Delfield 4400 Installation Manual

Compact Refrigerators
4400 Series
Original Instructions Installation, Operation and Maintenance Manual
This manual is updated as new information and models are released. Visit our website for the latest manual.
*9294098*
Part Number: 9294098 01/18
Safety Notices
Warning
Read this manual thoroughly before operating, installing or performing maintenance on the equipment. Failure to follow instructions in this manual can cause property damage, injury or death.
DANGER
Do not install or operate equipment that has been misused, abused, neglected, damaged, or altered/modified from that of original manufactured specifications.
DANGER
Never stand on the unit! They are not designed to hold the weight of an adult, and may collapse or tip if misused in this manner.
DANGER
Keep power cord AWAY from HEATED surfaces. DO NOT immerse power cord or plug in water. DO NOT let power cord hang over edge of table or counter.
DANGER
All utility connections and fixtures must be maintained in accordance with local and national codes.
Warning
Authorized Service Representatives are obligated to follow industry standard safety procedures, including, but not limited to, local/national regulations for disconnection / lock out / tag out procedures for all utilities including electric, gas, water and steam.
Warning
Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. Never use flammable oil soaked cloths or combustible cleaning solutions, for cleaning.
Warning
This product contains chemicals known to the State of California to cause cancer and/or birth defects or other reproductive harm. Operation, installation, and servicing of this product could expose you to airborne particles of glasswool or ceramic fibers, crystalline silica, and/ or carbon monoxide. Inhalation of airborne particles of glasswool or ceramic fibers is known to the State of California to cause cancer. Inhalation of carbon monoxide is known to the State of California to cause birth defects or other reproductive harm.
Warning
Do not use electrical appliances or accessories other than those supplied by the manufacturer.
Warning
Use caution when handling metal surface edges of all equipment.
Warning
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision concerning use of the appliance by a person responsible for their safety. Do not allow children to play with this appliance.
Notice
Proper installation, care and maintenance are essential for maximum performance and trouble-free operation of your equipment. Visit our website www.mtwkitchencare. com for manual updates, translations, or contact information for service agents in your area.
Section 1 General Information
Section 2 Installation
Section 3 Operation
Table of Contents
Serial Number Information ................................................................................................ 4
Warranty Information........................................................................................................ 4
Regulatory Certifications ................................................................................................... 4
Model Numbers ................................................................................................................ 4
Location ............................................................................................................................ 6
Weight of Equipment ......................................................................................................... 7
Clearance Requirements .................................................................................................... 8
Dimensions ....................................................................................................................... 8
Capacity ............................................................................................................................ 9
Electrical Service ............................................................................................................. 11
Ground Fault Circuit Interrupter ................................................................................... 11
Rated Amperages, Horsepower, Voltage & Power Cord Chart ......................................11
Drain Connections ........................................................................................................... 12
Refrigeration ................................................................................................................... 13
Level & Stable ................................................................................................................. 14
Leg & Caster Installation .................................................................................................. 14
Changing Pan Height ....................................................................................................... 15
Shelf Installation Instructions .......................................................................................... 15
Optional Overshelf Installation Instructions ..................................................................... 15
Standard Cutting Board Bracket Mounting ....................................................................... 16
Standard Bracket Adjustment .......................................................................................... 16
Heavy Duty Cutting Board Bracket Mounting ................................................................... 17
Power To Cool ................................................................................................................. 20
Temperature Control ....................................................................................................... 20
Efficient Operation .......................................................................................................... 20
Defrost ............................................................................................................................ 20
Evaporator Fan Operation ................................................................................................ 20
Section 4 Maintenance
Interior Cleaning .............................................................................................................. 21
Gaskets .......................................................................................................................... 21
Fluorescent Light Bulb Replacement .............................................................................22
Preventing Blower Coil Corrosion .................................................................................22
Exterior Cleaning ............................................................................................................. 22
Drain .............................................................................................................................. 22
Drawer Assembly Cleaning .............................................................................................. 22
Cleaning the Condenser Coil ............................................................................................ 23
Doors/Hinges .................................................................................................................. 23
Part Number: 9294098 01/18 3
Section 1
General Information
Serial Number Information
The serial number is on the identification plate that also includes the model number. The identification plate is located near the top front corner of the left interior wall.
Always have the serial number of your unit available when calling for parts or service.
