DeDietrich Innovens MCA 28 BIC, Innovens MCA 25 BIC User Manual

Page 1
Innovens
EN
Wall-hung gas condensing boilers
MCA 35
User Guide
300022163-001-01
Page 2
1 Introduction ................................................................................................4
1.1 Symbols used .......................................................4
1.2 Abbreviations ........................................................4
1.3 General ..................................................................5
1.3.1 Manufacturer's liability .............................................5
1.3.2 Installer's liability .....................................................5
1.3.3 User's liability ..........................................................5
1.4 Certifications .........................................................6
2 Safety instructions and recommendations ..............................................7
2.1 Safety instructions ...............................................7
2.2 Recommendations ................................................8
3 Description ..................................................................................................9
3.1 Operating principle ...............................................9
3.1.1 Gas/air setting .........................................................9
3.1.2 Combustion .............................................................9
3.2 Main parts ............................................................10
3.3 Control panel .......................................................11
3.3.1 Description of the keys ..........................................11
3.3.2 Description of the display ......................................12
3.3.3 Browsing in the menus ..........................................15
4 Operating the boiler .................................................................................16
4.1 Commissioning the boiler ..................................16
4.2 Reading out measured values ...........................16
4.3 Changing the settings ........................................18
4.3.1 Setting the set point temperatures ........................18
4.3.2 Selecting the operating mode ...............................19
4.3.3 Forcing domestic hot water production .................20
4.3.4 Setting the contrast and lighting on the
display ...................................................................20
4.3.5 Setting the time and date ......................................21
4.3.6 Selecting a timer programme ................................21
4.3.7 Customising a timer programme ...........................22
1
15/06/12 - 300022163-001-01
Page 3
4.4 Installation shutdown .........................................24
4.5 Frost protection ..................................................24
5 Checking and maintenance .....................................................................26
5.1 General instructions ...........................................26
5.2 Periodic checks ..................................................26
5.3 Filling the system ...............................................27
5.4 Bleeding the heating system .............................29
5.5 Draining the installation .....................................31
6 Troubleshooting .......................................................................................32
6.1 Anti-hunting ........................................................32
6.2 Messages (Code type Bxx or Mxx) ....................32
6.3 Faults (Code type Lxx or Dxx) ...........................34
7 Technical specifications ..........................................................................40
7.1 Technical specifications ....................................40
8 Energy savings .........................................................................................41
8.1 Energy-saving advice .........................................41
8.2 Recommendations ..............................................41
9 Warranty ....................................................................................................42
9.1 General ................................................................42
9.2 Warranty terms ...................................................42
Contents
2
15/06/12 - 300022163-001-01
Page 4
3
15/06/12 - 300022163-001-01
Page 5
1 Introduction
1.1 Symbols used
In these instructions, various danger levels are employed to draw the user's attention to particular information. In so doing, we wish to safeguard the user's safety, obviate hazards and guarantee correct operation of the appliance.
DANGER
Risk of a dangerous situation causing serious physical injury.
WARNING
Risk of a dangerous situation causing slight physical injury.
CAUTION
Risk of material damage.
Signals important information.
¼ Signals a referral to other instructions or other pages in the instructions.
1.2 Abbreviations
4 3CE: Collective conduit for sealed boiler
4 DHW: Domestic hot water
4 Hi: Lower heating value LHV (Nett)
4 Hs: Higher heating value HHV (Gross)
4 PPS: Polypropylene hardly inflammable
4 PCU: Primary Control Unit - PCB for managing burner operation
4 PSU: Parameter Storage Unit - Parameter storage for PCBs
PCU and SU
4 SCU: Secondary Control Unit - control panel PCB
4 SU: Safety Unit - Safety PCB
4 3WV: 3-way valve
MCA 35
1. Introduction
15/06/12 - 300022163-001-01
4
Page 6
1.3 General
1.3.1. Manufacturer's liability
Our products are manufactured in compliance with the requirements of the various applicable European Directives. They are therefore
delivered with [ marking and all relevant documentation.
In the interest of customers, we are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice.
Our liability as the manufacturer may not be invoked in the following cases:
4 Failure to abide by the instructions on using the appliance.
4 Faulty or insufficient maintenance of the appliance.
4 Failure to abide by the instructions on installing the appliance.
1.3.2. Installer's liability
The installer is responsible for the installation and inital start up of the appliance. The installer must respect the following instructions:
4 Read and follow the instructions given in the manuals provided
with the appliance.
4 Carry out installation in compliance with the prevailing legislation
and standards.
4 Perform the initial start up and carry out any checks necessary.
4 Explain the installation to the user.
4 If a maintenance is necessary, warn the user of the obligation to
check the appliance and maintain it in good working order.
4 Give all the instruction manuals to the user.
1.3.3. User's liability
To guarantee optimum operation of the appliance, the user must respect the following instructions:
4 Read and follow the instructions given in the manuals provided
with the appliance.
4 Call on qualified professionals to carry out installation and initial
start up.
4 Get your installer to explain your installation to you.
4 To carry out inspections and maintenance required by a qualified
professional.
4 Keep the instruction manuals in good condition close to the
appliance.
1. Introduction
MCA 35
5
15/06/12 - 300022163-001-01
Page 7
This appliance is not intended to be used by persons (including children) whose physcial, sensory or mental capacity is impaired or persons with no experience or knowledge, unless they have the benefit, through the intermediary of a person responsible for their safety, of supervision or prior instructions regarding use of the appliance. Care should be taken to ensure that children do not play with the appliance.
1.4 Certifications
CE identification no
PIN 0063BT3444
NOx classification
5 (EN 297 pr A3, EN 656)
Type of connection
Chimney: B23
(1)
, B
23P
(1)
, B
33
Flue gas outlet: C
13(x)
, C
33(x)
, C
43(x)
, C53 ,
C
63(x)
, C
83(x)
, C
93(x)
(1) IP20
MCA 35 1. Introduction
15/06/12 - 300022163-001-01
6
Page 8
2 Safety instructions and
recommendations
2.1 Safety instructions
DANGER
If you smell gas:
1. Do not use a naked flame, do not smoke, do not operate electrical contacts or switches ( doorbell, light, motor, lift, etc..).
2. Shut off the gas supply.
3. Open the windows.
4. Evacuate the premises.
5. Call your fitter.
DANGER
If you smell flue gases:
1. Switch the appliance off.
2. Open the windows.
3. Evacuate the premises.
4. Call your fitter.
WARNING
Depending on the settings of the appliance:
4 The temperature of the flue gas conduits may exceed
60°C.
4 The temperature of the radiators may reach 85°C.
4 The temperature of the domestic hot water may reach
65°C.
CAUTION
Do not neglect to service the appliance: 4 For completely safe and optimum operation, you
must have your boiler regularly serviced by an approved installer.
2. Safety instructions and recommendations MCA 35
7
15/06/12 - 300022163-001-01
Page 9
2.2 Recommendations
WARNING
Only qualified professionals are authorised to work on the appliance and the installation.
4 Regularly check the water pressure in the installation (minimum
pressure 0,8 bar, recommended pressure between 1,5 and 2,0 bar).
4 Keep the appliance accessible at all times.
4 Never remove or cover labels and rating plates affixed to the
appliance. Labels and rating plates must be legible throughout the entire lifetime of the appliance.
