Datasheet UB800-F12-I-V15 DataSheet (Pepperl Fuchs)

Page 1
Ultrasonic sensor UB800-F12-I-V15
Technical data
General specifications
Sensing range 30 ... 800 mm Adjustment range 50 ... 800 mm Dead band 0 ... 30 mm Standard target plate 100 mm x 100 mm Transducer frequency approx. 310 kHz Response delay approx. 100 ms
Indicators/operating means
LED green Operating display LED yellow Evaluation range indicator, Ready for programming LED red Ready for programming, Fault
Electrical specifications
Model Number
UB800-F12-I-V15
Single head system
Features
• Evaluation limits can be taught-in
• Selectable sound lobe width
• Synchronization options
• Very small unusable area
• Temperature compensation
Diagrams
Characteristic response curve
Distance Y [mm]
200
flat surface 100 mm x 100 mm
150
100
50
0
-50
-100
-150
round bar, Ø 25 mm
-200 0 200 400 600 800 1000 1200
Y
X
wide sound lobe narrow sound lobe
Distance X [mm]
Operating voltage U No-load supply current I
Input/Output
B
0
Synchronization 1 synchronous connection, bi-directional
Synchronization frequency
Common mode operation 45 Hz Multiplex operation 45/n Hz, n = number of sensors
Input
Input type 1 program input
Pulse length 1 s
Output
Output type 1 analog output 4 ... 20 mA Default setting evaluation limit A1: 50 mm , evaluation limit A2: 800 mm ,
Repeat accuracy 1 % Load impedance 1000 Temperature influence ± 1.5 % of full-scale value
Ambient conditions
Ambient temperature -15 ... 70 °C (5 ... 158 °F) Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 5-pin Degree of protection IP54 Material
Housing Frame: nickel plated, die cast zinc,
Transducer epoxy resin/hollow glass sphere mixture; foam polyurethane,
Mass 60 g
Compliance with standards and directives
Standard conformity
Standards EN 60947-5-2:2007 + A1:2012
Approvals and certificates
UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated 36 V
10 ... 30 V DC 30 mA
0-level: -U 1-level: +4 V...+U input impedance: > 12 k synchronization pulse: 100 µs, synchronization interpulse period: 2 ms
Switching distance 1: -U ... +U Input impedance: > 10 k
...+1 V
B
B
... +1 V, Sw itch ing d ista nce 2 : +3 V
B
B
wide sound lobe , rising ramp
Laterals: glass-fiber reinforced plastic PC
cover PBT
IEC 60947-5-2:2007 + A1:2012 EN 60947-5-7:2003 IEC 60947-5-7:2003
Release date: 2016-04-25 09:25 Date of issue: 2016-04-25 202067_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Page 2
Ultrasonic sensor UB800-F12-I-V15
Dimensions
M4 / 4 deep
15
1.5
5.3
5.5
7.5
19.5
Additional Information
Analogue output programmation
10
41.5
ø4.5
7
49
65
2
M12 x 1
24
A1
N
M
Connector 90° adjustable position
11.5
A2
B
32.5
N normal operation
A1 evaluation limit 1
A2 evaluation limit 2
B light beam characteristics
M operating mode
Teach-IN
Rising ramp
Falling ramp
Zero line
A1 = 0
Unusable area
A1A1
A1 A2
Object distance
A2
A2
Electrical Connection
Standard symbol/Connections:
(version I)
U
Core colours in accordance with EN 60947-5-2.
Pinout
Wire colors in accordance with EN 60947-5-2
1 BN 2 WH 3 BU 4 BK 5 GY
(BN)
1
(WH)
2
(GY)
5
(BK)
4
(BU)
3
2
+ U
B
Teaching input
Sync.
Analog output
- U
B
1
5
4
3
(brown) (white) (blue) (black) (gray)
Release date: 2016-04-25 09:25 Date of issue: 2016-04-25 202067_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Page 3
Ultrasonic sensor UB800-F12-I-V15
Accessories
OMH-K01
dove tail mounting clamp
OMH-K02
dove tail mounting clamp
OMH-K03
dove tail mounting clamp
OMH-01
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mm
OMH-06
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mm
OMH-MLV12-HWG
Mounting bracket for series MLV12 sensors
OMH-MLV12-HWK
Mounting bracket for series MLV12 sensors
V15-G-2M-PVC
Female cordset, M12, 5-pin, PVC cable
Function description
The sensor can be fully programmed by means of a push button and a selector switch on the top of the housing. A special feature of this sensor is the option of adapting the breadth of the ultrasonic beam to suit the ambient conditions at the point of use.
Normal operation
During normal operation the output stage of the sensor operates in accordance with the taught-in evaluation limits, the programmed mode of operation and characteristic of the sonic beam. In this made the selector switch must remain at the N position.
