Datasheet HTB 50-P, HTB 50-TP1, HTB 100-P, HTB 100-TP1, HTB 200-P Datasheet (LEM)

...
Page 1
查询HTB100-TP供应商
Current Transducers HTB 50 .. 400-P and HTB 50 .. 100-TP
For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit).
Electrical data
Primary nominal Primary current Type r.m.s. current measuring range I
(A) IP (A)
PN
200 ±500 HTB 200-P 300 ±600 HTB 300-P 400 ±600 HTB 400-P
V
C
I
C
V
d
R
IS
V
OUT
R
OUT
R
L
Supply voltage (±5 %) Current consumption <±15 mA R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn 2.5 kV Isolation resistance @ 500 VDC >500 M Output voltage @ ± IPN, RL = 10 kΩ, TA = 25°C ±4 V Output internal resistance 100 Load resistance ≥10 kΩ
2)
±12 .. ±15 V
I
= 50 .. 400 A
PN
1)
1)
Features
Hall effect measuring principle
Galvanic isolation between primary
and secondary circuit
Isolation voltage 2500V
Low power consumption
Wide power supply: ±12V to ±15V
Primary bus bar option for 50A and
100A version for ease of connection
Accuracy - Dynamic performance data
X Accuracy @ IPN, TA = 25°C (without offset) <±1 % of I
εε
L
V
OE
V
OH
V
OT
Linearity (0 .. ± IPN) <±1 % of I Electrical offset voltage, TA = 25°C <±30 mV Hysteresis offset voltage @ IP = 0; after an excursion of 3 x I Thermal drift of V
OE
PN
HTB 50-(T)P <±2.0 mV/K
<±1 % of I
HTB 100-(T)P..400-P <±1.0 mV/K
TCεε
G
t
r
f Frequency bandwidth (-3 dB)
Thermal drift (% of reading) <±0.1 %/K Response time @ 90% of I
P
3)
<3 µs DC .. 50 kHz
General data
T
A
T
S
m Mass (-TP version) <30 (<36) g
Notes : EN 50178 approval pending
1)
-TP version is equipped with a primary bus bar.
2)
Operating at ±12V ≤ Vc < ±15V will reduce measuring range.
3)
Derating is needed to avoid excessive core heating at high frequency.
Ambient operating temperature -20 .. +80 °C Ambient storage temperature -25 .. +85 °C
2 pins of Ø2mm diameter are available on transducer for PCB soldering.
Advantages
PN
Small size and space saving
PN
Only one design for wide current
ratings range
PN
High immunity to external
interference.
Applications
AC variable speed drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
030529/7
LEM Components www.lem.com
Page 2
HTB 50 .. 400-P Back view
4-0.635x0.635
Bottom view
HTB 50 .. 100-TP
Back view
34
6 +/-1
1.5
4321
3-P=2.5
10 19
24.5
5.5
39
39
d16
19.5
3.5
2-d2
Mounting Pins
11
7
3
3
Left view
Positive Current Flow
14 MAX.
9 +/-1
Secondary Pin Identification
1 +Vc 2 -Vc 3 Output 4 0V
Left view
14 MAX.
Bottom view
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
34
4-0.635x0.635
14
2
1.5
3-P=2.5
6.5
4
321
10.5
3.25
10
17
1.5
1.5
3
3
6-1.5x1.5
3
3
3.5
11
3.5
1.5
Positive Current Flow
Secondary Pin Identification
1 +Vc 2 -Vc 3 Output 4 0V
Loading...