4 The appliance should be on Summer or Antrifreeze mode rather
than switched off to guarantee the following functions:
- Anti blocking of pumps
- Frost protection
MCA 35 2. Safety instructions and recommendations
15/06/12 - 300022163-001-01
8
Page 10
3 Description
3.1 Operating principle
3.1.1. Gas/air setting
The casing fitted to the boiler is also used as an air box. Air is sucked in by the fan and gas injected into the venturi by the fan intake. The fan rotation speed is set according to the settings parameters, the thermal energy requirement and the temperatures measured by the temperature sensors. The gas and air are mixed in the venturi. The gas/air ratio ensures that the quantities of gas and air are adjusted to each other. This provides optimum combustion on the entire output range. The gas/air mixture is fed into the burner on top of the exchanger.
3.1.2. Combustion
The burner heats the heating water circulating in the heat exchanger. At a return temperature lower than around 55°C, the flue gases cool down to a temperature lower than the dew point, thus causing the condensation of the water vapour contained in the flue gases in the back side of the heat exchanger. The heat released during this condensation process (the latent heat or condensing heat) is also transferred to the heating water. The cooled combustion gases are evacuated via the combustion gas outlet flue. The condensation water is evacuated via a siphon.
3. Description MCA 35
9
15/06/12 - 300022163-001-01
Page 11
3.2 Main parts
1
Flue gas discharge pipe
2
Casing/air box
3
Flue gas measuring point
4
Mixer pipe
5
Heating flow hose
6
Air intake silencer
7
Box for the control PCBs
8
Combined venturi and gas valve unit
9
Flow end hydroblock
10
Safety valve outlet pipe
11
Siphon
12
Control panel
13
Shunt pump
14
Return end hydroblock
15
3-way valve
16
Condensate receiver tank
17
Fan
18
Heat exchanger (Heating circuit)
19
Ignition/ionization electrode
20
Air intake
T001964-D
2
14
15
13
16
17
18
19
3
4
5
6
7
8
9
10
11
12
1 20
MCA 35 3. Description
15/06/12 - 300022163-001-01
10
Page 12
3.3 Control panel
3.3.1. Description of the keys
A
Temperature setting key (heating, DHW, swimming pool)
B
Operating mode selection key
C
DHW override key
D
Key to access the parameters reserved for the installer
E
Keys on which the function varies as and when selections are made
F
Rotary setting button:
4 Turn the rotary button to scroll through the menus or
modify a value
4 Press the rotary button to access the selected menu
or confirm a value modification
A000866-A
bar
STD
t
0 2 4 6 8 10 12 14 16 18 22 2420
p
b
AUTO
x
c
r
j
M
g
m
A
B
C
D
E
F
(
'
3. Description MCA 35
11
15/06/12 - 300022163-001-01
Page 13
3.3.2. Description of the display
n
Key functions
>
Access to the various menus
(
Used to scroll through the menus
'
Used to scroll through the parameters
?
The symbol is displayed when help is available
f
Used to display the curve of the parameter selected
STD
Reset of the time programmes
b
Selection of comfort mode or selection of the days to be programmed
v
Selection of reduced mode or deselection of the days to be programmed
j
Back to the previous level
ESC
Back to the previous level without saving the modifications made
t
Manual reset
n
Flame output level
C002705-A
The whole symbol flashes: The burner starts up but the flame is not yet present
C002704-A
Part of the symbol flashes: Output is increasing
C002703-A
Steady symbol: The required output has been reached
C002702-A
Part of the symbol flashes: Output is dropping
bar
r
STD
(
'
t
0 2 4 6 8 10 12 14 16 18 22 2420
C002696-A
p
b
AUTO
x
c
r
j
L
g
m
bar
STD
t
0 2 4 6 8 10 12 14 16 18 22 2420
C002701-B
p
b
AUTO
x
c
r
j
M
g
m
MCA 35 3. Description
15/06/12 - 300022163-001-01
12
Page 14
n
Solar (If connected)
u
The solar load pump is running
L000200-A
The top part of the tank is reheated to the tank set point
L000201-A
The entire tank is reheated to the tank set point
L000198-A
The entire tank is reheated to the solar tank set point
L000199-A
The tank is not loaded - Presence of the solar control system
n
Operating modes
p
Summer mode: The heating is off. Domestic hot water continues to be produced
b
WINTER mode: Heating and domestic hot water working
AUTO
Operation in automatic mode according to the timer programme
x
Comfort mode: The symbol is displayed when a DAY override (comfort) is activated
4 Flashing symbol: Temporary override
4 Steady symbol: Permanent override
m
Reduced mode: The symbol is displayed when a NIGHT override (reduced) is activated
4 Flashing symbol: Temporary override
4 Steady symbol: Permanent override
g
Holiday mode: The symbol is displayed when a HOLIDAY override (antifreeze) is activated
4 Flashing symbol: Holiday mode programmed
4 Steady symbol: Holiday mode active
m
Manual mode
bar
STD
t
0 2 4 6 8 10 12 14 16 18 22 2420
L000197-A
p
b
AUTO
x
c
r
j
M
g
m
bar
STD
t
0 2 4 6 8 10 12 14 16 18 22 2420
C002697-B
p
b
AUTO
x
c
r
j
M
g
m
bar
STD
t
0 2 4 6 8 10 12 14 16 18 22 2420
C002698-B
p
b
AUTO
x
c
r
j
M
g
m
3. Description MCA 35
13
15/06/12 - 300022163-001-01
Page 15
n
System pressure
bar
Pressure indicator: The symbol is displayed when a water pressure sensor is connected.
4 Flashing symbol: The water pressure is insufficient.
4 Steady symbol: The water pressure is sufficient.
l
Water pressure level
4 R : 0,9 to 1,1 bar 4 E : 1,2 to 1,5 bar 4 Z : 1,6 to 1,9 bar 4 A : 2,0 to 2,3 bar 4 l : > 2,4 bar
n
Domestic Hot Water override
A bar is displayed when a DHW override is activated:
4 Flashing bar: Temporary override
4 Steady bar: Permanent override
n
Other information
r
The symbol is displayed when domestic hot water production is running.
w
Valve indicator: The symbol is displayed when a 3-way valve is connected.
4 x : 3-way valve opens 4 c : 3-way valve closes
M
The symbol is displayed when the pump is operating.
Name of the circuit for which the parameters are displayed.
bar
STD
t
0 2 4 6 8 10 12 14 16 18 22 2420
C002708-A
p
b
AUTO
x
c
r
j
M
g
m
bar
STD
t
0 2 4 6 8 10 12 14 16 18 22 2420
C002707-A
p
b
AUTO
x
c
r
j
M
g
m
bar
STD
t
0 2 4 6 8 10 12 14 16 18 22 2420
C002699-B
p
b
AUTO
x
c
r
j
M
g
m
MCA 35 3. Description
15/06/12 - 300022163-001-01
14
Page 16
3.3.3. Browsing in the menus
1. To select the desired menu, turn the rotary button.
2. To access the menu, press the rotary button. To go back to the previous display, press the key j.
3. To select the desired parameter, turn the rotary button.
4. To modify the parameter, press the rotary button. To go back to the previous display, press the key j.
5. To modify the parameter, turn the rotary button.
6. To confirm, press the rotary button.
To cancel, press key
h
.
7. To go back to the main display, press key j2 times.
It is possible to use the ( and ' keys instead of the rotary button.
bar
1
1
2
2
r
c
STD
(
'
t
v
0 2 4 6 8 10 12 14 16 18 22 2420
p
b
AUTO
x
c
r
j
L
g
m
#MEASURES
#CHOICE TIME PROG.
