Datasheet G5CA-1A-E 24DC, G5CA-1A-E 12DC, G5CA-1A-E 5DC, G5CA-1A 24DC, G5CA-1A 12DC Specification

...
Page 1
G5CA
G5CA-1A@ -@ -@ - @
————— 1234 5
1. Number of Poles
1A: 1-pole/SPST-NO (1a)
2. Enclosure rating
None: Flux protection 4: Fully sealed
3. Terminal Shape
None: PCB terminals TP: Quick-connect
terminals (#187)
4. Classification
None: Standard E: High-capacity
5. Coil consumption
None: Standard H: High-sensitivity
Rated coil voltage
Example: G5CA-1A 5 VDC
PCB Power Relay
Flat Relays that Switch 10A/15A Loads Power
Ideal for switching power in household appliances or for outputs from industrial devices.
Subminiature dimensions: 16 × 22 × 11 mm (L × W × H).
High-sensitivity models available with low power consumption (150 mW).
Standard model conforms to UL/CSA standards.
Fully sealed models are available
Quick-connect terminal models are also available (#187 load contact terminals).
RoHS Compliant
Model Number Legend Application Examples
• Small home appliances
G
5 C A
Ordering Information
Enclosure rating
Flux protection
Fully sealed
Contact form
SPST-NO
Rarings
Coil
Classification Standard, high-capacity, or quick-connect terminals
High-sensitivity
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2.The operating characteristics are measured at a coil temperature of 23°C.
3.The “maximum voltage” is the maximum voltage that can be applied to the relay coil.
Contacts
Item Load Contact type Single Contact material Ag-alloy (Cd free)
Rated load
Rated carry current 10 A 10 A 15 A Max. switching voltage 250 VAC, 125 VDC Max. switching current 10 A 10 A 15 A
Classification
Item
Model
G5CA
-1A
(1a)
G5CA
-1A4
Rated voltage
5 VDC 40 125 12 VDC 16.7 720
24 VDC 8.3 2,880
5 VDC 30 167
24 VDC 6.25 3,840
Standard High-sensitivity High-capacity Quick-connect terminals (#187)
Rated coil
voltage
5 VDC
24 VDC 24 VDC 24 VDC 24 VDC
5 VDC 12 VDC 12 VDC 24 VDC 24 VDC
Item
Rated current
(mA)
Standard High-sensitivity High-capacity, or quick-connect terminals
Resistive load
10 A at 250 VAC; 10 A at 30 VDC
Minimum
packing unit
20 pcs/tube
(cosφ = 0.4, L/R = 7 ms)
3 A at 250 VAC; 3 A at 30 VDC
Model
G5CA
-1A-H
G5CA
-1A4-H
Coil resistance
(Ω)
Inductive load
Rated coil
voltage
5 VDC
5 VDC
Must-operate voltage
Minimum
packing unit
G5CA
-1A-E
20 pcs/tube
(V)
75% max. 10% min.
80% max. 10% min.
Resistive load
10 A at 250 VAC; 10 A at 30 VDC
Must-release voltage
(cosφ = 0.4, L/R = 7 ms)
3 A at 250 VAC; 3 A at 30 VDC
Rated coil
Model
Note 1. When ordering, add the rated coil voltage to the model number.
Note 2. Contact your OMRON representative for details on other coil
Note 3. High-capacity models with a fully sealed structure are not available. Note 4. Standard or high-sensitivity models with quick-connect
voltage
5 VDC
voltage specifications.
terminals are not available.
(V)
% of rated voltage
Inductive load
Minimum
packing unit
20 pcs/tube
150% (standard)/
130% (high-capacity,
quick-connect terminals)
15 A at 110 VAC; 10 A at 30 VDC
Model
G5CA
-1A-TP-E
Max. voltage
(V)
(at 23°C)
150%
(at 23°C)
Resistive load
Rated coil
voltage
5 VDC
(cosφ = 0.4, L/R = 7 ms)
5 A at 110 VAC; 3 A at 30 VDC
Minimum
packing unit
20 pcs/tube12 VDC 12 VDC 12 VDC 12 VDC
Power consumption
(mW)
Approx. 200
Approx. 15012 VDC 12.5 960
Inductive load
1
Page 2
G5CA PCB Power Relay
G
5 C A
Characteristics
Note. The data shown above are initial values. *1. Measurement conditions: 5 VDC, 1 A, voltage drop method. *2. Measurement conditions: Measured at the same points as the
dielectric strength using a 500 VDC ohmmeter.
