DB LECTRO HL User Manual

0 (0)
DB LECTRO HL User Manual

RoHS Compliant ALUMINIUM ELECTROLYTIC CAPACITOR

HL Series

FEATURES

 

 

Load life of 5000 hours at 105°C

Safety vent construction design

 

For electronic ballast circuits, switching power supply, automotive and other long life required applications

OUTLINE

 

 

mm

D

10 13

16 18

F

5.0

7.5

d

0.6

0.8

SPECIFICATIONS

Items

 

 

Characteristics

 

 

 

 

Capacitance Tolerance

 

 

± 20% (M)

 

 

 

 

(120Hz, 25°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated Working Voltage Range

160 ~ 400Vdc

 

 

 

450Vdc

 

 

Operation Temperature

-40°C ~ +105°C

 

 

 

-40°C ~ +105°C

 

 

(After 2 minutes applying the DC working voltage)

 

 

Leakage Current (25°C)

 

I ≤ 0.06CV + 10 (u A)

 

 

 

 

I : Leakage Current (u A)

C : Rated Capacitance (u F)

V : Working Voltage (V)

 

Surge Voltage (25°C)

W.V.

160

200

250

350

400

450

S.V.

200

250

300

400

450

500

 

Dissipation Factor (120Hz, 25°C)

W.V.

160

200

250

350

400

450

tan δ

0.15

0.15

0.15

0.20

0.24

0.24

 

 

W.V.

160

200

250

350

400

450

Temperature Characteristics

- 25°C / + 25°C

3

3

3

5

5

6

- 40°C / + 25°C

6

6

6

6

6

-

 

Impedance ratio at 120Hz

After 5000 hours application of WV at +105°C, the capacitor shall meet the following limits:

Capacitance Change

≤ ± 20% of initial value

Load Test

 

tan δ

≤ 200% of initial specified value

Leakage Current

≤ initial specified value

After 1000 hours, no voltage applied at +105°C, the capacitor shall meet the following limits:

Capacitance Change

≤ ± 25% of initial value

Shelf Test

 

tan δ

≤ 200% of initial specified value

Leakage Current

≤ 200% of initial specified value