#TIME PROGRAM #SETTING #TIME .DAY
a
C002220-B-04
bar
1
1
2
2
r
c
STD
(
'
t
v
0 2 4 6 8 10 12 14 16 18 22 2420
p
b
AUTO
x
c
r
j
L
g
m
CURRENT PROG.B
CURRENT PROG.C
P2
P3
a
C002221-C-04
bar
1
1
2
2
r
c
STD
(
'
t
v
0 2 4 6 8 10 12 14 16 18 22 2420
p
b
AUTO
x
c
r
j
L
g
m
CURRENT PROG.C
"Choice of the timeprogram applied C"
P4
a
C002222-C-04
bar
1
1
2
2
r
c
STD
(
'
t
v
0 2 4 6 8 10 12 14 16 18 22 2420
p
b
AUTO
x
c
r
j
M
g
m
LUNDI 11:45
C002224-D-04
2x
3. Description MCA 35
15
15/06/12 - 300022163-001-01
Page 17
4 Operating the boiler
4.1 Commissioning the boiler
1. Check the water pressure in the installation shown on the control panel display.
If the water pressure is lower than 0,8 bar, more water should be added. If necessary, top up the water level in the heating system (recommended hydraulic pressure between 1,5 and 2,0 bar).
¼
See chapter: "Filling the system", page 27
2. Open the gas valve on the boiler.
3. Turn on the boiler using the on/off switch.
4. The first time the boiler is powered up, the #LANGUAGE menu is displayed. Select the desired language by turning the rotary button.
5. To confirm, press the rotary button. The boiler will begin an automatic venting-programme (which lasts approx. 3 minutes) and will do this every time the power supply is isolated. If there is a problem, the error is displayed on the screen.
4.2 Reading out measured values
The various values measured by the appliance are displayed in the #MEASURES menu.
1. To access user level: Press the > key.
2. Select the menu #MEASURES.
4
Turn the rotary button to scroll through the menus or modify a value.
4 Press the rotary button to access the selected menu
or confirm a value modification.
¼
For a detailed explanation of menu browsing, refer
to the chapter: "Browsing in the menus", page 15.
C002366-B
Français - Deutsch - English ­Italiano - Espanol - Nederlands
- Pycck - Polski - Türk -
bar
1
1
2
2
r
c
STD
(
'
t
v
0 2 4 6 8 10 12 14 16 18 22 2420
p
b
x
c
r
g
m
ÿ
LANGUE FRANCAIS
C002286-C
bar
1
1
2
2
r
c
STD
(
'
t
v
0 2 4 6 8 10 12 14 16 18 22 2420
p
b
AUTO
x
c
r
j
M
g
m
SUNDAY 11:45
C002219-D-04
MCA 35 4. Operating the boiler
15/06/12 - 300022163-001-01
16
Page 18
User level - Menu #MEASURES
Parameter Description Unit
OUTSIDE TEMP.
Outside temperature °C
ROOMTEMP. A
(1)
Room temperature of circuit A °C
ROOMTEMP. B
(1)
Room temperature of circuit B °C
ROOMTEMP. C
(1)
Room temperature of circuit C °C
BOILER TEMP.
Water temperature in the boiler °C
PRESSURE
Water pressure in the installation bar
WATER TEMP.
(1)
Water temperature in the DHW tank °C
INST DWH TEMP.
(1)
Instant hot water temperature °C
STOR.TANK.TEMP
(1)
Water temperature in the storage tank °C
DCW TEMPERATURE
Domestic cold water temperature °C
SWIMMING P.T.B
(1)
Water temperature of the swimming pool on circuit B °C
SWIMMING P.T.C
(1)
Water temperature of the swimming pool on circuit C °C
OUTLET TEMP. B
(1)
Temperature of the flow water in circuit B °C
OUTLET TEMP. C
(1)
Temperature of the flow water in circuit C °C
SYSTEM TEMP.
(1)
Temperature of the system flow water if multi-generator °C
T.DHW BOTTOM
(1)
Water temperature in the bottom of the DHW tank °C
TEMP.TANK AUX
(1)
Water temperature in the second DHW tank connected to the AUX circuit °C
DHW A TEMP.
(1)
Water temperature in the second DHW tank connected to circuit A °C
BACK TEMP Temperature of the boiler return water °C
WIND SPEED Fan rotation speed rpm
POWER Instantaneous boiler output (0%: Burner off or running at minimum output) %
CURRENT (µA) Ionization current µA
NB IMPULS. Number of burner starts (not restartable)
The meter is incremented by 8 every 8 start-ups
RUNTIME Number of burner operation hours (not restartable)
The meter is incremented by 2 every 2 hours
h
IN 0-10V
(1)
Voltage at input 0-10 V V
SEQUENCE
Control system sequence
CTRL Software control number
(1) The parameter is only displayed for the options, circuits or sensors actually connected.
4. Operating the boiler MCA 35
17
15/06/12 - 300022163-001-01
Page 19
4.3 Changing the settings
4.3.1. Setting the set point temperatures
To set the various heating, DHW and swimming pool temperatures, proceed as follows:
1. Press the C key.
2. To select the desired parameter, turn the rotary button.
3. To modify the parameter, press the rotary button. To go back to the previous display, press the key j.
4. To modify the parameter, turn the rotary button.
5. To confirm, press the rotary button.
To cancel, press key
h
.
Menu C
Parameter Adjustment range Description Factory setting
DAY TEMP. A
5 to 30 °C Desired room temperature in comfort periods on circuit A 20 °C
NIGHT TEMP. A
5 to 30 °C Desired room temperature in reduced periods on circuit A 16 °C
DAY TEMP. B
(1)
5 to 30 °C Desired room temperature in comfort periods on circuit B 20 °C
NIGHT TEMP. B
(1)
5 to 30 °C Desired room temperature in reduced periods on circuit B 16 °C
DAY TEMP. C
(1)
5 to 30 °C Desired room temperature in comfort periods on circuit C 20 °C
NIGHT TEMP. C
(1)
5 to 30 °C Desired room temperature in reduced periods on circuit C 16 °C
WATER TEMP.
(1)
10 to 80 °C Desired domestic hot water temperature in the DHW circuit 55 °C
WATER T.NIGHT
(1)
(2)
10 to 80 °C Set tank temperature, night programme 10 °C
TEMP.TANK AUX
(1)
10 to 80 °C Desired domestic hot water temperature in the auxiliary circuit 55 °C
AUX.TANK T.NIGHT
(1)(2)
10 to 80 °C Set tank temperature, night programme 10 °C
DHW A TEMP.
(1)
10 to 80 °C Desired domestic hot water temperature in circuit A 55 °C
A.TANK T.NIGHT
(1)
(2)
10 to 80 °C Set tank temperature, night programme 10 °C
SWIMMING P.T.B
(1)
5 to 39 °C Desired temperature for swimming pool B 20 °C
SWIMMING P.T.C
(1)
5 to 39 °C Desired temperature for swimming pool C 20 °C
(1) The parameter is only displayed for the options, circuits or sensors actually connected. (2) The parameter is only displayed if INSTALLATION parameter is set to EXTENDED
MODE
C002266-A
MCA 35 4. Operating the boiler
15/06/12 - 300022163-001-01
18
Page 20
4.3.2. Selecting the operating mode
To select an operating mode, proceed as follows:
1. Press the MODE key.
2. To select the desired parameter, turn the rotary button.
3. To modify the parameter, press the rotary button. To go back to the previous display, press the key j.
4. To modify the parameter, turn the rotary button.
5. To confirm, press the rotary button.
To cancel, press key h.
Menu MODE
Parameter Adjustment range Description Factory setting
AUTOMATIQUE
The comfort ranges are determined by the timer programme.
DAY
7/7, xx:xx Comfort mode is forced until the time indicated or all the time (7/7). Present time + 1
hour
NIGHT
7/7, xx:xx Reduced mode is forced until the time indicated or all the time
(7/7).
Present time + 1 hour
HOLIDAYS
7/7, 1 to 365 The antifreeze mode is active on all boiler circuits.
