Datasheet G5Q-14 DC24 Specification

Page 1
G5Q
G5Q-@@@-@ -@ -@
——— — — —
123 4 5 6
1. Number of Poles
1 : 1-pole
2. Contact Form
None : SPDT (1c)
A : SPST-NO (1a)
3. Enclosure Rating
None : Flux protection
4: Sealed
4. Classification
None : Standard
EU : High-capacity
5. Market Code
None : General purpose
HA : Home Appliance according to
IEC/EN60335-1
6. Special Requirement
None : Not supported PW : Supported
PCB Power Relay
A Miniature Power Relay with 1-pole 10A Switching Capacity
• Excellent switching performance for a variety of loads.
and contacts).
• Low coil power consumption (SPST-NO: 200 mW, SPDT: 400 mW)
• Coil insulation system: Class F (UL1446).
• IEC/EN 60335-1 conformed. (-HA Model)
• Reduced power consumption with voltage holding and pulse width
modulation (PWM) control (Only for G5Q-
Model Number Legend Application Examples
@-PW model)
• Ideal for output applications of control equipment.
G
5
Q
1
Page 2
G5Q PCB Power Relay
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G5Q-1A DC5
Rated coil voltage
Ordering Information
Terminal Shape Market Code Classification Contact Form Enclosure Rating Model Rated Coil Voltage Minimum Packing Unit
G5Q-1A
Flux protection
G5Q-1A-PW
G5Q-1
G5Q-1-PW
G5Q-1A-HA 5VDC
G5Q-1A-HA-PW
G5Q-1-HA
G5Q-1-HA-PW
G
5
Q
PCB terminals
General purpose
Home Appliance
SPST-NO(1a)
Sealed G5Q-1A4
Standard
Flux protection
SPDT(1c)
Sealed G5Q-14
High-capacity
SPST-NO(1a)
SPDT(1c)
Standard
SPST-NO(1a)
High-capacity G5Q-1A-EU-HA
Standard
SPDT(1c)
High-capacity G5Q-1-EU-HA
Flux protection G5Q-1A-EU
Sealed G5Q-1A4-EU
Flux protection G5Q-1-EU
Sealed G5Q-14-EU
Flux protection
5VDC
9VDC 12VDC 24VDC
5VDC 12VDC 24VDC
5VDC
9VDC 12VDC 24VDC
5VDC
9VDC 12VDC 24VDC
5VDC 12VDC 24VDC
5VDC
9VDC 12VDC 24VDC
5VDC 12VDC 24VDC
12VDC 24VDC
12VDC 24VDC
5VDC 12VDC 24VDC 12VDC 24VDC
100 pcs/tray
Note 2. Contact your OMRON sales representative for tube packing models (40 pcs/tube).
Ratings
Coil
Contact form Rated voltage
5 VDC 40 125
SPST-NO (1a)
SPDT (1c)
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. Note 2. The operating characteristics are measured at a coil temperature of 23°C. Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil. * Power consumption with holding voltage are Approx. 32 mW for 1a and Approx. 36 mW for 1c. Please confirm the detail on page 6 Coil Voltage Reduction (holding voltage).
9 VDC 22.2 405 12 VDC 16.7 720 24 VDC 8.3 2880
5 VDC 80 63
9 VDC 44.4 202 12 VDC 33.3 360 24 VDC 16.7 1440
Rated current
(mA)
Coil resistance
(Ω)
Must operate
voltage
(V)
75% max.
Contacts
Item SPST-NO (1a) SPDT (1c)
Contact type Single Contact material Ag-Alloy (Cd free)
Rated load (resistive)
Rated carry current 10 A (NO)/3 A (NC) Max. switching voltage 277 VAC, 30 VDC
Max. switching current
Load Resistive load
Standard High-capacity Standard High-capacity
10 A at 125 VAC (NO)
10 A at 125 VAC 3 A at 125 VAC 5 A at 250 VAC 3 A at 250 VAC 5 A at 30 VDC
AC: 10 A (NO)/3 A (NC) DC: 5 A (NO)/3 A (NC)
10 A at 250 VAC 3 A at 125 VAC 5 A at 250 VAC 3 A at 250 VAC 5 A at 30 VDC
3 A at 125 VAC (NO) 5 A at 250 VAC (NO) 3 A at 250 VAC (NO) 5 A at 30 VDC (NO) 3 A at 125 VAC (NC) 3 A at 250 VAC (NC) 3 A at 30 VDC (NC)
Must release
voltage
(V)
5% min.
5 to 34%*
5% min.
5 to 25%*
10 A at 250 VAC (NO) 3 A at 125 VAC (NO) 5 A at 250 VAC (NO) 3 A at 250 VAC (NO) 5 A at 30 VDC (NO) 3 A at 125 VAC (NC) 3 A at 250 VAC (NC) 3 A at 30 VDC (NC)
Max. voltage
(V)
190%
(at 23°C)
Power
consumption
(mW)
Approx. 200 Approx. 32*
Approx. 400 Approx. 36*
2
Page 3
G5Q PCB Power Relay
Characteristics
Item Classification Standard model
Contact resistance *1 100 mΩ max.
