIT
N
G
16
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
COOLING FANS
®
Page 17
Delfield
Wiring Diagram N8100B, N8100NB & N8100-BR
L1
COOLING T'STAT
N
G
Wiring Diagram 8100-EF, 8100-EFN
N8000 Series Drop-In Installation and Operation Manual
CONDENSER FAN
S
C
R
COMPRESSOR
115V
ON/OFF SWITCH
L1
COOLING T'STAT
N
G
Wiring Diagram N8200 & N8200G
ON/OFF SWITCH
L1
N
G
CONDENSER FAN
C
COMPRESSOR
120V
CONDENSER FAN
S
C
R
COMPRESSOR
115V
S
R
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
17
Page 18
N8000 Series Drop-In Installation and Operation Manual
Delfield
Wiring Diagram N8630
CONDENSING UNIT
COOLING
THERMOSTAT
M
HEATER #1
HEATER #1 CONTACTOR
HEATER #1 LIMIT SWITCH
THERMOSTAT
120V-1PH-3KW HEATER
3-WAY SWITCH
L1
N
Wiring Diagram N8643 & N8656
CONDENSING UNIT
M
HEATER #1
COOLING
THERMOSTAT
HEATER #1 CONTACTOR
HEATER #1 LIMIT SWITCH
THERMOSTAT
3-WAY SWITCH
L1
L2
18
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
N
240V-1PH-5KW HEATER
®
Page 19
Delfield
Wiring Diagram N8669 & N8681
LI G
N8000 Series Drop-In Installation and Operation Manual
CONDENSING UNIT
HEATER #1
M
COOLING
THERMOSTAT
HEATER #1 CONTACTOR
3-WAY SWITCH
L1
L2
THERMOSTAT
HEATER #1 LIMIT SWITCH
HEATER #2 LIMIT SWITCH
N
(2) 240V-1PH-5KW HEATERS
HEATER #2 CONTACTOR
HEATER #2
Wiring Diagram N8800 208/230V
THERMOSTAT
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
L2
DOUBLE POLE THERMOSTAT ON MODELS N8873 & N8887 ONLY
19
Page 20
N8000 Series Drop-In Installation and Operation Manual
Delfield
Wiring Diagram N8700-D, N8700N & N8700-R
PILOT LIGHT (FURNISHED)
LINE
WIRES
#
OF
WARMERS
1
2
3 4
5
6
L1 G L2
H1
P
L1
L2
H2
INFINITE CONTROL
TO ADDITIONAL
FOOD WARMERS
AMPERES
120V,
PHASE
1
1 PHASE
208V,
WITH “OFF”
IN LINE
230V,
PHASE
1
POSITION
WIRES
8.3 4.8 5.3
16.7 9.6 10.6
25 14.4 15.9 14.4/15.9
33.3 19.2 21.3
24 26.6
28.8 31.3
19.2/21.3
24/26.1
28.8/31.3
1000 W - 120V
OR 1000/1222 W -
208-230 V
HEATING ELEMENT
208-230V, 3 PHASE
L1 L2 L3
14.4/15.9
19.2/21.3
19.2/21.3
28.8/31.3
14.4/15.9
14.4/15.9
19.2/21.3
28.8/31.3
L1 L2 G L3
20
30A SWITCH (OPTIONAL)
HA–1
HA–2
HA–3
HA–4
HA–5
HA–6
HA = HEATER ASSEMBLY
20A, 3–POLE SWITCH (OPTIONAL)
HA–1
HA–2
HA–4
HA–5
HA = HEATER ASSEMBLY
Standard Single Phase Optional Three Phase
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
ALL WIRING
MINIMUM 14 AWG
250C
HA–3
HA–6
®
Page 21
Delfield
Drop In Louver Panel
N8000 Series Drop-In Installation and Operation Manual
25”
Louver part #359-411-0003
Cutout dimension is 11” x 22” (27.9 cm x 55.9 cm).