Number of days' holiday: xx
(1)
heating OFF: xx:xx
(1)
Restarting: xx:xx
(1)
Present date + 1 day
SUMMER
The heating is off. Domestic hot water continues to be produced.
MANUEL
The generator operates according to the set point setting. All of the pumps operate. Option of setting the set point by simply turning the rotary button.
FORCE AUTO
(2)
YES / NO An operating mode override is activated on the remote control
(option). To force all circuits to run on AUTOMATIQUE mode, select
YES.
(1) The start and end days and the number of days are calculated in relation to each other. (2) The parameter is only displayed if a room sensor is connected.
MODE
C002267-A
4. Operating the boiler MCA 35
19
15/06/12 - 300022163-001-01
Page 21
4.3.3. Forcing domestic hot water production
To force domestic hot water production, proceed as follows:
1. Press the r key.
2. To select the desired parameter, turn the rotary button.
3. To modify the parameter, press the rotary button. To go back to the previous display, press the key j.
4. To modify the parameter, turn the rotary button.
5. To confirm, press the rotary button.
To cancel, press key h.
Menu r
Parameter Description Factory setting
AUTOMATIQUE
The domestic hot water comfort ranges are determined by the timer programme.
COMFORT
Domestic hot water comfort mode is forced until the time indicated or all the time (7/7). Present time + 1 hour
4.3.4. Setting the contrast and lighting on the
display
1. To access user level: Press the > key.
2. Select the menu #SETTING.
4
Turn the rotary button to scroll through the menus or modify a value.
4 Press the rotary button to access the selected menu
or confirm a value modification.
¼
For a detailed explanation of menu browsing, refer
to the chapter: "Browsing in the menus", page 15.
3. Set the following parameters:
User level - Menu #SETTING
Parameter Adjustment range Description Factory setting Customer setting
CONTRAST DISP.
Adjusting the display contrast.
BACK LIGHT COMFORT
The screen is illuminated continuously in daytime periods.
ECO
ECO
The screen is illuminated for 2 minutes whenever pressed.
MODE
C002268-A
bar
1
1
2
2
r
c
STD
(
'
t
v
0 2 4 6 8 10 12 14 16 18 22 2420
p
b
AUTO
x
c
r
j
M
g
m
SUNDAY 11:45
C002219-D-04
MCA 35 4. Operating the boiler
15/06/12 - 300022163-001-01
20
Page 22
4.3.5. Setting the time and date
1. To access user level: Press the > key.
2. Select the menu #TIME .DAY.
4 Turn the rotary button to scroll through the menus or
modify a value.
4 Press the rotary button to access the selected menu
or confirm a value modification.
¼
For a detailed explanation of menu browsing, refer
to the chapter: "Browsing in the menus", page 15.
3. Set the following parameters:
User level - Menu #TIME .DAY
(1)
Parameter Adjustment range Description Factory setting Customer setting
HOURS
0 to 23 Hours setting
MINUTE
0 to 59 Minutes setting
DAY
Monday to Sunday Setting the day of the week
DATE
1 to 31 Day setting
MONTH
January to December Month setting
YEAR
2008 to 2099 Year setting
SUM. TIME: AUTO
automatic switch to summer time on the last Sunday in March and back to winter time on the last Sunday in October.
AUTO
MANU
for countries where the time change is done on other dates or is not in use.
(1) According to the configuration
4.3.6. Selecting a timer programme
1. To access user level: Press the > key.
2. Select the menu #CHOICE TIME PROG..
4
Turn the rotary button to scroll through the menus or modify a value.
4 Press the rotary button to access the selected menu
or confirm a value modification.
¼
For a detailed explanation of menu browsing, refer
to the chapter: "Browsing in the menus", page 15.
3. To select the desired parameter.
4. Assign the desired timer programme (P1 to P4) to the circuit with the rotary button.
bar
1
1
2
2
r
c
STD
(
'
t
v
0 2 4 6 8 10 12 14 16 18 22 2420
p
b
AUTO
x
c
r
j
M
g
m
SUNDAY 11:45
C002219-D-04
bar
1
1
2
2
r
c
STD
(
'
t
v
0 2 4 6 8 10 12 14 16 18 22 2420
p
b
AUTO
x
c
r
j
M
g
m
SUNDAY 11:45
C002219-D-04
4. Operating the boiler
MCA 35
21
15/06/12 - 300022163-001-01
Page 23
User level - Menu #CHOICE TIME PROG.
Parameter Adjustment range Description
CURRENT PROG.A
P1 / P2 / P3 / P4 Comfort programme activated
(Circuit A)
CURRENT PROG.B
P1 / P2 / P3 / P4 Comfort programme activated
(Circuit B)
CURRENT PROG.C
P1 / P2 / P3 / P4 Comfort programme activated
(Circuit C)
4.3.7. Customising a timer programme
1. To access user level: Press the > key.
2. Select the menu #TIME PROGRAM.
4 Turn the rotary button to scroll through the menus or
modify a value.
4 Press the rotary button to access the selected menu
or confirm a value modification.
¼
For a detailed explanation of menu browsing, refer
to the chapter: "Browsing in the menus", page 15.
3. To select the desired parameter.
User level - Menu #TIME PROGRAM
Parameter Time schedule Description
TIME PROG.A PROG P2 A
PROG P3 A PROG P4 A
Timer programme for circuit A
TIME PROG.B PROG P2 B
PROG P3 B PROG P4 B
Timer programme for circuit B
TIME PROG.C PROG P2 C
PROG P3 C PROG P4 C
Timer programme for circuit C
TIME PROG.DHW
DHW circuit timer programme
TIME PROG.AUX
Auxiliary circuit timer programme
4. To select a timer programme to be modified.
5.
To select to days for which the timer programme is to be modified:
Turn the rotary button to the left until you reach the day desired. To confirm, press the rotary button.
bar
1
1
2
2
r
c
STD
(
'
t
v
0 2 4 6 8 10 12 14 16 18 22 2420
p
b
AUTO
x
c
r
j
M
g
m
SUNDAY 11:45
C002219-D-04
bar
1
1
2
2
r
c
STD
(
'
t
v
0 2 4 6 8 10 12 14 16 18 22 2420
p
b
AUTO
x
c
r
j
L
g
m
PROG P2 C Mo Tu We Th Fr Sa Su "Display of the timeprogram. To continuepush on the button"
a
C002228-B-04
MCA 35
4. Operating the boiler
15/06/12 - 300022163-001-01
22
Page 24
6.b : Day selection Press key b / v until the symbol b is displayed. Turn the rotary button to the right to select the day(s) desired.
v
: Cancelling the day selection Press key b / v until the symbol v is displayed. Turn the rotary button to the right to cancel selection of the relevant
day(s).
7. When the days desired for the programme have been selected, press the rotary button to confirm.
8.
To define the timer ranges for the comfort mode and reduced mode:
Turn the rotary button to the left until 0:00 is displayed. The first segment of the graphic bar for the timer programme flashes.
9.b : Comfort mode selection Press key b / v until the symbol b is displayed. To select a comfort time range, turn the rotary button to the right.
v
: Reduced mode selection Press key b / v until the symbol v is displayed. To select a reduced time range, turn the rotary button to the right.
10.When the times for the comfort mode have been selected, press the rotary button to confirm.
