DeDietrich HPI G Hybrid, 200 ASL HYBRID 11-16, 200 ASL HYBRID 4–8 User Manual

ADVANCE
S U S T A I N A B L E C O M F O R T
®
MW-8200025-3
HPI G HYBRID
8200025-3
en
User Guide
Hybrid heat pump
HPI G HYBRID
200 ASL HYBRID 4–8
200 ASL HYBRID 11–16
Dear Customer,
Thank you very much for buying this appliance.
Please read through the manual carefully before using the product, and keep it in a safe place for later reference. In order to ensure continued safe and efficient operation we recommend that the product is serviced regularly. Our service and customer service organisation can assist with this.
We hope you enjoy years of problem-free operation with the product.
Contents
1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.3 Specific safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.3.1 Refrigerant fluid R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.4 Liabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1.4.1 Manufacturer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1.4.2 Installer's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1.4.3 User's liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
2 About this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.2 Additional documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.3 Symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.3.1 Symbols used in the manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.3.2 Symbols used on the appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
3 Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.1 Homologations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.1.1 Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
3.2 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
3.2.1 Heat pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.2.2 Domestic hot water tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.2.3 Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.2.4 Combination heaters with medium-temperature heat pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.2.5 Circulating pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
4 Description of the product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4.1 General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
4.2 Operating principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
4.3 Main components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
4.4 Description of the control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4.4.1 Description of the keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4.4.2 Description of the display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
5 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
5.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
5.2 Use of the control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
5.2.1 Browsing in the menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
5.2.2 Accessing the User level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
5.3 Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5.4 Installation shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5.4.1 Switching off the central heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
5.5 Frost Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
6 Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
6.1 List of parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
6.1.1 User Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
6.2 User settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
6.2.1 Setting the Set Point Temperatures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
6.2.2 Selecting the Operating Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
6.2.3 Forcing domestic hot water production . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
6.2.4 Selecting a timer programme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
6.2.5 Customising a timer program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
6.2.6 Calibrating the sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
6.2.7 Setting the contrast and brightness of the display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
6.2.8 Setting the time and date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
7 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
7.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
7.1.1 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
7.2 Standard inspection and maintenance operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
7.3 Cleaning the casing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Contents
7613348 - v06 - 10122018 200 ASL HYBRID 3
8 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
8.1 Error codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
8.1.1 Error messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
8.1.2 Faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
8.2 Error memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
8.2.1 Message History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
8.2.2 Dxx type errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
8.2.3 Bxx type errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
8.3 Fault history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
8.3.1 Lxx type errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
8.4 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
9 Decommissioning and disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
9.1 Decommissioning procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
9.2 Disposal and recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
10 Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
10.1 Energy savings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
11 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
11.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
11.2 Terms of warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
12 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
12.1 Product fiche . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
12.2 Product fiche - Temperature Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
12.3 Package fiche . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Contents
4 200 ASL HYBRID 7613348 - v06 - 10122018
1 Safety
1.1 General safety instructions
Danger
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Danger of electric shock Before any work, switch off all electricity supplies.
Caution Installation of the heat pump must be done by a qualified professional in accordance with prevailing local and national regulations.
Warning Do not touch the refrigeration connection pipes with your bare hands while the heat pump is running. Danger of burn or frost injury.
Warning Do not touch the radiators for long periods. Depending on the heat pump settings, the temperature of the radiators may exceed 60°C.
Warning In order to limit the risk of being scalded, the installation of a thermostatic mixing valve on the domestic hot water flow pipes is obligatory. Take precautions with the domestic hot water. Depending on the heat pump settings, the domestic hot water temperature may exceed 65°C.
Caution Only genuine spare parts may be used.
Warning Only qualified professionals are authorised to work on the domestic water storage tank and the heating system.
1 Safety
7613348 - v06 - 10122018 200 ASL HYBRID 5
Important Insulate the pipes to reduce heat losses to a minimum.
Caution The system must satisfy each point in the rules in force in the country that govern works and interventions in individual homes, blocks of flats or other buildings.
Important Heating water and domestic water must not come into contact with each other.
Important Allow the space required to install the appliance correctly: refer to the chapter Dimensions of the Appliance (Installation and Service Manual).
