Contact Capacity
Model
Nominal switching capacity (res. load)
Max. switching current
Max. switching voltage
Max. switching power
Miniature High
SLA-Series
Power Relay
Features
Miniature relay with high switching capability:30A.
Contact formForm A, Form B or 1Form C. Special type of 4000VAC dielectric strength and 6000V surge
voltage (1.2/50 S) between coil and contact (DJ, DMJ, DBJ u not include Open type ) available.
Sealed type and open type available.
Patent Number ZL 2008 20050972.1
Satisfice IEC60335-1product is available.
Satisfice IEC60079-15 product is available.
Safety Approval
UL,C-UL File No.:E190598 TUV File No.:R50143450 CQC File No.:CQC02001002109
VDE File No.:40036707
SLA-DM
Standard type/S Mark
30A 250VAC
30A
250VAC
7,500VA
H Mark
20A 250VAC
20A
250VAC
5,000VA
SLA -DB
15A 250VAC
20A
250VAC
5,000VA
SLA -D
20A/10A 250VAC
20A
250VAC
5,000VA
Charateristic Data
Contact material
Initial contact resistance (at 6VDC 1A)
Operate time (at nominal volt.)
Release time (at nominal volt.)
Initial insulation resistance
Initial dielectric strength
Vibration resistance
Shock resistance
Endurance (operations)
Ambient temperature
Unit weight
Coil Data (at 20 ℃)
Nominal
voltage
(VDC)
5
6
9
12
15
18
24
48
110
Nominal
operating
current
±10% (mA)
180.00
150.00
100.00
75.00
60.00
50.00
37.50
18.75
8.20
Coil
resistance
±10% (Ω)
27
40
90
160
250
360
640
2,560
13,400
Silver alloy
50m Max.Ω
15msec. Max.
10msec. Max.
100M Min.(DC500V)Ω
Between open contacts:
Between coil and contact:
Functional
Destructive
Functional
Destructive
Mechanical
Electrical
-40℃~+105℃ (no condensation)
Open type: Approx.20.0g
(at 10,800 ops./h)
(at 600 ops./h)
allowable
voltage
130 % of
nominal
voltage
Standard Type:AC1,500V,50/60Hz
Mark H & S:AC2,000V, 50/60Hz 1min.
AC2,500V,50/60Hz 1min. (4kV available) AC1,500V,50/60Hz 1min. (open type available)
Pick-up voltage
(Max.)
75 % of
nominal
voltage
1min.
10~55Hz at double amplitude of 1.5 mm
10~55Hz at double amplitude of 1.5 mm
10G Min.
100G Min.
10,000,000 cycles
100,000 cycles
S Mark: 50,000 cycles
Sealed type: Approx. 24.0g
Drop-out
voltage
(Min.)
Nominal
operating
power
5 % of
nominal
0.90W
voltage
1/3
1/4
Page 2
Coil Data of H mark (at 20℃)
Nominal
voltage
(VDC)
6
12
24
48
Nominal
operating
current
±10% (mA)
183.33
91.67
45.83
22.92
Coil
resistance
±10% (Ω)
33
131
524
2095
Max.
allowable
voltage
130 % of
nominal
voltage
Pick-up voltage
(Max.)
75 % of
nominal
voltage
Drop-out
voltage
(Min.)
5 % of
nominal
voltage
SLA
Nominal
operating
power
1.1W
Coil Data of S mark (at 20℃)
Nominal
voltage
(VDC)
6
12
24
48
Nominal
operating
current
±10% (mA)
266.67
133.33
66.67
33.33
Coil
resistance
±10% (Ω)
22.5
90
360
1440
Max.
allowable
voltage
130 % of
nominal
voltage
Pick-up
voltage
(Max.)
75% of
nominal
voltage
Drop-out
voltage
(Min.)
5% of
nominal
voltage
Safety Approval Ratings
(Note:More detail of approval ratings,please refer to the safety certification)
Approval
File No.