Miscellaneous Parts 8000 SERIES
Deleld Part # Description 265-AXE-0000 Divider bar, 2.00” x 20.93” 243-ALS-0032 Divider bar, 13.00” x .90” 243-AB0-0001 Divider bar, 21.00” x .90” 3234242 Plastic drain 1701273 Trim gasket (sold by foot)
13”
Cap Tube Chart - R134A Refrigerant
Model Number Cap Tube Size/Length N8118B .036ID x 72” N8130B .036ID x 72” N8143B .036ID x 72” N8144-BR .036ID x 72” N8146NB .042ID x 120” N8156B .042ID x 120” N8159-BR .036ID x 72” N8168NB .042ID x 120” N8169B .042ID x 120” N8176-BR .042ID x 120” N8181B .054ID x 110” N8194-BR .042ID x 120”
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
21
Page 22
N8000 Series Drop-In Installation and Operation Manual
Delfield
Replacement Parts N8100-FA
8
7
6
9
1
2
5
4
3
10
11
12
13
14
15
16
17
N8131-FA N8144-FA N8157-FA N8169-FA N8182-FA Key Description 2-PAN 3-PAN 4-PAN 5-PAN 6-PAN
1 Upright diffuser 226-0V3-0030 226-0V3-0031 226-0V3-0032 226-0V3-0033 226-0V3-0034 2 Air deector 226-A9L-0030 226-A9L-0031 226-A9L-0032 226-A9L-0033 226-A9L-0034 3 Coil 3510086 3510086 3510086 3510086 3510086 4 Expansion valve 3516273 3516273 3516273 3516273 3516273 5 Coil assembly cover 019-0V0-0030 019-0V0-0038 019-0V0-0032 019-0V0-0033 019-0V0-0034 6 Fan assembly cover 226-0V1-0030 226-0V1-0031 226-0V1-0032 226-0V1-0033 226-0V1-0034 7 Adapter bar 243-AB0-0001 243-AB0-0001 243-AB0-0001 243-AB0-0001 243-AB0-0001 8 Perforated pan clip 270-0V5-0030 270-0V5-0031 270-0V5-0032 270-0V5-0033 270-0V5-0034 9 Black airow extrusion 316-991-0030 316-991-0031 316-991-0032 316-991-0033 316-991-0034 10 Cover support bracket 226-0V2-0030 226-0V2-0030 226-0V2-0030 226-0V2-0030 226-0V2-0030 11 Fan guard 3516173 3516173 3516173 3516173 3516173 12 Fan blade 3516172 3516172 3516172 3516172 3516172 13 Fan motor 2162691 2162691 2162691 2162691 2162691 14 Fan bracket 031-264-0000 031-264-0000 031-264-0000 031-264-0000 031-264-0000 15 Plexiglas end cap 091-0XL-0030 091-0XL-0030 091-0XL-0030 091-0XL-0030 091-0XL-0030 16 S/S thumb screw 9321541 9321541 9321541 9321541 9321541 17 Cond. Unit 000-BN5-0030 000-BN5-0035 000-BN5-0035 000-BN5-0036 000-BN5-0036 — Timer 2194345 2194345 2194345 2194345 2194345 Pressure Control 2193927 2193927 2193927 2193927 2193927 Rocker switch 2190154 2190154 2190154 2190154 2190154
22
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
®
Page 23
N8000 Series Drop-In Installation and Operation Manual
Delfield
Condensing Unit 1/4 H.P. R404a Low
8100-EF Series, 8100-EFN Series, N8131-FA, N8231, N8231G, N8245, N8245G, N8259, N8273, N8630, N8643, N8656, N8669
Key Deleld Part # Description
- 000-BN5-0030 Condensing Unit Assembly, 115V
- 000-BN5-003J Condensing Unit Assembly, 220V/50Hz 1 026-C58-0030 Shroud, Condenser Coil 2 3516457 Blade, Fan, 7.25” 3 2162717 Motor, fan, 9W, 115V 3 2162720 Motor, fan, 9W, 230V 4 2160020 Guard, Fan, 7.25” 5 3526999 Compressor, NF5.5CLX, 115V/60Hz, Danfoss 5 3527013 Compressor 220/50Hz, Danfoss 6 2194787 Capacitor, Start 280MFD 7 3516444 Compressor relay and overload, NF5.5CLX 8 3516322 Filter-dryer, (2) inlet .25” 9 075-231-0030 Pan, condensate 10 3516454 Condenser Coil
1
4
2
3
Miscellaneous Parts Not Included in Condensing Unit
- 2194099 15 Amp switch, 120V
- 2194400 15 Amp switch, 220V
