Delfield 18300 Service Manual

The Delfield Company
V18000 SERIES
Refrigerator and Freezer Bases
18000 SERIES
Refrigerated Work
Tables
Effective April 1990
WARNING:
Read Before
Operating
The Delfield Company
STANDARD ONE YEAR WARRANTY — REFRIGERATED UNITS
We warrant to the original purchaser every new Delfield refrigerated unit, and all parts thereof, to be free from defects in material and workmanship under normal use and service for a period of one year from the shipping date of the units, to the original purchaser only, our obligation here under being limited to the repairing or replacing F.O.B. Delfield plant, without cost to such original purchaser within such period, any part or portion thereof, which upon examination we judge to be thus defective. This warranty shall not be deemed to place any liability on us for any labor cost, crating cost, or freight cost incurred in the removal of the unit and shipment to Delfield plant.
The warranty does not apply to any material that has been subjected to misuse, neglect, alteration, or accident, such as accidental damage to the exterior finish, and to any refrigerated unit or part thereof, which has been repaired or altered by other than Delfield in any way so as in our judgment to affect its quality or efficiency. This warranty also does not cover the refrigerator drier or the light bulbs used in the refrigerator. THE WARRANTY IS SUBJECT TO THE USER'S NORMAL RESPONSIBILITY; AND IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, WHETHER WRITTEN, OR ORAL OR IMPLIED, INCLUDING ANY WARRANTY OF PERFORMANCE, MERCHANTABILITY, OR FITNESS FOR PURPOSE, AND OF ALL OTHER OBLIGATIONS ON OUR PART. We neither assume, nor authorize any other person to assume for us, any other liability in connection with our products.
Removal or defacement of the original Serial Number or Model Number from any refrigerated unit shall be deemed to release us from all obligations hereunder or any other obligations, express or implied.
Failure of the purchaser to receive such manufacturer's warranty shall in no way create any warranty express or implied, or any other obligation or liability on our part in respect thereof.
If shipment of a replacement part is requested prior to the arrival in Delfield factory of the part claimed to be defective, the customer must accept delivery of the replacement part on a C.O.D. basis, with credit being issued when the defective part has been received and inspected at our plant and proved to be within this warranty.
This warranty under no condition gives the right to the purchaser-user to replace the defective unit with a complete unit of the same manufacturer or of another make. It further does not permit the replacement to be made with a motor compressor assembly of another kind unless authorized by us in writing.
No claims can be made against the warranty for spoilage of products on account of refrigeration failure.
Performance by use under this warranty is contingent upon causes beyond our control, and we shall not be liable for any default or delay in performance there under caused by any contingency beyond our control, including war, governmental restrictions or restrains, strikes, fire, floods. Acts of God, short or reduced supply or raw materials, or discontinuance of the parts by the original part manufacturer.
TABLE OF CONTENTS
INSTALLATION 3
OPERATION 3
SPECIFICATIONS 4
MAINTENANCE 5
WIRING SCHEMATICS 5 & 6
REPLACEMENT PARTS LIST 6
TROUBLESHOOTING REFERENCE CHART 7
INSTALLATION
LOCATION: All Models — Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and contents Reinforce the floor if necessary to provide for maximum loading Good refrigeration is based on good air circulation inside and out
Inside Cabinet: Do not pack refrigerator so full that
air cannot circulate
Outside Cabinet: Be sure that the unit has access to
ample air It is suggested that the rear of the unit be no less than two inches from any wall, partition or any other object which will restrict exhaust air flow Avoid hot corners and locations
near stoves and ovens LEVELING: A level cabinet looks better and will perform better because:
1 The drain pan will drain properly 2 The doors will line up with the door frames properly
3 The cabinet will not be subject to undue strain STABILIZING: Some models are supplied on casters for your convenience, for ease of cleaning underneath and mobility However it is of utmost importance the cabinet be installed in a stable condition with the front wheels locked
ELECTRICAL: Refer to the amperage data on page 4 and your local code or the National Electrical Code for proper wire sizes All case wiring is labeled with the required voltage — be sure it is connected to the proper power source A protected circuit of the correct voltage and amperage must be run for connection of the line cord NOTE: This unit is intended to operate on a maximum 15 amp fuse at 115 volts, 60 hertz, single phase On cord-connected units only, a double-pole, single throw ON/OFF switch is located directly behind the louvered panel covering the compressor section Its purpose is to disconnect all electrical current to the unit For your protection this switch should be turned to its OFF position whenever doing the following:
1 Performing maintenance functions 2 Changing or replacing light bulbs 3 Replacing a wom-out fan motor assembly
4 Cleaning the refrigerated cabinet area Under no circumstances should the unit be operated without the louvered panel in place! If receptacles are to be mounted in the unit backsplash, they must be wired independently from the existing unit wiring If a unit does not have a condensate evaporator, the unit's drain must have an outlet to an appropriate drainage area or container
OPERATION
The Mark V refrigerator unit is designed and tested to maintain an operational temperature between 36°F and 40°F, while the freezer unit is designed and tested to maintain an operational temperature between 0°F and 10°F
Do not place hot pans on the blue ABS liner Do not load storage area so as to restrict the air flow Overloading will result in a loss of temperature
Do not throw items into the storage area Care must be taken not to damage the blower coil or the interior of the cabinet Continuous opening and closing of the doors or drawers will hamper the unit's ability to maintain optimum refrigeration temperature