DeDietrich Elitec DTG 130 User Manual

Page 1
DTG 130
Low temperature gas boiler
Elitec
User Guide
300004565-001-C
EN
Page 2
DTG 130 20/02/09 - 300004565-001-C
. Contents
Contents
1 Used symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2 Important recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.1 Aeration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2.3 Adapting to another gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3.1 Boilers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3.2 Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
4 Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
5 Stopping the boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
6 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Page 3
20/02/09 - 300004565-001-C DTG 130
2. Important recommendations
Congratulations on your choice of a high quality product. We strongly advise you to read the following instructions in order to guarantee the optimal operation of your appliance. We are sure that it will be entirely to your satisfaction and will meet with all of your expectations.
1 Used symbols
Caution danger Risk of injury and damage to equipment. Attention must be paid to the warnings on safety of persons and equipment.
Specific information Information must be kept in mind to maintain comfort.
Z
Reference Refer to another manual or other pages in this instruction manual.
2 Important recommendations
For a proper operating of the boiler, follow carefully the instructions.
Any intervention on the appliance and heating equipment must be carried out by a qualified technician.
The manufacturer is not liable for any improper use of the appliance or failure to maintain or install the unit correctly (the user shall take care to ensure that the system is installed by a qualified fitter).
Check the seal on the gas and water pipe connections.
Check that the appliance is properly set for the type of gas used.
Keep to the polarity shown on the terminals: phase (L), neutral (N) and earth
4
.
Check regularly that the installation contains water and is pressurised.
Burn hazard in direct contact with the flame inspection window.
To guarantee protection against the corrosion of domestic hot water calorifiers fitted with a titanium anode (Titan Active System ® protection system), always leave the control panel switched on.To switch off the heating or the domestic hot water, use the Summer or Antifreeze mode.
Forced flue versions: Check the air flap setting.
2.1 Aeration
2.1.1 Chimney versions
Do not obstruct the air inlets in the room (even partially).
France: the cross section of the aeration vent, which is compulsory
in the boiler room in which the boiler is installed, must comply with the DTU 61.1 (P 45 204) standard and, in particular, with the instruction on boiler room layout (Book 1764 April 1982).
Belgium:the cross-section of the aeration vents, which are compulsory in the room in which the boiler is installed, must comply with the NBN D51-003 standard.
Germany: the cross section of the ventiliation vents, which are compulsory in the room in which the boiler is installed, must comply with the VDI 2050 form 1 standard and with other prevailing regulations
Other countries: the cross section of the aeration inlet, which is compulsory in the premises in which the boiler is installed, must comply with the standards in force in the country.
2.1.2 Forced flue versions
It is not necessary to provide ventilation of the premises in which the boiler is installed. Ventilation is required if a mechanical connection to the gas exists.
Page 4
DTG 130 20/02/09 - 300004565-001-C
2. Important recommendations
2.2 Maintenance
- The servicing and cleaning of the boiler and the sweeping of the flue gas pipe and the bleed pot must be done at least once a year by a qualified professional.
- We recommend taking out a maintenance contract.
- Regularly check the level of water in the system and top up if required, taking care that cold water is not added suddenly into the boiler when it is hot. If this operation is repeated several times per season, locate the leak and repair it.
Do not drain the installation, except in cases of absolute necessity. For example: Several months' absence with the risk of ice in the building.
2.3 Adapting to another gas
Belgium:
The operations required to switch from one gas to another must be carried out by a SERV'elite technician.
Other countries:
The operations required to switch from one gas to another must be carried out by your fitter.
Page 5
20/02/09 - 300004565-001-C DTG 130
3. Description
3 Description
3.1 Boilers
The models presented are marketed in the various countries according to the countries' specific sales programme.
3.1.1 Chimney versions
DTG 130 Eco.NOx
DTG 1300 Eco.NOx/V
9
5
10
8518N002
4
1 2
3
6
7
8
11
5
10
4
2
3
6
7
8
11
8518N070
1
9
18
19
1
Safety box
2
Gas regulation block
3
Gas inlet
4
Burner
5
Flame inspection window
6
Ignition electrode
7
Ionization probe
8
Ignition burner
9
Ignition burner gas supply pipe
10
Downdraught thermostat
11
Sensor tube
12
Pressure gauge
13
Heating circulation pump
14
Drain cock
15
Safety valve
16
Expansion vessel
17
Automatic air vent
18
Domestic hot water tank
19
Flange for the domestic hot water tank
Page 6
DTG 130 20/02/09 - 300004565-001-C
3. Description
3.2 Control panel
3.2.1 Control panel B
C000142_08
1
4
2 3 5
6
4
5
6
7
81
2
3
3
4
5
6
7
8
9
79 8
4 A M P
1
General ON
8
/ OFF 7 switch
2 Reset button + Alarm indicator
3
Summer
%
/ Winter . switch
4 TEST STB button
5 Safety thermostat with manual reset
6 Timed circuit breaker (4 A)
7 Boiler thermostat
8
Alternate display of the following temperatures:
- Light
"
lit: Water temperature in the boiler
- Light
lit: Domestic hot water temperature
9 domestic hot water thermostat
Page 7
20/02/09 - 300004565-001-C DTG 130
3. Description
3.2.2 Control panel DIEMATIC 3
Electromechanical components
Display
4
A M P
C000142_07
1
02468 10 12 14 16 18 20 22 24
A
7
4
2
3 5
6
SUNDAY
-04
1
General ON
8
/ OFF 7 switch
2 Reset button + Alarm indicator
3
Switch AUTO/
!
