PLEASE SAVE THESE INSTRUCTIONS!
............................................
.....................................................................................
...................................................................................
.............................................................................
...................................................................................
...................................................................................
................................................................
The serial number on 18000 PTB & 18000 BUC Series units
The serial number on CTP-NB Series units is located on the front of
Always have the serial number of your unit available when calling for
©2003 The Delfield Company. All rights reserved. Reproduction
without written permission is prohibited.
CONTENTS
18699 PTB
MODEL
NUMBER
H.P.
# OF
DOORS
18000 PTB series pizza tables with raised rail
18648 PTB
18660 PTB
18672 PTB
18691 PTB
(1) 27"
19" & 27"
(2) 27"
(2) 27" & (1) 19"
(3) 27"
# OF
SHELVES
1
2
2
3
3
1/4
1/3
1/2
1/2
3/4
AMPS
10.0
12.0
14.0
14.0
16.0
SHELF
AREA
3.36 ft
2
5.63 ft
2
7.72 ft
2
9.99 ft
2
11.58 ft
2
NEMA
PLUG
5-15P
5-15P
5-20P
5-20P
5-20P
18000 BUC series work tables
STORAGE
CAPACITY
8.39 ft
3
14.31 ft
3
16.77 ft
3
22.82 ft
3
25.87 ft
3
STORAGE
CAPACITY
9.77 ft
3
14.31 ft
3
17.79 ft
3
23.05 ft
3
25.82 ft
3
BTU LOAD
BASE/RAIL
470/441
694/617
776/794
1062/1058
1144/1147
SHIP WEIGHT
LBS/KG
520/236
575/260
635/288
770/350
805/365
BTU SYSTEM
CAP. BASE/RAIL
MODEL
NUMBER
H.P.
NUMBER OF
DOORS
# OF
SHELVES
AMPS
SHELF NEMA
PLUGAREA
SHIP WEIGHT
LBS/KG
1903/971
2314/1121
3097/1544
3807/1839
5286/2191
186114 PTB
(4) 24" 4 3/4 16.013.22 ft
2
5-20P30.9 ft
3
1297/1323 927/4205286/2411
18699 BUC
18648 BUC
18660 BUC
18672 BUC
18691 BUC
(1) 27"
19" & 27"
(2) 27"
(2) 27" & (1) 19"
(3) 27"
1
2
2
3
3
BTU
LOAD
475
686
856
1169
1220
BTU
SYS. CAP.
1462
1462
2261
2261
2591
1/5
1/5
1/4
1/4
1/3
8.0
8.0
10.0
10.0
12.0
3.95 ft
2
6.51 ft
2
7.90 ft
2
Volts/Hertz/Phase for all CTP-NB, 18000 PTB & 18000 BUC Series units is 115/60/1
10.29 ft
2
11.85 ft
2
5-15P
5-15P
5-15P
5-15P
5-15P
390/177
435/197
495/225
535/243
594/269
27.58 ft
3
186114 BUC
(4) 24" 4 1373 2591 1/3 12.014.42 ft
2
5-15P 685/310
CTP-NB Counter top condiment rail
MODEL
NUMBER
H.P.
1/6 PAN SIZE
CAPACITY
# OF
ADAPTER BARS
AMPS
NEM
A
PLUG
SHIP WEIGHT
LBS/KG
CTP8146-NB
CTP8160-NB
CTP8175-NB
8
12
16
5
7
9
BTU
LOAD
305
462
609
BTU
SYS. CAP.
523
653
742
1/5
1/5
1/5
4.0
4.0
4.0
5-15P
5-15P
5-15P
121/54.9
158/71.7
197/89.4
SPECIFICATIONS
SERIAL NUMBER INFORMATION
the total weight of the cabinet and contents. A fully loaded 72” long
Avoid hot corners and locations near stoves and ovens.
A level cabinet looks better and will perform better because the
to employees. It is the owner’s and operator’s
to the proper power source. A protected circuit of the correct
voltage and amperage must be run for con nec tion of the line cord,
The power switch must be turned to OFF and the
RECEIVING AND INSPECTING THE EQUIPMENT
while being moved into the building.
to the delivering carrier immediately.
visually inspect the refrigeration package. Be sure lines
INSTALLATION
This unit is equipped with two on/off switches located behind the
position. Tem per a ture ranges for the base are 36° to
The switch labeled rail is for the raised rail.
Temperature ranges for the raised rail are 33°F to 41°F.
to turn the rail off at night to save energy and the rail
will have time to defrost as needed. It also helps to
A minimum of one hour of off time per day with the pans
the pans. Product left in the rail during a four hour off period will
when you return the pans to the raised rail.
The power must be turned to OFF and the unit
All R404A models have a high pressure limiting device. Under
failure or a plugged or blocked condenser, this device may shut
The unit is equipped with one on/off switch located on the right
this switch is turned to the
position. Tem per a ture ranges for
the rail are 33° to 41° F.
This allows you to turn the rail
at night to save energy and the
A minimum of one hour of off time per day with the pans removed
from the rail is required to properly defrost the rail. If pans are left
when you return the pans to the raised rail.
The power switch must be turned to OFF and the
will begin operating. Delfield refrigerated bases are designed to
OPERATION: 18000 PTB SERIES
OPERATION: 18000 BUC SERIES
OPERATION: CTP-NB SERIES
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
The factory recommended low-pressure control settings for 18000-PTB’s are:
55# cut-in and 30# cut-out to maintain
The factory recommended low-pressure control settings for 18000-BUC’s are:
REFRIGERANT CHARGES AND PRESSURE CONTROL SETTINGS
All Delfield refrigerated models come equipped with
volt, grounded electrical outlet.
The temperature is controlled by an adjustable pressure
near the knob, with an arrow
to indicate the adjustment direction. These controls are
field adjustable and do not require a service agent. If you
In attempting to adjust the pressure control,
you can do damage to your unit by accidentally
the pressure control adjusted.
PRESSURE CONTROL SETTINGS