Warranty Information
Visit www.delfield.com/warranty to:
• Register your product for warranty.
• Verify warranty information.
• View and download a copy of your warranty.
Regulatory Certifications
All models are certified by:
National Sanitation Foundation (NSF)
Underwriters Laboratories (UL)
Underwriters Laboratories of Canada (cUL)
Model Numbers
This manual covers the following models:
Model Description
Refrigerated Front Breathers With Doors
4427N-6 4427N-8 4427N-9M
4432N-12M 4448N-8 4448N-12 4448N-18M Two Door Mega Top 4460N-8 4460N-12 4460N-12M
4460N-24M 4464N-8 4464N-12 4464N-12M Two Door Mega Top 4464N-16 Two Door Salad Top 4464N-18M 4464N-24M 4472N-12 4472N-18 4472N-18M
4472N-30M
Refrigerated Front Breathers With Drawers
D4427N-6 D4427N-8 D4427N-9M
D4432N-12M D4448N-8 D4448N-12 D4448N-18M Four Drawer Mega Top D4460N-8 D4460N-12 D4460N-12M
D4460N-24M D4464N-8 D4464N-12 D4464N-12M Four Drawer Mega Top D4464N-16 Four Drawer Salad Top D4464N-18M D4464N-24M D4472N-12 D4472N-18 D4472N-18M
D4472N-30M
One Door Salad Top
One Door Mega Top4427N-12M
Two Door Salad Top
Two Door Salad Top
Two Door Mega Top4460N-18M
Two Door Salad Top
Two Door Mega Top
Three Door Salad Top
Three Door Mega Top4472N-24M
Two Drawer Salad Top
Two Drawer Mega TopD4427N-12M
Four Drawer Salad Top
Four Drawer Salad Top
Four Drawer Mega TopD4460N-18M
Four Drawer Salad Top
Four Drawer Mega Top
Six Drawer Salad Top
Six Drawer Mega TopD4472N-24M
4 Part Number: 9294098 01/18
Section 1 General Information
Model Description
Refrigerated Front Breathers With Doors & 4” S/S Backsplash
ST4427N-8 One Door Salad Top ST4427N-12M One Door Mega Top ST4448N-8 ST4460N-8 ST4460N-12M ST4460N-18M ST4464N-8 ST4464N-12 ST4464N-12M ST4464N-18M ST4472N-12 Three Door Salad Top ST4472N-18M ST4472N-24M
Refrigerated Front Breathers w/ Drawers & 4” S/S Backsplash
STD4427N-8 Two Drawer Salad Top STD4427N-12M Two Drawer Mega Top STD4448N-8 STD4460N-8 STD4460N-12M STD4460N-18M STD4464N-8 STD4464N-12 STD4464N-12M STD4464N-18M STD4472N-12 Six Drawer Salad Top STD4472N-18M STD4472N-24M
Reduced Work Height Refrigerated Front Breathers With Doors
UC4427N-6 One Door Salad Top UC4427N-9M
UC4432N-12M UC4448N-8 UC4448N-12 UC4448N-18M Two Door Mega Top UC4460N-8 UC4460N-12 UC4460N-12M
UC4460N-24M UC4464N-8 UC4464N-12 UC4464N-12M Two Door Mega Top UC4464N-16 Two Door Salad Top UC4464N-18M UC4464N-24M UC4472N-12 UC4472N-18 UC4472N-18M
UC4472N-30M
Two Door Salad Top
Two Door Mega Top
Two Door Salad Top
Two Door Mega Top
Three Door Mega Top
Four Drawer Salad Top
Four Drawer Mega Top
Four Drawer Salad Top
Four Drawer Mega Top
Six Drawer Mega Top
One Door Mega TopUC4427N-12M
Two Door Salad Top
Two Door Salad Top
Two Door Mega TopUC4460N-18M
Two Door Salad Top
Two Door Mega Top
Three Door Salad Top
Three Door Mega TopUC4472N-24M
Model Description
Reduced Work Height Refrigerated Front Breathers With Drawers
UCD4427N-6 Two Drawer Salad Top UCD4427N-9M
Two Drawer Mega TopUCD4427N-12M UCD4432N-12M UCD4448N-8 UCD4448N-12 UCD4448N-18M Four Drawer Mega Top UCD4460N-8 UCD4460N-12 UCD4460N-12M
UCD4460N-24M UCD4464N-8 UCD4464N-12 UCD4464N-12M Four Drawer Mega Top UCD4464N-16 Four Drawer Salad Top UCD4464N-18M UCD4464N-24M UCD4472N-12 UCD4472N-18 UCD4472N-18M
UCD4472N-30M
Four Drawer Salad Top
Four Drawer Salad Top
Four Drawer Mega TopUCD4460N-18M
Four Drawer Salad Top
Four Drawer Mega Top
Six Drawer Salad Top
Six Drawer Mega TopUCD4472N-24M
Part Number: 9294098 01/18 5
Section 2
Installation
DANGER
Installation must comply with all applicable fire and health codes in your jurisdiction.