4 TEST STB button
5 Safety thermostat with manual reset (110 °C)
6 Timed circuit breaker (4 A)
7 Operating light
02468 10 12 14 16 18 20 22 24
A
bar
3 4 5 6 7
91011
8
2 1
BC
SUNDAY
1 Text and numerical display
2 Graphic display bar for the programme in circuit A, B or C
3
Light area: Reduced temperature heating period or tank load disabled
4
Dark area: Comfort temperature heating period or tank load enabled
5 Flashing cursor showing the current time
6
Number display (current time, adjusted values, parameters, etc.)
7
Active programme display, P1, P2, P3, P4 or
E: Summer mode activated
8
The arrows flash when setting values can be modified using the + and - keys
9 Circuit operation symbols
>
Opening the 3-way valve
=
Closing the 3-way valve
:
Displayed circuit pump on
A, B, C Name of the circuit displayed
10 Symbol displayed above the active operating mode
11
Symbols indicating that the following inputs/outputs are active
D
Burner on
DHW load pump on
#
Summer mode
T
Not available
Page 8
DTG 130 20/02/09 - 300004565-001-C
3. Description
Keys accessible when the flap is closed
Keys accessible when the flap is open
02468 10 12 14 16 18 20 22 24
A
C000142_02
SUNDAY
-04
Temperature setting keys
2%
Comfort temperature
2$
Reduced temperature
2
Domestic hot water temperature
/
Is used to adjust the selected temperature
Operating mode selection keys
AUTO Heating according to the time programme
%
Forced Comfort mode:
- until midnight if  flashes
- all the time if
is steady
$
Forced Low mode:
- until midnight if
flashes
- all the time if
is steady
.
Antifreeze mode
Tank load enabled mode
A
02468 10 12 14 16 18 20 22 24
A
STANDARD
C000142_03
SUNDAY
-04
#
Manual "Summer" shutdown key The heating is switched off and DHW production is ensured. The symbols
#
and E are displayed.
STANDARD
"Standard" programme key Reset of all time programmes.
K
Fitter settings access key
Key for access to setting and measurements
J
Page scrolling
I
Line scrolling
H
Return to the previous line
Programming keys
%O
Enter (per 1/2 hour) the comfort temperature period or tank load enabled (dark area)
$O
Enter (per 1/2 hour) the reduced temperature period or tank load disabled (light area)
S
Return key
A, B, C Circuit display selection key
PROG
Active heating programme selection key (P1, P2, P3 or P4)
Page 9
20/02/09 - 300004565-001-C DTG 130
4. Commissioning
4 Commissioning
Initial commissioning must be done by a qualified professional.
1. Check the water pressure in the installation. Top up with more
water if necessary.
2. Open the gas valve.
3. Check that the safety thermostat has not triggered. Remove the
safety thermostat hood and press the reset button with a screwdriver.
4. Control panel B:
- Set the Summer/Winter swtich to
.
Control panel E/E1/D:
-Set switch
AUTO/
!
to the
AUTO
position.
5. Set the On/Off switch to 8.
6. The safety box carries out its ignition cycle.
5 Stopping the boiler
Set the On/Off switch to 7.
On the Off position 7, the domestic hot water calorifier fitted with a titanium anode is not protected against corrosion.
Precautions to take if there is a danger of frost
Heating circuit:
Use a correctly dosed antifreeze to prevent the heating water freezing. If this cannot be done, drain the system completely. In all cases, consult the fitter.
Domestic hot water circuit:
Drain the domestic water tank and pipes.
Precautions to take in the event of prolonged shutdown (one year or more)
- Close the gas valve
- The boiler and the chimney must be swept carefully.
- Close the door of the boiler to prevent the internal circulation of air.
Page 10
10
DTG 130 20/02/09 - 300004565-001-C
6. Troubleshooting
6 Troubleshooting
Checks to make before calling your fitter:
The burner is not working:
- Shutdown by the safety thermostat due to accidental overheating. Check that the safety thermostat has not triggered. To restart the boiler, reset the safety thermostat. Remove the safety thermostat hood and press the reset button with a screwdriver. Carry out the start-up operations again. Call your fitter.
- Chimney versions: downdraught thermostat cut. In the event of smoke release by the anti-blowback device, the anti-release safety device switches off the burner with the safety box on standby for 15 minutes (this is indicated by an alarm indicator flashing). If these interruptions are repeated, contact your fitter.
The burner is operating but the radiators are cold:
- Bleed the radiators.
