• Reduced power consumption with voltage holding and pulse width
modulation (PWM) control (Only for G5Q-
■Model Number Legend■Application Examples
@-PW model)
• Ideal for output applications of control equipment.
G
5
Q
1
Page 2
G5QPCB Power Relay
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G5Q-1A DC5
Rated coil voltage
■Ordering Information
Terminal ShapeMarket CodeClassificationContact FormEnclosure RatingModelRated Coil Voltage Minimum Packing Unit
G5Q-1A
Flux protection
G5Q-1A-PW
G5Q-1
G5Q-1-PW
G5Q-1A-HA5VDC
G5Q-1A-HA-PW
G5Q-1-HA
G5Q-1-HA-PW
G
5
Q
PCB terminals
General purpose
Home Appliance
SPST-NO(1a)
SealedG5Q-1A4
Standard
Flux protection
SPDT(1c)
SealedG5Q-14
High-capacity
SPST-NO(1a)
SPDT(1c)
Standard
SPST-NO(1a)
High-capacityG5Q-1A-EU-HA
Standard
SPDT(1c)
High-capacityG5Q-1-EU-HA
Flux protectionG5Q-1A-EU
SealedG5Q-1A4-EU
Flux protectionG5Q-1-EU
SealedG5Q-14-EU
Flux protection
5VDC
9VDC
12VDC
24VDC
5VDC
12VDC
24VDC
5VDC
9VDC
12VDC
24VDC
5VDC
9VDC
12VDC
24VDC
5VDC
12VDC
24VDC
5VDC
9VDC
12VDC
24VDC
5VDC
12VDC
24VDC
12VDC
24VDC
12VDC
24VDC
5VDC
12VDC
24VDC
12VDC
24VDC
100 pcs/tray
Note 2. Contact your OMRON sales representative for tube packing models (40 pcs/tube).
■Ratings
●Coil
Contact formRated voltage
5 VDC40125
SPST-NO (1a)
SPDT (1c)
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
* Power consumption with holding voltage are Approx. 32 mW for 1a and Approx. 36 mW for 1c. Please confirm the detail on page 6 Coil Voltage Reduction (holding voltage).
Rated carry current10 A (NO)/3 A (NC)
Max. switching voltage 277 VAC, 30 VDC
Max. switching current
LoadResistive load
StandardHigh-capacityStandardHigh-capacity
10 A at 125 VAC (NO)
10 A at 125 VAC
3 A at 125 VAC
5 A at 250 VAC
3 A at 250 VAC
5 A at 30 VDC
AC: 10 A (NO)/3 A (NC)
DC: 5 A (NO)/3 A (NC)
10 A at 250 VAC
3 A at 125 VAC
5 A at 250 VAC
3 A at 250 VAC
5 A at 30 VDC
3 A at 125 VAC (NO)
5 A at 250 VAC (NO)
3 A at 250 VAC (NO)
5 A at 30 VDC (NO)
3 A at 125 VAC (NC)
3 A at 250 VAC (NC)
3 A at 30 VDC (NC)
Must release
voltage
(V)
5% min.
5 to 34%*
5% min.
5 to 25%*
10 A at 250 VAC (NO)
3 A at 125 VAC (NO)
5 A at 250 VAC (NO)
3 A at 250 VAC (NO)
5 A at 30 VDC (NO)
3 A at 125 VAC (NC)
3 A at 250 VAC (NC)
3 A at 30 VDC (NC)
Max. voltage
(V)
190%
(at 23°C)
Power
consumption
(mW)
Approx. 200
Approx. 32*
Approx. 400
Approx. 36*
2
Page 3
G5QPCB Power Relay
■Characteristics
ItemClassificationStandard model
Contact resistance *1100 mΩ max.
Operate time10 ms max.
Release time5 ms max.
Insulation resistance *21,000 MΩ min.
Dielectric
strength
Impulse withstand voltage
(between coil and contacts)
Vibration
resistance
Shock
resistance
Durability
Failure rate (P level) (reference *3)10 mA at 5 VDC
Ambient operating temperature
Ambient operating humidity5% to 85%
WeightApprox. 6.5 g
Note. Note. Values in the above table are the initial values at 23°C.
*1. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
*2. Testing conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured.
*3. This value was measured at a switching frequency of 120 operations/min.
Between coil and contacts 4,000 VAC, 50/60 Hz for 1 min
Between contacts of the
same polarity
Destruction10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Destruction1,000 m/s
Malfunction100 m/s
Mechanical10,000,000 operations (18,000 operations per hour)
Electrical
1,000 VAC, 50/60 Hz for 1 min
8 kV (1.2 x 50 μs)
2
2
•NO
25,000 operations: 10 A at 250 VAC resistive load
(operation: ON for 1 sec, OFF for 3 sec) <High-capacity type>
50,000 operations: 10 A at 125 VAC resistive load
(operation: ON for 1 sec, OFF for 3 sec)
200,000 operations: 3 A at 125 VAC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
50,000 operations: 5 A at 250 VAC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
100,000 operations: 3 A at 250 VAC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
100,000 operations: 5 A at 30 VDC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
•NC
200,000 operations: 3 A at 125 VAC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
100,000 operations: 3 A at 250 VAC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
100,000 operations: 3 A at 30 VDC resistive load
(operation: ON for 1 sec, OFF for 1 sec)
-40°C to 105°C (with no icing or condensation)
-40°C to 85°C (with no icing or condensation) <High-capacity type>
G
5
Q
3
Page 4
G5QPCB Power Relay
100
1
1101001000
Switching current (A)
Switching voltgate (V)
AC resistive load (NO)
AC resistive load (NC)
DC resistive load (NO)
DC resistive load (NC)
10
100
1
1101001000
Switching current (A)
Switching voltgate (V)
AC resistive load (NO)
AC resistive load (NC)
DC resistive load (NO)
DC resistive load (NC)
10
Standard
High-capacity(-EU)
Note. The Maximum coil voltage refers to the
maximum value in a varying range of operating
power voltage, not a continuous voltage.
