Switching function 2 x normally closed (NC)
Output type NAMUR
Rated operating distance sn3 mm
Installation flush mountable
Assured operating distance sa0 ... 2.4 mm
Actual operating distance s
Actuating element Stainless steel 1.4305 / AISI 303
Reduction factor r
Reduction factor rCu 0.4
Reduction factor r
Reduction factor r
Reduction factor r
Output type 2-wire
Nominal ratings
Nominal voltage Uo8 V
Switching frequency f0 ... 3 kHz
Hysteresis Htyp. 5 %
Reverse polarity protection reverse polarity protected
Short-circuit protection yes
Suitable for 2:1 technology yes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detected
Measuring plate detected
Time delay before availability t
Switching state indicator LED, yellow
Functional safety related parameters
Safety Integrity Level (SIL) SIL 2
MTTF
1470 a
d
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Ambient conditions
Ambient temperature -25 ... 100 °C (-13 ... 212 °F)
Storage temperature -40 ... 100 °C (-40 ... 212 °F)
Mechanical specifications
Connection (system side) 10 m, PVC cable
Core cross-section (system side) 0.75 mm
Housing material PBT
Sensing face PBT
Degree of protection IP67
Cable
Bending radius
General information
Use in the hazardous area see instruction manuals
Compliance with standards and
directives
Standard conformity
NAMUR
Electromagnetic compatibility
Standards
Approvals and certificates
EAC conformity TR CU 012/2011
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated ≤36 V
0.5
Al
1
304
1.3
St37
0.6
Brass
2.7 ... 3.3 mm typ.
r
8.5 mm x 8.5 mm x 0.5 mm
≥ 3 mA
≤ 1 mA
≤ 1.1 ms
v
Note:
Under the same product name but with a different part no., this
product has a predecessor with a restricted temperature range (up
to +70 °C).
The temperature range specified here (up to +100°C) only applies
to sensors with part no. 2239**.
2
> 10 x cable diameter
EN 60947-5-6:2000
IEC 60947-5-6:1999
NE 21:2007
EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012
Release date: 2018-04-19 08:15 Date of issue: 2018-04-19 223955_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
1
Page 2
Inductive sensorNCN3-F31-N4-K-10M
Dimensions
65
I
33.5
Electrical Connection
LED
1 / BN
3 / BU
2 / WH
4 / BK
II
S
30
L+
L-
L+
L-
25
5
14
5.4
9
36
7
N4-K
I
I
I
S
II
II
Release date: 2018-04-19 08:15 Date of issue: 2018-04-19 223955_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
2
Page 3
Inductive sensorNCN3-F31-N4-K-10M
Data for application in connection with hazardous
areas
Equipment protection level Ga , Gb , Gc (ic) , Da , Mb
Equipment protection level Ga
Type of protection intrinsic safety
CE marking 0102
NCN3-F31-N4...
TÜV 99 ATEX 1479 X
¬ II 1G Ex ia IIC T6...T1 Ga
EN 60079-0:2012+A11:2013 , EN 60079-11:2012
IECEx TUN 17.0021X
Ex ia IIC T6...T1 Ga
IEC 60079-0:2011 , IEC 60079-11:2011
≤ 100 nF
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
≤ 100 µH
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Also observe the maximum permissible ambient temperature stated in the general technical data.
amb
Keep to the lower of the two values.
= 15 V , Ii = 25 mA , Pi = 34 mW ,
at U
i
T6 : 55 °C (131 °F)
T5 : 70 °C (158 °F)
T4 : 95 °C (203 °F)
T3 : 95 °C (203 °F)
T2 : 95 °C (203 °F)
T1 : 95 °C (203 °F)
at U
= 15 V , Ii = 25 mA , Pi = 64 mW ,
i
T6 : 55 °C (131 °F)
T5 : 70 °C (158 °F)
T4 : 95 °C (203 °F)
T3 : 95 °C (203 °F)
T2 : 95 °C (203 °F)
T1 : 95 °C (203 °F)
at U
= 15 V , Ii = 52 mA , Pi = 169 mW ,
i
T6 : 50 °C (122 °F)
T5 : 60 °C (140 °F)
T4 : 90 °C (194 °F)
T3 : 90 °C (194 °F)
T2 : 90 °C (194 °F)
T1 : 90 °C (194 °F)
at Ui = 15 V , Ii = 25 mA , Pi = 34 mW ,
T6 : 75 °C (167 °F)
T5 : 90 °C (194 °F)
T4 : 100 °C (212 °F)
T3 : 100 °C (212 °F)
T2 : 100 °C (212 °F)
T1 : 100 °C (212 °F)
at U
= 15 V , Ii = 25 mA , Pi = 64 mW ,
i
T6 : 75 °C (167 °F)
T5 : 90 °C (194 °F)
T4 : 100 °C (212 °F)
T3 : 100 °C (212 °F)
T2 : 100 °C (212 °F)
T1 : 100 °C (212 °F)
at U
= 15 V , Ii = 52 mA , Pi = 169 mW ,
i
T6 : 65 °C (149 °F)
T5 : 80 °C (176 °F)
T4 : 90 °C (194 °F)
T3 : 90 °C (194 °F)
T2 : 90 °C (194 °F)
T1 : 90 °C (194 °F)
Release date: 2018-04-19 08:15 Date of issue: 2018-04-19 223955_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
3
Page 4
Inductive sensorNCN3-F31-N4-K-10M
Equipment protection level Gb
Type of protection intrinsic safety
CE marking 0102
NCN3-F31-N4...