LED Condition
Green LED Continuous: Ready for operation Yellow LED Object detected within the evaluation limits
If the selector switch is not in the N position when the power supply is switched on, then this is indicated by simultaneous flashing of the green and yellow LEDs. However, the function of the output stage is as for the switch position N.
Teaching in of the evaluation range limits:
Within a time window of 5 minutes after switch-on of the power supply the sensor is ready for adaptation of the evaluation range limits to the requirements of the respective application.
- Place the object that is to be detected at one of the desired limits of the evaluation range.
- Set the selector switch to position A1.
- Now actuate the TEACH-IN button.
LED before pressing button on pressing button after pressing button
Green Off Off On Yellow Flashes: Positive detection
On Evaluation limit displayed
of object
Red Flashes: No object detected
Off Off
On: Object not positively
detected
- The teach-in procedure for the evaluation range limit can be repeated by repeatedly actuating the TEACH-IN button.
- Proceed in the same way for the second evaluation range limit, but set the selector switch to position A2.
- Return the selector switch to position N. Note: Acceptance of the evaluation range limits into the permanent memory of the sensor does not take place until the selector switch is reset to N. If this acceptance does not take place within a time window of 5 minutes, the sensor continues to operate with unchanged values and the red and yellow LEDs flash.
The teach in sequence of the evaluation range limits (Near limit/Far limit) is arbitrary. Alternatively, the evaluation range limits can be set electrically, via the teach-in input. In this case the selector switch is left in the N position. The two eval-
uation limits are taught in by applying the potentials +U
(A1) and -UB (A2), respectively, for at least 500 ms to the teach-in input.
B
Parameter assignment of the output function
Within a time window of 5 minutes from switching on the power supply the sensor is ready for adaptation of the output function.
- Set the selector switch to position M (Mode). The current set operating mode is indicated by the flashing sequence of the green LED.
- The optional operating modes are selected by briefly actuating the TEACH-IN button (See flashing sequence of the green LED).
Operating mode Flashing sequence of the green LED T button
Rising ramp
Falling ramp
Zero point level
Release date: 2016-04-25 09:25 Date of issue: 2016-04-25 202067_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
pause
Pause
Pause
Pause
3
Page 4
Ultrasonic sensor UB800-F12-I-V15
- Return the selector switch to position N when the desired operating mode is displayed. Note: Acceptance of the operating mode into the permanent memory of the sensor does not take place until the selector switch is set to N. If this accept­ance does not take place within a time window of 5 minutes, the sensor continues to operate with unchanged operating mode and the red and yellow LEDs flash.
Parameter assignment of the ultrasonic beam breadth
Within a time window of 5 minutes from switching on the power supply the sensor is ready for adaptation of the ultrasonic beam breadth.
- Set the selector switch to position B (Beam). The flashing sequence of the green LED indicates the currently set ultrasonic beam breadth.
- The optional beam breadths are selected by brief actuation of the TEACH-IN button (See flashing sequence of the green LED).
Characteristic Flashing sequence of the green LED T-Button
Narrow beam
Medium beam
Broad beam
Pause
Pause
Pause
- Return the selector switch to position N when the desired beam breadth is indicated. Note: Acceptance of the ultrasonic beam breadth into the permanent memory of the sensor does not take place until the selector switch is set to N. If this acceptance does not take place within the 5 minute time window, the sensor continues its operation with an unchanged ultrasonic beam breadth and the red and yellow LEDs flash.
Synchronisation
A synchronisation connection is provided for the suppression of mutual interference. If this is unused, or connected to 0V, then the sensor operates with an internally generated clock-pulse rate. The synchronisation of a number of sensors can be achieved by the following means.
External synchronisation:
The sensor can be synchronised by the external application of a square-wave voltage. A synchronisation pulse at the synchronisation input leads to the execution of a measuring cycle. The pulse width must be greater than 1.2 ms. The measuring cycle starts with the falling ramp. A low level > 1 s or an open synchronisation input leads to the normal operation of the sensor. A high level at the synchronisation input deactivates the sensor.
Two operating modes are possible.
- A number of sensors are triggered by the same synchronisation signal. The sensors operate in common mode.
- The synchronisation pulses are fed cyclically to one sensor at a time. The sensors operate in multiplex mode.
Self-synchronisation:
The synchronisation connections of up to 5 sensors are connected together to provide the option of self-synchronisation. When the operating voltage is switched on these sensors operate in multiplex mode. The switch-in delay increases depending on the number of sensors to be synchronised. Synchroni­sation cannot take place during teach-in and vice-versa. The sensors must be operated unsynchronised for the teaching-in of the switch points.
Note:
If the synchronisation option is not used, then the synchronisation input is connected to earth (0V) or the sensor is operated with a V1 connection cable (4­pole).
Release date: 2016-04-25 09:25 Date of issue: 2016-04-25 202067_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
4