*3. This value was measured at a switching frequency of 120 operations/min.
Contact resistance *1
30 mΩ max.
(Quick-connect terminals type: 100 mΩ max.) Operate time 10 ms max. Release time 10 ms max. Insulation resistance *2 1,000 MΩ min.
Dielectric strength
Between coil and contacts
2,500 VAC, 50/60 Hz for 1 min
Between contacts of the same polarity
1,000 VAC, 50/60 Hz for 1 min
Impulse withstand voltage
4,500 V (1.2 x 50 μs)
Vibration resistance
Destruction
10 to 55 to 10 Hz, 0.75-mm single amplitude
(1.5-mm double amplitude)
Malfunction
10 to 55 to 10 Hz, 0.75-mm single amplitude
(1.5-mm double amplitude) Shock
resistance
Destruction 1,000 m/s
2
Malfunction 200 m/s
2
Durability
Mechanical
20,000,000 operations min. at 18,000
operations/hr
Electrical
Resistive load
• Standard model 250 VAC 10 A, 300,000 operations min. (100,000 operations min. for plastic-sealed and high-sensitivity models)
• High capacity and quick-connect terminals 110 VAC 15A, 100,000 operations min.
• For all models 30 VDC 10 A, 100,000 operations
Inductive load
100,000 operations min. for all models
(rated load) [Switching frequency at 1,200 operations/h (for all models)]
Failure rate (P level) (Reference value *3)
5 VDC, 100 mA
Ambient Operating temperature
-25°C to 70°C (with no icing or condensation)
Ambient Operating humidity
5% to 85%
Weight Approx. 8 g (for TP model: Approx. 9.6 g)
Engineering Data
Maximum Switching Capacity Durability
Ambient Temperature vs.
Maximum Coil Voltage
Note. The "maximum voltage" is the
maximum voltage that can be applied to the relay coil.
Operating Temperature vs. Must-operate/Must-release Voltage
Shock Malfunction
Sample: G5CA-1A Number of Relays: 10 pcs Measured value: The value at which
malfunction occurs in the contact when the contact is subjected to shock three times each in six directions for three axes.
Standard: 200 m/s
2
Switching voltage (V)
50
30
15
10
7 5
3
1
0.7
0.5
0.3
0.1 1 3 5 7 10 30 50 100 300 500 1,000
DC resistive load G5CA-1A G5CA-1A-E
DC inductive load G5CA-1A G5CA-1A-E (L/R=7ms)
AC resistive load G5CA-1A-E
AC inductive load G5CA-1A-E (cosφ=0.4
AC inductive load G5CA-1A (cosφ=0.4)
ACᛶ᛫⽶⩄ G5C
AC resistive load G5CA-1A
Switching current (A)
Switching current (A)
500
300
100
70 50
30
10
7 5
3
1
0 2 4 6 8 10 12 14 16
30 VDC resistive load
250 VAC resistive load
110 VAC resistive load
Durability (× 10
4
operation)
100
80
60
40
20
0
40 20 0 20 40 60 80
Ambient temperature (°C)
Must-operate voltage Must-release voltage
Sample: G5CA-1A Number of Relays: 5 pcs
max.
min.
X
max.
min.
X
Must-operate/must-release voltage (%)
Z'
Z
Z
Z'
Shock direction
Unit: m/s
2
Y
Y
Y'
Y'
XXX'
X'
1,000 min.
1,000 min.
1,000 min.
1,000 min.
1,000 min.
1,000 min.
800
600
400
200
200
400
600
800
G5CA-1A(-E) G5CA-1A4(-H)
0.3
12.7
16 max.
(15.9)*
22 max.
(21.9)*
11 max.
(10.9)*
0.4
3.5
1.6
10.16 7.62
0.6
* Average value
(No coil polarity)
Two, 1 dia. hole
Two, 1 dia.
elliptic holes
2.54
2.54
2
10.16
17.78
12.7
Note. Orientation marks are indicated as follows:
12
34
PCB Mounting Holes
(BOTTOM VIEW) Tolerance: ±0.1 mm
Terminal Arrangement/ Internal Connections
(BOTTOM VIEW)
G5CA-1A-TP-E
10°
±1°
0.5
0.614.25
17.78
22.1 max. (21.9)*
25.1 max. (24.9)*
11
(10.9)*
0.5
4.8
3.2
1
0.4
1.35
6.35
13.4
5
1.3 dia.
