Ultrasonic sensor UB800-18GM40A-E5-V1
Technical data
General specifications
Sensing range 50 ... 800 mm
Adjustment range 70 ... 800 mm
Dead band 0 ... 50 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx. 255 kHz
Response delay approx. 100 ms
Indicators/operating means
LED green Power on
Model Number
UB800-18GM40A-E5-V1
Single head system
Features
•Short design, 40mm
• Function indicators visible from all
directions
• Switch output
• 5 different output functions can be
set
•Program input
• Temperature compensation
Diagrams
Characteristic response curve
Distance Y [mm]
200
150
100
50
0
-50
-100
-150
-200
0 200 400 600 800 1000 1200 1400
Curve 1: flat surface 100 mm x 100 mm
Curve 2: round bar, Ø 25 mm
2
Y
X
1
Distance X [mm]
LED yellow indication of the switching state
LED red solid red: Error
Electrical specifications
Operating voltage U
No-load supply current I
Input
B
0
Input type 1 program input
Output
Output type 1 switching output E5, PNP NO/NC, programmable
Rated operating current I
Default setting Switch point A1: 70 mm Switch point A2: 800 mm
Voltage drop U
Repeat accuracy ≤ 1 %
d
e
Switching frequency f ≤ 4 Hz
Range hysteresis H 1 % of the set operating distance
Temperature influence ± 1.5 % of full-scale value
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 4-pin
Degree of protection IP67
Material
Housing brass, nickel-plated
Transducer epoxy resin/hollow glass sphere mixture; foam polyurethane,
Mass 25 g
Compliance with standards and
directives
Standard conformity
Standards EN 60947-5-2:2007 + A1:2012
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated ≤36 V
flashing: program function object detected
red, flashing: program function, object not detected
10 ... 30 V DC , ripple 10 %
≤ 20 mA
operating distance 1: -U
... +U
B
input impedance: > 4,7 kΩ program pulse: ≥ 1 s
SS
... +1 V, operating d istance 2: +6 V
B
200 mA , short-circuit/overload protected
≤ 3 V
cover PBT
IEC 60947-5-2:2007 + A1:2012
Release date: 2016-04-25 09:38 Date of issue: 2016-04-25 205344_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1

Ultrasonic sensor UB800-18GM40A-E5-V1
Dimensions
M18 x 1
Additional Information
Programmable output modes
1. Window mode, normally open mode
A1 < A2:
A1
2. Window mode, normally closed mode
A2 < A1:
A2
3. One switch point, normally open mode
A1 -> ∞:
A2
A1
39.2
LED
10
M12 x 1
4. One switch point, normally closed mode
A2 -> ∞:
5. A1 -> ∞, A2 -> ∞: Object presence detection mode
Object detected: Switch output closed
No object detected: Switch output open
24.5
67.7
24
4
object distance
A2
A1
Electrical Connection
Standard symbol/Connections:
(version E5, pnp)
U
Core colours in accordance with EN 60947-5-2.
Pinout
Wire colors in accordance with EN 60947-5-2
1 BN
2 WH
3 BU
4 BK
1 (BN)
2 (WH)
4 (BK)
3 (BU)
2
1
3
(brown)
(white)
(blue)
(black)
+ U
B
Teach input
Switch output
- U
B
4
Release date: 2016-04-25 09:38 Date of issue: 2016-04-25 205344_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2

Ultrasonic sensor UB800-18GM40A-E5-V1
Accessories
UB-PROG2
Programming unit
OMH-04
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mm
BF 18
Mounting flange, 18 mm
BF 18-F
Mounting flange with dead stop, 18 mm
BF 5-30
Universal mounting bracket for cylindrical sensors with a diameter of 5 ... 30 mm
V1-G-2M-PVC
Female cordset, M12, 4-pin, PVC cable
V1-W-2M-PUR
Female cordset, M12, 4-pin, PUR cable
Adjusting the switching points
The ultrasonic sensor features a switch output with two teachable switching points. These are set by applying the supply voltage
-U
or +UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs indicate whe-
B
ther the sensor has recognised the target during the TEACH-IN procedure. Switching point A1 is taught with -U
Five different output functions can be set
1. Window mode, normally-open function
2. Window mode, normally-closed function
3. one switching point, normally-open function
4. one switching point, normally-closed function
5. Detection of object presence
TEACH-IN window mode, normally-open function
- Set target to near switching point
- TEACH-IN switching point A1 with -U
B
- Set target to far switching point
- TEACH-IN switching point A2 with +U
B
TEACH-IN window mode, normally-closed function
- Set target to near switching point
- TEACH-IN switching point A2 with +U
B
- Set target to far switching point
- TEACH-IN switching point A1 with -U
B
TEACH-IN switching point, normally-open function
- Set target to near switching point
- TEACH-IN switching point A2 with +U
B
- Cover sensor with hand or remove all objects from sensing range
- TEACH-IN switching point A1 with -U
B
TEACH-IN switching point, normally-closed function
- Set target to near switching point
- TEACH-IN switching point A1 with -U
B
- Cover sensor with hand or remove all objects from sensing range
- TEACH-IN switching point A2 with +U
B
TEACH-IN detection of objects presence
- Cover sensor with hand or remove all objects from sensing range
- TEACH-IN switching point A1 with -U
- TEACH-IN switching point A2 with +U
B
B
, A2 with +UB.
B
LED Displays
Displays in dependence on operating mode Red LED Yellow LED
TEACH-IN switching point:
Object detected
No object detected
Object uncertain (TEACH-IN invalid)
off
flashes
On
Normal operation off Switching state
Fault on Previous state
Release date: 2016-04-25 09:38 Date of issue: 2016-04-25 205344_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
flashes
off
off
3