User level - Menu #TIME PROGRAM
Day Comfort periods / Filling enabled:
P1 _______________
P2 _______________ P3 _______________ P4 _______________
TIME PROG.A
Monday 6:00 to 22:00
Tuesday 6:00 to 22:00
Wednesday 6:00 to 22:00
Thursday 6:00 to 22:00
Friday 6:00 to 22:00
Saturday 6:00 to 22:00
Sunday 6:00 to 22:00
TIME PROG.B
Monday 6:00 to 22:00
Tuesday 6:00 to 22:00
Wednesday 6:00 to 22:00
Thursday 6:00 to 22:00
Friday 6:00 to 22:00
Saturday 6:00 to 22:00
Sunday 6:00 to 22:00
TIME PROG.C
Monday 6:00 to 22:00
Tuesday 6:00 to 22:00
Wednesday 6:00 to 22:00
Thursday 6:00 to 22:00
Friday 6:00 to 22:00
Saturday 6:00 to 22:00
Sunday 6:00 to 22:00
bar
1
1
2
2
r
c
STD
(
'
t
v
0 2 4 6 8 10 12 14 16 18 22 2420
p
b
AUTO
x
c
r
j
L
g
m
PROG P2 C Mo Tu
We Th Fr Sa Su
"Select the days to program"
a
C002229-C-04
bar
1
1
2
2
r
c
STD
(
'
t
v
0 2 4 6 8 10 12 14 16 18 22 2420
p
b
AUTO
x
c
r
j
L
g
m
PROG P2 C Mo Tu
We Th Fr Sa Su
Set the time program.
a
C002230-E-04
06:00
06:00
4. Operating the boiler MCA 35
23
15/06/12 - 300022163-001-01
Page 25
User level - Menu #TIME PROGRAM
Day Comfort periods / Filling enabled:
P1 _______________
P2 _______________ P3 _______________ P4 _______________
TIME PROG.DHW
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
TIME PROG.AUX
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
4.4 Installation shutdown
CAUTION
Do not switch off the mains supply to the appliance. If the central heating system is not used for a long period, we recommend activating the HOLIDAYS mode (to ensure the anti-grip of the heating pump).
4.5 Frost protection
When the heating water temperature in the boiler falls by too much, the integrated protection system in the boiler starts up. This protection functions as follows:
4 If the water temperature is lower than 7°C, the heating pump starts
up.
4 If the water temperature is lower than 4°C, the boiler starts up.
4 If the water temperature is higher than 10°C, the boiler shuts down
and the circulation pump continues to run for a short time.
MCA 35
4. Operating the boiler
15/06/12 - 300022163-001-01
24
Page 26
CAUTION
4 The antifreeze protection does not function if the
appliance is switched off.
4 The integrated protection system only protects the
boiler, not the installation. To protect the installation, set the appliance to HOLIDAYS mode.
The HOLIDAYS mode protects:
4 The installation if the outside temperature is lower than 3°C
(factory setting).
4 The room temperature if a remote control is connected and the
room temperature is lower than 6 °C (factory setting).
4 The domestic hot water tank if the tank temperature is lower
than 4 °C (the water is reheated to 10 °C).
To configure the holidays mode: ¼ See chapter: "Selecting the operating mode", page 19.
4. Operating the boiler MCA 35
25
15/06/12 - 300022163-001-01
Page 27
5 Checking and maintenance
5.1 General instructions
The boiler does not require a lot of maintenance. Nevertheless, we recommend having the boiler inspected and serviced at regular intervals.
4 Maintenance and cleaning of the boiler must be carried out at least
once a year by a qualified technician.
4 Have the flues swept at least once a year or more, depending on
the regulations in force in your country.
CAUTION
4 Maintenance operations must be done by a qualified
engineer.
4 We recommend taking out a maintenance contract.
4 Only original spare parts must be used.
4 Make certain that the flues and chimneys are
connected, in good condition and not blocked.
4 Do not modify nor block the condensate outlet(s).
4 If a neutralisation system is installed, follow the
instructions delivered with the neutralisation system for cleaning and servicing of this system.
The boiler displays a message whenever maintenance is necessary.
1. When the message, REVISION, is displayed, press ? to display the installer's telephone number (only if the installer has input this parameter).
2. Contact the fitter.
3. To carry out inspections and maintenance required by a qualified professional.
5.2 Periodic checks
4 Check the water pressure in the installation.
If the water pressure is lower than 0,8 bar, more water should be added. If necessary, top up the water level in the heating system (recommended hydraulic pressure between 1,5 and 2,0 bar).
¼ See chapter: "Filling the system", page 27.
bar
1
1
2
2
r
c
STD
(
'
t
v
0 2 4 6 8 10 12 14 16 18 22 2420
p
b
AUTO
x
c
r
j
M
g
m
SUNDAY 11:45
TEMP. : 68°
PCU COM.FAIL D27
C002302-D-04
MCA 35 5. Checking and maintenance
15/06/12 - 300022163-001-01
26
Page 28
4 Carry out a visual check for the presence of any water leaks.
4 Open and close the radiator valves several times a year (this
prevents the valves from seizing up).
4 Clean the outside of the boiler using a damp cloth and a light
detergent.
CAUTION
Only a qualified professional is authorised to clean the inside of the boiler.
5.3 Filling the system
1. Check the water pressure in the installation shown on the control panel display.
If the water pressure is lower than 0,8 bar, more water should be added. If necessary, top up the water level in the heating system (recommended hydraulic pressure between 1,5 and 2,0 bar).
2. Open the valves on all radiators connected to the heating system.
3. Set the heating set point to as low a temperature as possible.
4. Wait until the temperature drops below 40°C and the radiators seem cold before filling the central heating system.
T001507-B
1
2
3
4
T000181-B
1
2
3
4
T000181-B
T000185-A
5. Checking and maintenance MCA 35
27
15/06/12 - 300022163-001-01
Page 29
5. Open the cold water inlet and heating outlet valves.
6. Open the disconnector valves.
7. Close the disconnector valves when the manometer indicates a pressure of 2 bar.
When water is added, air gets into the heating system. Degas the installation. After the air has been vented, the water pressure can drop below the required level. Check the water pressure in the heating system. If the water pressure is lower than 0,8 bar, more water should be added.
8. After filling the installation, switch the boiler on.
Filling and bleeding the installation 2 times a year should be sufficient to obtain an adequate hydraulic pressure. If it is often necessary to top up the installation with water, contact your fitter.
T001620-A
T001618-A
1
2
T001619-A
2
1
2 bar
MCA 35 5. Checking and maintenance
15/06/12 - 300022163-001-01
28
Page 30
5.4 Bleeding the heating system
It is essential that you bleed any air in the calorifier, the conduits or the taps to prevent the annoying noises likely to be produced during heating or when tapping water. To do this, proceed as follows:
1. Open the valves on all radiators connected to the heating system.
2. Set the heating set point to as high a temperature as possible.
3. Wait until the radiators are hot.
4. Switch the boiler off.
5. Wait around 10 minutes until the radiators are cold.
6. Bleed the radiators. Start with the lower floors.
1
2
3
4
T000181-B
T000184-A
T000185-A
T000854-A
3
1
4
5
2
5. Checking and maintenance MCA 35
29
15/06/12 - 300022163-001-01
Page 31
7. Open the bleed connection using the bleed key provided whilst keeping a rag pressed against the connection.
8. Wait until water comes out of the bleed valve and then close the bleed connection.
CAUTION
The water may still be hot.
9. Switch on the boiler. A vent cycle of a duration of around 3 minutes is carried out automatically.
10.After venting, check whether the pressure in the installation is still sufficient.
If the water pressure is lower than 0,8 bar, more water should be added. If necessary, top up the water level in the heating system (recommended hydraulic pressure between 1,5 and 2,0 bar).
¼
See chapter: "Filling the system", page 27
11.Set the heating set point.
