International Drop Ins
N8100B, 8100-EF, N8200, N8200G, N8700-D,
N8700-DESP N8800
Original Instructions
Installation, Operation and Maintenance Manual
This manual is updated as new information and models are released. Visit our website for the latest manual.
Part Number: DM8000int 4/15
International N8000 Series Drop-In Installation and Operation Manual
Important Warning And Safety Information
WARNING Read This Manual Thoroughly Before Operating, Installing, Or Performing Maintenance On The Equipment.
WARNING Failure To Follow Instructions In This Manual Can Cause Property Damage, Injury Or Death.
WARNING Do Not Store Or Use Gasoline Or Other Flammable Vapors Or Liquids In The Vicinity Of This Or Any Other
Appliance.
WARNING Unless All Cover And Access Panels Are In Place And Properly Secured, Do Not Operate This Equipment.
WARNING This Appliance Is Not Intended For Use By Persons Who Lack Experience Or Knowledge, Unless They Have
Been Given Supervision Or Instruction Concerning Use Of The Appliance By A Person Responsible For Their
Safety.
WARNING This Appliance Is Not To Be Played With.
WARNING Do Not Clean With Water Jet.
WARNING Do Not Use Electrical Appliances Inside The Food Storage Compartment Of This Appliance.
CAUTION Observe the following:
• Minimum clearances must be maintained from all walls and combustible materials.
• Keep the equipment area free and clear of combustible material.
• Allow adequate clearance for air openings.
• Operate equipment only on the type of electricity indicated on the specification plate.
• Unplug the unit before making any repairs.
• Retain this manual for future reference.
2
International N8000 Series Drop-In Installation and Operation Manual
Contents
Receiving And Inspecting Unit ................................................ 3
Serial Number Location .......................................................... 4
Warranty Information .............................................................. 4
Regulatory Certications ........................................................ 4
Specications ...................................................................... 5-7
Installation ........................................................................... 8-9
Operation ......................................................................... 10-12
Maintenance ......................................................................... 13
Wiring Diagram ................................................................ 14-16
N8700-DESP Technical Service Notes ................................ 16
Replacement Parts .......................................................... 17-19
Receiving And Inspecting The Equipment
Even though most equipment is shipped crated, care should be
taken during unloading so the equipment is not damaged while
being moved into the building.
1. Visually inspect the exterior of the package and skid or
container. Any damage should be noted and reported to
the delivering carrier immediately.
2. If damaged, open and inspect the contents with the carrier.
3. In the event that the exterior is not damaged, yet upon
opening, there is concealed damage to the equipment
notify the carrier. Notication should be made verbally as
well as in written form.
4. Request an inspection by the shipping company of the
damaged equipment. This should be done within 10 days
from receipt of the equipment.
5. Also open the compressor compartment housing and
visually inspect the refrigeration package. Be sure lines
are secure and base is still intact.
6. Freight carriers can supply the necessary damage forms
upon request.
7. Retain all crating material until an inspection has been
made or waived.
Uncrating The Equipment
First cut and remove the banding from around the crate.
Remove the front of the crate material, use of some tools will
be required.
3
International N8000 Series Drop-In Installation and Operation Manual
Serial Number Location
The serial number on self-contained refrigerated units is on the electrical
specications tag located near the condensing unit.
The serial number on remote refrigerated units is on the outside bottom
of the food well.
On hot food pans and hot/cold combination pans, the serial number tag
is located on the back of the control raceway or remote panel.
The serial number tag also lists the refrigerant used and the amount
of charge.
Always have the serial number of your unit available when calling for
parts or service.
This manual covers only standard 8000 series units. If you have a
custom designed unit, you should contact our parts/service department
at (800) 733-8829 for questions.
©2015 The Deleld Company. All rights reserved. Reproduction without written
permission is prohibited. “Deleld” is a registered trademark of The Deleld
Company.
Warranty Information
Visit http://www.deleld.com/minisite/service/warranty_info to:
• Register your product for warranty.
• Verify warranty information.
• View and download a copy of your warranty.
