Original Instructions
Installation, Operation and Maintenance Manual
This manual is updated as new information and models are released. Visit our website for the latest manual.
*9294098*
Part Number: 9294098 01/18
Safety Notices
Warning
n
Read this manual thoroughly before operating, installing
or performing maintenance on the equipment. Failure
to follow instructions in this manual can cause property
damage, injury or death.
DANGER
Do not install or operate equipment that has been misused,
abused, neglected, damaged, or altered/modified from
that of original manufactured specifications.
DANGER
Never stand on the unit! They are not designed to hold
the weight of an adult, and may collapse or tip if misused
in this manner.
DANGER
Keep power cord AWAY from HEATED surfaces. DO NOT
immerse power cord or plug in water. DO NOT let power
cord hang over edge of table or counter.
DANGER
All utility connections and fixtures must be maintained in
accordance with local and national codes.
Warning
n
Authorized Service Representatives are obligated to follow
industry standard safety procedures, including, but not
limited to, local/national regulations for disconnection
/ lock out / tag out procedures for all utilities including
electric, gas, water and steam.
Warning
n
Do not store or use gasoline or other flammable vapors
or liquids in the vicinity of this or any other appliance.
Never use flammable oil soaked cloths or combustible
cleaning solutions, for cleaning.
Warning
n
This product contains chemicals known to the State of
California to cause cancer and/or birth defects or other
reproductive harm. Operation, installation, and servicing
of this product could expose you to airborne particles
of glasswool or ceramic fibers, crystalline silica, and/
or carbon monoxide. Inhalation of airborne particles
of glasswool or ceramic fibers is known to the State of
California to cause cancer. Inhalation of carbon monoxide
is known to the State of California to cause birth defects
or other reproductive harm.
Warning
n
Do not use electrical appliances or accessories other than
those supplied by the manufacturer.
Warning
n
Use caution when handling metal surface edges of all
equipment.
Warning
n
This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge,
unless they have been given supervision concerning use
of the appliance by a person responsible for their safety.
Do not allow children to play with this appliance.
Notice
Proper installation, care and maintenance are essential
for maximum performance and trouble-free operation of
your equipment. Visit our website www.mtwkitchencare.
com for manual updates, translations, or contact
information for service agents in your area.
Section 1
General Information
Section 2
Installation
Section 3
Operation
Table of Contents
Serial Number Information ................................................................................................ 4
The serial number is on the identification plate that also
includes the model number. The identification plate is
located near the top front corner of the left interior wall.
Always have the serial number of your unit available
when calling for parts or service.
Warranty Information
Visit www.delfield.com/warranty to:
• Register your product for warranty.
• Verify warranty information.
• View and download a copy of your warranty.
Regulatory Certifications
All models are certified by:
•
•
•
National Sanitation Foundation (NSF)
Underwriters Laboratories (UL)
Underwriters Laboratories of Canada (cUL)
Model Numbers
This manual covers the following models:
ModelDescription
Refrigerated Front Breathers With Doors
4427N-6
4427N-8
4427N-9M
4432N-12M
4448N-8
4448N-12
4448N-18MTwo Door Mega Top
4460N-8
4460N-12
4460N-12M
4460N-24M
4464N-8
4464N-12
4464N-12MTwo Door Mega Top
4464N-16Two Door Salad Top
4464N-18M
4464N-24M
4472N-12
4472N-18
4472N-18M
4472N-30M
Refrigerated Front Breathers With Drawers
D4427N-6
D4427N-8
D4427N-9M
D4432N-12M
D4448N-8
D4448N-12
D4448N-18MFour Drawer Mega Top
D4460N-8
D4460N-12
D4460N-12M
D4460N-24M
D4464N-8
D4464N-12
D4464N-12MFour Drawer Mega Top
D4464N-16Four Drawer Salad Top
D4464N-18M
D4464N-24M
D4472N-12
D4472N-18
D4472N-18M
D4472N-30M
One Door Salad Top
One Door Mega Top4427N-12M
Two Door Salad Top
Two Door Salad Top
Two Door Mega Top4460N-18M
Two Door Salad Top
Two Door Mega Top
Three Door Salad Top
Three Door Mega Top4472N-24M
Two Drawer Salad Top
Two Drawer Mega TopD4427N-12M
Four Drawer Salad Top
Four Drawer Salad Top
Four Drawer Mega TopD4460N-18M
Four Drawer Salad Top
Four Drawer Mega Top
Six Drawer Salad Top
Six Drawer Mega TopD4472N-24M
4 Part Number: 9294098 01/18
Section 1 General Information
