查询HTB100-TP供应商
Current Transducers HTB 50 .. 400-P
and HTB 50 .. 100-TP
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
Primary nominal Primary current Type
r.m.s. current measuring range
I
(A) IP (A)
PN
50 ±150 HTB 50-P, HTB 50-TP
100 ±300 HTB 100-P, HTB 100-TP
200 ±500 HTB 200-P
300 ±600 HTB 300-P
400 ±600 HTB 400-P
V
C
I
C
V
d
R
IS
V
OUT
R
OUT
R
L
Supply voltage (±5 %)
Current consumption <±15 mA
R.m.s. voltage for AC isolation test, 50/60 Hz, 1 mn 2.5 kV
Isolation resistance @ 500 VDC >500 MΩ
Output voltage @ ± IPN, RL = 10 kΩ, TA = 25°C ±4 V
Output internal resistance 100 Ω
Load resistance ≥10 kΩ
2)
±12 .. ±15 V
I
= 50 .. 400 A
PN
1)
1)
Features
• Hall effect measuring principle
• Galvanic isolation between primary
and secondary circuit
• Isolation voltage 2500V
• Low power consumption
• Wide power supply: ±12V to ±15V
• Primary bus bar option for 50A and
100A version for ease of connection
Accuracy - Dynamic performance data
X Accuracy @ IPN, TA = 25°C (without offset) <±1 % of I
εε
L
V
OE
V
OH
V
OT
Linearity (0 .. ± IPN) <±1 % of I
Electrical offset voltage, TA = 25°C <±30 mV
Hysteresis offset voltage @ IP = 0;
after an excursion of 3 x I
Thermal drift of V
OE
PN
HTB 50-(T)P <±2.0 mV/K
<±1 % of I
HTB 100-(T)P..400-P <±1.0 mV/K
TCεε
G
t
r
f Frequency bandwidth (-3 dB)
Thermal drift (% of reading) <±0.1 %/K
Response time @ 90% of I
P
3)
<3 µs
DC .. 50 kHz
General data
T
A
T
S
m Mass (-TP version) <30 (<36) g
Notes : EN 50178 approval pending
1)
-TP version is equipped with a primary bus bar.
2)
Operating at ±12V ≤ Vc < ±15V will reduce measuring range.
3)
Derating is needed to avoid excessive core heating at high frequency.
Ambient operating temperature -20 .. +80 °C
Ambient storage temperature -25 .. +85 °C
2 pins of Ø2mm diameter are available on transducer
for PCB soldering.
Advantages
PN
• Small size and space saving
PN
• Only one design for wide current
ratings range
PN
• High immunity to external
interference.
Applications
• AC variable speed drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
030529/7
LEM Components www.lem.com

HTB 50 .. 400-P
Back view
4-0.635x0.635
Bottom view
HTB 50 .. 100-TP
Back view
34
6 +/-1
1.5
4321
3-P=2.5
10 19
24.5
5.5
39
39
d16
19.5
3.5
2-d2
Mounting Pins
11
7
3
3
Left view
Positive Current Flow
14 MAX.
9 +/-1
Secondary Pin Identification
1 +Vc
2 -Vc
3 Output
4 0V
Left view
14 MAX.
Bottom view
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
34
4-0.635x0.635
14
2
1.5
3-P=2.5
6.5
4
321
10.5
3.25
10
17
1.5
1.5
3
3
6-1.5x1.5
3
3
3.5
11
3.5
1.5
Positive Current Flow
Secondary Pin Identification
1 +Vc
2 -Vc
3 Output