Caution
Refrigerant safety
Danger In the event of a refrigerant leakage:
1. Switch off the appliance.
2. Open the windows.
3. Do not use a naked flame, do not smoke, do not operate electrical contacts.
4. Avoid contact with the refrigerant. Danger of frost injuries.
5. Evacuate the property.
6. Contact a qualified professional.
Hydraulic safety
1 Safety
6 200 ASL HYBRID 7613348 - v06 - 10122018
Caution The appliance is intended to be permanently connected to the domestic water mains network.
Caution Respect the minimum and maximum water inlet pressure to ensure correct operation of the appliance: refer to the chapter Technical Specifications.
Caution Draining the appliance:
1. Shut off the domestic cold water inlet.
2. Open a hot water tap in the installation.
3. Open a valve on the safety unit.
4. When the water stops flowing, the appliance has been drained.
See For the domestic hot water operating temperature limits: refer to the chapter Technical Data, Domestic Hot Water Tank.
See Setting the domestic hot water temperature set point: refer to the chapter "Setting the domestic hot water temperature set point".
Caution Pressure limiter device: refer to the chapter Special precautions to be taken when connecting the domestic hot water circuit (Installation and Service Manual).
The pressure limiter device (safety valve or safety unit) must be regularly operated in order to remove limescale deposits and ensure that it is not blocked. A pressure limiter device must be fitted to a discharge pipe. As water may flow out of the discharge pipe, the pipe must be kept open to the open air, in a frost-free environment, and at a continuous downward gradient.
Caution A pressure reducer (not provided) is required when the supply pressure exceeds 80% of the safety valve or safety unit calibration and must be located upstream of the appliance.
1 Safety
7613348 - v06 - 10122018 200 ASL HYBRID 7
Caution There must be no cut-off devices between the safety valve or unit and the domestic hot water tank.
Electrical safety
Caution A disconnection device must be fitted to the permanent pipes in accordance with the installation rules.
Caution If a power cord comes with the appliance and it turns out to be damaged, it must be replaced by the manufacturer, its after sales service or persons with similar qualifications in order to obviate any danger.
Caution Install the appliance in accordance with national rules on electrical installation.
Caution If the appliance is not wired in the factory, carry out the wiring according to the wiring schematics described in the chapter Electrical Connections (Installation and Service Manual).
Caution This appliance must be connected to the protective earth. Earthing must comply with prevailing installation standards. Earth the appliance before making any electrical connections. Type and calibre of the protective equipment: refer to the chapter Recommended cable cross­sections (Installation and Service Manual).
Caution To connect the appliance to the mains electricity, refer to the chapter Electrical Connections (Installation and Service Manual).
Caution This appliance must not be powered through an external switch, such as a timer, or be connected to a circuit which is regularly switched on and off by the electricity provider.
1 Safety
8 200 ASL HYBRID 7613348 - v06 - 10122018
Important The Installation Manual for the appliance is also available on our internet site.
1.2 Recommendations
Caution Install the heat pump's indoor module in a frost­free location.
Important Only qualified persons are authorised to assemble, install and maintain the installation.
Caution Maintenance work must be carried out by a qualified professional.
Caution After maintenance or repair work, check the entire heating installation to ensure that there are no leaks.
Caution Only qualified professionals may carry out electrical connections, always with the power off.
Caution Separate the very low voltage cables from the 230/400 V circuit cables.
Important The frost protection function does not work if the heat pump is switched off.
Caution If the home is unoccupied for a long period and there is a risk of frost, drain the indoor module and the heating system.
Important Keep the heat pump accessible at all times.
Important Never remove or cover labels and data plates affixed to the appliances. Labels and data plates must be legible throughout the entire lifetime of the appliance. Damaged or illegible instructions and warning stickers must be replaced immediately.
1 Safety
7613348 - v06 - 10122018 200 ASL HYBRID 9
Important Remove the casing only to perform maintenance and repair work. Put the casing back in place after maintenance and repair work.
Caution Give preference to the or mode rather than
switching off the system to leave the following functions running:
Anti blocking of pumps Frost Protection
Important Regularly check the presence of water and pressure in the heating installation.
Important Keep this document close to the place where the appliance is installed.
Caution Do not make any modifications to the heat pump without the written consent of the manufacturer.
Caution To benefit from extended warranty cover, no modifications must be made to the appliance.
Caution Do not neglect to service the heat pump. Contact a qualified professional or subscribe to a maintenance contract for the annual servicing of the heat pump.
