dB TECHNOLOGIES DVA S2585N User Manual

DVA
S2585N
DVA Products Guide
Why DVA S2585N?
DVA S2585N is born with the aim to help users who want to attenuate the power SPL behind the stage, focusing then the directivity on the front. The problem of this concept is that users subwoofers configurations are not standard: they can place subwoofers in front of the stage (Central configuration) or at the stage sides. DVA S2585N then had to be able to solve every particular situation wha- tever was the subwoofers position.
An omnidirectional subwoofer’s power response is generally consi- dered to be a perfect sphere in three dimensions.
Standard Omnidirectional Subwoofer
A cardioid sub is a low-frequency spe- aker with a heart-shaped directivity.
The power attenuation for this kind of speaker is placed at the back (180°).
Cardioid Subwoofer
A supercardioid sub is meant to be a bidirectional low-frequency speaker.
In this case, the power attenua- tion is placed at ±135°.
Supercardioid Subwoofer
Hyperardioid Subwoofer
A hypercardioid sub is a bidirectio- nal low-frequency speaker too.
In this case, the power attenuation Is placed at ±120°.
What’s the best solution among cardioid, supercardioid and hypercardioid
There isn’t a perfect solution for every situation. That’s why S2585N can be configured like a car- dioid, a supercardioid and also a hypercardioid
subwoofer. The S2585N default configuration is the super- cardioid one and it can be used in cardioid or hypercardioid ones via RDNET just clicking one
of the desired “cardioid preset” buttons.
Let’s explain the three cases.
Cardioid Case
The cardioid configuration is sugge- sted to be used for situations where the subs are placed in front of the stage in central configuration.
In this case, the phase cancellation under the stage brings the SPL in this area down to -22dbspl compared with the front of the stage.
Measured cardioid
directivity of DVA S2585N
from 40Hz up to 100Hz
Supercardioid Case
The supercardioid configuration is suggested to be used for stages widths from 8 up to about 14m.
In this case, the phase cancellation under the stage brings the SPL in this area down to -20dbspl compa- red with the front of the stage.
Measured supercardioid
directivity of DVA S2585N
from 40Hz up to 100Hz
Hypercardioid Case
The hypercardioid configuration is suggested to be used for stages widths bigger than 14m.
In this case, the phase cancellation under the stage brings the spl in this area down to -18dbspl compared with the front of the stage.
Measured hypercardioid
directivity of DVA S2585N
from 40Hz up to 100Hz
Conclusions
DVA S2585N can be used to:
- avoid spl behind the subs
- avoid spl under the stage
- avoid phase cancellations due on walls behind the subs
DVA S2585N features are:
- high spl: 2500wrms
- controlled directivity thanks to cardioid / supercardioid / hypercardioid configs.
- up to 4.5ms integrated group delay
- up to 10 integrated x-over frequencies
- RDNET on board
- every feature related to RDNET is available
- riggable like DVA S10DP
Loading...