DCS BFG-30BGD-L-70845A, BFG-30G-N-70849, BFG-30G-L-70849, BFG-30BS-N-70847, BFG-30BS-L-70847 Owner’s Manual

...
A MESSAGE TO OUR CUSTOMERS
Thank you for selecting this DCS Professional "Liberty Collection" Outdoor Appliance. Because of this appliance's unique features we have developed this Use & Care and Installation Guide. It contains valuable information on how to properly install, operate and maintain your new appliance for years of safe and enjoyable use.
To help serve you better, please fill out and submit your Product Registration by visiting our website at www.dcsappliances.com and selecting "Customer Care" on the home page and then select "Product
Registration". In addition, keep this guide handy, as it will help answer questions that may arise as you use your new appliance.
1-888-936-7872, or emaih customer.care@fisherpaykel.com.
NOTE: Please write the Model, Code and Serial Numbers on this page for references (can be found on the inside, right side panel behind the drip pan handle. See page 7.)
MODEL NUMBER CODE SERIAL NUMBER
NOTE: Inspect the product to verify that there is no shipping damage. If any damage is detected, call the shipper and initiate a damage claim. DCS by Fisher & Paykel is not responsible for shipping damage.
DO NOT discard any packing material (box, pallet, straps) until the unit has been inspected.
WARNING!
Do not try lighting this appliance without reading the "Lighting Instructions" section of this manual. Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before use,
installing or servicing this equipment.This outdoor cooking gas appliance is not intended to be
installed in or on recreational vehicles, boats or in a non-ventilated room. For outdoor residence use
only.
WARNING
1. Do Not store or use gasoline or any other flammable vapors and liquids in the vicinity of
this or any other appliance.
2. An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flames.
3. Remove any covers in place over burners/griddle.
4. If odor continues, keep away from the appliance and immediately call your gas supplier
or your fire department.
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE.
CONTENTS
SAFETY PRACTICES & PRECAUTIONS OUTDOOR APPLIANCE MODELS
BEFORE USING YOUR APPLIANCE INSTALLATION
Locating Outdoor Appliance/Built-in Clearances 8-9 Built-in Construction Details 10
Cart Assembly Instructions 11-15 Gas Hook-up 16-19
Leak Testing 20-21 Burner Adjustment 22 Radiant Assembly 23
Sink 24 Side Shelf (optional) 25-26
Installer Checklist 26
USING THE GRILL
Lighting Instructions 27 Use of the Grill 27-28
USING THE SIDE BURNER
Lighting Instructions
3-5 6
7
29
USING THE GRIDDLE
Thermocouple Before Using the Griddle for the
First Time or to Re-season
Use of the Griddle Lighting Instructions
USING THE SINK
CARE & MAINTENANCE
TROUBLESHOOTING
Outdoor appliance
Side Burner SERVICE WARRANTY
3O
30 30
31
32
33-36
37 38
39 40-41
SAFETY PRACTICES & PRECAUTIONS
IMPORTANT SAFETY NOTICE!
Certain Liquid Propane dealers may fill liquid propane cylinders for use inthe outdoor appliance beyond cylinder filling capacity. This"Overfilling" may create a dangerous condition.
IMPORTANT SAFETY NOTICE!
Be sure to remove covers from grill, griddle or side burners before attempting to light or use.
"Overfilled"tanks can build up excess pressure. As a safety device, the tanks pressure relief valve will vent propane gas vapor to relieve this excess pressure. This vapor is combustible and therefore can be ignited. To reduce this danger, you should take the following safety precautions:
1.
When you have your tank filled, be sure you tell the supplier to fill it to no more than 3/4 (75%) of its total
capacity.
2.
If you own or use a spare tank, or have a disconnected tank, you should NEVER store it near or under the outdoor appliance/cart unit or heat box, or near any other ignition or heat source. A metallic sticker with this warning is provided with the grill to remind you, your family and all others who may use your grill of these safety precautions. Install this sticker close to your barbeque grill.
3. Do not store a full tank in direct sunlight.
WARNING!
Do not try lighting this appliance without reading the "LIGHTING INSTRUCTIONS" section of this manual. This outdoor appliance is for outdoor use only.
WARNING!
Push and hold the igniter button, turn the selected burner knob to "HI" or "SEAR". If burner does not light in 4 to S seconds turn knob"OFF"and wait Sminutes for any accumulated gas to dissipate before trying again.
Begin by insuring proper installation and servicing. Follow the installation instructions within this manual. Have your outdoor appliance installed by a qualified technician. Have the installer show you where the gas supply shut-off valve is located so that you know where to shut off the gas to the outdoor appliance. If you smell gas, your installer has not done a proper job of checking for leaks. If the connections are not perfectly sealed, you can have a small leak and therefore a faint gas smell. Finding a leak is not a"do-it-yourself" procedure. Some leaks can only be found with the burner control in the "ON" position and this must be done by a qualified technician.
STICKER
Children should not be left alone or unattended in an area where the outdoor appliance is being used. Never
allow them to sit, stand or play on or around the outdoor appliance at any time. When in use, portions of the outdoor appliance can get hot enough to cause severe burns.
Do not store items of interest to children around or below the outdoor appliance, in the cart or masonry enclosure. Never allow children to crawl inside a cart or enclosure.