1 Safety
10 200 ASL HYBRID 7613348 - v06 - 10122018
1.3 Specific safety instructions
Warning Refrigerant fluid and pipes:
Use only R410A refrigerant fluid to fill the installation. Use tools and pipe components especially designed for use with
R410A refrigerant fluid. Use copper pipes deoxidised with phosphorus to carry the refrigerant fluid. Store the refrigerant connection pipes away from dust and humidity (risk of damage to the compressor). Do not use a load cylinder. Protect the heat pump components, including the insulation and structural elements. Do not overheat the pipes as brazed components may cause damage. Contact between the refrigerant fluid and a flame may result in emissions of toxic gases.
1.3.1
Refrigerant fluid R410A
Hazard identification Effects harmful to health:
The vapours are heavier than air and may lead to asphyxia owing to reduced oxygen levels. Liquefied gas: contact with the liquid may cause serious frost burn and eye injuries. Product classification: this product is not classified as a "hazardous preparation" according to European Union regulations.
If the R410A refrigerant is mixed with air, it may cause pressure surges in the refrigeration pipes and lead to an explosion and other hazards.
Composition of / Information on the ingredients Chemical nature: R-410A is composed of Difluoromethane R32 and Pentafluoroethane R125
Tab.1 Composition of R-410A fluid
Name
Proportion Number CE Number CAS Difluoromethane R32 50% 200–839–4 75-10-5 Pentafluoroethane
R125
50% 206-557-8 354-33-6
The Global Warming Potential of R410A gas is 2088.
1 Safety
7613348 - v06 - 10122018 200 ASL HYBRID 11
Tab.2 Precautions for use
First aid If inhaled:
Evacuate the subject from the contaminated area and take him into the open air. If feeling unwell: call a doctor.
In the event of contact with the skin:
Treat frost injuries like burns. Rinse with copious amounts of tepid water, do not remove clothing (risk of adhesion to the skin). If skin burns appear, call a doctor immediately.
In the event of contact with the eyes:
Rinse immediately with water, holding the eyelids well apart (for at least 15 minutes). Consult an ophthalmologist immediately.
Fire prevention meas ures
Appropriate extinguishing agents: All extinguishing agents can be used. Inappropriate extinguishing agents: none to our knowledge. In the event of fire nearby, use the appropriate extinguishing agents. Specific hazards:
Rise in pressure: in the presence of air, an inflammable mixture may form under certain temperature and pressure conditions. Toxic and corrosive vapours may be released by the effect of the
heat. Special intervention methods: cool the volumes exposed to heat with water spray. Protection of the firemen:
Full self-contained breathing apparatus.
Complete body protection.
In the event of acci dental spillage
Individual precautions:
Avoid contact with the skin and eyes. Do not intervene without appropriate protective equipment. Do not inhale the vapours. Evacuate the hazardous area. Stop the leakage. Eradicate all sources of ignition. Ventilate the spillage area mechanically.
Cleaning / decontamination: allow any residual product to evaporate. In the event of contact with the eyes: Rinse immediately with water, holding the eyelids well apart (for at least 15 minutes). Consult an oph thalmologist immediately.
Handling Technical measures: ventilation
Precautions to be taken:
No smoking.
Prevent the build-up of electrostatic charges.
Work in a well ventilated place.
1 Safety
12 200 ASL HYBRID 7613348 - v06 - 10122018
Personal protection Respiratory protection:
If ventilation is insufficient: AX type cartridge mask.
In confined spaces: self-contained breathing apparatus. Hand protection: protective gloves in leather or nitrile rubber. Eye protection: safety glasses with side protection. Skin protection: clothing made principally of cotton Industrial hygiene: do not drink, eat or smoke at the place of work.
Considerations on dis posal
Important Disposal must be done in compliance with prevailing lo cal and national regulations.
Product waste: consult the manufacturer or the supplier for informa tion on recovery or recycling. Soiled packaging: reuse or recycle after decontamination. Destroy in authorised installations.
Regulation
Regulation (EU) No. 517/2014 of the European Parliament and of the Council of 16 April 2014 on fluorinated greenhouse gases and re pealing Regulation (EC) No. 842/2006.
1.4
Liabilities
1.4.1
Manufacturer's liability
Our products are manufactured in compliance with the requirements of the various Directives applicable. They are therefore delivered with the marking and any documents necessary. In the interests of the quality of our products, we strive constantly to improve them. We therefore reserve the right to modify the specifications given in this document.
Our liability as manufacturer may not be invoked in the following cases:
Failure to abide by the instructions on installing and maintaining the appliance. Failure to abide by the instructions on using the appliance. Faulty or insufficient maintenance of the appliance.