DANGER
Use appropriate safety equipment during installation and servicing.
Warning
Do not damage the refrigeration circuit when installing, maintaining or servicing the unit.
Location
Warning
This equipment must be positioned so that the plug is accessible unless other means for disconnection from the power supply (e.g., circuit breaker or disconnect switch) is provided.
Warning
Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to the electrical conduit or gas lines.
The location selected for the equipment must meet the following criteria. If any of these criteria are not met, select another location.
• Units are intended for indoor use only.
• The location MUST be level, stable and capable of supporting the weight of the equipment.
• The location MUST be free from and clear of combustible materials.
• Equipment MUST be level both front to back and side to side.
• Position the equipment so it will not tip or slide.
• Front casters MUST be locked once positioned.
• Recommended air temperature is 50° - 100°F (10° - 38°C).
• Proper air supply for ventilation is REQUIRED AND CRITICAL for safe and efficient operation.
• Do not obstruct the flow of ventilation air. Make sure the air vents of the equipment are not blocked.
• Do not install the equipment directly over a drain. Steam rising up out of the drain will adversely affect operation, air circulation, and damage electrical / electronic components.
Warning
To avoid instability the installation area must be capable of supporting the combined weight of the equipment and product. Additionally the equipment must be level side to side and front to back.
Warning
This equipment is intended for indoor use only. Do not install or operate this equipment in outdoor areas.
6 Part Number: 9294098 01/18
Section 2 Installation
Weight of Equipment
Model Ship Weight
Refrigerated Front Breathers With Doors
4427N-6 223lbs (101kg) 4427N-8 240lbs (109kg) 4427N-9M 4427N-12M 4432N-12M 245lbs (111kg) 4448N-8
4448N-18M 4460N-8 4460N-12 4460N-12M 4460N-18M 4460N-24M 4464N-8 4464N-12 4464N-12M 4464N-16 4464N-18M 4464N-24M 4472N-12 4472N-18 4472N-18M 4472N-24M 4472N-30M
Refrigerated Front Breathers With Drawers
D4427N-6 245lbs (111kg) D4427N-8 240lbs (109kg) D4427N-9M 245lbs (111kg) D4427N-12M 245lbs (111kg) D4432N-12M 293lbs (133kg) D4448N-8
D4448N-18M D4460N-8 D4460N-12 D4460N-12M D4460N-18M D4460N-24M D4464N-8 D4464N-12 D4464N-12M D4464N-16 D4464N-18M D4464N-24M D4472N-12 D4472N-18 D4472N-18M D4472N-24M D4472N-30M
223lbs (101kg)
316lbs (143kg)4448N-12
411lbs (186kg)
421lbs (191kg)
461lbs (209kg)
398lbs (181kg)D4448N-12
495lbs (225kg)
522lbs (237kg)
545lbs (247kg)
Model Ship Weight
Refrigerated Front Breathers With Doors & 4” S/S Backsplash
ST4427N-8 240lbs (109kg) ST4427N-12M 223lbs (101kg) ST4448N-8 316lbs (143kg) ST4460N-8
411lbs (186kg)ST4460N-12M ST4460N-18M ST4464N-8 ST4464N-12 ST4464N-12M ST4464N-18M ST4472N-12
ST4472N-24M
Refrigerated Front Breathers With Drawers & 4” S/S Backsplash
STD4427N-8 240lbs (109kg) STD4427N-12M 245lbs (111kg) STD4448N-8 398lbs (181kg) STD4460N-8