SAFETY PRACTICES & PRECAUTIONS
Never let clothing, pot holders or other flammable materials come in contact with or too close to any grate, burner or hot surface until it has cooled. Fabric may ignite and result in personal injury.
Never attach or disconnect an LP cylinder, or move or alter gas fittings when the grill is in operation or is hot.
Clean and perform general maintenance on the grill twice a year. Watch for corrosion, cracks, or insect activity. Check the regulator, hoses, burner ports, air shutter, and venturi/valve section carefully. Always turn off gas at the source (tank or supply line) prior to inspecting parts.
After a period of storage or non-use (such as over the winter), the gas grill should be checked for gas leaks, deterioration, proper assembly, and burner obstructions before using.
Do not heat unopened food containers as a build-up of pressure may cause the container to burst.
Always use a covered hand when taking off the lid and only do so slowly to allow heat and steam to escape.
Never lean over an open outdoor appliance. When lighting a burner, always pay close attention to what you are doing.
After lighting burners, make sure burners are operating normally (see pages 21 and 22).
When using the outdoor appliance, do not touch the outdoor appliance burner grate or immediate surrounding area as these areas become extremely hot and could cause burns.
Grease is flammable. Let hot grease cool before attempting to handle it. Avoid letting grease deposits collect in the drip pan. Clean often.
For personal safety, wear proper apparel. Loose fitting garments or sleeves should never be worn while using this appliance. Some synthetic fabrics are highly flammable and should not be worn while cooking. Only certain types of glass, heat-proof glass ceramic, earthenware, or other glazed utensils are suitable for outdoor appliance use. Use of some types of materials may break with sudden temperature changes. Use only on low or medium heat settings according to the manufacturer's directions.
WARNING!
Spiders and insects can nest in the burners of this and any other outdoor appliance, and cause the gas to flow from the front of the burner. The gas will flow from the front of the burner into the control panel. This is a very dangerous condition which can cause a fire to occur behind the valve panel, thereby damaging the outdoor appliance components and making it unsafe to operate.
WARNING!
Keep the area surrounding the outdoor appliance free from combustible materials, trash, or combustible fluids and vapors such as gasoline or charcoal lighter fluid. Do not obstruct the flow of combustion and ventilation air.
WARNING!
Never use the outdoor appliance in windy conditions. If located in a consistently windy area (oceanfront, mountaintop, etc.) a wind break will be required. Always adhere to the specified clearances listed.
OUTDOOR APPLIANCE PLACEMENT
PREFERREDAIR FLOW
_ _ FLAME
0000000
`4_*,__*,i/_,_,4,_!_0 ,",0)F-"_ BURNER
@
SAFETY PRACTICES & PRECAUTIONS
Do not use aluminum foil to line drip pans, grates or radiants. This can severely upset combustion air flow or trap excessive heat in the control area. The result of this can be melted knobs or damaged ignition components.
When using the side burners always use flat bottomed pans which are large enough to cover the side burner. Adjust
the flame so that it heats only the bottom of the pan to avoid ignition of clothing. Position handles inward away from open edges of the unit to avoid burns associated with unintentionalspillovers. Hold the handle of the pan to prevent movement of it when turning or stirring food. For proper lighting and performance of the burners, keep the ports clean. It is necessary to clean them periodically for optimum performance.
Clean the outdoor appliance with caution. Avoid steam burns; do not use a wet sponge or cloth to clean the outdoor
appliance while it is hot. Some cleaners produce noxious fumes or can ignite if applied to a hot surface. Be sure all outdoor appliance controls are turned off and the outdoor appliance is cool before using any type of
aerosol cleaner on or around the outdoor appliance. The chemical that produces the spraying action could, in the presence of heat, ignite or cause metal parts to corrode.
Do not use the grill for cooking excessively fatty meats or products which promote flare-ups. Never use outdoor appliance without the drip pan and grease tray in place and pushed all the way to the back.
Without the grease pan, hot grease could leak downward and produce a fire or explosion hazard. Do not operate the outdoor appliance under unprotected combustible construction. Use only in well ventilated areas.
Do not use in buildings, garages, sheds, breezeway, covered structure or other such over head structures and enclosed areas. This unit is for outdoor use only.
If a cart unit is stored indoors, ensure that it is cool, fold the optional side shelf(s) down, and never push or pull on the side shelves. IfLP, the LP cylinder must be unhooked and stored outside in a well ventilated area, out of reach of
children.
Do not use charcoal or lighter fluid in the outdoor appliance.
Never use the outdoor appliance in a windy area.
Never use a dented or rusty LP tank. Keep the ventilation openings of the cylinder enclosure free and clear from debris.
Use only dry potholders; moist or damp potholders on hot surfaces may cause burns from steam. Do not useatowel or bulky cloth in place ofpotholders. Do not let potholderstouch hot portions of the outdoor appliance.
Have an ABC rated Fire Extinguisher accessible - never attempt to extinguish a grease fire with water or ot her liquids.
To avoid burns when cooking, use long handled BBQ tools.
Do not move the appliance during its use.
This unit is for outdoor use only! Do not operate in enclosed areas. This could result in carbon monoxide build-up which would result in injury or death.
When using the grill, be sure that all parts of the unit are firmly in place and that the grill is stable (can't be tipped over).
