The RB series DC/DC converter has been designed for isolating or converting DC power rails in
general purpose applications. Although low cost, it does not compromise on features and offers
1KVDC/1s or 2kVDC/1s isolation, a –40°C to +85°C operating temperature range and optional
continuous short circuit protection.
Selection Guide
Part nom. Input Output Output Efficiency max. Capacitive
Number Voltage Voltage Current typ.
[VDC] [VDC] [mA] [%] [µF]
(3,4)
RB-xx3.3S
RB-xx05S
RB-xx09S
RB-xx12S
RB-xx15S
RB-xx24S
RB-xx3.3D
RB-xx05D
RB-xx09D
RB-xx12D
RB-xx15D
RB-xx24D
3.3, 5, 12, 15, 24 3.3 303 75 2200
(3,4)
3.3, 5, 12, 15, 24 5 200 70-78 2200
(3,4)
3.3, 5, 12, 15, 24 9 111 70-78 1000
(3,4)
3.3, 5, 12, 15, 24 12 84 78-80 470
(3,4)
3.3, 5, 12, 15, 24 15 66 80-84 470
(3,4)
3.3, 5, 12, 15, 24 24 42 74-85 220
(3,4)
3.3, 5, 12, 15, 24 ±3.3 ±152 70 ±1000
(3,4)
3.3, 5, 12, 15, 24 ±5 ±100 70-78 ±1000
(3,4)
3.3, 5, 12, 15, 24 ±9 ±56 76-79 ±470
(3,4)
3.3, 5, 12, 15, 24 ±12 ±42 78-82 ±220
(3,4)
3.3, 5, 12, 15, 24 ±15 ±33 80-84 ±220
(3,4)
3.3, 5, 12, 15, 24 ±24 ±21 80-84 ±100
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the
capacitive load that will allow start up in under 1s without damage to the converter
(1)
Load
(2)
RB
1 Watt
SIP7
Single and
Dual Output
E358085
UL60950-1 certified
CAN/CSA-C22.2 No 60950-1 certified
IEC/EN60950-1 certified
EN55032 compliant
Model Numbering
RB- __ /
nom. Input Voltage
Output Voltage
“Protection
“Isolation Option
Single or Dual
Notes:
Note3: standard part is without Continuous Short Circuit Protection
add suffix „/P“ for Continuous Short Circuit Protection
Note4: standard part is with 1kVDC/1s Isolation
add suffix „/H“ for 2kVDC/1s Isolation
or add suffix „/HP“ for 2kVDC/1s Isolation and Continuous Short Circuit Protection
Ordering Examples:
RB-123.3/P: 12VDC Input Voltage, 3.3VDC Output Voltage, Single Output with continuous short circuit protection and 1kVDC/1s isolation
RB-0509D/HP: 5VDC Input Voltage, ±9VDC Output Voltage, Dual Output with continuous short circuit protection and 2kVDC/1s isolation
Operating Temperature Rangefull load @ free air convection, refer to “Derating Graph”-40°C to +85°C
Maximum Case Temperature+105°C
Temperature Coefficient±0.03%/K typ.
Thermal Impedance56K/W typ.
Operating Altitude3000m
Operating Humiditynon-condensing95% RH max.
Pollution DegreePD2
MTBFaccording to MIL-HDBK-217F, G.B.
without suffix
with suffix “/P”
(6)
Notes:
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local saftey regulations if input over-current protection is also required. Recommended fuse: slow blow type
Packaging Dimension (LxWxH)tube 520.0 x 16.0 x 9.0mm
Packaging Quantitytube 25pcs
Storage Temperature Range-55°C to +125°C
Storage Humiditynon-condensing95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer.
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 1/2019ECO-7