T000217-A
T000218-A
MCA 35 5. Checking and maintenance
15/06/12 - 300022163-001-01
30
Page 32
5.5 Draining the installation
It may become necessary to empty the water from the heating system when the radiators have to be replaced, should there be a major water leak or a risk of frost. To do this, proceed as follows:
1. Open the valves on all radiators connected to the heating system.
2. Switch off the boiler electrical power supply.
3. Wait around 10 minutes until the radiators are cold.
4. Connect an evacuation hose to the plug located at the lowest level. Place the end of the hose in a discharge sump or in a place where the water discharged from the valve can not do any damage.
5. Open the filling/draw-off valve on the heating system. Vent the heating installation.
WARNING
The water may still be hot.
6. When no more water comes out of the drainage plug, close the drainage valve.
1
2
3
4
T000181-B
T000185-A
T000858-A
5. Checking and maintenance MCA 35
31
15/06/12 - 300022163-001-01
Page 33
6 Troubleshooting
6.1 Anti-hunting
When the boiler is in Anti-short-cycle operating mode, the symbol ? flashes.
1. Press the "?" key. The message Operation assured when the restart temperature will be reached is displayed.
This message is not an error message but an item of information.
6.2 Messages (Code type Bxx or Mxx)
In the case of failure, the control panel displays a message and a corresponding code.
1. Make a note of the code displayed. The code is important for the correct and rapid diagnosis of the type of failure and for any technical assistance that may be needed.
2. Switch the boiler off and switch back on. The boiler starts up again automatically when the reason for the blocking has been removed.
3. If the code is displayed again, correct the problem by following the instructions in the table below:
Code
Messages Description Checking / solution
B00 BL.CRC.PSU
The PSU PCB is incorrectly configured
Parameter error on the PSU PCB
4 Contact the professional who takes care of
maintenance of the appliance
B01 BL.MAX BOILER
Maximum flow temperature exceeded
The water flow in the installation is insufficient
4 Check the circulation (direction, pump, valves)
B02 BL.HEATING SPEED
The increase in flow temperature has exceeded its maximum limit
The water flow in the installation is insufficient
4 Check the circulation (direction, pump, valves)
4 Check the water pressure
Sensor error
4 Contact the professional who takes care of
maintenance of the appliance
B07 BL.DT OUTL RET.
Maximum difference between the flow and return temperature exceeded
The water flow in the installation is insufficient
4 Check the circulation (direction, pump, valves)
4 Check the water pressure
Sensor error
4 Contact the professional who takes care of
maintenance of the appliance
MCA 35 6. Troubleshooting
15/06/12 - 300022163-001-01
32
Page 34
Code Messages Description Checking / solution
B08 BL.RL OPEN
The RL inlet on the PCU PCB terminal block is open
Parameter error
4 Contact the professional who takes care of
maintenance of the appliance
Bad connection
4 Contact the professional who takes care of
maintenance of the appliance
B09 BL.INV. L/N
4 Contact the professional who takes care of maintenance of the appliance
B10 B11
BL.BL INPUT OPEN
The BL inlet on the PCU PCB terminal block is open
The contact connected to the BL inlet is open
4 Contact the professional who takes care of
maintenance of the appliance
Parameter error
4 Contact the professional who takes care of
maintenance of the appliance
Bad connection
4 Contact the professional who takes care of
maintenance of the appliance
B13 BL. PCU COM
BL.COM PCU-D4
Communication error with the SCU PCB
Bad connection
4 Contact the professional who takes care of
maintenance of the appliance
SCU PCB not installed in the boiler
4 Contact the professional who takes care of
maintenance of the appliance
B14 BL.WATER MIS.
The water pressure is lower than 0,8 bar
Not enough water in the circuit
4 Top up the installation with water
B15 BL.GAS PRESS
Gas pressure too low Incorrect setting of the gas pressure switch on the SCU PCB
4 Check that the gas valve is fully opened
4 Contact the professional who takes care of
maintenance of the appliance
B16
BL.BAD SU
The SU PCB is not recognised Wrong SU PCB for this boiler
4 Contact the professional who takes care of
maintenance of the appliance
B17 BL.PCU ERROR
The parameters saved on the PCU PCB are impaired
Parameter error on the PCU PCB
4 Contact the professional who takes care of
maintenance of the appliance
B18 BL.BAD PSU
The PSU PCB is not recognised Wrong PSU PCB for this boiler
4 Contact the professional who takes care of
maintenance of the appliance
B19 BL.NO CONFIG
The boiler has not been configured
The PSU PCB has been changed
4 Contact the professional who takes care of
maintenance of the appliance
B21 BL. COM SU
Communication error between the PCU and SU PCBs
Bad connection
4 Contact the professional who takes care of
maintenance of the appliance
B22 BL.FLAME LOS
No flame during operation No ionization current
4 Check that the gas valve is fully opened
4 Contact the professional who takes care of
maintenance of the appliance
B25
BL.SU ERROR
Internal error on the SU PCB
4 Contact the professional who takes care of
maintenance of the appliance
B26 BL.DHW. S.
The DHW tank sensor is disconnected or short circuited
4 Contact the professional who takes care of
maintenance of the appliance
6. Troubleshooting MCA 35
33
15/06/12 - 300022163-001-01
Page 35
Code Messages Description Checking / solution
B27 BL.DHW INST
The sensor on the plate exchanger outlet is disconnected or short circuited
4 Contact the professional who takes care of
maintenance of the appliance
M04 REVISION
A service is required The date programmed for the service has been reached
4 If the symbol ? flashes, press key ?. The installer's
contact details are displayed.
4 Contact the professional who takes care of
maintenance of the appliance
M05 REVISION A
An A, B or C service is required The date programmed for the service has been reached
4 If the symbol ? flashes, press key ?. The installer's
contact details are displayed.
4 Contact the professional who takes care of
maintenance of the appliance
M06
REVISION B
M07 REVISION C
M20 DISGAS
A boiler vent cycle is underway Switching the boiler on
4 Wait 3 minutes
FL.DRY.B XX DAYS
Floor drying is active XX DAYS = Number of days'
floor drying remaining.
Floor drying is underway. Heating on the circuits not concerned is shut down.
4 Contact the professional who takes care of
maintenance of the appliance
FL.DRY.C XX DAYS
FL.DRY.B+C XX DAYS
M23 CHANGE OUTSI.S
The outside temperature sensor is defective.
Change the outside radio temperature sensor.
M30 BL.COM.MODBUS
No communication with the master regulation by the network MODBUS.
Contact the professional who takes care of maintenance of the appliance.
M31 BL.SYSTEM NETWORK
Incorrect configuration of the network MODBUS.
Contact the professional who takes care of maintenance of the appliance.
STOP N XX
The shutdown is active XX = Number of the active shutdown
A shutdown is underway. The circuits selected for this stop are in Antifreeze mode during the period chosen.
6.3 Faults (Code type Lxx or Dxx)
In the event of operational failure, the control panel flashes and displays an error message and a corresponding code.
1. Make a note of the code displayed. The code is important for the correct and rapid diagnosis of the type of failure and for any technical assistance that may be needed.
2. Press the t key. If the code is displayed again, switch off the boiler and then switch it back on.
bar
1
1
2
2
r
c
STD
(
t
v
0 2 4 6 8 10 12 14 16 18 22 2420
p
b
AUTO
x
c
r
j
M
g
m
SUNDAY 11:45
TEMP. : 68°
PCU. COM. FAIL. D27
C002604-B-04
MCA 35
6. Troubleshooting
15/06/12 - 300022163-001-01
34
Page 36
3. Press the ? key. Follow the instructions displayed to solve the problem.
4. Consult the meaning of the codes in the table below:
Code Faults Cause
of the fault
Description Checking / solution
L00 PSU FAIL
PCU PSU PCB not connected Bad connection
PSU PCB faulty
4 Contact the professional who takes care of
maintenance of the appliance
L01 PSU PARAM FAIL
PCU The safety parameters are incorrect Bad connection
PSU PCB faulty
4 Contact the professional who takes care of
maintenance of the appliance
L02 DEF.OUTLET S.