To put out flare-ups, adjust the controls to lower the temperature CALIFORNIA PROPOSITION 6S-WARNING: The burning of gas cooking fuel generates some by-products which are on
the list of substances which are known by the State of California to cause cancer or reproductive harm. California law requires businesses to warn customers of potential exposure to such substances. To minimize exposure to these
substances, always operate this unit according to the Use and Care Guide, ensuring you provide good ventilation when cooking with gas.
This outdoor cooking gas appliance is not intended to be installed in or on recreational vehicles, trailers and/or boats.
Note:
This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.
OUTDOOR APPLIANCE MODELS
BFG-30G - All-Grill
BFG-30BGD - Double Side Burner/Griddle
BFG-30BS - Double Side Burner/Sink
BEFORE USING YOUR APPLIANCE
1.
Remove all packaging materials and labels from your appliance. If the installer has not set up your appliance, check that you have the following items:
BFG-30G - All-Grill
- All-Grill cover
- Grill grates (5 pcs)
- Radiant trays to hold ceramic rods (2 pcs)
- Ceramic rods (28 pcs)
- Cover hanger (2 pcs)
BFG-3OBGD - Side BurnerlGriddle
- Covers (2 pcs)
- Griddle grease cup
- Side burner grate
- Griddle flu cover
- Cover hanger (2 pcs)
BFG-3OBS - Side BurnerlSink
- Covers (2 pcs)
- Faucet
- Drain plug
- Side burner grate
- Cover hanger (2 pcs)
- Burner caps (2 pcs)
NOTE:
If any of the listed items are missing, contact DCS at (888) 936-7872. Please be prepared with your Model #, Serial # and description of product you have purchased.
Tag location of
Model # and Serial #
Read all installation instructions in this manual to see if the unit has been properly installed. If not done or done correctly, correct before using the unit.
INSTALLATION
LOCATING OUTDOOR APPLIANCE/BUILT-IN CLEARANCES
LOCATION:
When determining a suitable location, take into account concerns such as exposure to wind (If located in a windy area, a wind break must be provided to prevent poor burner performance or product damage.), proximity to traffic paths and keeping any gas or electrical supply lines as short as possible. Locate the outdoor appliance only in a well ventilated area. Do not install the outdoor appliance under overhead unprotected combustible
construction. Never locate the outdoor appliance ina building, garage, breezeway, shed, gazebo, lanai or other such enclosed areas without an approved ventilation system. During heavy use, the outdoor appliance will
produce a lot of smoke and flames. Ensure there is adequate area for it to dissipate.
Important!
Gas fittings, regulator, and installer supplied shut-off valves must be used and easily accessible.
Clearances to Combustible* Construction (see definition on page 9):
A minimum of12" from the sides and a minimum of 12" from the back must be maintained from the outdoor appliance above the cooking surface to adjacent vertical combustible* construction. (Fig. 01) Do not install
under unprotected combustible* construction.
--I Maintain .............. -- Maintain
12" from 12" from combustible :ombustible construction :onstruction
Maintain
12"from
i
2,-:..........2s2, , 3,t
Fig. 01
Important!
All outdoor appliances must have an insulated jacket to combustible island construction.
Clearances to Noncombustible** Construction (see definition on page 9):
A minimum of 3" clearance from the back of the outdoor appliance to noncombustible** construction is required. It is desirable to allow at least 6" side clearance to noncombustible** construction above the cooking surface or counter space. The outdoor appliance can be placed directly adjacent to noncombustible** construction below the cooking surface.
WARNING!
Failure to maintain required clearances creates a fire hazard that may result in property damage or serious personal injury.
WARNING!
If a Noncombustible** material such as metal is covering a combustible material such as wood, the minimum clear- ance distance needs to be held to the wood. The presence of a Noncombustible** material inside the clearance zone
does not eliminate the minimum clearance zone to combustible material.
INSTALLATION
LOCATING BUILT-IN CLEARANCES
WARNING!
The appliances are designed to function in an open area. Recommended minimum clearances should be maintained to all surfaces (combustible _ and noncombustible _*) for optimum performance. Noncombustible _* material within
the minimum clearance area could result in discoloration or deterioration.
*DEFINITION OF COMBUSTIBLE MATERIAL - Any materials of a building structure or decorative structure made of wood, compressed
paper, plant fibers, stucco or other materials that are capable of transferring heat or being ignited and burned. Such material shall be
considered combustible even though flame-proofed, fire-retardant treated, or painted surface or plastered.
**DEFINITION OF Noncombustible MATERIAL - Material which is not capable of being ignited and burned, such as materials consisting entirely of, or a combination of, steel, iron, brick, tile, concrete, slate, and plaster (which is unpainted).
Important!
It is recommended that a minimum of 10 sq. inches of ventilation opening be provided for both the left and right sides, as well as the back of enclosure (Fig. 02), in order to safely dissipate unburned gas vapors in the event of a gas supply leak.
WARNING!
Note specific built-in enclosure ventilation requirements. See text and Fig. 02.
GENERAL
The outdoor appliance is designed for easy placement into masonry enclosures. For non-combustible applications the outdoor appliance drops into the opening shown in Fig. 03 and hangs from its side flanges. The deck must be level and flat. A deck is not required to support the unit from the bottom. When using the insulated jacket in a combustible enclosure application, see the bottom of Fig. 03. The jacket assembly must be supported from the bottom by a ledge on each side or a solid deck beneath the entire insulated jacket.