ModelDescription
Refrigerated Front Breathers With Doors & 4” S/S Backsplash
ST4427N-8One Door Salad Top
ST4427N-12MOne Door Mega Top
ST4448N-8
ST4460N-8
ST4460N-12M
ST4460N-18M
ST4464N-8
ST4464N-12
ST4464N-12M
ST4464N-18M
ST4472N-12Three Door Salad Top
ST4472N-18M
ST4472N-24M
Refrigerated Front Breathers w/ Drawers & 4” S/S Backsplash
STD4427N-8Two Drawer Salad Top
STD4427N-12MTwo Drawer Mega Top
STD4448N-8
STD4460N-8
STD4460N-12M
STD4460N-18M
STD4464N-8
STD4464N-12
STD4464N-12M
STD4464N-18M
STD4472N-12Six Drawer Salad Top
STD4472N-18M
STD4472N-24M
Reduced Work Height Refrigerated Front Breathers With Doors
UC4427N-6One Door Salad Top
UC4427N-9M
UC4432N-12M
UC4448N-8
UC4448N-12
UC4448N-18MTwo Door Mega Top
UC4460N-8
UC4460N-12
UC4460N-12M
UC4460N-24M
UC4464N-8
UC4464N-12
UC4464N-12MTwo Door Mega Top
UC4464N-16Two Door Salad Top
UC4464N-18M
UC4464N-24M
UC4472N-12
UC4472N-18
UC4472N-18M
UC4472N-30M
Two Door Salad Top
Two Door Mega Top
Two Door Salad Top
Two Door Mega Top
Three Door Mega Top
Four Drawer Salad Top
Four Drawer Mega Top
Four Drawer Salad Top
Four Drawer Mega Top
Six Drawer Mega Top
One Door Mega TopUC4427N-12M
Two Door Salad Top
Two Door Salad Top
Two Door Mega TopUC4460N-18M
Two Door Salad Top
Two Door Mega Top
Three Door Salad Top
Three Door Mega TopUC4472N-24M
ModelDescription
Reduced Work Height Refrigerated Front Breathers With Drawers
UCD4427N-6Two Drawer Salad Top
UCD4427N-9M
Two Drawer Mega TopUCD4427N-12M
UCD4432N-12M
UCD4448N-8
UCD4448N-12
UCD4448N-18MFour Drawer Mega Top
UCD4460N-8
UCD4460N-12
UCD4460N-12M
UCD4460N-24M
UCD4464N-8
UCD4464N-12
UCD4464N-12MFour Drawer Mega Top
UCD4464N-16Four Drawer Salad Top
UCD4464N-18M
UCD4464N-24M
UCD4472N-12
UCD4472N-18
UCD4472N-18M
UCD4472N-30M
Four Drawer Salad Top
Four Drawer Salad Top
Four Drawer Mega TopUCD4460N-18M
Four Drawer Salad Top
Four Drawer Mega Top
Six Drawer Salad Top
Six Drawer Mega TopUCD4472N-24M
Part Number: 9294098 01/18 5
Section 2
Installation
DANGER
Installation must comply with all applicable fire and
health codes in your jurisdiction.
DANGER
Use appropriate safety equipment during installation and
servicing.
Warning
n
Do not damage the refrigeration circuit when installing,
maintaining or servicing the unit.
Location
Warning
n
This equipment must be positioned so that the plug is
accessible unless other means for disconnection from the
power supply (e.g., circuit breaker or disconnect switch)
is provided.
Warning
n
Adequate means must be provided to limit the movement
of this appliance without depending on or transmitting
stress to the electrical conduit or gas lines.
The location selected for the equipment must meet the
following criteria. If any of these criteria are not met, select
another location.
• Units are intended for indoor use only.
• The location MUST be level, stable and capable of
supporting the weight of the equipment.
• The location MUST be free from and clear of combustible
materials.
• Equipment MUST be level both front to back and side to
side.
• Position the equipment so it will not tip or slide.
• Front casters MUST be locked once positioned.
• Recommended air temperature is 50° - 100°F
(10° - 38°C).
• Proper air supply for ventilation is REQUIRED AND
CRITICAL for safe and efficient operation.
• Do not obstruct the flow of ventilation air. Make sure the
air vents of the equipment are not blocked.
• Do not install the equipment directly over a drain. Steam
rising up out of the drain will adversely affect operation,
air circulation, and damage electrical / electronic
components.
Warning
n
To avoid instability the installation area must be capable
of supporting the combined weight of the equipment
and product. Additionally the equipment must be level
side to side and front to back.
Warning
n
This equipment is intended for indoor use only. Do not
install or operate this equipment in outdoor areas.
• Casters or optional legs must be used and not removed.
• Provide good air circulation inside and outside the
cabinet.
• Do not pack refrigerator so full that air cannot circulate.
• Avoid hot corners and locations near stoves and ovens.
• These cabinets have Delfield’s “front-breathing” design.
They may be installed flush against a wall or built into a
counter as required.
• The louver at the floor level must be kept completely
clear of any obstructions. Proper operation is dependent
on air being able to flow freely through the front louver.
The louver at the back of the cabinet is not necessary for
proper operation, but any air flow through it is beneficial.
Caution
,
Any restriction of the proper air flow outlined above,
total or partial, will void the warranty on the cabinet.