- Top up the primary circuit with water.
- Check that the heating pump is operating correctly.
- If it is often necessary to top up the installation with water, contact your fitter.
Before informing the fitter of a fault, make a note of the following information:
- Product type
- Year of manufacture
- Serial number
- Type of gas used
This information can be found on the rating plate stuck to the front plate of the boiler.
Page 11
11
20/02/09 - 300004565-001-C DTG 130
6. Troubleshooting
Warranty
You have just purchased one of our appliances and we thank you for the trust you have placed in our products.
Please note that your appliance will provide good service for a longer period of time if it is regularly checked and maintained.
Your fitter and our customer support network are at your disposal at all times.
Warranty terms
Starting from the purchase date shown on the original fitter's invoice, your appliance has a contractual guarantee against any manufacturing defect.
The length of the guarantee is mentioned in the price catalogue.
The manufacturer is not liable for any improper use of the appliance or failure to maintain or install the unit correctly (the user shall take care to ensure that the system is installed by a qualified fitter).
In particular, the manufacturer shall not be held responsible for any damage, loss or injury caused by installations which do not comply with the following:
- applicable local laws and regulations
- specific requirements relating to the installation, such as national and/or local regulations
- the manufacturer's instructions, in particular those relating to the regular maintenance of the unit
- the rules of the profession
The warranty is limited to the exchange or repair of such parts as have been recognised to be faulty by our technical department and does not cover labour, travel and carriage costs.
The warranty shall not apply to the replacement or repair of parts damaged by normal wear and tear, negligence, repairs by unqualified parties, faulty or insufficient monitoring and maintenance, faulty power supply or the use of unsuitable fuel.
Sub-assemblies such as motors, pumps, electric valves etc. are guaranteed only if they have never been dismantled.
France
The preceding dispositions are not exclusive of benefits for the purchaser of the legal guarantee as stated in Civil Code articles 1641 to 1648.
Belgium
The preceding dispositions about the contractual guarantee are not exclusive of profit if the need arises for the purchaser in Belgium of the applicable legal dispositions on hidden defects.
Switzerland
The application of the warranty is subject to the terms and conditions of sale, delivery and warranty of the company marketing our products.
Poland
Warranty conditions are included in the warranty card.
Other countries
The above provisions do not restrict the benefit of the legal laws regarding hidden defects applicable in the buyer's country.
Page 12
© Copyright
All technical and technological information contained in these technical instructions, as well as any drawings and technical descriptions supplied, remain our property and shall not be multiplied without our prior consent in writing.
Subject to alterations.
20/02/09
DE DIETRICH THERMIQUE 57, rue de la Gare F- 67580 MERTZWILLER - BP 30
DE DIETRICH THERMIQUE S.A.S.
www.dedietrich-thermique.fr
FR
Direction des Vente s France
57, rue de la Gare
F- 67580 MERTZWILLER
+33 (0)3 88 80 27 00 +33 (0)3 88 80 27 99
DE DIETRICH REMEHA GmbH
www.dedietrich-remeha.de
VAN MARCKE
www.vanmarcke.be
WALTER MEIER (Klima Schweiz) AG
www.waltermeier.com
DE
BE
CH
NEUBERG S.A.
www.dedietrich-heating.com
LU
DE DIETRICH
RU
Rheiner Strasse 151
D- 48282 EMSDETTEN
+49 (0)25 72 / 23-5
+49 (0)25 72 / 23-102
info@dedietrich.de
Weggevoerdenlaan 5
B- 8500 KORTRIJK
+32 (0)56/23 75 11
Bahnstrasse 24
CH-8603 SCHWERZENBACH
+41 (0) 44 806 44 24
+41 (0) 44 806 44 25
39 rue Jacques Stas
L- 2010 LUXEMBOURG
+352 (0)2 401 401
ch.klima@waltermeier.com
DE DIETRICH
www.dedietrich-heating.com
CN
Room 512, Tower A, Kelun Building 12A Guanghua Rd, Chaoyang District
C-100020 BEIJING +86 (0)106.581.4017 +86 (0)106.581.4018 +86 (0)106.581.7056 +86 (0)106.581.4019
contactBJ@dedietrich.com.cn
Serviceline +41 (0)8 00 846 846
WALTER MEIER (Climat Suisse) SA
www.waltermeier.com
Z.I. de la Veyre B, St-Légier
CH-1800 VEVEY 1 +41 (0) 21 943 02 22
+41 (0) 21 943 02 33
ch.climat@waltermeier.com
Serviceline +41 (0)8 00 846 846
ÖAG AG
www.oeag.at
AT
Schemmerlstrasse 66-70
A-1110 WIEN
+43 (0)50406 - 61624
+43 (0)50406 - 61569
dedietrich@oeag.at
AD001NU-AB
www.dedietrich-otoplenie.ru
ул. Крутицкий Вал, д. 3
109044 г. Москва
+7 495 988-43-04 +7 495 988-43-04 dedietrich@nnt.ru
корп. 2, оф. 35
Россия
Loading...