STD4460N-18M STD4464N-8 STD4464N-12 STD4464N-12M STD4464N-18M STD4472N-12
STD4472N-24M
Reduced Work Height Refrigerated Front Breathers With Doors
UC4427N-6
UC4427N-12M UC4432N-12M 245lbs (111kg) UC4448N-8
UC4448N-18M UC4460N-8 UC4460N-12 UC4460N-12M UC4460N-18M UC4460N-24M UC4464N-8 UC4464N-12 UC4464N-12M UC4464N-16 UC4464N-18M UC4464N-24M UC4472N-12 UC4472N-18 UC4472N-18M UC4472N-24M UC4472N-30M
421lbs (191kg)
461lbs (209kg)ST4472N-18M
495lbs (225kg)STD4460N-12M
522lbs (237kg)
545lbs (247kg)STD4472N-18M
223lbs (101kg)UC4427N-9M
316lbs (143kg)UC4448N-12
411lbs (186kg)
421lbs (191kg)
461lbs (209kg)
Part Number: 9294098 01/18 7
Installation Section 2
Model Ship Weight
Reduced Work Height Refrigerated Front Breathers With Drawers
UCD4427N-6
245lbs (111kg)UCD4427N-9M UCD4427N-12M UCD4432N-12M 293lbs (133kg) UCD4448N-8
398lbs (181kg)UCD4448N-12 UCD4448N-18M UCD4460N-8 UCD4460N-12 UCD4460N-12M UCD4460N-18M UCD4460N-24M UCD4464N-8 UCD4464N-12 UCD4464N-12M UCD4464N-16 UCD4464N-18M UCD4464N-24M UCD4472N-12 UCD4472N-18 UCD4472N-18M UCD4472N-24M UCD4472N-30M
495lbs (225kg)
522lbs (237kg)
545lbs (247kg)
Clearance Requirements
• Keep the vents clean and free of obstruction.
• Casters or optional legs must be used and not removed.
• Provide good air circulation inside and outside the cabinet.
• Do not pack refrigerator so full that air cannot circulate.
• Avoid hot corners and locations near stoves and ovens.
• These cabinets have Delfield’s “front-breathing” design. They may be installed flush against a wall or built into a counter as required.
• The louver at the floor level must be kept completely clear of any obstructions. Proper operation is dependent on air being able to flow freely through the front louver. The louver at the back of the cabinet is not necessary for proper operation, but any air flow through it is beneficial.
Caution
Any restriction of the proper air flow outlined above, total or partial, will void the warranty on the cabinet.
Dimensions
Model Length Depth Work Height
Refrigerated Front Breathers With Doors
4427N-6 4427N-8 4427N-9M 4427N-12M 4432N-12M 32” (81cm) 31.50” (80cm) 36.00” (91cm) 4448N-8
4448N-18M 4460N-8 4460N-12 4460N-12M 4460N-18M 4460N-24M 4464N-8 4464N-12 4464N-12M 4464N-16 4464N-18M 4464N-24M 4472N-12 4472N-18 4472N-18M 4472N-24M 4472N-30M
Refrigerated Front Breathers With Drawers
D4427N-6 D4427N-8 D4427N-9M D4427N-12M D4432N-12M 32” (81cm) 31.50” (80cm) 36.00” (91cm) D4448N-8
D4448N-18M D4460N-8 D4460N-12 D4460N-12M D4460N-18M D4460N-24M D4464N-8 D4464N-12 D4464N-12M D4464N-16 D4464N-18M D4464N-24M D4472N-12 D4472N-18 D4472N-18M D4472N-24M D4472N-30M
27” (69cm) 31.50” (80cm) 36.00” (91cm)
48” (122cm) 31.50” (80cm) 36.00” (91cm)4448N-12
60” (152cm) 31.50” (80cm) 36.00” (91cm)
64” (163cm) 31.50” (80cm) 36.00” (91cm)
72” (183cm) 31.50” (80cm) 36.00” (91cm)
27” (69cm) 31.50” (80cm) 36.00” (91cm)
48” (122cm) 31.50” (80cm) 36.00” (91cm)D4448N-12
60” (152cm) 31.50” (80cm) 36.00” (91cm)
64” (163cm) 31.50” (80cm) 36.00” (91cm)
72” (183cm) 31.50” (80cm) 36.00” (91cm)
8 Part Number: 9294098 01/18
Loading...
+ 16 hidden pages