© 2000 SEMTECH CORP. 652 MITCHELL ROAD NEWBURY PARK CA 91320
PRECISION SHUNT VOLTAGE
REFERENCE
SC1004(A)
May 1, 2000
2
ELECTRICAL CHARACTERISTICS
TA = 25°C unless otherwise specifi ed.
-1.2 -2.5
Parameter Symbol Condition MIN TYP MAX MIN TYP MAX UNITS
Reverse Breakdown Voltage, V
ZIZ
= 100µA TA = 25°C 1.225 1.235 1.245 2.480 2.500 2.520 V
SC1004 T
A
= 0 to +70°C 1.220 1.235 1.250 2.470 2.500 2.530
T
A
= -40 to +85°C 1.215 1.235 1.255 2.460 2.500 2.535
Reverse Breakdown Voltage, V
ZIZ
= 100µA TA = 25°C 1.231 1.235 1.239 N/A N/A N/A V
SC1004A T
A
= 0 to +70°C 1.225 1.235 1.245 N/A N/A N/A
T
A
= -40 to +85°C 1.220 1.235 1.245 N/A N/A N/A
Average Temperature Coefficient
I
Z(min)
≤ IZ ≤ 20mA
20 20 ppm/°C
Minimum Operating Current I
Z(min)
TA = -40 to +85°C 8 10 12 20 µA
Ratio of Change in V
Z
to Change in I
Z
I
Z(min)
< IZ < 1mA TA = 25°C 1.0 1.0 mV
T
A
= -40 to +85°C 1.5 1.5
1mA <
IZ < 20mA TA = 25°C 10 10
T
A
= -40 to +85°C 20 20
Reverse Dynamic Impedance Z
RIZ
= 100µA TA = 25°C 0.2 0.6 0.2 0.6
Ω
T
A
= -40 to +85°C 1.5 1.5
Wideband Noise (RMS) e
NIZ
= 100µA, 10Hz < f < 10kHz 60 120 µV
Long Term Stability of Reverse Breakdown Voltage
∆V
Z
t = 1000 hours, T = 25°C ± 0.1°C,
I
Z
= 100µA
20 20 ppm
T
V
Z
∆
∆
Z
Z
IV∆
∆