The HPR4XX Series uses advanced circuit
design and packaging technology to realize
superior reliability and performance. A
170kHz push-pull oscillator is used in the
input stage. The HPR4XX Series reduces
beat-frequency oscillation problems when
used with high frequency isolation amplifiers.
Reduced parts count and high efficiency add to
the reliability of the HPR4XX Series.
SPECIFICATIONS All specifications are typical at T
The high efficiency of the HPR4XX Series
means less internal power dissipation, as low
as 190mW. With less heat to dissipate the
HPR4XX Series can operate at higher
temperatures with no degradation of reliable
operation. In addition, the high efficiency of
the HPR4XX Series means the series is able
to offer greater than 10 W/inch3 of output
power density. Operation down to no load
= +25°C nominal input voltage unless otherwise specified.
A
will not impact the reliability of the series,
although this product has a >1mA minimum
load for specifications purposes.
The HPR4XX Series provides high
isolation in a very small package. The use of
surface mounted devices and manufacturing
technologies makes it possible to offer
premium performance and low cost.
Specifications are at TA = +25°C nominal input voltage unless otherwise specified.
PARAMETERCONDITIONSMINTYPMAXUNITS
INPUT
Voltage Range4.555.5VDC
10.81213.2VDC
13.51516.5VDC
21.62426.4VDC
OUTPUT
Rated Power 750mW
Voltage Setpoint AccuracyRated Load, Nominal V
IN
Ripple & NoiseBW = DC to 10MHz45mVp-p
BW =10Hz to 2MHz30mVrms
HPR403BW = DC to 10MHz90mVp-p
Voltage (Over Input Voltage Range)1mA Load, V
1mA Load, V
1mA Load, V
= 5V 7VDC
OUT
= 12V15VDC
OUT
= 15V18VDC
OUT
Temperature Coefficent .01%/°C
REGULATION
Line RegulationHigh Line to Low Line 1%/%Vin
Load Regulation (5V out only)Rated Load to 1mA Load10%
Load Regulation (All other modes)Rated Load to 1mA Load 3%
Switching Frequency 170kHz
Frequency ChangeOver Line and Load 24%
Package Weight 2g
MTTF per MIL-HDBK-217, Rev. E*Circuit Stress Method
Ground BenignTA = +25°C7.9MH r
Lead Temperature (soldering, 10 seconds max .+300°C *
* NOTE: Refer to Reflow Profile for SMD Models.
Product: www.cdpoweronline.com
HPR4XX REV G 1/03
ORDERING INFORMATION
HPR 4XX
Device Family
HPR Indicates DC/DC Converter
Model Number
Selected from Table of Electrical Characteristics
2
Page 3
TYPICAL PERFORMANCE CURVES
Specifications are at TA = +25°C nominal input voltage, nominal load, recommended external components applied, unless
otherwise specified. (Refer to Application Note DCAN-9 at www.cdpowerelectronics.com)
VOUT VS LOAD
(5Vout Models)
5.7
5.5
5.3
Vout
5.1
4.9
040120160
80
Output Current (mA)Output Current each load (mA)Output Current each load (mA)
5.4
5.2
5.0
VoutFrequency (KHz)
4.8
4.6
020406080
VOUT VS LOAD
(±5Vout Models)
VOUT VS LOAD
12.5
(12Vout Models)
12.4
12.3
12.2
Vout
12.1
12.0
11.9
020406080
VOUT VS LOAD
12.6
(±12Vout Models)
12.5
12.4
12.3
Vout
12.2
12.1
12.0
010203040
Output Current each load (mA)
EFFICIENCY VS LOAD
90
75
60
45
30
Efficiency (%)
15
0
20
0
60
4080
% of Rated Load (%)
100
VOUT VS LOAD
(15Vout Models)
15.9
15.7
15.5
Vout
15.3
Vout
15.1
14.9
0204060800
Output Current each load (mA)Output Power each load (Watts)
OSCILLATION FREQUENCY VS
TEMPERATURE
220
200
180
160
140
-300306090
Temperature (°C)
16.5
16.0
15.5
15.0
14.5
14.0
13.5
VOUT VS LOAD
(±15Vout Models)
0.2
0.40.60.81.0
LOAD CAPACITANCE vs INPUT RISE TIME
600
500
400
300
200
Total Load Capacitance (uF)
100
0
0 5 10 15 20 25 30 35 40 45 50
90
80
70
60
50
40
30
20
Total Load Capacitance (uF)
10
0
0 5 10 15 20 25 30 35 40 45 50
(5 Vout models)
Rise Time of Input Voltage (mS)
LOAD CAPACITANCE vs INPUT RISE TIME
(12 Vout models)
Rise Time of Input Voltage (mS)
Product: www.cdpoweronline.com
SAFE OPERATING AREA
SAFE OPERATING AREA
SAFE OPERATING AREA
NOTES:
1.) When operated within the SAFE OPERATING AREA as defined
2.) For dual output models, total load capacitance is the sum of the
HPR4XX REV G 1/03
LOAD CAPACITANCE vs INPUT RISE TIME
60
50
40
30
20
Total Load Capacitance (uF)
10
0
0 5 10 15 20 25 30 35 40 45 50
(15 Vout models)
SAFE OPERATING AREA
Rise Time of Input Voltage (mS)
by the above curves, the output voltage of HPR4XX devices is
guaranteed to be within 95% of its steady-state value within 100
milliseconds after the input voltage has reached 95% of its steadystate value.
capacitances on the plus and minus outputs.
3
Page 4
MECHANICAL
FRONT
VIEW
BOTTOM
VIEW
0.77±0.010"
(19.56±0.25)
1
2
0.02±0.002"
(0.51±0.05)
765
0.18±0.015"
(4.57±0.38)
0.400±0.010"
(10.16±0.25)
0.140"
MIN
(3.56)
0.240±0.010"
(6.09±0.25)
0.020±0.010"
(0.51±0.25)
PIN CONNECTIONS
1.+VIN
2.-VIN
5.-VOUT
6.COM*
7.+VOUT
*Common pin not present on
single output models.
RIGHT
SIDE
VIEW
0.010±0.002"
(0.25±0.05)
0.035±0.015"
(0.89±0.38)
Notes:
All dimensions are in inches (millimeters).
GRID: 0.100 inches (2.54 millimeters)
PIN PLACEMENT TOLERANCE: ± 0.015"
Power Electronics Division, Americas
3400 E Britannia Drive, Tucson, Arizona 85706
Tel: 800.547.2537 Fax: 520.295.4197
Any data, prices, descriptions or specifications presented herein are subject to revision by C&D Technologies, Inc. without notice. While such information is believed to
be accurate as indicated herein, C&D Technologies, Inc. makes no warranty and hereby disclaims all warranties, express or implied, with regard to the accuracy or
completeness of such information. Further, because the product(s) featured herein may be used under conditions beyond its control, C&D Technologies, Inc. hereby
disclaims all warranties, either express or implied, concerning the fitness or suitability of such product(s) for any particular use or in any specific application or arising
from any course of dealing or usage of trade. The user is solely responsible for determining the suitability of the product(s) featured herein for user’s intended purpose
and in user’s specific application. C&D Technologies, Inc. does not warrant or recommend that any of its products be used in any life support or aviation or aerospace
applications.
Product: www.cdpoweronline.com
HPR4XX REV G 1/03
T el: +44 (0)1908 615232 Fax: +44 (0)1908 617545