- 2183348 Cord/plug assembly
- 3516225 Expansion valve
5
6
7
10
Condensing Unit Assembly 1/3 H.P. R404a, Low, N8259G, N8287, N8681
Key Deleld Part # Description
- 000-BN5-003G Condensing Unit Assembly, 115V
- 000-BN5-003M Condensing Unit Assembly, 220V/50Hz 1 026-C58-0030 Shroud, Condenser Coil 2 3516457 Blade, Fan, 7.25” 3 2162717 Motor, fan, 9W, 115V 3 2162720 Motor, fan, 9W, 230V 4 2160020 Guard, Fan, 7.25” 5 3527000 Compressor, NF7.0. 115V/60Hz, Danfoss 5 3527012 Compressor, 220V/50Hz Danfoss 6 3516324 High pressure switch 7 2194788 Capacitor, Start 320MFD 8 3516438 Compressor relay and overload, NF7CLX 9 3516322 Filter-dryer, (2) inlet .25” 10 3516458 Receiver tank
1
11 075-231-0030 Pan, condensate 12 3516454 Condenser Coil
4
3
2
5
8
9
6
7
8
Miscellaneous Parts Not Included in Condensing Unit
- 3516225 Expansion valve
- 2194099 15 Amp switch, 120V
- 2194400 15 Amp switch, 220V
- 2183348 Cord/plug assembly
®
11
12
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
9
10
23
Page 24
N8000 Series Drop-In Installation and Operation Manual
Delfield
Condensing Unit Assembly 1/2 H.P. R404a, Low, N8273G
Key Deleld Part # Description
- 000-BN5-0033 Condensing Unit Assembly, 115V
- 000-BN5-003N Condensing Unit Assembly, 220V/50Hz 1 026-C58-0031 Shroud, 1/2 HP Condenser Coil 2 3516554 Blade, Fan, 9.00”, 5-pedal 3 2160019 Guard, Fan, Condenser, Upright 4 2162716 Motor, Fan, 16W, 115V 4 2162721 Motor, Fan 16W, 230V 5 3516324 High Pressure Switch 6 3527001 Compressor, SC12CLX.2,115V/60Hz, Danfoss 6 3527011 Compressor, 220V/50Hz, Danfoss 7 3516322 Filter-dryer, (2) inlet .25” 8 2194789 Capacitor, Start 240MFD 9 3516441 Compressor relay, SC12CLX.2 10 3516459 Receiver 11 3516455 Condenser Coil
Miscellaneous Parts Not Included in Condensing Unit
- 3516225 Expansion valve
- 2194099 15 Amp switch, 120V
- 2194400 15 Amp switch, 220V
- 2183348 Cord/plug assembly
2
1
6
5
4
3
7
8
9
10
11
24
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
®
Page 25
N8000 Series Drop-In Installation and Operation Manual
Delfield
9
7 6
5
8
2
3
4
1
Narrow Base Condensing Unit Assembly 1/5 H.P. R134A, Low
N8118B, N8130B, N8143B, N8144-BR, N8146NB, N8159-BR, N8168NB
Key Deleld Part # Description 1 2183300 Harness, wire, power cord, 8100 2 3526694 Compressor, 1/5 h.p.,115v/60hz 2 3526718 Compressor, 1/5 h.p., 220v/50hz 3 3516047 Cold Control 4 024-ADB-0040 Compressor stand 5 031-264-0000 Bracket, fan motor, blower coil 6 3516172 Blade, fan, 5.56, CCW, Lexan, clear 7 2162691 Motor, fan, 115v, 50/60, UPPCO/bay 7 2162692 Motor, fan, 230V, 50/60, UPPCO/bay 8 026-ANM-0030 Fan baffle 9 3516067 Coil, condenser, 9 x 10, R-134a, 8100
- 3516191 Filter dryer
- 2194400 15 Amp switch, 220V
Narrow Base Condensing Unit Assembly N8156B, N8169B, N8176-BR, N8181B, N8194-BR
Key Deleld Part # Description 1 2183300 Harness, wire, power cord 2 3526703 Compressor, 1/3HP, 115/60, R134A, N8181B 2 3526695 Compressor, 1/4 h.p.,115v/60hz, N8156B, N8169B, N8176-BR, N8194-BR 2 3526719 Compressor, 1/4 h.p., 220v/50hz 3 3516047 Cold control 4 024-ADB-0041 Stand, compressor 5 2194013 Fan assembly, condenser, 8” blade, 115V 5 2162689 Fan assembly, condenser, 8” blade, 220V 6 026-ANM-0033 Baffle, fan 7 3516067 Coil, condenser, 9x10, R134A