Operate time 10 ms max.
Release time 5 ms max.
Insulation resistance *2 1,000 MΩ min.
Dielectric strength
Impulse withstand voltage (between coil and contacts)
Vibration resistance
Shock resistance
Durability
Failure rate (P level) (reference *3) 10 mA at 5 VDC
Ambient operating temperature
Ambient operating humidity 5% to 85%
Weight Approx. 6.5 g
Note. Note. Values in the above table are the initial values at 23°C. *1. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method. *2. Testing conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured. *3. This value was measured at a switching frequency of 120 operations/min.
Between coil and contacts 4,000 VAC, 50/60 Hz for 1 min
Between contacts of the same polarity
Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Destruction 1,000 m/s
Malfunction 100 m/s
Mechanical 10,000,000 operations (18,000 operations per hour)
Electrical
1,000 VAC, 50/60 Hz for 1 min
8 kV (1.2 x 50 μs)
2
2
•NO 25,000 operations: 10 A at 250 VAC resistive load (operation: ON for 1 sec, OFF for 3 sec) <High-capacity type> 50,000 operations: 10 A at 125 VAC resistive load (operation: ON for 1 sec, OFF for 3 sec) 200,000 operations: 3 A at 125 VAC resistive load (operation: ON for 1 sec, OFF for 1 sec) 50,000 operations: 5 A at 250 VAC resistive load (operation: ON for 1 sec, OFF for 1 sec) 100,000 operations: 3 A at 250 VAC resistive load (operation: ON for 1 sec, OFF for 1 sec) 100,000 operations: 5 A at 30 VDC resistive load (operation: ON for 1 sec, OFF for 1 sec)
•NC 200,000 operations: 3 A at 125 VAC resistive load (operation: ON for 1 sec, OFF for 1 sec) 100,000 operations: 3 A at 250 VAC resistive load (operation: ON for 1 sec, OFF for 1 sec) 100,000 operations: 3 A at 30 VDC resistive load (operation: ON for 1 sec, OFF for 1 sec)
-40°C to 105°C (with no icing or condensation)
-40°C to 85°C (with no icing or condensation) <High-capacity type>
G
5
Q
3
Page 4
G5Q PCB Power Relay
100
1
1 10 100 1000
Switching current (A)
Switching voltgate (V)
AC resistive load (NO)
AC resistive load (NC)
DC resistive load (NO)
DC resistive load (NC)
10
100
1
1 10 100 1000
Switching current (A)
Switching voltgate (V)
AC resistive load (NO)
AC resistive load (NC)
DC resistive load (NO)
DC resistive load (NC)
10
Standard
High-capacity(-EU)
Note. The Maximum coil voltage refers to the
maximum value in a varying range of operating power voltage, not a continuous voltage.
Y
1
1
t
Sample: G5Q-14 12 VDC Number of Relays: 5 pcs Test conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with and without energizing the Relays to check the number of malfunctions. The energized voltage is 100% of the rated voltage. Requirement: None malfuction 100 m/s
2
7.62±0.1
Terminal Arrangement/
Internal Connections
(Bottom View)
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
15.8MAX (15.5)*
20.3MAX (20.0)*
0.4
3.4
7.6210.16
10.3MAX (10.0)*
7.62
1
(1.19)
(1.18)
7.62±0.1
10.16±0.1
4-1.3 ±0.1 dia.
123
5
0.27
MAX
(No coil polarity)
* Average value
0.4 x 0.4
G5Q-1A(4)(-EU)(-HA)(-PW) G5Q-1(4)(-EU)(-HA)(-PW)
Engineering Data
Maximum Switching Capacity Ambient Temperature VS.
Maximum Coil Voltage
Standard
200
180
160
140
120
100
80
Maximum coil voltage (% of rated)
60
40
20
0
-40
-20
200
High-capacity(-EU)
200
180
G
5
Q
160
140
120
100
Maximum coil voltage (% of rated)
80
60
40
20
0
-40
-20
200
8023 60
10040 120
Ambient temperature (°C)
Ambient temperature (°C)
105
8023 60 10040 120
85
Shock Malfunction
1,000
X
,000
Y'
300
1,000
,000
Z'
NC
300
Contact
Unit: m/s
Shock direction
XX'
Y
Y'
Z
1,000
NO Contac
1,000
X'
2
Z Z'
Dimensions (Unit: mm)
15.8MAX (15.5)*
4
0.4
3.4
0.4 x 0.4
20.3MAX (20.0)*
0.27
MAX
5.0810.16
2.54
10.3MAX
1
(10.0)*
7.62
(1.19)
* Average value
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
(1.18)
7.62±0.1
10.16±0.1
5-1.3 ±0.1 dia.