INSULATED JACKET:
If the outdoor appliance is to be placed into a combustible enclosure, an approved insulated jacket is required and is available from your dealer. Insulated jacket is not required for BFG-30BS Side Burner Sink Model. Use only the DCS insulated jacket (p/n #70859) which has specifically been designed and tested for this purpose.
Review the detail drawing shown (Fig. 03) and take into account the provisions shown for gas line hook-up clearance in the right rear corner. It is recommended that ventilation holes are provided in the enclosure to eliminate the potential build-up of gas in the event of a gas leak. The supporting ledges or deck must be level
and flat. The counter should also be level.
Ventilation Requirements:
2
10 in. Min. ventilation
on the back side
CUTOUTDIMENSIONSOFMATCHINGACCESSDOORS/DRAWERS:
ADN 20X24 ADN 20X30 28" 20"
ADN 20X36 34" 20"
2
10 in. Min.ventilation 2
left hand side on the right hand side
1" Min. Note: not drawn to scale
Opening for access doors/drawers
-10 in. Min. ventilation
Fig. 02
ADN 20X48 46" 20" ADR24 22" 20" ADR36 34" 20" ADR30 28" 20" ADR48 46" 20"
INSTALLATION
BUILT-IN CONSTRUCTION DETAILS
grill
exhaust
2. ZII .........
Standard layout for non-combustible enclosure:
35-1/2" Max.
NOTE: See page 9
for ventilation notes.
-- -- [ 12" (to combustible construction)
J
10-1/16"
J
22-3/4"
for gas supply line
opening for accessdoors (see page gfor ordering information)
i
_ WARNING!
If installing the grill into a non-combustible
enclosure, all combustible construction must still be outside the 12 inch
clearance zone. If your island is made of stucco
over the top of wooden studs, the wood can not be
inside the 12 inch clearance zone to
combustible, even though
the stucco is what is touching the grill area.
Layout for insulated jacket only -corn bustible enclosure:
NOTE: See page 9 for insulated jacket part ordering information.
_" min.
." 3q/2" f_rXg_:°Pupplygine
23-3/4"
_sPeeng:gef°9;cCCe;dd°°gl/r _rc;we rt.Son)
Fig.03
10
INSTALLATION
CART ASSEMBLY INSTRUCTIONS
IMPORTANT:
Read all instructions before you begin. Do not jump ahead or skip any step.
CAUTION:
Some parts have sharp edges; care must be taken when handling the various components to avoid injury. Please read safety information provided in these instructions before beginning
assembly. Wear gloves when handling.
Two or more people should work together to assemble the cart and All-Grill, Double Side
Burner/Sink, or Double Side Burner/Griddle.
NOTE: Avoid using optional side shelf to move cart. Push or pull cart by grasping corners of head.
LOCATING THE CART
For proper use, this product should be installed/positioned on a flat ground or patio. Unevenness such as
bumps, cracks and protrusions should be 1/4" or less. Refer to Fig. 04 for rec uired flat area dimensions.
TOP VIEW (with drawers open)
CAD 30= 30"
Getting Started
Remove packaging.
CAD 36= 36" CAD48 = 48"
Contents Included:
Your cart is packaged in one box.The box contains your 30"cart and a
universal hardware kit to be used for head installation and may contain extra hardware for your convenience.
Contents
i - z _ _//_
. ._ 30" Cart
Machined Phillips
screws 13
10-24X1/2"
Bracket, Tab 2
Bolt Hex
1/4-20-1/2" 2
Qty.
Tools Required:
o ©
Fig.04
Eye Goggles
Work Gloves
Power Screwdriver or
Variable Speed Drill with
Phillips - tip #2 Attachment
5/32"Allen Wrench
(_ Washer 4
.313 x .750
1/4-20
Nut Hex 2
3/16" Allen Wrench
3/32"Allen Wrench
11
INSTALLATION
CART ASSEMBLY INSTRUCTIONS
Step 1
Link Carts Together (optional)
(To link two or more CAD carts, the following instructions must be done first, using
the hardware provided, before installing the top modules.)
To link your carts together - hand tighten 2 bolts, 4 washers, and 2 nuts on the front and back sides of the carts
as shown in Fig. 04. Carefully wrench tighten fasteners once carts are aligned with each other.
CAUTION:
Once the carts are linked, they cannot be moved. Moving the carts once linked could damage the carts.
Head of bolt with washer
End of bolt with nut and washer End of bolt with nut and washer
12
Head of bolt with washer
INSTALLATION
CART ASSEMBLY INSTRUCTIONS
Step 2
Outdoor Appliance Head Preparation
1.
First you will need to remove the angle brackets from the side
of the unit and replace them with cart mount brackets (Fig. 06). Unit is shipped prepared for island installation.
2.
Install the bracket tab on both sides of the appliance head
using 8 of the 10-24 x 1/2" screws. Install each bracket with 4 screws on each side of the outdoor appliance head (Fig. 07 and 08).
Fig.06
Fig. 07
Step 3
Head Placement onto Cart (2 Persons Required)
1.
Remove drip tray/pan (Fig. 09) and other removable components
(to lighten the load) such as grates, top burner caps and components, and griddle flue cover, radiant tray and grill burner for easier handling.
2.