1.4.2 Installer's liability
The installer is responsible for the installation and initial commissioning of the appliance. The installer must observe the following instructions:
Read and follow the instructions given in the manuals provided with the appliance. Install the appliance in compliance with prevailing legislation and standards.
1 Safety
7613348 - v06 - 10122018 200 ASL HYBRID 13
Carry out initial commissioning and any checks necessary. Explain the installation to the user. If maintenance is necessary, warn the user of the obligation to check the appliance and keep it in good working order. Give all the instruction manuals to the user.
1.4.3 User's liability
To guarantee optimum operation of the system, you must abide by the following instructions:
Read and follow the instructions given in the manuals provided with the appliance. Call on a qualified professional to carry out installation and initial commissioning. Get your installer to explain your installation to you. Have the required inspections and maintenance carried out by a qualified installer. Keep the instruction manuals in good condition close to the appliance.
1 Safety
14 200 ASL HYBRID 7613348 - v06 - 10122018
2 About this manual
2.1 General
This manual is intended for the user of a 200 ASL HYBRIDhybrid system.
2.2
Additional documentation
This manual contains all settings and information on the 200 ASL HYBRID indoor module, as well as some information on the outdoor unit.
For information on the boiler, refer to the instruction manuals provided with the boiler.
For additional information on the outdoor unit, refer to the manual provided with the outdoor unit.
2.3
Symbols used
2.3.1
Symbols used in the manual
This manual uses various danger levels to draw attention to special instructions. We do this to improve user safety, to prevent problems and to guarantee correct operation of the appliance.
Danger Risk of dangerous situations that may result in serious personal injury.
Danger of electric shock Risk of electric shock.
Warning Risk of dangerous situations that may result in minor personal injury.
Caution Risk of material damage.
Important Please note: important information.
See Reference to other manuals or pages in this manual.
2.3.2 Symbols used on the appliance
1 Alternating current. 2 Protective earthing. 3 Caution: danger of electric shock, live parts. Disconnect the mains
power prior to carrying out any work.
Fig.1 Symbols used on the appliance
1 2
MW-6000066-1
1
2
3
2 About this manual
7613348 - v06 - 10122018 200 ASL HYBRID 15
1 Information on the heat pump: Type of refrigerant fluid, maximum
operating pressure, maximum output absorbed by the indoor module.
2 Information on the domestic hot water tank: Volume, maximum
operating pressure and standby losses of the domestic hot water tank.
3 Before installing and commissioning the appliance, carefully read
the instruction manuals provided.
4 Dispose of used products through an appropriate recovery and
recycling structure.
1 Sensor cable - low voltage 2 Power cord 230 V 3 Heating circuit flow 4 Circuit B flow 5 Heating circuit return 6 Circuit B return (optional) 7 Connection for recirculation 8 Domestic hot water outlet
9 Return from the indoor module to the boiler 10 Flow from the boiler to the indoor module 11 Domestic cold water inlet 12 Drain valve 13 Safety valve 14
3
/8" refrigerant fluid connection - liquid line
15
5
/8" refrigerant fluid connection - gas line
Fig.2 Symbols used on the data plate
1
2
4
3
MW-6000340-1
Fig.3 Symbols used on the connection
label
G3/4"
A
G1"
A
G1"

B
G1"
B
G1"
G3/4"
G3/4"
5/8 69-82 Nm
3/8 34-42 Nm
Ø13
1
2
4
6
8
10
12
3
5
7
9
11
13
MW-6000285-1
14
15
2 About this manual
16 200 ASL HYBRID 7613348 - v06 - 10122018
3 Technical specifications
3.1 Homologations
3.1.1 Directives
This product complies with the requirements of the following European Directives and Standards:
Pressure Equipment Directive 2014/68/EU
Low Voltage Directive 2014/35/EU Generic standard: EN 60335-1 Relevant standard: EN 60335-2-40
Electromagnetic Compatibility Directive 2014/30/EU Generic standards: EN 61000-6-3, EN 61000-6-1 Relevant Standard: EN 55014
This product conforms to the requirements of European Directive 2009/125/EC on the ecodesign of energy-related products.
In addition to the legal requirements and guidelines, the supplementary guidelines in this manual must also be followed.
Supplements or subsequent regulations and guidelines that are valid at the time of installation shall apply to all regulations and guidelines specified in this manual.