Y
1
1
t
Sample: G5Q-14 12 VDC
Number of Relays: 5 pcs
Test conditions: Shock is applied
in ±X, ±Y, and ±Z directions three
times each with and without
energizing the Relays to check
the number of malfunctions.
The energized voltage is 100% of
the rated voltage.
Requirement: None malfuction
100 m/s
2
7.62±0.1
Terminal Arrangement/
Internal Connections
(Bottom View)
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
15.8MAX
(15.5)*
20.3MAX
(20.0)*
0.4
3.4
7.6210.16
10.3MAX
(10.0)*
7.62
1
(1.19)
(1.18)
7.62±0.1
10.16±0.1
4-1.3 ±0.1 dia.
123
5
0.27
MAX
(No coil polarity)
* Average value
0.4 x 0.4
G5Q-1A(4)(-EU)(-HA)(-PW)
G5Q-1(4)(-EU)(-HA)(-PW)
■Engineering Data
●Maximum Switching Capacity●Ambient Temperature VS.
Maximum Coil Voltage
Standard
200
180
160
140
120
100
80
Maximum coil voltage (% of rated)
60
40
20
0
-40
-20
200
High-capacity(-EU)
200
180
G
5
Q
160
140
120
100
Maximum coil voltage (% of rated)
80
60
40
20
0
-40
-20
200
802360
10040120
Ambient temperature (°C)
Ambient temperature (°C)
105
80236010040120
85
●Shock Malfunction
1,000
X
,000
Y'
300
1,000
,000
Z'
NC
300
Contact
Unit: m/s
Shock direction
XX'
Y
Y'
Z
1,000
NO Contac
1,000
X'
2
Z
Z'
■Dimensions(Unit: mm)
15.8MAX
(15.5)*
4
0.4
3.4
0.4 x 0.4
20.3MAX
(20.0)*
0.27
MAX
5.0810.16
2.54
10.3MAX
1
(10.0)*
7.62
(1.19)
* Average value
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
(1.18)
7.62±0.1
10.16±0.1
5-1.3 ±0.1 dia.
2.54±0.1
5.08±0.1
Terminal Arrangement/
Internal Connections
(Bottom View)
123
45
(No coil polarity)
Page 5
G5QPCB Power Relay
■Approved Standards
UL Recognized: (File No. E41515)
CSA Certified: (File No. LR31928)
ModelContact formCoil ratingsContact ratings
G5Q-1A(4)(-EU)(-HA)(-PW)
G5Q-1(4)(-EU)(-HA)(-PW)
SPST-NO (1a)
SPDT (1c)
5 to 48 VDC
EN/IEC, VDE (Certified/No.40009467)
ModelContact formCoil ratingsContact ratings
G5Q-1(4)(-HA)(-PW)
G5Q-1A(4)(-HA)(-PW)
SPST-NO (1a)
G5Q-1A(4)-EU(-HA)
G5Q-1(4)-EU(-HA)
SPDT (1c)
5 to 48 VDC
10 A 250 VAC N.O. only (Resistive) 40°C
10 A 30 VDC N.O. only (Resistive) 40°C
4 A 120 VAC N.O. only (Resistive) 40°C100,000
3 A 250 VAC N.C. only (Resistive) 40°C
3 A 30 VDC N.C. only (Resistive) 40°C
10 A making and 0 A breaking, 250 VAC (cosφ=1) 105°C
5 A marking and 3 A breaking, 30 VDC (0 ms) 105°C
5 A 250 VAC (cosφ=1) (N.O.) 105°C75,000
10 A 250 VAC (cosφ=1) (N.O.) 65°C
5 A 30 VDC (0 ms) (N.O.) 65°C
3 A 30 VDC (0 ms) (N.C.) 65°C
4 A 250 VAC (cosφ=1) (N.O.) 85°C100,000
Number of test
operations
6,000
6,000
Number of test
operations
10,000
10,000
Creepage Distance6.4 mm min.
Clearance Distance5.5 mm min.
Insulation Material GroupIIIa
Type of Insulation Coil-contact Circuit
Open Contact Circuit
Rated Insulation Voltage250 V
Pollution Degree2
Rated Voltage System250 V / 400 V (EU flux type only)
Over Voltage CategoryIII
Category of Protection according to IEC 61810-1 RT II (Flux protection) / RT III (Sealed)
Glow Wire according to IEC 60335-1
Tracking Index of Relay BasePTI 250 V min. (housing parts)
Flammability Class according to UL94V-0
Coil Insulation SystemF Class (UL 1446)
Basic (Rated voltage 400 V) / Reinforced (Rated voltage 250 V)
Micro disconnection
<HA Models only>
GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12)
G
5
Q
5
Page 6
G5QPCB Power Relay
40%
(Holding voltage)
100%
(Rated voltage)
100ms min.
30%
(Holding voltage)
100%
(Rated voltage)
100ms min.
G5Q-1A
G5Q-1
Applied coil voltage (100%)
Surge
absorption
diode
Relay
Coil
Pulse input
MOS-FET
• Applied voltage: rated voltage
• Duty: 50% or more
• Frequency: 10 kHz or more
• Diode Vf: 0.4 V or less
Please check each region's Terms & Conditions by region website.