Two persons required to lift head (sink module shown). Placing
head on cart, place rear of head over the rear of the cart first (Fig. 10). Then allow the rear side tabs to first locate in the slots on the top of the cart sides. The other tabs will locate in the middle and front slots as the head is lowered into position on the cart (Fig. 11).
Fig.08
Fig. 09
Fig. 10
Fig. 11
13
INSTALLATION
CART ASSEMBLY INSTRUCTIONS
3.
Position tabs on side bracket to fit into slots on the cart (be aware of pinch points)(Fig. 12-13). When complete, the leading ledge should sit flush on the top of the cart (no gap)(Fig. 14).
Fig. 12 Fig. 13 Fig. 14
4. Secure the head to rear of cart (Fig. 15) with (2) Phillips-head screws provided (10-24 x 1/2").
5. Install remaining (3) screws (10-24 x 1/2") into the front of head to the cart (Fig. 16).
6. Slide drip tray/pan back into place and reinstall parts removed in Step 3, #1.
Fig. 15
Fig. 16
14
INSTALLATION
CART ASSEMBLY INSTRUCTIONS
Step 4
Gas Hookup - LP
Make sure the cart assembly is stable. Open the tank drawer. Place the LP tank into location as shown in Fig. 17. Connect the regulator assembly to the tank connection with all appliances valves in the "OFF" position. Open the tank valve and test for gas leaks (Fig. 18).
Fig. 17 Fig. 18
FORYOUR SAFETY
To prevent personal injury or damage to the drawers, do not overload them. The maximum rating of each drawer is 35 pounds.
WARNING!
Do not push down on the top of the drawers. The unit could tip forward.
COVER HANGER
To use the cover hangers provided, first place the cover hanger into the slot on the side or rear of your Cart (Fig. 19). Then hang
the cover in either direction. (Fig. 20 or 21).
Note:
Do not move the cart while the covers are hung. This could cause
the covers to fall off the hangers and damage the covers.
Fig. 19
Fig. 20
Fig. 21
15
INSTALLATION
GAS HOOK-UP
GAS REQUIREMENT
Verify the type of gas supply to be used, either natural or LID,and make sure the marking on the appliance rating plate agrees with that of the supply. The rating plate is located on the bottom of the outdoor appliance. Never connect an unregulated gas line to the appliance. You must use the gas regulator provided with the unit even if the supply is controlled.
An installer-supplied gas shut-off valve must be installed in an easily accessible location. All installer supplied parts must conform to local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA
70 or the Canadian Electrical Code, CSA C22.1, and the National Fuel Gas Code, ANSI Z223.1 or CAN/CGA-B149.1 Natural Gas Installation Code or CAN/CGA-B149.2 Propane Installation Code.
All pipe sealants must be an approved type and resistant to the actions of LPgases. Never use pipe sealant on flare fittings. All gas connections should be made by a qualified technician and in accordance with local codes and ordinances. In the absence of local codes, the installation must comply with the National Fuel Gas Code, ANSIZ223.1. Gas conversion kits are available from the factory. When ordering gas conversion kits, have the model number, and the type of gas (natural or LP) from your outdoor appliance.
TOTAL GAS CONSUMPTION OF THE OUTDOOR APPLIANCE WITH ALL BURNERS ON
HI/SEAR:
BFG-30G - 50,000 Btu/hr BFG-30BGD - 49,000 Btu/hr BFG-30BS - 34,000 Btu/hr
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 kPa.) The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG (3.5 kPa.). The installation
of this appliance must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1. Installation in Canada must be in accordance with the Standard Canl-b149.1 and/or .2 (installation code for gas burning appliances and equipment) and local codes.
NATURAL GAS HOOK UP: (THIS TYPE OF
CONNECTION SHOULD BE PERFORMED BY A CERTIFIED OR LICENSED TECHNICIAN ONLY.)
Connection: 1/2" NPT male with 3/8" flare adapter. Operating pressure: 4.0" W.C. Supply pressure: 5" to 14" water column. If in excess of 14" W.C., a step- down regulator is required. Check with your local gas utility company or local codes for instructions on installing gas supply lines. Be sure to check on type and size of run, and how deep to bury the line. If the gas line is too small, the outdoor appliance will not function properly. Any joint sealant used must be an approved type and be resistive to the actions of natural gases.
Installer supplied shut-off __
accessible_valvemust be easily _ _ Do not put threading
c t
ottomountJ
Threading compound "_,_ /
must be resistant to LPgas /_ 1/2" NPTx
_ 2.0"
1/2" NPT x 5.0" 4.0" W.C.
Nipple
\Z/_ Adapter 1/2" NPT
__ Regulator
/ to 3/8" flare fitting
coupllng
Nipple
compound on these
TO HOOK-UP THE FITTINGS SUPPLIED WITH THE OUTDOOR APPLIANCE:
Assemble as shown (Fig. 22). Use threading compound on male threads only. Do not use
threading compound on the male end of the 1/2" NPT to 3/8 flare adapter. Useasecond pipe wrench to hold the outdoor appliance inlet pipe to avoid
shifting any internal gas lines of the outdoor appliance. Ensure that the regulator arrow points in
the direction of gas flow towards the unit, away from the supply. Do not forget to place the installer-supplied gas valve in an accessible location.
