Datasheet HL Datasheet (DB LECTRO)

RoHS Compliant ALUMINIUM ELECTROLYTIC CAPACITOR HL Series
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
FEATURES
Load life of 5000 hours at 105°C
For electronic ballast circuits, switching power supply, automotive and other long life required applications
OUTLINE
SPECIFICATIONS
Items
Capacitance Tolerance (120Hz, 25°C)
Rated Working Voltage Range
Safety vent construction design
160 ~ 400Vdc 450Vdc
Characteristics
± 20% (M)
5.0 7.5
F
0.6
d
mm
0.8
Operation Temperature
Leakage Current (25°C)
Surge Voltage (25°C)
Dissipation Factor (120Hz, 25°C)
Temperature Characteristics
Load Test
-40°C ~ +105°C -40°C ~ +105°C (After 2 minutes applying the DC working voltage)
I 0.06CV + 10 (uA)
I : Leakage Current (uA)
W.V.
S.V.
W.V.
tan
δ
W.V.
- 25°C / + 25°C
- 40°C / + 25°C 66
Impedance ratio at 120Hz
C : Rated Capacitance (uF)
V : Working Voltage (V)
200 250 350
400 450200 250 300 500
160 200
160
200
250 350
250 350
3335
6
6
After 5000 hours application of WV at +105°C, the capacitor shall meet the following limits:
Capacitance Change
δ
tan
Leakage Current
≤ ± 20% of initial value 200% of initial specified value initial specified value
After 1000 hours, no voltage applied at +105°C, the capacitor shall meet the following limits:
400
450160
400 450
0.240.15 0.15 0.15 0.20 0.24
400
5
450
6
6-
Capacitance Change
≤ ± 25% of initial value
Shelf Test
δ
tan
Leakage Current
200% of initial specified value 200% of initial specified value
DIMENSIONS D x L (mm)
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
WV uF
3.3
4.7 10 22 33 47 68
100 150 220
160
]
10 x 20 10 x 20 13 x 20 10 x 20
13 x 25 16 x 2613 x 25 16 x 26 16 x 31 16 x 35 16 x 31 18 x 41 18 x 31330
13 x 20
16 x 26 16 x 31 18 x 31 18 x 41
18 x 31
10 x 20 10 x 20 13 x 20 13 x 20 16 x 2613 x 25 16 x 31
18 x 31
350200 250
16 x 26 16 x 31 16 x 31 18 x 35 18 x 41
400
]
]
10 x 20
450
10 x 20 13 x 20 13 x 20 16 x 2613 x 25
18 x 3113 x 20 13 x 2513 x 20
RC: mA (rms) at 120Hz 105°C
PERMISSIBLE RIPPLE CURRENT
WV
uF Item RC Imp RC Imp RC Imp RC Imp RC Imp RC Imp
3.3
4.7 10 22 33 47 68
100 150 220 330
160 1.52 160 1.52 165 2.40 165 2.10 185 1.32 200 1.75 190 1.30 210 0.98 210 1.90 230 1.00 230 0.95 275 1.20 265 0.93 265 0.93 282 1.70 313 0.74 300 0.75 340 0.96 355 0.61 355 0.61 385 0.79 410 0.49 420 0.49 460 0.80 475 0.28 475 0.28 520 0.64 530 0.40 545 0.36 637 0.22 650 0.22 645 0.44 750 0.22 780 0.22 820 0.35 960 0.22
105 3.50 100 3.00 105 2.90 110 3.00
]
Imp: m(ohm) at 100KHz 25°C
60 6.50
]
80 3.60
]
450400350250200160
Loading...