3.2 Technical data
3.2.1 Heat pump
Maximum operating pressure: 0.3 MPa (3 bar)
Tab.3 Conditions of use
AWHP 4.5 MR AWHP 6 MR-3 AWHP 8 MR-2 AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2 AWHP 16 TR-2
Limit water op erating temper atures in heat ing mode
+18 °C/+55 °C +18 °C/+60 °C +18 °C/+60 °C +18 °C/+60 °C +18 °C/+60 °C
Outdoor air op erating temper ature limits in heating mode
-15° C/+35 °C -15° C/+35 °C -20° C/+35 °C -20° C/+35 °C -20° C/+35 °C
Water operat ing temperature limits in cooling mode
+7°C / +25°C +7°C / +25°C +7°C / +25°C +7°C / +25°C +7°C / +25°C
Outdoor air op erating temper ature limits in cooling mode
+7 °C/ +46 °C +7 °C/ +46 °C +7 °C/ +46 °C +7 °C/ +46 °C +7 °C/ +46 °C
Tab.4 Heating mode: outside air temperature +7 °C, water temperature at the outlet +35 °C. Performances in accordance
with EN 14511-2.
Measure ment type
Unit AWHP 4.5 MRAWHP 6
MR-3
AWHP 8
MR-2
AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2
AWHP 16 TR-2
Heat output kW 4.6 5.82 7.9 11.39 11.39 14.65 14.65
Coefficient of Perform ance (COP)
5.11 4.22 4.34 4.65 4.65 4.22 4.22
3 Technical specifications
7613348 - v06 - 10122018 200 ASL HYBRID 17
Measure ment type
Unit AWHP 4.5 MRAWHP 6
MR-3
AWHP 8
MR-2
AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2
AWHP 16 TR-2
Absorbed electrical power
kWe 0.90 1.38 1.82 2.45 2.45 3.47 3.47
Nominal wa ter flow rate (ΔT = 5 K)
m3/hour
0.80 1.00 1.36 1.96 1.96 2.53 2.53
Tab.5 Heating mode: outside air temperature +2 °C, water temperature at the outlet +35 °C. Performances in accordance
with EN 14511-2.
Measure ment type
Unit AWHP 4.5 MRAWHP 6
MR-3
AWHP 8 MR-2
AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2
AWHP 16 TR-2
Heat output kW 3.74 3.74 6.80 10.19 10.19 12.90 12.90
Coefficient of Perform ance (COP)
3.97 3.37 3.30 3.19 3.19 3.27 3.27
Absorbed electrical power
kWe 0.88 1.11 2.06 3.19 3.19 3.94 3.94
Tab.6 Cooling mode: outside air temperature +35 °C, water temperature at the outlet +18 °C. Performances in accordance
with EN 14511-2.
Measure ment type
Unit AWHP 4.5 MRAWHP 6
MR-3
AWHP 8 MR-2
AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2
AWHP 16 TR-2
Cooling out put
kW 3.80 4.69 7.90 11.16 11.16 14.46 14.46
Energy effi ciency ratio (EER)
4.28 4.09 3.99 4.75 4.75 3.96 3.96
Absorbed electrical power
kWe 0.89 1.15 2.00 2.35 2.35 3.65 3.65
Tab.7 Common specifications
Measure ment type
Unit AWHP 4.5 MRAWHP 6
MR-3
AWHP 8
MR-2
AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2
AWHP 16 TR-2
Total dy namic head at nominal flow rate
kPa 65 63 44 25 25
Nominal air flow rate
m3/h
2650 2700 3300 6000 6000 6000 6000
Power volt age of the outdoor unit
V 230 230 230 230 400 230 400
Start-up amperage
A 5 5 5 5 3 6 3
Maximal amperage
A 12 13 17 29.5 13 29.5 13
Acoustic power - In side
(1)
dB(A) 49 49 49 48 48 48 48
Acoustic power ­Outside
(2)
dB(A) 61 65 67 69 69 70 70
Refrigerant fluid R410A
kg 1.3 1.4 3.2 4.6 4.6 4.6 4.6
3 Technical specifications
18 200 ASL HYBRID 7613348 - v06 - 10122018
Measure ment type
Unit AWHP 4.5 MRAWHP 6
MR-3
AWHP 8
MR-2
AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2
AWHP 16 TR-2
R410A re frigerant
(3)
tCO2e 2.714 2.923 6.680 9.603 9.603 9.603 9.603
Refrigerant connection (Liquid ­Gas)
inch 1/4 - 1/2 1/4 - 1/2 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8 3/8 - 5/8
Max. pre­charged length
m 7 10 10 10 10 10 10
(1) Noise radiated by the envelope - Test run in accordance with the NF EN 12102 standard, temperature conditions: air 7°C, water 55°C (2) Noise radiated by the envelope - Test run in accordance with the NF EN 12102 standard, temperature conditions: air 7 °C, water 45 °C
for AWHP 4.5 MR only (inner and outer sides).