TÜV 99 ATEX 1479 X
¬ II 1G Ex ia IIC T6…T1 Ga
EN 60079-0:2012+A11:2013 , EN 60079-11:2012
IECEx TUN 17.0021X
Ex ia IIC T6...T1 Ga
IEC 60079-0:2011 , IEC 60079-11:2011
≤ 100 nF
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
≤ 100 µH
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Also observe the maximum permissible ambient temperature stated in the general technical data.
amb
Keep to the lower of the two values.
at U
= 15 V , Ii = 25 mA , Pi = 34 mW ,
i
T6 : 75 °C (167 °F)
T5 : 90 °C (194 °F)
T4 : 100 °C (212 °F)
T3 : 100 °C (212 °F)
T2 : 100 °C (212 °F)
T1 : 100 °C (212 °F)
at U
= 15 V , Ii = 25 mA , Pi = 64 mW ,
i
T6 : 75 °C (167 °F)
T5 : 90 °C (194 °F)
T4 : 100 °C (212 °F)
T3 : 100 °C (212 °F)
T2 : 100 °C (212 °F)
T1 : 100 °C (212 °F)
at U
= 15 V , Ii = 52 mA , Pi = 169 mW ,
i
T6 : 65 °C (149 °F)
T5 : 80 °C (176 °F)
T4 : 90 °C (194 °F)
T3 : 90 °C (194 °F)
T2 : 90 °C (194 °F)
T1 : 90 °C (194 °F)
Certificates
ATEX certificate
ATEX marking
Standards
Effective internal inductivity C
Effective internal inductance L
Maximum permissible ambient temperature T
i
i
amb
PF13CERT2895 X
¬ II 3G Ex ic IIC T6…T1 Gc
EN 60079-0:2012+A11:2013 , EN 60079-11:2012
≤ 100 nF
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
≤ 100 µH
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Also observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at U
= 20 V , Ii = 25 mA , Pi = 34 mW ,
i
T6 : 75 °C (167 °F)
T5 : 90 °C (194 °F)
T4 : 100 °C (212 °F)
T3 : 100 °C (212 °F)
T2 : 100 °C (212 °F)
T1 : 100 °C (212 °F)
at U
= 20 V , Ii = 25 mA , Pi = 64 mW ,
i
T6 : 75 °C (167 °F)
T5 : 90 °C (194 °F)
T4 : 100 °C (212 °F)
T3 : 100 °C (212 °F)
T2 : 100 °C (212 °F)
T1 : 100 °C (212 °F)
at U
= 20 V , Ii = 52 mA , Pi = 169 mW ,
i
T6 : 65 °C (149 °F)
T5 : 80 °C (176 °F)
T4 : 90 °C (194 °F)
T3 : 90 °C (194 °F)
T2 : 90 °C (194 °F)
T1 : 90 °C (194 °F)
Release date: 2018-04-19 08:15 Date of issue: 2018-04-19 223955_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
4
Page 5
Inductive sensorNCN3-F31-N4-K-10M
Equipment protection level Da
Type of protection intrinsic safety
CE marking 0102
Type of protection intrinsic safety
CE marking 0102
Certificates
Appropriate type
IECEx certificate
IECEx marking
Standards
Effective internal inductivity C
Effective internal inductance L
i
i
Maximum permissible ambient temperature T
NCN3-F31-N4-K...
TÜV 99 ATEX 1479 X
¬ II 1D Ex ia IIIC T135°C Da
EN 60079-0:2012+A11:2013 , EN 60079-11:2012
IECEx TUN 17.0021X
Ex ia IIIC T135°C Da
IEC 60079-0:2011 , IEC 60079-11:2011
≤ 100 nF
A cable length of 10 m is considered.
≤ 100 µH
A cable length of 10 m is considered.
Also observe the maximum permissible ambient temperature stated in the general technical data.
amb
Keep to the lower of the two values.
at U
= 15 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F)
i
at U
= 15 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F)
i
at U
= 15 V , Ii = 52 mA , Pi = 169 mW : 90 °C (194 °F)
i
NCN3-F31-N4...
IECEx TUN 17.0021X
Ex ia I Mb
IEC 60079-0:2011 , IEC 60079-11:2011
≤ 100 nF
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
≤ 100 µH
The value is applicable for one sensor circuit.
A cable length of 10 m is considered.
Also observe the maximum permissible ambient temperature stated in the general technical data.
amb
Keep to the lower of the two values.
at U
= 15 V , Ii = 25 mA , Pi = 34 mW : 100 °C (212 °F)
i
at U
= 15 V , Ii = 25 mA , Pi = 64 mW : 100 °C (212 °F)
i
at U
= 15 V , Ii = 52 mA , Pi = 169 mW : 90 °C (194 °F)
i
Release date: 2018-04-19 08:15 Date of issue: 2018-04-19 223955_eng.xml
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
5
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.