PCU The boiler flow sensor has short-
circuited
Bad connection Sensor fault
4 Contact the professional who takes care of
maintenance of the appliance
L03 DEF.OUTLET S.
PCU The boiler flow sensor is on an open
circuit
Bad connection Sensor fault
4 Contact the professional who takes care of
maintenance of the appliance
L04 DEF.OUTLET S.
PCU Boiler temp too low Bad connection
Sensor fault
4 Contact the professional who takes care of
maintenance of the appliance
No water circulation
4 Vent the air in the heating system
4 Check the circulation (direction, pump,
valves)
4 Check the water pressure
L05 STB OUTLET
PCU Boiler temperature too high Bad connection
Sensor fault
4 Contact the professional who takes care of
maintenance of the appliance
No water circulation
4 Vent the air in the heating system
4 Check the circulation (direction, pump,
valves)
4 Check the water pressure
L06 BACK S.FAILURE
PCU The return temperature sensor has
short-circuited
Bad connection Sensor fault
4 Contact the professional who takes care of
maintenance of the appliance
bar
1
1
2
2
r
c
STD
(
'
t
v
0 2 4 6 8 10 12 14 16 18 22 2420
p
b
AUTO
x
c
r
j
M
g
m
SUNDAY 11:45
TEMP. : 68°
PCU COM.FAIL D27
C002302-D-04
6. Troubleshooting MCA 35
35
15/06/12 - 300022163-001-01
Page 37
Code Faults Cause
of the fault
Description Checking / solution
L07 BACK S.FAILURE
PCU The return temperature sensor is on
an open circuit
Bad connection Sensor fault
4 Contact the professional who takes care of
maintenance of the appliance
L08 BACK S.FAILURE
PCU Return temperature too low Bad connection
Sensor fault
4 Contact the professional who takes care of
maintenance of the appliance
No water circulation
4 Vent the air in the heating system
4 Check the circulation (direction, pump,
valves)
4 Check the water pressure
L09 STB BACK
PCU Return temperature too high Bad connection
Sensor fault
4 Contact the professional who takes care of
maintenance of the appliance
No water circulation
4 Vent the air in the heating system
4 Check the circulation (direction, pump,
valves)
4 Check the water pressure
L10 DEP-RET>MAX
PCU Difference between the flow and
return temperatures insufficient
Bad connection Sensor fault
4 Contact the professional who takes care of
maintenance of the appliance
No water circulation
4 Vent the air in the heating system
4 Check the circulation (direction, pump,
valves)
4 Check the water pressure
L11 RET-DEP>MAX
PCU Difference between the flow and
return temperatures too great
Bad connection Sensor fault
4 Contact the professional who takes care of
maintenance of the appliance
No water circulation
4 Vent the air in the heating system
4 Check the circulation (direction, pump,
valves)
4 Check the water pressure
L12 STB OPEN
PCU Maximum boiler temperature
exceeded (STB thermostat maximum)
Bad connection Sensor fault
4 Contact the professional who takes care of
maintenance of the appliance
No water circulation
4 Vent the air in the heating system
4 Check the circulation (direction, pump,
valves)
4 Check the water pressure
MCA 35 6. Troubleshooting
15/06/12 - 300022163-001-01
36
Page 38
Code Faults Cause
of the fault
Description Checking / solution
L14 BURNER FAILURE
PCU 5 burner start-up failures No ignition
4 Contact the professional who takes care of
maintenance of the appliance
Ignition arc, but no flame formation
4 Check that the gas valve is fully opened
4 Contact the professional who takes care of
maintenance of the appliance Presence of the flame but insufficient ionization (<3 µA)
4 Check that the gas valve is fully opened
4 Contact the professional who takes care of
maintenance of the appliance
L16
PARASIT FLAME
PCU Detection of a parasite flame Ionization current present when there should not
be a flame Ignition transformer defective Gas valve defective The burner remains very hot: CO2 too high
4 Contact the professional who takes care of
maintenance of the appliance
L17 VALVE FAIL
PCU Problem on the SU PCB Bad connection
SU PCB faulty
4 Contact the professional who takes care of
maintenance of the appliance
L34 FAN FAILURE
PCU The fan is not running at the right
speed
Bad connection Fan defective
4 Contact the professional who takes care of
maintenance of the appliance
L35 BACK>BOIL FAIL
PCU Flow and return reversed Bad connection
Sensor fault
4 Contact the professional who takes care of
maintenance of the appliance Water circulation direction reversed
4 Check the circulation (direction, pump,
valves)
L36 I-CURRENT FAIL
PCU The flame went out more than 5
times in 24 hours while the burner was operating
No ionization current
4 Check that the gas valve is fully opened
4 Contact the professional who takes care of
maintenance of the appliance
L37
SU COM.FAIL
PCU Communication failure with the SU
PCB
Bad connection
4 Contact the professional who takes care of
maintenance of the appliance
L38 PCU COM.FAIL
PCU Communication failure between the
PCU and SCU PCBs
Bad connection SCU PCB not connected or faulty
4 Contact the professional who takes care of
maintenance of the appliance
L39 BL OPEN FAIL
PCU The BL inlet opened for a short time Bad connection
External cause Parameter incorrectly set
4 Contact the professional who takes care of
maintenance of the appliance
6. Troubleshooting MCA 35
37
15/06/12 - 300022163-001-01
Page 39
Code Faults Cause
of the fault
Description Checking / solution
L40 TEST.HRU.FAIL
PCU HRU/URC unit test error Bad connection
External cause Parameter incorrectly set
4 Contact the professional who takes care of
maintenance of the appliance
L250 DEF.WATER MIS.
PCU The water pressure is too low Hydraulic circuit incorrectly vented
Water leak Measurement error
4 Top up with more water if necessary
4 Reset the boiler
L251
MANOMETRE FAIL
PCU Fault on the water pressure sensor Wiring problem
The manometer is defective Sensor pcb defective
4 Contact the professional who takes care of
maintenance of the appliance
D03 D04
OUTL S.B FAIL. OUTL S.C FAIL.
SCU Circuit B flow sensor fault
Circuit C flow sensor fault Remarks:
The circuit pump is running. The 3-way valve motor on the circuit is no longer powered and can be adjusted manually.
Bad connection Sensor fault
4 Contact the professional who takes care of
maintenance of the appliance
D05 OUTSI.S.FAIL.
SCU Outside temperature sensor fault
Remarks: The boiler operates on BOILER MAX temperature. The valve setting is no longer ensured but monitoring the maximum temperature of the circuit after the valve is ensured. Valves may be manually operated. Reheating the domestic hot water remains ensured.
Bad connection Sensor fault
4 Contact the professional who takes care of
maintenance of the appliance
D07 SYST.SENS.FAIL.
SCU System sensor fault Bad connection
Sensor fault
4 Contact the professional who takes care of
maintenance of the appliance
D09 DHW S.FAILURE
SCU Domestic hot water sensor fault
Remarks: Heating of domestic hot water is no longer ensured. The load pump operates. The load temperature of the dhw tank is the same as the boiler.
Bad connection Sensor fault
4 Contact the professional who takes care of
maintenance of the appliance
D11 D12 D13
ROOM S.A FAIL. ROOM S.B FAIL. ROOM S.C FAIL.
SCU A room temperature sensor fault
B room temperature sensor fault C room temperature sensor fault
Note: The circuit concerned operates without any influence from the room sensor.