- 3516191 Filter dryer
- 2194400 15 Amp switch, 220V
1
4
5
6
2
3
7
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
25
Page 26
N8000 Series Drop-In Installation and Operation Manual
Delfield
Condensing Unit Assembly 1/2 H.P. N8144-FA, N8157-FA
Key Deleld Part # Description
- 000-BN5-0035 Condensing Unit Assembly 1 026-C58-0031 Shroud, 1/2 HP condenser coil 2 3516554 Blade, fan 9.00”, 5 pedal 3 2160019 Guard, fan, condenser, upright 4 2162716 Motor, fan, 16W, 115V 5 3516462 Capacitor, start, assembly 6 3527026 Compressor, SC12MLX, 115V/60Hz, Danfoss 7 3516331 High pressure switch 8 3516322 Filter dryer, (2) inlet, .25” 9 3516459 Receiver 10 075-231-0031 Pan, condensate 11 3516455 Coil, 1/2 HP condensing
2
1
4
3
6
5
7
8
8
11
Condensing Unit Assembly 3/4 H.P. N8169-FA, N8182-FA
Key Deleld Part # Description
- 000-BN5-0036 Condensing Unit Assembly 1 026-C58-0032 Shroud, 3/4 HP condenser coil 2 2160019 Guard, fan, condenser, upright 3 3516442 Capacitor, start, run, assembly 4 3527021 Compressor, SC18MLX, 115V/60Hz, Danfoss 5 3516322 Filter dryer, (2) inlet, .25” 6 3516360 Tank, receiver 7 3516456 Coil, condenser, 3/4 HP
- 075-231-0031 Pan, condensate
- 3516433 Blade, fan 25º, 10”, CW, upright
- 2162716 Motor, fan, 16W, 115V
3
2
1
10
4
5
6
26
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
7
®
Page 27
N8000 Series Drop-In Installation and Operation Manual
Delfield
Food Well Assembly With Thermostat control N8600
10
For models N8600
1
2
9
8
7
6
5
4
3
Key Deleld Part # Description 1 2194940 Immersion heater 120V, 1Ph 3KW 1 2194942 Immersion heater 240V 1Ph 5KW 2 026-AO6-0041 Box, control, galv, 8600 series 3 372-ANQ-003D Front, collar, mounting, 8600 4 2193979 Switch, 3 position, 30Amp 5 372-ANS-0001 Cover, control box, 8700 series 6 2194190 Light, pilot, 125V, red 7 2194202 Thermostat, electric (heated) 8 3234556 Knob, thermostat control (heated) 9 2194185 Contactor, relay 30 Amp 120V 10 3516047 Temperature control (cold)
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
27
Page 28
N8000 Series Drop-In Installation and Operation Manual
Delfield
Food Well Assembly With Innite Control N8700
For models N8700D, N8700N, N8700ND, N8700R
Key Deleld Part # Description 1 3434703 Insulation, berglass, 9” x 48” 2 2194335 Thermostat, non-adjustable, 480˚F 3 026-103-0002 Bottom cover 4 3434663 Insulation, blanket, 24” wide 5 026-061-0001 Plate, deector, DFW, with or without drain 6 2194007 Element, heating, 208/230v, 1000/1222w 6 2194006 Element, heating, 120v 7 000-BQ9-Z0000 Well, hot food, with drain 7 000-BQ9-Z0001 Well, hot food, without drain
- 3234557 Knob, innite control
- 2194110 Control, innite, 240v, 14a
- 2194107 Control, innite, 120v
1
2
4
3
5
1
Food Well Assembly With Thermostat Control N8800
For models N8831, N8859, N8873, N8887
Key Deleld Part # Description 1 3234556 Knob, thermostat control 2 2193984 Thermostat 30A, N8873. N8887 2 2194012 Thermostat, 25A, N8831, N8845, N8859 3 2194007 Element, heating, 208/230v, 1000/1222w 3 2194006 Element, heating, 120v, 1000w 4 026-061-0001 Plate, deector, DFW, with drain
- 3434704 Insulation, berglass, 1” thick
- 3434664 Insulation, berfrax, 1” thick
6
7
4
28
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
1
2
3
®
Page 29
