G5CA
G5CA-1A@ -@ -@ - @
——————
1234 5
1. Number of Poles
1A: 1-pole/SPST-NO (1a)
2. Enclosure rating
None: Flux protection
4: Fully sealed
3. Terminal Shape
None: PCB terminals
TP: Quick-connect
terminals (#187)
4. Classification
None: Standard
E: High-capacity
5. Coil consumption
None: Standard
H: High-sensitivity
Rated coil voltage
Example: G5CA-1A 5 VDC
PCB Power Relay
Flat Relays that Switch
10A/15A Loads Power
•
Ideal for switching power in household appliances or for
outputs from industrial devices.
•
Subminiature dimensions: 16 × 22 × 11 mm (L × W × H).
•
High-sensitivity models available with low power
consumption (150 mW).
•
Standard model conforms to UL/CSA standards.
•
Fully sealed models are available
•
Quick-connect terminal models are also available (#187
load contact terminals).
RoHS Compliant
■Model Number Legend ■Application Examples
• Small home appliances
G
5
C
A
■Ordering Information
Enclosure
rating
Flux
protection
Fully
sealed
Contact form
SPST-NO
■Rarings
●Coil
Classification
Standard,
high-capacity,
or quick-connect
terminals
High-sensitivity
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2.The operating characteristics are measured at a coil temperature of 23°C.
3.The “maximum voltage” is the maximum voltage that can be applied to the relay coil.
●Contacts
Item Load
Contact type Single
Contact material Ag-alloy (Cd free)
Rated load
Rated carry current 10 A 10 A 15 A
Max. switching voltage 250 VAC, 125 VDC
Max. switching current 10 A 10 A 15 A
Classification
Item
Model
G5CA
-1A
(1a)
G5CA
-1A4
Rated voltage
5 VDC 40 125
12 VDC 16.7 720
24 VDC 8.3 2,880
5 VDC 30 167
24 VDC 6.25 3,840
Standard High-sensitivity High-capacity Quick-connect terminals (#187)
Rated coil
voltage
5 VDC
24 VDC 24 VDC 24 VDC 24 VDC
5 VDC
12 VDC 12 VDC
24 VDC 24 VDC
Item
Rated current
(mA)
Standard High-sensitivity High-capacity, or quick-connect terminals
Resistive load
10 A at 250 VAC;
10 A at 30 VDC
Minimum
packing unit
20 pcs/tube
(cosφ = 0.4, L/R = 7 ms)
3 A at 250 VAC;
3 A at 30 VDC
Model
G5CA
-1A-H
G5CA
-1A4-H
Coil resistance
(Ω)
Inductive load
Rated coil
voltage
5 VDC
5 VDC
Must-operate voltage
Minimum
packing unit
G5CA
-1A-E
20 pcs/tube
(V)
75% max. 10% min.
80% max. 10% min.
Resistive load
10 A at 250 VAC;
10 A at 30 VDC
Must-release voltage
(cosφ = 0.4, L/R = 7 ms)
3 A at 250 VAC;
3 A at 30 VDC
Rated coil
Model
Note 1. When ordering, add the rated coil voltage to the model number.
Note 2. Contact your OMRON representative for details on other coil
Note 3. High-capacity models with a fully sealed structure are not available.
Note 4. Standard or high-sensitivity models with quick-connect
voltage
5 VDC
voltage specifications.
terminals are not available.
(V)
% of rated voltage
Inductive load
Minimum
packing unit
20 pcs/tube
150% (standard)/
130% (high-capacity,
quick-connect terminals)
15 A at 110 VAC;
10 A at 30 VDC
Model
G5CA
-1A-TP-E
Max. voltage
(V)
(at 23°C)
150%
(at 23°C)
Resistive load
Rated coil
voltage
5 VDC
(cosφ = 0.4, L/R = 7 ms)
5 A at 110 VAC;
3 A at 30 VDC
Minimum
packing unit
20 pcs/tube12 VDC 12 VDC 12 VDC 12 VDC
Power consumption
(mW)
Approx. 200
Approx. 15012 VDC 12.5 960
Inductive load
1

G5CA PCB Power Relay
■Characteristics
Note. The data shown above are initial values.
*1. Measurement conditions: 5 VDC, 1 A, voltage drop method.
*2. Measurement conditions: Measured at the same points as the
dielectric strength using a 500 VDC ohmmeter.
*3. This value was measured at a switching frequency of 120 operations/min.
Contact resistance *1
30 mΩ max.
(Quick-connect terminals type: 100 mΩ max.)
Operate time 10 ms max.
Release time 10 ms max.
Insulation resistance *2 1,000 MΩ min.
