IF signal output terminal of mixer.
External matching circuit is required.
Please connect mixer power supply through inductor (L6,
L7) as shown in test circuit.
Please place bypass capacitors (C6, C7, C8) close to C2.
Local amplifier power supply terminal.
Please place R1 and L5 close to this terminal as shown in
test circuit, and place bypass capacitors (C3, C4) close to
R1 and L5.
Local power input terminal of local amplifier.
External matching circuit is required.
Ground terminal (0V).
Please place grounding VIAs as close as possible.
RF signal input terminal of mixer.
External matching circuit is required.
PCB: FR-4 t=0.5mm
Microstrip Line Width=1mm
PCB Size: 22.5x30.0mm
PRECAUTIONS
[1] Please place a inductor L1 at about 3.5mm distance from RFIN terminal (Pin #6).
[2] Please place a inductor L3 at about 3.5mm distance from LOIN terminal (Pin #4).
[3] Please place a capacitor C1 close to by-pass capacitor terminal (Pin #2).
[4] Please place capacitors C6, C7, C8 close to C2.
[5] Please place capacitors C3, C4 close to R1 and L5.
NJG1553BF
- 8 -
n
MEASURING BLOCK DIAGRAM
SG
(RF1)
SG
(RF2)
Noise
Source
ISO.1
6dB ATT
Power
Comb.
ISO.2
RFIN
SG
(LO)
IF, IM3 Measuring Block Diagram
BPF
V
MIX=VLO
6dB ATT
=2.7V
RFIN
DUT
LOIN
DUT
IFOUT
LOIN
V
MIX=VLO
IFOUT
=2.7V
Spectrum
Analyzer
NF
Meter
BPF
SG
(LO)
Noise Figure Measuring Block Diagram
NJG1553BF
- 9 -
nPACKAGE OUTLINE (MTP6)
care to avoid these damages.
Lead material: Copper
Lead surface finish: Solder plating
Molding material: Epoxy resin
Unit: mm
Weight: 14mg
Cautions on using this product
This product contains Gallium-Arsenide (GaAs) which is a harmful material.
• Do NOT eat or put into mouth.
• Do NOT dispose in fire or break up this product.
• Do NOT chemically make gas or powder with this product.
• To waste this product, please obey the relating law of your country.
This product may be damaged with electric static discharge (ESD) or spike voltage. Please handle with
[CAUTION]
The specifications on this databook are only
given for information , without any guarantee
as regards either mistakes or omissions. The
application circuits in this databook are
described only to show representative usages
of the product and not intended for the
guarantee or permission of any right including
the industrial rights.