N8000 Series Drop-In Installation and Operation Manual
Delfield
Standard Labor Guidelines To Repair Or Replace Parts On Deleld Equipment
Advice and recommendations given by Deleld Service Technicians do not constitute or guarantee any special coverage.
•Amaximumof1-hourisallowedtodiagnose a defective component.
•Amaximumof1-hourisallowedforretrieval of parts not in stock.
•Amaximumtravel distance of 100 miles round trip and 2-hours will be reimbursed.
•Overtime,installation/start-up,normalcontroladjustments,generalmaintenance,glassbreakage,freight
damage, and/or correcting and end-user installation error will not be reimbursed under warranty unless pre­approved with a Service Work Authorization from Deleld. You must submit the number with the service claim.
Labor Of 1-Hour Is Allowed To Replace:
•CompressorStartComponentsandOverloadProtector • CondensateElement
•CondenserFanMotorandBlade • Contactor/Relay
•Hi-limit/ThermalProtectorSwitch • InniteSwitch
•SolenoidCoil • Thermostat
Labor Of 2 Hours To Replace:
•HeatingElement • Locate/RepairLeak
•SolenoidValve
Labor Of 3 Hours To Replace:
•CapillaryTubing • Condenser
•ExpansionValve
Labor Of 4 Hours To Replace:
•Compressor
This includes recovery of refrigerant and leak check. $55.00 maximum reimbursement for refrigerant recovery (includes recovery machine, pump, torch, oil, ux, minor
ttings, solder, brazing rod, nitrogen, or similar fees.)
Refrigerants:
•R134AAmaximumof$5.00/lb.or31/oz.willbereimbursed.
•R404AAmaximumof$15.00/lb.or$1.00/oz.willbereimbursed.
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
29
Page 30
N8000 Series Drop-In Installation and Operation Manual
Delfield
Standard One Year Limited Warranty (One year parts, 90 days labor)
The Deleld Company (“Deleld”) warrants to the Original Purchaser of the Deleld product (herein called the “Unit”) that such Unit, and all parts thereof, will be free from defects in material and workmanship under normal use and service for a period of one (1) year from the date of shipment of the Unit to the Original Purchaser or, if the Original Purchaser returns
the warranty card completely lled out including the date of installation within thirty (30) days of receipt of the Unit, one (1) year from the date of installation. During this one year
warranty period, Deleld will repair or replace any defective part or portion there of returned to Deleld by the Original Purchaser which Deleld determines was defective due to faulty material or workmanship. The Original purchaser will pay all labor, crating, freight and related costs incurred in the removal of the Unit of defective component and shipment to Deleld, except that during a period of either ninety (90) days from the date of shipment of the Unit to the Original Purchaser or, if the Original Purchaser returns the warranty card completely lled out including the date of installation within thirty (30) days of receipt of the Unit, ninety (90) days from the date of installation Deleld will pay all related labor costs. Deleld will pay the return costs if the Unit or part thereof was defective.
The term “Original Purchaser” as used herein means that person, rm, association, or corporation for whom the Unit was originally installed.