16
_lnstallation must conform with local
_./' threads
codes or with the National Fuel GasCode ANSIZ223.1 or the CAN/CGA-B149.2
Propane Installation Code
Fig. 22 Natural Gas
INSTALLATION
GAS HOOK-UP
LP GAS HOOK UP (TYPE 1 OR QCC1 REGULATOR):
All outdoor appliances orificed for use with LP gas come equipped with a high capacity hose/regulator assembly for connection to a standard 20 lb. LP cylinder (Type 1). The LP tank is not included.
Connection: 1/2" NPT male with a 3/8" Flare adapter (included). LP Hose with a quick disconnect and fittings are included. Operating pressure: 11.0" W.C.
CAUTION!
Before connecting LP tank to regulator, check that all burners are in the"OFF" position and the lid has been removed.
To connect the LP regulator/hose assembly to the tank/valve assembly, first make sure the main valve on the tank is completely closed. Although the flow of gas is stopped when the Type 1 system is disconnected as part of its safety feature, you should always turn off the LP tank main valve (Fig. 23) after each use and during transport of the tank or unit. Insert the regulator inlet into the tank valve and turn the black coupler clockwise until the coupler tightens up. Do not overtighten the coupler. Turn the main tank valve on, push and turn the burner control valves on the unit to the "HI" position for about 20 seconds to allow the air in the system to purge, turn valves off and wait 5 minutes before attempting to light the burners.
To disconnect the coupler, first make sure the main tank valve is turned off. Grasp the coupler and turn counter clockwise. The inlet will then disengage. Remove the inlet from the tank valve opening if it has not already done so when it disengaged. Your local LP filling station should be equipped with the proper equipment to fill your tank.
LP TANK REQUIREMENTS:
A dented or rusty LP tank may be hazardous and should be checked by your LP supplier. The cylinder that is used must have a collar to protect the cylinder valve. Never use a cylinder with a damaged valve. Always check for leaks after every LP tank change. The LP gas cylinder must be constructed and marked in accordance with the specifications for LP gas cylinders of the U.S. Department of Transportation (DOT or CAN/CSA-B339) and designed for use with a Type 1 system only. Do not change the regulator/hose assembly from that supplied with the unit or attempt to use a Type 1 equipped regulator/hose assembly with a standard 510 POL tank/valve assembly. The cylinder must be provided with a shut-off valve terminating in a LP gas supply cylinder valve outlet specified, as applicable, for connection Type 1. If the appliance is stored indoors, the cylinder must be disconnected and removed from the appliance. Cylinders must be stored outdoors in a well-ventilated area
out of the reach of children.
Note:
When an LP unit is directly attached into an LP house system, the step- down regulator MUST be used to reduce the supply pressure to a max.
14" W.C. and min. 1I" W.C. to the outdoor appliance regulator.
Threading compound must be
resistant to LPgas _ /
Bottom of unit
Type 1 Regulator _ z_ /_ Note: Do not put
_ / f threading compound
Main TankValve _ _ II on male threads of flare
J i ] assembly 11" W.C.
/ l_. _1 (installed on unit)
TypelTank l_ I
k J _lnstallation must conform with
_ local codes or with the National
1/2"female
Fuel Gas Code ANSI Z223.1 orthe CAN/CGA-B149.2 Propane
Installation Code
_._ NPTx 3/8" male flare
_ (installed on unit)
17
Fig. 23 LP Gas
INSTALLATION
GAS HOOK-UP
LP TANK RESTRAINT FOR BUILT-IN INSTALLATION
If the grill is to be installed in a Built-in application, then the grill must be installed in accordance with the Built-in installation guidelines.
If you intend to operate your Built-in grill on LP gas utilizing a 201b Type cylinder, then the Built-in LPtank restraint must be installed prior to initial use of the grill. If you do not have one please contact DCS Customer Care at (888) 936-7872 for information on obtaining one.
The following steps will illustrate how to properly locate and install the LP tank restraint within the Built-in enclosure.
NOTE:
The grill comes with the LP Regulator/Hose assembly installed at the factory. The assembly, along with the entire grill system, is leak tested.
Do not remove the Regulator/Hose assembly from the grill during installation.
The maximum distance from the center of the manifold cut out to the center of the tank restraint is 18 inches.
Tank Restraint can be placed within this area without causing stress on the LP regulator hose
connection.
Center of manifold cut out projected to
floor of the island.
', 18" max.
Fig.24
18
INSTALLATION
GAS HOOK-UP
STEP I
Place the tank restraint in the island (Fig. 25).
STEP 2
Locate the tank restraint in the island within the recommended area (Fig. 24 and 26).
STEP 3 Once located, secure to the bottom of the island using all eight hole
locations provided on the restraint. Wood screws can be used for wooden floors or I/4 inch diameter anchor screws or bolts may be used if the floor is concrete or masonry (Fig. 27).
STEP 4
When secure, place the LP cylinder into the tank restraint making sure to seat the tank all the way down, securely affixing the tank in the restraint (Fig. 28).
STEP 5
Attach the regulator hose assembly and operate the grill normally as described in the Use and Care manual (Fig. 29).
Fig.25
Fig. 26
Fig. 27
Fig.28
Fig.29
19
INSTALLATION
LEAK TESTING - GRILL/GRIDDLE UNIT
GENERAL:
Although all gas connections on the outdoor appliance are leak tested at the factory prior to shipment, a complete gas tightness check must be performed at the installation site due to possible mishandling in shipment, or excessive pressure unknowingly being applied to the unit. Periodically check the whole system for leaks, or immediately check if the smell of gas is detected.