Regulatory Certications
Models are certified by:
National Sanitation Foundation (NSF)
Technical Inspection Association
European Conformity
4
International N8000 Series Drop-In Installation and Operation Manual
Export Specifications
Export N8100B Series Self-Contained Mechanically Cooled Pans - R404A
Model
N8118B-E
N8130B-E
N8143B-E
L D H
18”
(45.7cm)
30.75”
(78.1cm)
43.5”
(110.5cm)
26”
(66cm)
26”
(66cm)
26”
(66cm)
21.87”
(55.5cm)
21.87”
(55.5cm)
21.87”
(55.5cm)
Counter Cutout
Dimensions V/Hz/Ph Amps H.P. BTU
17” X 25”
(43.2cm x 63.5cm)
29.75” x 25”
(75.6cm x 63.5cm)
42.50” X 25”
(108.6cm x 63.5cm)
230-240/
50/1
230-240/
50/1
230-240/
50/1
1.5 1/5 204
1.5 1/5 379
1.5 1/5 569
Export N8100B Series Self-Contained Mechanically Cooled Pans - R134A
Model
N8156B-E
N8169B-E
L D H
56.25”
(142.9cm)
69”
(175.3cm)
26”
(66cm)
26”
(66cm)
21.87”
(55.5cm)
21.87”
(55.5cm)
Counter Cutout
Dimensions V/Hz/Ph Amps H.P. BTU
55.25” x 25”
(140.3cm x 63.5cm)
68” X 25”
(172.7cm x 63.5cm)
230-240/
50/1
230-240/
50/1
2.5 1/4 758
2.5 1/4 948
Export N8100NB Series Self-Contained Mechanically Cooled Pans Narrow Style - R404A
N8146NB-E
N8168NB-E
46.75”
(118.7cm)
67.5”
(171.5cm)
18”
(45.7cm)
18”
(45.7cm)
21.81”
(55.4cm)
21.81”
(55.4cm)
45.75” x 17”
(113.7cm x 43.2cm)
66.5” x 17”
(168.9cm x 43.2cm)
230240/50/1
230240/50/1
1.5 1/5 454 17/40º/-5º 680 175lbs
1.5 1/5 676 26/31º/4º 804 240lbs
Evap BTU/
TD/TEMP
19/38º/-3º
26/31º/4°
35/26º/9º
Evap BTU/
TD/TEMP
43/32º/3º
51/29º/6º
Sys
Ship
Cap
Weight
708 100lbs
(45kg)
812 140lbs
(64kg)
889 173lbs
(78kg)
Sys
Ship
Cap
Weight
1373 205lbs
(93kg)
1469 225lbs
(102kg)
(80kg)
(109kg)
Refrig.
12”x20”
Charge
Pans
454
g 1 N
454g2 N
454
g 3 N
Refrig.
12”x20”
Charge
Pans
454g 4 N
454g 5 N
454
g 2 N
454g 3 N
Temp
Class
Temp
Class
Export 8100-EF Series LiquiTec® Eutetic Fluid Refrigerated Cold Pans - R404A
Model L D H
8118-EF-E
8132-EF-E
8145-EF-E
8159-EF-E
8172-EF-E
8186-EF-E
18.20”
(46.2cm)
31.76”
(80.7cm)
45.32”
(115.1cm)
58.88”
(149.6cm)
72.44”
(184cm)
86”
(218.4cm)
26”
(66cm)
26”
(66cm)
26”
(66cm)
26”
(66cm)
26”
(66cm)
26”
(66cm)
23.25”
(59.1cm)
23.25”
(59.1cm)
23.25”
(59.1cm)
23.25”
(59.1cm)
23.25”
(59.1cm)
23.25”
(59.1cm)
Counter Cutout
Dimensions V/Hz/Ph Amps H.P.
17” x 25”
(43.2cm x 63.5cm)
30.75” x 25”
(78.1cm x 63.5cm)
44.25” x 25”
(112.4cm x 63.5cm)
57.87” x 25”
(147cm x 63.5cm)
71.5” x 25”
(181.6cm x 63.5cm)
85” x 25”
(215.9cm x 63.5cm)
230-240/
50/1
230-240/
50/1
230-240/
50/1
230-240/
50/1
230-240/
50/1
230-240/
50/1
2.5 1/4 204 19/50º/-
2.5 1/4 379 26/42º/-7° 1112 215lbs
2.5 1/4 569 35/36º/-1° 1259 265lbs
2.5 1/4 758 43/32º/3° 1373 285lbs
2.5 1/4 948 51/29º/6° 1469 295lbs
2.5 1/4 1138 59/26º/9° 1529 394lbs
BTU
Load
Evap BTU/
TD/TEMP
15°
Sys
Ship
Cap
Weight
928 169lbs
(77kg)
(98kg)
(120kg)
(130kg)
(134kg)
(179kg)
Refrig.