This warranty does not apply to any Unit or part thereof that has been subjected to misuse, neglect, alteration, or accident, such as accidental damage to the exterior nish, operated contrary to the recommendations specied by Deleld; or repaired or altered by anyone other than Deleld in any way so as to, in Deleld’s sole judgement, affect its quality or efficiency. This warranty does not apply to any Unit that has been moved from the location where it was originally installed. This warranty also does not cover the refrigerator drier or the light bulbs used in the Unit. The warranty is subject to the user’s
normal maintenance and care responsibility as set forth in the Service and Installation Manual, such as cleaning the condenser coil, and is in lieu of all other obligations of Deleld. Deleld neither assumes, nor authorizes any other person to assume for Deleld, any other liability in connection with Deleld’s products.
Removal or defacement of the original Serial Number or Model Number from any Unit shall be deemed to release Deleld from all obligations hereunder or any other obligations, express or implied.
Parts furnished by suppliers to Deleld are guaranteed by Deleld only to the extent of the original manufacturer’s express warranty to Deleld. Failure of the Original Purchaser to receive such manufacturers warranty shall in no way create any warranty, expressed or implied, or any other obligation or liability on Deleld’s part in respect thereof.
If shipment of a replacement part is requested prior to the arrival in the Deleld factory of the part claimed to be defective, the Original Purchaser must accept delivery of the replacement part on a C.O.D. basis, with credit being issued after the part has been received and inspected at Deleld’s plant and determined by Deleld to be within this warranty.
Under no condition does this warranty give the Original Purchaser the right to replace the defective Unit with a complete Unit of the same manufacturer or of another make. Unless authorized by Deleld in writing, this warranty does not permit the replacement of any part, including the motor-compressor, to be made with the part of another make or manufacturer.
No claims can be made under this warranty for spoilage of any products for any reason, including system failure.
The installation contractor shall be responsible for building access, entrance and eld conditions to insure sufficient clearance to allow any hood(s), vent(s), or Unit(s) if necessary, to be brought into the building. Deleld will not be responsible for structural changes or damages incurred during installation of the Unit or any exhaust system.
Deleld shall not be liable in any manner for any default or delay in performance hereunder caused by or resulting from any contingency beyond Deleld’s control, including, but not limited to, war, governmental restrictions or restraints, strike, lockouts, injunctions, re, ood, acts of nature, short or reduced supply of raw materials, or discontinuance of the parts by the original part manufacturer.
Except as provided in any Additional Four Year Protection Plan, if applicable, and the Service Labor Contract, if applicable, the foregoing is exclusive and in lieu of all other warranties, whether written or oral, express or implied. This warranty supersedes and excludes any prior oral or written representations or warranties. Deleld expressly disclaims any implied warranties of merchantability, tness for a particular purpose or compliance with any law, treaty, rule or regulation relating to the discharge of substances into the environment. The sole and exclusive remedies of any person relating to the Unit, and the full liability of Deleld for any breach of this warranty, will be as provided in this warranty.
Other than this Deleld Standard One Year Limited Warranty, any applicable Deleld Additional Four Year Protection Plan or applicable Deleld Service Labor Contract, the Original Purchaser agrees and acknowledges that no other warranties are offered or provided in connection with or for the Unit or any other part thereof.
In no event will Deleld be liable for special, incidental or consequential damages, or for damages in the nature of penalties.
30
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
®
Page 31
N8000 Series Drop-In Installation and Operation Manual
Delfield
Additional Four Year Protection Plan (for Motor-Compressor only)
Installation Deleld Model# Serial # Date
In addition to the Standard One Year Warranty on the Motor­Compressor contained in the above listed Deleld product (the “Unit”), The Deleld Company (“Deleld”) also agrees to repair, or exchange with similar or interchangeable parts in design and capacity at Deleld’s option, the defective Motor­Compressor contained in the Unit (the “Motor-Compressor), or any part thereof, for the Original Purchaser only, at any time during the four (4) years following the initial one (1) year period commencing on the date of installation for the Original Purchaser. Failure of the Original Purchaser to register
the registration card containing the Original Purchasers name, address, date of installation, model number and serial number of the Unit containing the Motor-Compressor within 30 days from the date of installation shall void this warranty. This additional warranty is only available if the Motor-
Compressor is inoperative due to defects in material or factory workmanship, as determined by Deleld in its sole judgement and discretion. The Original Purchaser shall be responsible for returning the defective Motor-Compressor to Deleld prepaid, F.O.B. at the address shown on the back cover of this manual.