Before Testing:
Do not smoke while leak testing. Extinguish all open flames. Never leak test with an open flame. Makea soap solution of one part liquid detergent and one part water. You will need a spray bottle, brush, or rag to apply the solution to the fittings. For LP units, check with a full cylinder. The valve panel must be removed to check the valves and fittings. Remove the knobs, then remove the 2 screws which fasten the valve panel to the unit (you will need a Phillips screw driver for this). Pull the valve panel outward and unplug the wires from the ignition module.
To Test:
Make sure all control valves are in the "OFF" position. Turn the gas supply "on". Check all connections from the supply line, or LP cylinder up to and including the manifold pipe assembly. Apply the soap solution around the connection, valve, tubing and end of the manifold. Soap bubbles will appear where a leak is present. Ifaleakis present, immediately turn off gas supply, tighten any leaking connections, turn gas on, and recheck. Check all the gas connections at the base of the control valves where they screw into the manifold pipe.
If you cannot stop a gas leak, turn off the gas supply and call your local gas utility, or the dealer you purchased the appliance from. Only those parts recommended by the manufacturer should be used on the outdoor appliance. Substitution can void the warranty.
WARNING!
Do not use the outdoor appliance until all connections have been checked and do not leak.
Check all gas supply fittings for leaks before each use. Keep a spray bottle of soapy water near the gas supply shut-off valve. Spray all the fittings. Bubbles indicate leaks.
Bottom of unlt /
LEAKTEST POINTS _ _ ::: _ %
,:' ",",, [ CHECKCHECKHOSE FOR
.......
L: .......
C
Fig. 30 LP Gas Fig. 31 Nat. Gas
2O
INSTALLATION
LEAK TESTING - SIDE BURNER
WARNING!
Do not smoke while leak testing. Extinguish all open flames.
Make a soap solution of one part liquid detergent, and one part water. Never test for leaks with an open flame. For LP units, check with a full cylinder. Make sure all control valves are in the "OFF" position. Turn the gas supply "ON". Check all connections from the supply line (Fig. 31), or LP cylinder (Fig. 30) up to the manifold pipe assembly (Fig. 32). Apply the soap solution around the connection with a spray bottle, brush, orrag. Soap bubbles will appear where leak is present. If a leak is present, turnoffgas supply, tighten any leaking fittings, turn gas on, and recheck.
WARNING: IMPORTANT! Fig.32
Inspect the gas supply piping or hose prior to turning the gas "ON". If there is evidence of cuts, wear or abrasion, it must be replaced prior to use. Do not use the side burner if the odor of gas is present. Turn the control knob to"OFF", then turn off the gas supply. If using LR is there gas in the tank? Always keep your face and body as far away from the burner as possible when lighting.
Manifold
Gas Control Valve
BURNER ADJUSTMENT - SIDE BURNER
Your new side burner is equipped with burners typical of those used in restaurants (Fig. 33). These burners are designed for maximum cleanability and controlability. The burner should never be operated if the cap is not in place.
BURNER EFFICIENCY AND FLAME CHARACTERISTICS
It is necessary to keep the burner ports and the igniters clean for proper lighting and efficient performance of the burners. The
burner flame should burn completely around the burner with no excessive noise or lifting. The flame should be blue in color and
stable with no yellow tips. During initial use, foreign particles in the gas line, or dust in the air around the appliance may cause an
orange flame. This will disappear with use.
FLAME HEIGHT
The correct height of the flame mainly depends on the size of the bottom of the cooking utensil, the material of the cooking utensil, the amount and type of food and the amount of liquid in the utensil. The following are some basic rules for selecting flame height.
For safety reasons the flame must never extend beyond the bottom of the cooking utensil. Never allow flames to curl up
the side of the pan (see Fig. 34).
Fig.33
PROPER FLAME HEIGHT
Cap
Utensils which conduct heat slowly (such as glass-ceramic) should be used with medium to low flames. If you are cooking with a large amount of liquid, a slightly larger flame can be used.
21
Fig.34
INSTALLATION
BURNER ADJUSTMENT - GRILL/GRIDDLE UNIT
Each outdoor appliance burner is tested and adjusted at the factory prior to shipment; however, variations in the local gas supply or a conversion from one gas type to another may make it necessary to adjust the burners. The flames of the burners should be visually checked and compared to that of the drawing in Fig. 35. Flames should be blue and stable with no yellow tips, excessive noise or lifting. If any of these conditions exist, check if the air shutter or burner ports are blocked by dirt, debris, spider webs, etc. Proceed with air shutter adjustment. The amount of air which enters a burner is governed by a sheet metal cup at the inlet of the burner called an air shutter. It is locked in place by a screw which must be loosened prior to lighting the burner for adjustment.
OUTDOOR APPLIANCE BURNER FLAME HEIGHT:
To access the outdoor appliance burner air shutters, first remove I the valve panel by removing it the same way as described on page
20, section "Before Testing". With a screw driver, loosen the lock- screw on the face of the air shutter. Light the burner and adjust according to the directions (Fig. 35).
To Adjust:
1.
Be careful as the burner may be very hot.
