Datasheet G5NB-1A4-12V, G5NB-1A4-5V, G5NB-1A4-24V Specification

Page 1
G5NB
G5NB-@@@-@
—— — —
123 4
1. Number of Poles
1: 1-pole
2. Contact Form
A: SPST-NO (1a)
3. Enclosure rating
None:Flux protection
4 : Fully sealed
4. Classification
None:Standard
E :High-capacity
Note. When ordering, add the rated coil voltage to the model number.
Example: G5NB-1A 5 VDC
Rated coil voltage
PCB Power Relay
A Miniature Relay with 1-pole 3A Switching Capability and 10 kV Impulse Withstand Voltage
• Highly efficient magnetic circuit for high sensitivity (200 mW).
• Small, yet provides 10-kV impulse withstand voltage (between coil
and contacts).
• Standard model conforms to UL/CSA/VDE standards.
• Satisfies EN61010 reinforced insulation requirements.
RoHS Compliant
Model Number Legend Application Examples
• Water heaters
• Refrigerators
• Air conditioners
• Home appliances
• Small electric appliances
G
5 N B
Ordering Information
Item
Classification
Standard
High-capacity
Contact
SPST-NO
Enclosure rating Model Rated coil voltage
form
Flux protection G5NB-1A
Fully sealed G5NB-1A4
(1a)
Flux protection G5NB-1A-E
Fully sealed G5NB-1A4-E
Ratings
Coil
Item
Rated current
Rated voltage % of rated voltage
5 VDC 40 125
12 VDC 16.7 720
18 VDC 11.1 1,620
24 VDC 8.3 2,880
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. Note 2. The operating characteristics are measured at a coil temperature of 23°C. Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
Contacts
Item Load
Contact Type Single
Contact material Ag-alloy (Cd free)
Rated load
Rated carry current 3 A 5 A
Max. switching voltage 250 VAC, 30 VDC
Max. switching current 3 A 5 A
(mA)
Standard High-capacity
3 A at 125 VAC 5 A at 250 VAC
3 A at 30 VDC 3 A at 30 VDC
Coil resistance
(Ω)
Minimum
packing unit
5, 12, 18, 24 VDC 100 pcs/Tray
Must operate voltage
(V)
75% max. 10% min.
Resistive load
Must release voltage
(V)
Max. voltage
(V)
180%
(at 23°C)
Power consumption
(mW)
Approx. 200
1
Page 2
G5NB PCB Power Relay
Switching voltage (V)
10
3
1
0.1 1 10 30 100 250 1,000
DC resistive load
AC resistive load
Contact resistance
Switching current (A)
Characteristics
Contact resistance *1 100 mΩ max. Operate time 10 ms max. Release time 10 ms max. Insulation resistance *2 1,000 MΩ min. (at 500 VDC)
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Durability
Failure rate (P level)
G
(reference value) *3
5
Ambient operating
N
temperature
B
Ambient operating humidity 5% to 85% Weight Approx. 4 g
Note. The data shown above are initial value. *1. Measurement conditions: 5 VDC, 1 A, voltage drop method *2. Measurement conditions: Measured at the same points as the dielectric
*3. This value was measured at a switching frequency of 120 operations/min.
Between coil and contacts
Between contacts of the same polarity
Between coil and contacts
Destruction
Malfunction
Destruction 1,000 m/s Malfunction 100 m/s Mechanical 5,000,000 operations min.
Electrical (resistive load)
strength using a 500 VDC ohmmeter.
4,000 VAC, 50/60 Hz for 1 min
750 VAC, 50/60 Hz for 1 min
10 kV (1.2 x 50 μs)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
2
Standard (G5NB-1A, -1A4)
200,000 operations at 125 VAC, 3A 200,000 operations at 30 VDC, 3A
High-capacity (G5NB-1A-E, -1A4-E)
100,000 operations at 250 VAC, 5A 200,000 operations at 30 VDC, 3A (with a rated load at 1,800 operations/hour)
DC5V 10mA
-40°C to 70°C (with no icing or condensation)
2
Actual Load Life (Reference Values)
1. 120 VAC motor and lamp load
2.5A surge and 0.5A normal:
250,000 operations min. (at 23°C)
2. 160 VDC valve load (with varistor)
0.24A:
250,000 operations min. (at 23°C)
Engineering Data
Maximum Switching Capacity
Standard models High-capacity models
Contact resistance
Switching current (A)
DC resistive load
AC resistive load
Contact voltage (V)
2
Page 3
G5NB PCB Power Relay
100
50
30
10
5
3
1
0 1 2 3 4
125 VAC, 30 VDC resistive load
Durability (10
4
operations)
Switching current (A)
Maximum coil voltage (%)
Ambient temperature (°C)
Te st item: G5NB-1A, 24 VDC Number of Relays: 5 pcs
No current 3A current
Uncon­firmed area
40 60 70
80
100
120
140
160
200
220
80
100
180
0
20 23
Durability Standard models High-capacity models
250 VAC, 30 VDC resistive load
operations)
4
Durability (x 10
Switching current (A)
Ambient Temperature vs. Maximum Coil Voltage Standard models High-capacity models
Te st Item: G5NB-1A-E,24 VDC Number of Relays: 5 pcs
Uncon­firmed area
No current 3A current
G
5 N B
Maximum coil voltage (%)
Ambient temperature (°C)
Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage.
Shock malfunction All models
G5NB-1A
1,000 1,000
X
Z
1,000
125
1,000
Y
Y'
1,000
700
Energized
De-energized
Unit: m/s
Y
Y'
Z'
X'
1,000
2
Shock direction
X
X'
Number of Relays: 5 pcs
Test Method: Shock was applied 3 times in 6 directions along 3 axes and the level at which shock caused malfunction was measured.
Rating: 100 m/s
Z Z'
2
3
Page 4
G5NB PCB Power Relay
G5NB-1A(4)(-E)
PCB Mounting Holes
(Bottom View) Tolerance: ±0.1 mm
(No coil polarity)
Terminal Arrangement/
Internal Connections
(Bottom View)
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation sys
tems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be
sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. J143-E1-03
0812(0207)(O)
Note: Do not use this document to operate the Unit.
Dimensions (Unit: mm)
7.2max.
20.5max. (20.4)*
15.3max. (15.0)*
3.4
0.4
0.27 0.33
11.5 7
Approved Standards
The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values
before use.
UL Recognized: (File No. E41515)
CSA Certified:
Model Contact form Coil ratings Contact ratings
G5NB-1A(4)
G
5
G5NB-1A(4)-E
N B
EN/IEC, VDE Certified
Model Contact form Coil ratings Contact ratings
G5NB-1A(4)
G5NB-1A(4)-E
(File No. LR31928)
SPST-NO
(1a)
5~24V DC
(Registration No. 137575)
SPST-NO
(1a)
5, 12, 18, 24V
DC
3A 125V AC (Resistive) 70°C 3A 30V DC (Resistive) 70°C
5A 250 V AC (Resistive) 85°C 5A 30 V DC (Resistive) 70°C
3A 250V AC (Resistive) 85°C 3A 30V DC (Resistive) 85°C
5A 250 V AC (Resistive) 85°C 5A 30 V DC (Resistive) 85°C
(7.0)*
0.8
4.7
*Average value
(1.05)
(1.15)
4.7
Number of test
operations
6,000
Number of test
operations
100,000
711.5
Four, 1.1 dia.
21
4
3
Precautions
Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
Handling
The G5NB is flux-resistive. Do not wash the G5NB with water.
4
Loading...