(3) Quantity of refrigerant calculated in tonnes of CO2 equivalent
Important The values in tonnes of CO2 equivalent are calculated using the
following formula: quantity (in kg) of refrigerant fluid x GWP /
1000. The Global-Warming Potential (GWP) of R410A gas is 2088.
3.2.2 Domestic hot water tank
Tab.8 Technical specifications primary circuit (heating water)
Specification Unit Value
Maximum operating temperature Version with hydraulic back-up
°C 90
Minimum operating temperature °C 7
Maximum operating pressure MPa (bar) 0.3 (3.0)
Exchanger capacity Litres 11.3
Exchange surface 1.7
Tab.9 Technical specifications secondary circuit (domestic water)
Specification Unit Value
Maximum operating temperature °C 80
Minimum operating temperature °C 10
Maximum operating pressure MPa (bar) 1.0 (10.0)
Water capacity Litres 177
Tab.10 Common specifications (in accordance with the PR-EN 13203–5 standard)
AWHP 4.5 MR AWHP 6 MR-3 AWHP 8 MR-2 AWHP 11 MR-2 ,
AWHP 11 TR-2
AWHP 16 MR-2 , AWHP 16 TR-2
Loading time
(1)
1 hour 21 minutes 1 hour 21 minutes 1 hour 21 minutes 1 hour 33 minutes 1 hour 11 minutes
Coefficient of performance domestic hot water (COP
DHW
)
0.75 0.75 0.75 1.07 1.07
(1) Water temperature set point: 57 °C – Outdoor temperature: 7°C – Inside air temperature: 20°C
3 Technical specifications
7613348 - v06 - 10122018 200 ASL HYBRID 19
3.2.3 Weight
Tab.11 Indoor module
Indoor module Unit 200 ASL HYBRID 4–8 200 ASL HYBRID 11–16
Weight empty kg 129 131
Total weight with water kg 324 326
Refer to the boiler manual to calculate the total weight of the indoor module combined with the boiler.
Tab.12 Outdoor unit
Outdoor unit
Unit AWHP 4.5 MRAWHP 6
MR-3
AWHP 8
MR-2
AWHP 11 MR-2
AWHP 11 TR-2
AWHP 16 MR-2
AWHP 16 TR-2
Weight empty
kg 54 42 75 118 130 118 130
3.2.4 Combination heaters with medium-temperature heat pump
Tab.13 Technical parameters for heat pump combination heaters (parameters declared for medium-temperature application)
Product name 200 ASL Hybrid
4.5MR + AGC 15
200 ASL Hybrid 6MR-3 + AGC 25
Air-to-water heat pump Yes Yes
Water-to-water heat pump No No
Brine-to-water heat pump No No
Low-temperature heat pump No No
Equipped with a supplementary heater Yes Yes
Heat pump combination heater Yes Yes
Rated heat output under average conditions
(1)
Prated
kW 8 8
Rated heat output under colder conditions
(1)
Prated
kW 6 6
Rated heat output under warmer conditions
(1)
Prated
kW 4 5
Declared capacity for heating for part load at an indoor temperature of 20 °C and outdoor temperature
T
j
T
j
= -7°C
Pdh
kW 3.8 3.5
T
j
= +2 °C
Pdh
kW 4.3 4.5
T
j
= +7 °C
Pdh
kW 4.5 4.8
T
j
= +12 °C
Pdh
kW 5.5 5.2
T
j
= bivalent temperature
Pdh
kW 4.3 4.5
T
j
= operation limit temperature
Pdh
kW 3.9 3.6
Bivalent temperature
T
biv
°C 2 2
Degradation co-efficient
(2)
Cdh
1.0 1.0
Seasonal space heating energy efficiency under average conditions
ƞ
s
% 135 132
Seasonal space heating energy efficiency under colder conditions
ƞ
s
% 122 121
Seasonal space heating energy efficiency under warmer conditions
ƞ
s
% 172 166
Declared coefficient of performance or primary energy ra tio for part load at an indoor temperature of 20 °C and outdoor temperature
T
j
3 Technical specifications
20 200 ASL HYBRID 7613348 - v06 - 10122018
Loading...
+ 44 hidden pages