Defy ELECTRO MECHANICAL CONTROLS Operating Instructions Manual

The electro-Mechanical controls comprise of :
1. A Mode selector (Upper control)
2. A Thermostat ( Lower control)
FAN ONLY
1. Select ‘FAN ONLY’ on the selector
2. In this mode , the indoor fan circulates ambient air throughout the room without engaging heating or cooling modes.
COOLING
1. Select a ‘COOL’ setting on the thermostat
2. Select a ‘HIGH or LOW COOL’ on the selector.
3. In this mode The unit will cool, dehumidify, filter and circulate the room air with the fan running continuously at the selected mode.
HEATING
1. Select a ‘HEAT’ setting on the thermostat
2. Select a ‘HIGH or LOW HEAT’ on the selector.
3. In this mode The unit will heat, dehumidify, filter and circulate the room air with the fan running continuously at the selected mode.
NOTE:
The heating information does not apply to
Electro- Mechanical and Electronic
“Cooling Only” models.
AIRCONDITIONER OPERATING INSTRUCTIONS
Dear Customer,
Defy air conditioners are designed to give efficient cooling and heating for your personal comfort. They are easy to operate and require little maintenance. It is important that you read these instructions carefully in order to familiarise yourself with the unit. We suggest that the service record which can be found on the other side of this pamphlet, be completed each time the unit is inspected. Keep this pamphlet in a safe place in order that compliance with section 4 of the warranty can be indicated.
Rating conditions
Defy air conditioners comply with SABS 1125 : 1996. Specifi­cation Room Air conditioners and heat pumps are tested and rated to SABS ISO 5151 at standard test conditions T1 at 230V 50 Hz.
Temperature of air entering indoor side
Dry bulb 27°C - Wet bulb 19°C
Temperature of air entering outdoor side
Dry bulb 35°C - Wet bulb 24°C
The Electronic controls comprise of:
1. A Heating / Cooling mode selector with an ON pad, a pilot light and an automatic change over thermostat.
2. A Fan speed selector with an ON pad and fan speed indicator lights.
OPERATION
1. Set the THERMOSTAT to heating or cooling
2. Press the ON pad next to the thermostat to start.
3. Press the FAN SPEED ON pad and by pressing repeatedly, select the desired fan speed.
Only High and Medium fan speeds may be selected during heating mode on CWC models.
4. To switch the unit off, press the OFF pad.
5. To select FAN ONLY mode, press the thermostat ON pad again or switch the unit off and restart by pressing the FAN ON pad.
The control memorises the last setting. Press the ther­mostat ON pad and the unit will resume operation at the previously selected temperature and fan speed.
A No-Volt cut out with manual re-set prevents the unit from re-starting after a power failure. A flickering thermostat pilot light, indicates that the unit has switched off due to a voltage problem. Please call an Authorised Dealer or have the power supply checked by a qualified electrician. A compressor start –time delay prevents immediate start up in an unbalanced condition after the unit has been switched off. This time delay is about 3 minutes .
OPERATING INSTRUCTIONS FOR ELECTRO MECHANICAL CONTROLS
OPERATING INSTRUCTIONS FOR ELECTRONIC CONTROLS
HEAT
THERMOSTAT
ON
ON
COOL
FAN SPEED
HIGH
MED
LOW
OFF
COOL HEAT
FAN ONLY
LOW COOL
HIGH HEAT
LOW HEAT
SELECTOR
HIGH COOL
OFF
Airflow direction.
The grille may be adjusted to deflect the airflow vertically by moving the louvre blades and horizontally by adjusting the deflectors left or right.
Fresh air control. ( Not applicable to models AXS 09 and AXS 13 Console airconditioners )
The Silhouette models are equipped with a fresh air vent. The knob is located on the bottom of the left hand side panel. Pull the knob towards you to close the vent or push the knob away from you to open the vent. In the closed position, the room air is re-circulated.
PULL TO CLOSE THE VENT
PUSH TO OPEN THE VENT