Approved
ratings
CQC
CQC02001002109
Form A
30A 250VAC
Form B
15A 250VAC
Form C
20A/10A 250VAC
TUV
R50143450
Form A: 30A 240VAC Making: 80A 250VAC(300ms) Breaking:20A 250VAC
Form B 15A 240VAC
Form C
20A/10A 240VAC
UL/CUL
E190598
Form A:
40A 277VAC, Resistive 30A 240VAC, Resistive/General Use 15A 240VAC 1-1/2HP 240VAC;3/4 HP 120VAC TV-8 120VAC 30A 120VAC, Resistive/General Use
Pilot duty: 470 VA, 240VAC Electronic Ballast: 10A 277VAC /120VAC Form B:
30A 120VAC, General Use 20A 240VAC, General Use 20A 120VAC, Resistive 10A 240VAC, Resistive/General Use
Pilot duty: 275VA, 240VAC Electronic Ballast: 5A, 277VAC/120VAC 1/2HP 240VAC;1/4HP 120VAC Form C:
N.O. N.C. 30A 240/120VAC,Resistive 30A 240/120VAC,General Use 20A 240/120VAC, Resistive 20A 240VAC, Resistive 20A 240/120VAC,General Use 10A 240VAC, Resistive 10A 240VAC, Resistive 1-1/2HP 240VAC 1/2HP 240VAC 3/4HP 125/120VAC 1/4HP 125/120VAC TV-8 120VAC TV-3 120VAC 20A 240VAC, General Use 10A 240VAC, General Use
Pilot Duty: 470VA 240VAC Pilot Duty: 275VA 240VAC Electronic Ballast: Electronic Ballast: 10A 277VAC/120VAC 5A 277VAC/120VAC
Nominal
operating
power
1.6W
VDE
40036707
30A 250VAC,NO
20A 250VAC,CO(test NO)
10A 250VAC,CO(test NC)
Ordering Information
Nomenclature
- S - 1 12 D
SLA
SLA
-1
J
D
M 1 -FJ
-G
Protective Construction:Nil-Open type, S-Flux proofed,
Note:1.1W,1.5GAP and 1.6W,1.5GAP are not suitable for B/C type or 40A.
-XX
F
Special Parameter : Nil-Standard type, Letter or number-Special resquirement
Insulation System:Nil-Standard, B-Class B, F-Class F
Parameter signNil-Standard G-High contact load(40A),Double-layer spring,Ø5.0 Contact
Contact Material:Nil-AgSnO2, 1-AgCdO
Terminal Type:Nil-Standard, J-Without 6# terminal
Contact Form:Nil-Form C, B-Form B, M-Form A
Coil PowerD-0.90W,H-1.1W,1.5GAP,S-1.6W,1.5GAP
Coil Voltage (VDC):05, 06, 09, 12, 15, 18, 24, 48, 110
Number of Poles:1-1 Pole
SH-Sealed type washable
Type DesignationSLA
2/3
2/4
Page 3
Outline Dimensions, Wiring Diagram, P.C. (unitmm)Board Layout
Open type
23.6
5.6(normal type)/3.3
27.7
6# terminal
14.9
Unless otherwise specified: If dimension <1mm, tolerance: ±0.2mm; If dimension 1~5mm, tolerance: ±0.3mm; If dimension >5mm, tolerance: ±0.4mm. Note: 1. Extended terminal dimension is dimension
before soldering.
2. Tolerance of P.C.B. layout:±0.1mm.
Sealed type
SLA
4- 2.1Φ
7.62
15.24
6# terminal
6# terminal
bottom view
Wiring Diagram (bottom view)
17.8
8.9
2.54
2.54
3- 2.1Φ
10.16
15.24
17.8
8.9
3- 2.1Φ
15.24
2.54
17.8
8.9
2.54
2.54
2- 1.1Φ
6# terminal
10.2
2- 1.1Φ
6# terminal
10.2
P.C.B. Layout (bottom view)
Typical Applications
Car Heater and ventilation equipment
Air conditioner Home appliances
10.2
2- 1.1Φ
6# terminal
3/4
Page 4
SLA
Characteristic Curves
Coil Temp. Rise
110
100
90
80
70
30A
60
25A 20A
Temp. Rise (K)
50
15A
40
0A
0
80 90 100 110 120 130 140 150
Percentage of Nominal Coil Voltage
Note: If you choose the sealed type, before using, please remove the convex platform at the top of the case to ensure the
normal performance of the relay after the completion of a PCB operations. they are as shown in the following diagram:
160
100
Contact Current (A)
convex platform
Max. Switching Power
1a
40 30
1c(NO)
20
!
1b
15
1c(NC)
10
AC load
&
&
DC load
1
10 100 200 1000
Contact Voltage(V)
Endurance Curve
100
!
30
10
1c(NC)
1
Operations(×10000 Ops.)
0 10 20 30 40
Contact Current(A)
1a
1c(NO)
1b
!
with convex platform
without convex platform
Disclaimer:
This datasheet is the customers' reference. All the specification are subject to change without notice. We could not evaluate all the performance and all the parameters for every possible application.Thus the
user should in a right position to choose the suitable product for their own application.If there is any query, please contact Sanyou for the technical service.However it is the user's responsibility to determine which product should be used only.
Dongguan Sanyou Electrical appliance Co.,LTD,All rights of Sanyou to reserved
4/4