The term “Original Purchaser” as used herein means that person, rm, association, or corporation for whom the Unit was originally installed.
The term “Motor-Compressor” as used herein does not include unit base, air or water cooled condenser, receiver, electrical accessories such as relay, capacitors, refrigerant controls, or condenser fan/motor assembly. This warranty does not cover labor charges incidental to the replacement of parts. This warranty further does not include any equipment to which said condensing unit is connected, such as cooling coils, temperature controls or refrigerant metering devices. This warranty shall be void if the Motor-Compressor, in Deleld’s sole judgement, has been subjected to misuse, neglect, alteration or accident, operated contrary to the recommendations specied by the Unit manufacturer, repaired or altered by anyone other than Deleld in any way so as, in Deleld’s sole judgment, to affect its quality or efficiency or if the serial number has been altered, defaced or removed. This Warranty does not apply to a Motor-Compressor in any Unit that has been moved from the location where it was originally installed. The addition of methyl chloride to the condensing unit or refrigeration system shall void this warranty.
General Conditions
Deleld shall not be liable in any manner for any default or delay in performance hereunder caused by or resulting from any contingency beyond Deleld’s control, including, but not limited to, war, governmental restrictions or restraints, strike, lockouts, injunctions, re, ood, acts of nature, short or reduced supply of raw materials, or discontinuance of any part or the Motor­Compressor by the unit manufacturer.
Replacement of a defective Motor-Compressor is limited to one (1) Motor-Compressor by us during the four (4) year period. Deleld shall replace the Motor-Compressor at no charge.
This warranty does not give the Original Purchaser of the Motor­Compressor the right to purchase a complete replacement Motor-Compressor of the same make or of another make. It further does not permit the replacement to be made with a Motor-Compressor of another kind unless authorized by Deleld. In the event Deleld authorizes the Original Purchaser to purchase a replacement Motor-Compressor locally, only the wholesale cost of the Motor-Compressor is refundable.
Expressly excluded from this warranty are damages resulting from spoilage of goods.
Except as provided in any applicable Standard One Year Limited Warranty or applicable Service Labor Contract, the foregoing is exclusive and in lieu of all other warranties, whether written or oral, express or implied. This Warranty supersedes and excludes any prior oral or written representations or warranties. Deleld expressly disclaims any implied warranties of merchantability, tness for a particular purpose or compliance with any law, treaty, rule or regulation relating to the Motor-Compressor, and the full liability of Deleld for any breach of this warranty, will be as provided in this warranty.
Other than any applicable Deleld Standard One year Limited Warranty, this Deleld Additional Four Year Protection Plan and any applicable Deleld Service Labor Contract, the Original Purchaser agrees and acknowledges that no other warranties are offered or provided in connection with or for the Motor­Compressor or any part thereof.
In no event will Deleld be liable for special, incidental or consequential damages, or for damages in the nature of penalties.
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.deleld.com
31
Page 32
Delfield
®
Mt. Pleasant, MI
Covington, TN
Thank you for choosing Delfield!
Help is a phone call away. Help our team of professional, courteous
customer service reps by having your model number and serial number
available at the time of your call (800) 733-8829.
Model: ____________________ S/N: ___________________
Installation Date: ____________
For a list of Deleld’s authorized parts depots,
visit our website at www.deleld.com.
®
Delfield
980S.IsabellaRd.,Mt.Pleasant,MI48858,U.S.A.•(989)773-7981or(800)733-8829•Fax(989)773-3210•www.deleld.com
Deleld reserves the right to make changes in design or specications without prior notice. ©2012 The Deleld Company. All rights reserved. Printed in the U.S.A.
DM8000 01/12