Charge
454g 1 N
454g 2 N
454g 3 N
454g 4 N
454g 5 N
454g 6 N
Export 8100-EFN Series LiquiTec® Slim Line Eutetic Fluid Refrigerated Cold Pans - R404A
8148-EFN-E
8169-EFN-E
8191-EFN-E
47.66”
(121.1cm)
69.22”
(175.8cm)
90.78”
(230.6cm)
18”
(45.7cm)
18”
(45.7cm)
18”
(45.7cm)
23.25”
(59.1cm)
23.25”
(59.1cm)
23.25”
(59.1cm)
46.88” x 17.25”
(119.1cm x 43.8cm)
68.5” x 17.25”
(174cm x 43.8cm)
90” x 17.25”
(228.6cm x 43.8cm)
230-240/
50/1
230-240/
50/1
230-240/
50/1
2.5 1/4 379 26/42º/-7° 1112 235lbs
(107kg)
2.5 1/4 569 35/36º/-1° 1259 285lbs
(130kg)
2.5 1/4 758 43/32º/13° 1373 295lbs
(134kg)
454g 2 N
454g 3 N
454g 4 N
12x20
Pans
Temp
Class
5
International N8000 Series Drop-In Installation and Operation Manual
Export Specifications
Export N8200 Series Self-Contained Frost Tops - R404A
Model
N8231-E
N8245-E
N8259-E 59.5”
N8273-E
N8287-E
L D H
31.75"
(80.6cm)
45.63”
(115.9cm)
(151.1cm)
73.38"
(186.4cm)
87.25"
(221.6cm)
26”
(66cm)
26”
(66cm)
26”
(66cm)
26”
(66cm)
26”
(66cm)
15.75”
(40cm)
15.75”
(40cm)
15.75”
(40cm)
15.75”
(40cm)
15.75”
(40cm)
Export N8200G Series Self-Contained Granite Cold Slabs - R404A
Model
N8231G-E
N8245G-E
N8259G-E
L D H
31.75”
(80.6cm)
45.63”
(115.9cm)
59.5”
(151.1cm)
25.87”
(65.7cm)
25.87”
(65.7cm)
25.87”
(65.7cm)
Counter Cutout
Dimensions V/Hz/Ph Amps H.P. BTU
19”
(48.3cm)
19”
(48.3cm)
19”
(48.3cm)
30.75” x 25"
(78.1cm x 63.5cm)
44.63” x 25”
(113.3cm x 63.5cm)
58.50” x 25”
(148.6cm x 63.5cm)
72.38” x 25”
(183.8cm x 63.5cm)
86.25" x 25"
(219.1cm x 63.5cm)
Counter Cutout
Dimensions V/Hz/Ph Amps H.P. BTU
30.75” X 25”
(78.1cm x 63.5cm)
44.63” x 25”
(113.4cm x 63.5cm)
58.5” x 25”
(148.6cm x 63.5cm)
230-240/
50/1
230-240/
50/1
230-240/
50/1
230-240/
50/1
230-240/
50/1
230-240/
50/1
230-240/
50/1
230-240/
50/1
1.5 1/5
1.5 1/5
2.5 1/4
2.5 1/4
2.8 1/3
379 26/42º/-7° 1112
569 35/36º/-1° 1259
758 43/32º/3° 1373
948 51/29º/6° 1469
1138 59/30º/5° 1787
1.5 1/5
1.5 1/5
2.8 1/3
Evap BTU/
TD/TEMP
Evap BTU/
TD/TEMP
379 26/42º/-7° 1112
569 35/36º/-1° 1259
758 43/37º/-2° 1572
Sys
Cap Ship Weight
Sys
Cap
142lbs
(64kg)
168lbs
(76kg)
193lbs
(88kg)
209lbs
(95kg)
239lbs
(108kg)
Ship
Weight
219lbs
(99kg)
284lbs
(129kg)
338lbs
(153kg)
Refrig.
Charge
454g N
454g N
454g N
454g N
454g N
Refrig.
Charge
454g
454g
454g
Temp
Class
Temp
Class
N
N
N
6