516.1
0.3
3.5
* Average value
Two, 1 dia. Four, 1.2 dia.
elliptic holes
1.8
14.25
6.25
21.1
16.11.6
17.78
5
4
3
2
1
(TOP VIEW)
(BOTTOM VIEW)
(No coil polarity)
PCB Mounting Holes
(BOTTOM VIEW) Tolerance: ±0.1 mm
Terminal Arrangement/ Internal Connections
(BOTTOM VIEW)
Dimensions
2
200
180
160
150
140
Maximum coil voltage (%)
130
120
100
80
60
0 20 30 40 50 60 70 80 90
Continuous max. permissile voltage (10 A)
Continuous max. permissile voltage (15 A)
Ambbient temperature (°C)
Page 3
G5CA PCB Power Relay
Approved Standards
The following UL-, CSA-, and EN/TÜV-certifying ratings differ from the performance characteristics of the individual models.
UL Recognized: (File No. E41515) CSA Certified: (File No. LR31928)
EN Certified/TÜV (Certification No. R50214486)
Model
Contact
form
Coil
ratings
Contact ratings
Number of
test
operations
G5CA
SPDT-NO
(1a)
5 to 100
VDC
15 A, 125 VAC (General purpose) at 40°C
100,00010 A, 250 VAC (General purpose) at 40°C 10 A, 30 VDC (Resistive) at 40°C
Model
Contact
form
Coil
ratings
Contact ratings
Number of
test
operations
G5CA
SPDT-NO
(1a)
5 to 100
VDC
15 A, 125 VAC (General purpose) at 40°C
100,00010 A, 250 VAC (General purpose) at 40°C 10 A, 30 VDC (Resistive) at 40°C
Model
Contact
form
Coil
ratings
Contact ratings
Number of
test
operations
G5CA
SPDT-NO
(1a)
5, 6, 12,
24, 48
VDC
15 A, 125 VAC (cosφ = 1.0) at 85°C
100,00010 A, 250 VAC (cosφ = 1.0) at 85°C
10 A, 30 VDC (0 ms) at 85°C
Mounting
• Make sure that sufficient space is provided between relays when installing two or more relays side by side to facilitate heat dissipation. Insufficient heat dissipation may result in the relay malfunctioning.
Quick-connect Terminal Connections
• Do not pass current through the PCB of the load contact terminals (quick-connect terminals).
• The terminals are compatible with Faston receptacle #187 and are suitable for positive-lock mounting. Use only Faston terminals with the specified numbers. Select leads for connecting Faston receptacles with wire diameters that are within the allowable range for the load current. Do not apply excessive force to the terminals when mounting or dismounting the Faston receptacle. Insert and remove terminals carefully one at a time. Do not insert terminals on an angle, or insert/remove multiple terminals at the same time. The following positive-lock connectors made by AMP are recommended. Contact the manufacturer directly for details on connectors including availability.
* The numbers shown in parentheses are for
air-feeding.
Charged Terminals
• The section marked with dotted circles (indicated by arrows) in the following diagram includes the charged terminals of the relay. When the relay is mounted on a PCB, make sure that there are no metal patterns on the section of the PCB facing the portion of the relay shaded in the following diagram.
Other Precautions
• The G5CA is a power relay designed for applications switching power loads such as heaters in electric household appliances. Do not use the G5CA to switch micro loads less than 100 mA, such as in signal applications.
• Use fully sealed models if the relays will require washing. Flux-protection models may malfunction or the relay's performance may be otherwise adversely affected if cleaning fluid enters the relay.
Correct Use
Pitch:
2.54 mm × 4 min. between terminals
Pitch: 2.54 mm × 3 min. between terminals
Type
Receptacle
terminals *
Positive housing
#187 terminals (width:
4.75 mm)
AMP 170330-1
(170324-1)
AMP 170331-1
(170325-1)
AMP 170332-1
(170326-1)
AMP 172074-1 (natural color) AMP 172074-4 (yellow) AMP 172074-5 (green) AMP 172074-6 (blue)
12.7
0.18
8
6.5
Precautions
Please refer to “PCB Relays Common Precautions” for correct use.
G
5 C A
3
Page 4
G5CA PCB Power Relay
G
5 C A
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. J151-E1-03
0812(0207)(O)
Note: Do not use this document to operate the Unit.
4
Loading...