2.
If the flame is yellow, indicating insufficient air, turn the air shutter counterclockwise to allow more air to the burner.
3.
If the flame is noisy and tends to lift away from the burner, indicating too much air, turn the air shutter clockwise.
I
Fig. 35 Burner Flame Height
4. Once adjusted turn the burner off and reverse steps to reassemble.
LOW SETTING ADJUSTMENT:
The valves on the outdoor appliance feature an adjustable low setting. Due to fluctuations in gas pressure, heating value or gas conversion, you may feel it necessary to increase or decrease gas flow in the low position.
Bezel
To Adjust:
1.
Light the burner.
2.
Turn the control knob to the lowest setting (all the way counter-clockwise).
3.
Remove the knob.
4.
While holding the valve shaft with pliers, insert a thin, flat tipped screwdriver
into the shaft and while viewing the burner adjust to a minimum stable flame (Fig. 36).
Valve Stem
Fig.36 Low Setting Adjustment
WARNING: IMPORTANT!
Before lighting, inspect the gas supply piping or hose prior to turning the gas "on". If there is evidence of cuts, wear, or abrasion, it must be replaced prior to use.
22
INSTALLATION
RADIANT ASSEMBLY
RADIANT ASSEMBLY INSTALLATION:
I. Unpack ceramic rods and remove radiant (Fig.37) from the unit.
2. Unlock radiant end cap by pushing it up with two fingers (Fig. 38).
3. Place 18 ceramic rods on the radiant (Fig. 39).
4. Lock radiant end cap (Fig. 40).
5. Place the assembled radiant in the unit (Fig. 41).
Fig. 37
IMPORTANT:
Placement of the trays in the grill are critical to ensure even cooking performance. Lock radiant end caps must be in the middle of the grill. See Figure 41.
Fig. 38 Fig. 39
Fig.40 Fig.41
Note: In case a ceramic rod breaks:
a) Unlock radiant end cap by pushing it up with two fingers (Fig. 38) or pliers may be used. b) Replace broken ceramic rod.
c) Lock radiant end cap.
23
INSTALLATION
SINK
FAUCET INSTALLATION
1.
Attach the faucet to the sink as shown in Fig. 42 and 42a.
CAUTION:
Finger tight first, then use a 1"wrench.
Fig. 42
2. Insert drain plug into the drain hole Fig. 43.
Faucet stem
J
Valve
Rubbergasket
Lock washer
Nut
Fig.42a
Fig.43
WARNING!
The sink is intended for hand washing and cleaning activities. The sink should not be used for potable water or food preparation activities unless installed by a certified plumber and per local codes.
SINK INSTALLATION
Permanent Water/Drain Installation (Island Installation)
Use a certified plumber to connect and install water supply and drain system per local code requirements.
Make sure you have the drain connections in accordance with local codes. Sink water inlet connection is 1/2 male NPS.
Sink water drain connection is 1-1/2 male NPS.
Sink Water Installation on Cart CAD-30
An optional Sink Drain Accessory Kit Model #70853 is available from your local dealer.
1.
Set the burner box securely on a table and attach (installer provided) water supply hose through the hole at the
bottom of the burner box, and attach it to the faucet using a wrench.
24
INSTALLATION
SIDE SHELF (Optional accessory)
Attach Side Shelf Accessory on Either Side. Side shelf Model CAD-SK can be installed with the head already on the cart.
1.
Screw shoulder bolts (2) into the bottom screw holes on the side of the cart only (Fig. 44 and 45). Tighten with
5/32 Allen wrench.
Fig.44
2. Slide left and right side shelf brackets over the shoulder bolt (Fig. 46) and install top screw attaching the side shelf brackets onto the cart (Fig. 47). Tighten with Phillips screwdriver.
Fig. 46 Fig.47
3. Holding the side shelf, install 2 shoulder bolts into the slot and screw into the side shelf tray (Fig. 48).Tighten
with a 3/16 Allen wrench (Fig. 49).
Fig. 45
Fig. 48
Fig.49
25
INSTALLATION
SIDE SHELF (Optional accessory)
4.
Place shelf in the up position and check that it is level. If shelf is not level, adjust side shelf set screw. Set screws can be adjusted using a 3/32 Allen wrench (Fig. 50).
Turn the Allen wrench clockwise to raise the shelf. Turn 1/4 turn and review to see if the shelf is level. The set screws in the left and right bracket should be adjusted equally to ensure the shelf sits level (Fig. 51).
Fig. 50 Fig. 51
CHECK LIST
Fj Specified clearances Fj Air shutters adjusted.
maintained to combustibles.
Fj Verified proper enclosure
ventilation.
Fj All internal packaging Fj Pressure regulator
removed.
Fj Knobs turn freely, bezels 4.0" W.C. Natural, 11.0"
centered. W.C. LP gas.
Fj Each burner lights Fj Manual shut-off valve
satisfactorily, individually installed and accessible. or with adjacent burner
lit.
Fj Adjustable low setting
satisfactory.
Fj Drip pan in place properly
and sliding freely.
connected and set for
Fj Unit tested and free of
gas and water leaks.
Fj User informed of gas
supply shut-off valve location.
Fj All radiants are assembled
and put in place.
PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER.
USER, PLEASE RETAIN
THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
26
Loading...
+ 63 hidden pages