Bad connection Sensor fault
4 Contact the professional who takes care of
maintenance of the appliance
D14 MC COM.FAIL
SCU Communication failure between the
SCU PCB and the boiler radio module
Bad connection
4 Check the link and the connectors
Boiler module failure
4 Change the boiler module
MCA 35 6. Troubleshooting
15/06/12 - 300022163-001-01
38
Page 40
Code Faults Cause
of the fault
Description Checking / solution
D15 ST.TANK S.FAIL
SCU Storage tank sensor fault
Note: The hot water storage tank reheating operation is no longer assured.
Bad connection Sensor fault
4 Contact the professional who takes care of
maintenance of the appliance
D16 D16
SWIM.P.B. S.FAIL SWIM.P.C. S.FAIL
SCU Swimming pool sensor fault circuit B
Swimming pool sensor fault circuit C Note:
Swimming pool reheating is always done during the circuit's comfort period.
Bad connection Sensor fault
4 Contact the professional who takes care of
maintenance of the appliance
D17 DHW 2 S.FAIL
SCU Sensor fault tank 2 Bad connection
Sensor fault
4 Contact the professional who takes care of
maintenance of the appliance
D27 PCU COM. FAIL
SCU Communication failure between the SCU and PCU PCBs
4 Contact the professional who takes care of maintenance of the appliance
D32 5 RESET:ON/OFF
SCU 5 resets done in less than an hour
4 Switch the boiler off and switch back on
4 If the boiler does not start after several resets (5 attempts possible), contact your
heating engineer and inform him of the error message displayed
D37
TA-S SHORT-CIR
SCU The Titan Active System® is short-circuited
4 Contact the professional who takes care of maintenance of the appliance
Remarks: Domestic hot water production has stopped but can nonetheless be restarted using key r. The tank is no longer protected. If a tank without Titan Active System® is connected to the boiler,check that the TAS simulation connector (delivered with package AD212) is fitted to the sensor card.
D38 TA-S DISCONNEC
SCU The Titan Active System® is on an open circuit
4 Contact the professional who takes care of maintenance of the appliance
Remarks: Domestic hot water production has stopped but can nonetheless be restarted using key r. The tank is no longer protected. If a tank without Titan Active System® is connected to the boiler,check that the TAS simulation connector (delivered with package AD212) is fitted to the sensor card.
D99 DEF.BAD PCU
SCU The SCU software version does not recognise the PCU connected
4 Contact the professional who takes care of maintenance of the appliance
6. Troubleshooting MCA 35
39
15/06/12 - 300022163-001-01
Page 41
7 Technical specifications
7.1 Technical specifications
Boiler type
MCA 35
General
Flow rate setting Adjustable
Modulating, Start/Stop, 0 - 10 V
Nominal output (Pn) Heating System (80/60 °C)
minimum-maximum kW 6,3 - 33,7
Factory setting kW 33,7
Data on the gases and combustion gases
Gas consumption - Natural gas H (G20) minimum-maximum
m3/h
0,69 - 3,71
Gas consumption - Natural gas L (G25) minimum-maximum
m3/h
0,80 - 4,32
Gas consumption - Propane G31 minimum-maximum
m3/h
0,27 - 1,44
NOx-Emission per year (n =1)
mg/kWh
42
Characteristics of the heating circuit
Water content
l 2,3
Water temperature maximum °C 110
Operating temperature maximum °C 90
Electrical characteristics
Power supply voltage
VAC 230
Power consumption - Full load
maximum W 173
Factory setting W 151
Electrical protection index
IPX4D
Other characteristics
Total weight (empty)
kg 39
Acoustic level at 1 metre at full load
dB(A) 45
MCA 35 7. Technical specifications
15/06/12 - 300022163-001-01
40
Page 42
8 Energy savings
8.1 Energy-saving advice
4 Keep the room in which the boiler is installed well ventilated.
4 Do not block ventilation outlets.
4 Do not cover the radiators. Do not hang curtains in front of the
radiators.
4 Install reflective panels behind the radiators to prevent heat
losses.
4 Insulate the pipes in rooms that are not heated (cellars and lofts).
4 Close the radiators in rooms not in use.
4 Do not run hot (or cold) water pointlessly.
4 Install a water-saving shower head to save up to 40 % energy.
4 Take showers rather than baths. A bath consumes twice as much
water and energy.
8.2 Recommendations
The remote control is available in the following versions:
4 Wire
4 Radio
The setting of the control panel and/or of the remote control has a considerable influence on energy consumption.
A few tips:
4 In the room in which the room thermostat is installed, it's advised
not to use thermostatic valve radiators. If a thermostatic valve is used the valve must be fully opened.
4 Completely closing and opening thermostatic valve radiators
causes undesirable temperature fluctuations. Open and close thermostatic valves in small steps.
4 Lower the temperature to around 20°C. This reduces heating costs
and energy consumption.
4 Lower the temperature when you air the rooms.
4 When setting a time schedule , bear days when you are absent
and holidays in mind.
8. Energy savings
MCA 35
41
15/06/12 - 300022163-001-01
Page 43
9 Warranty
9.1 General
You have just purchased one of our appliances and we thank you for the trust you have placed in our products.
Please note that your appliance will provide good service for a longer period of time if it is regularly checked and maintained.
Your fitter and our customer support network are at your disposal at all times.
9.2 Warranty terms
The following provisions are not exclusive of the buyer being able benefit from the legal provisions applicable regarding hidden defects in the buyer's country.
Starting from the purchase date shown on the original fitter's invoice, your appliance has a contractual guarantee against any manufacturing defect.
The length of the guarantee is mentioned in the price catalogue. The manufacturer is not liable for any improper use of the appliance or failure to maintain or install the unit correctly (the user shall take care to ensure that the system is installed by a qualified engineer).
In particular, the manufacturer shall not be held responsible for any damage, loss or injury caused by installations which do not comply with the following:
4 applicable local laws and regulations,
4 specific requirements relating to the installation, such as national
and/or local regulations,
4 the manufacturer's instructions, in particular those relating to the
regular maintenance of the unit,
4 the rules of the profession.
The warranty is limited to the exchange or repair of such parts as have been recognised to be faulty by our technical department and does not cover labour, travel and carriage costs.
The warranty shall not apply to the replacement or repair of parts damaged by normal wear and tear, negligence, repairs by unqualified parties, faulty or insufficient monitoring and maintenance, faulty power supply or the use of unsuitable fuel.
Sub-assemblies such as motors, pumps, electric valves etc. are guaranteed only if they have never been dismantled.
The legislation laid down by european directive 99/44/EEC, transposed by legislative decree No. 24 of 2 February 2002 published in O.J. No. 57 of 8 March 2002, continues to apply.
MCA 35
9. Warranty
15/06/12 - 300022163-001-01
42
Page 44
DUEDI S.r.l.
www.duediclima.it
Distributore Ufficiale Esclusivo
De Dietrich-Thermique Italia
Via Passatore, 12 - 12010 San Defendente di Cervasca CUNEO
+39 0171 857170 +39 0171 687875 info@duediclima.it
IT
DE DIETRICH THERMIQUE Iberia S.L.U.
DE DIETRICH THERMIQUE S.A.S
www.dedietrich-calefaccion.es
Av. Princep d’Astúries 43-45
08012 BARCELONA
+34 932 920 520 +34 932 184 709
ES
AD001NU-AH
129164, Россия, г. Москва
Зубарев переулок, д. 15/1
Бизнес-центр «Чайка Плаза»,
офис 309
+7 (495) 221-31-51
© Copyright All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing.
15/06/12
300022163- 001- 01