2.54±0.1
5.08±0.1
Terminal Arrangement/
Internal Connections
(Bottom View)
123
45
(No coil polarity)
Page 5
G5Q PCB Power Relay
Approved Standards
UL Recognized: (File No. E41515)
CSA Certified: (File No. LR31928)
Model Contact form Coil ratings Contact ratings
G5Q-1A(4)(-EU)(-HA)(-PW) G5Q-1(4)(-EU)(-HA)(-PW)
SPST-NO (1a)
SPDT (1c)
5 to 48 VDC
EN/IEC, VDE (Certified/No.40009467)
Model Contact form Coil ratings Contact ratings
G5Q-1(4)(-HA)(-PW) G5Q-1A(4)(-HA)(-PW)
SPST-NO (1a)
G5Q-1A(4)-EU(-HA) G5Q-1(4)-EU(-HA)
SPDT (1c)
5 to 48 VDC
10 A 250 VAC N.O. only (Resistive) 40°C
10 A 30 VDC N.O. only (Resistive) 40°C
4 A 120 VAC N.O. only (Resistive) 40°C 100,000
3 A 250 VAC N.C. only (Resistive) 40°C
3 A 30 VDC N.C. only (Resistive) 40°C
10 A making and 0 A breaking, 250 VAC (cosφ=1) 105°C 5 A marking and 3 A breaking, 30 VDC (0 ms) 105°C
5 A 250 VAC (cosφ=1) (N.O.) 105°C 75,000
10 A 250 VAC (cosφ=1) (N.O.) 65°C 5 A 30 VDC (0 ms) (N.O.) 65°C 3 A 30 VDC (0 ms) (N.C.) 65°C
4 A 250 VAC (cosφ=1) (N.O.) 85°C 100,000
Number of test
operations
6,000
6,000
Number of test
operations
10,000
10,000
Creepage Distance 6.4 mm min.
Clearance Distance 5.5 mm min.
Insulation Material Group IIIa
Type of Insulation Coil-contact Circuit
Open Contact Circuit
Rated Insulation Voltage 250 V
Pollution Degree 2
Rated Voltage System 250 V / 400 V (EU flux type only)
Over Voltage Category III
Category of Protection according to IEC 61810-1 RT II (Flux protection) / RT III (Sealed)
Glow Wire according to IEC 60335-1
Tracking Index of Relay Base PTI 250 V min. (housing parts)
Flammability Class according to UL94 V-0
Coil Insulation System F Class (UL 1446)
Basic (Rated voltage 400 V) / Reinforced (Rated voltage 250 V) Micro disconnection
<HA Models only> GWT 750°C min. (IEC 60695-2-11) / GWFI 850°C min. (IEC 60695-2-12)
G
5
Q
5
Page 6
G5Q PCB Power Relay
40% (Holding voltage)
100% (Rated voltage)
100ms min.
30% (Holding voltage)
100% (Rated voltage)
100ms min.
G5Q-1A
G5Q-1
Applied coil voltage (100%)
Surge
absorption
diode
Relay Coil
Pulse input
MOS-FET
• Applied voltage: rated voltage
• Duty: 50% or more
• Frequency: 10 kHz or more
• Diode Vf: 0.4 V or less
Please check each region's Terms & Conditions by region website.
OMRON Corporation
Device & Module Solutions Company
Regional Contact
Cat. No. J155-E1-17
1122(0207)
Americas Europe
https://components.omron.com/us https://components.omron.com/eu
Asia-Pacific China
https://components.omron.com/ap https://components.omron.com.cn
Korea Japan
https://components.omron.com/kr https://components.omron.com/jp
In the interest of product improvement, specifications are subject to change without notice.
© OMRON Corporation 2007-2022 All Rights Reserved.
Precautions
Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
Coil Voltage Reduction (Holding Voltage) after Relay operation
• If the coil voltage is reduced to the holding voltage after relay
operation, first apply the rated voltage to the coil for at least
100 ms, as shown below.
• A voltage of at least 40% (G5Q-1A type) /30% (G5Q-1 type) of
the rated voltage is required for the coil holding voltage.
Do not allow voltage fluctuations to cause the coil holding volt-
age to fall below this level.
G
5
Q
Power consumption reduction of coil with pulse width modulation (PWM)
• Models with PWM drive capability (-PW) can reduce coil hold-
ing current with PWM control. This function reduces power
consumption by reducing the current held by coil.
• Apply the rated voltage for at least 100 ms at the time of relay
operation.
• The following are our verification conditions. When using, it be
sure to check the actual machine under the actual usage con-
ditions.
Example of drive circuit Conditions of validation carried out by OMRON
G5Q-1A
Applied
coil voltage
Rated voltage 100%
Holding voltage 40% Approx. 32 mW
* The coil resistance were measured at a coil temperature of 23°C with toler-
ances of ±10%.
Coil resistance*
125Ω (5 VDC)
720Ω (12 VDC)
2,880Ω (24 VDC)
Powe r
consumption
Approx. 200 mW
G5Q-1
Applied
coil voltage
Rated voltage 100%
Holding voltage 30% Approx. 36 mW
* The coil resistance were measured at a coil temperature of 23°C with toler-
ances of ±10%.
Coil resistance*
63Ω (5 VDC)
360Ω (12 VDC)
1,440Ω (24 VDC)
Powe r
consumption
Approx. 400 mW
6