Dielectric
strength
Between coil
and contacts
2,500 VAC, 50/60 Hz for 1 min
Between
contacts of
the same
polarity
1,000 VAC, 50/60 Hz for 1 min
Impulse withstand
voltage
4,500 V (1.2 x 50 μs)
Vibration
resistance
Destruction
10 to 55 to 10 Hz, 0.75-mm single amplitude
(1.5-mm double amplitude)
Malfunction
10 to 55 to 10 Hz, 0.75-mm single amplitude
(1.5-mm double amplitude)
Shock
resistance
Destruction 1,000 m/s
2
Malfunction 200 m/s
2
Durability
Mechanical
20,000,000 operations min. at 18,000
operations/hr
Electrical
Resistive load
• Standard model
250 VAC 10 A, 300,000 operations min.
(100,000 operations min. for plastic-sealed
and high-sensitivity models)
• High capacity and quick-connect
terminals
110 VAC 15A, 100,000 operations min.
• For all models
30 VDC 10 A, 100,000 operations
Inductive load
100,000 operations min. for all models
(rated load)
[Switching frequency at 1,200 operations/h
(for all models)]
Failure rate (P level)
(Reference value *3)
5 VDC, 100 mA
Ambient Operating
temperature
-25°C to 70°C (with no icing or condensation)
Ambient Operating
humidity
5% to 85%
Weight Approx. 8 g (for TP model: Approx. 9.6 g)
■Engineering Data
●Maximum Switching Capacity ●Durability
● Ambient Temperature vs.
Maximum Coil Voltage
Note. The "maximum voltage" is the
maximum voltage that can be applied
to the relay coil.
● Operating Temperature vs.
Must-operate/Must-release
Voltage
●Shock Malfunction
Sample: G5CA-1A
Number of Relays: 10 pcs
Measured value: The value at which
malfunction occurs in
the contact when the
contact is subjected to
shock three times
each in six directions
for three axes.
Standard: 200 m/s
2
Switching voltage (V)
50
30
15
10
7
5
3
1
0.7
0.5
0.3
0.1
1 3 5 7 10 30 50 100 300 500 1,000
DC resistive load
G5CA-1A
G5CA-1A-E
DC inductive load
G5CA-1A
G5CA-1A-E
(L/R=7ms)
AC resistive load
G5CA-1A-E
AC inductive load
G5CA-1A-E
(cosφ=0.4㧕
AC inductive load
G5CA-1A
(cosφ=0.4)
ACᛶ᛫⽶⩄
ᒻG5C
AC resistive load
G5CA-1A
Switching current (A)
Switching current (A)
500
300
100
70
50
30
10
7
5
3
1
0 2 4 6 8 10 12 14 16
30 VDC resistive load
250 VAC resistive load
110 VAC resistive load
Durability (× 10
4
operation)
100
80
60
40
20
0
−40 −20 0 20 40 60 80
Ambient temperature (°C)
Must-operate voltage
Must-release voltage
Sample: G5CA-1A
Number of Relays: 5 pcs
max.
min.
X
max.
min.
X
Must-operate/must-release voltage (%)
Z'
Z
Z
Z'
Shock direction
Unit: m/s
2
Y
Y
Y'
Y'
XXX'
X'
1,000 min.
1,000 min.
1,000 min.
1,000 min.
1,000 min.
1,000 min.
800
600
400
200
200
400
600
800
0.3
12.7
16 max.
(15.9)*
22 max.
(21.9)*
11 max.
(10.9)*
0.4
3.5
1.6
10.16 7.62
0.6
* Average value
(No coil polarity)
Two, 1 dia. hole
Two, 1 dia.
elliptic holes
2.54
2.54
2
10.16
17.78
12.7
Note. Orientation marks are indicated
as follows:
12
34
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
10°
±1°
0.5
0.614.25
17.78
22.1 max.
(21.9)*
25.1 max.
(24.9)*
11
(10.9)*
0.5
4.8
3.2
1
0.4
1.35
6.35
13.4
5
1.3 dia.
516.1
0.3
3.5
* Average value
Two, 1 dia. Four, 1.2 dia.
elliptic holes
1.8
14.25
6.25
21.1
16.11.6
17.78
5
4
3
2
1
(TOP VIEW)
(BOTTOM VIEW)
(No coil polarity)
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
■Dimensions
2
200
180
160
150
140
Maximum coil voltage (%)
130
120
100
80
60
0 20 30 40 50 60 70 80 90
Continuous max.
permissile voltage (10 A)
Continuous max.
permissile voltage (15 A)
Ambbient temperature (°C)

G5CA PCB Power Relay
■Approved Standards
●The following UL-, CSA-, and EN/TÜV-certifying ratings differ from the performance characteristics of the individual models.
UL Recognized: (File No. E41515) CSA Certified: (File No. LR31928)
EN Certified/TÜV (Certification No. R50214486)
Model
Contact
form
Coil
ratings
Contact ratings
Number of
test
operations
G5CA
SPDT-NO
(1a)
5 to 100
VDC
15 A, 125 VAC (General purpose)
at 40°C
100,00010 A, 250 VAC (General purpose)
at 40°C
10 A, 30 VDC (Resistive) at 40°C
Model
Contact
form
Coil
ratings
Contact ratings
Number of
test
operations
G5CA
SPDT-NO
(1a)
5 to 100
VDC
15 A, 125 VAC (General purpose)
at 40°C
100,00010 A, 250 VAC (General purpose)
at 40°C
10 A, 30 VDC (Resistive) at 40°C
Model
Contact
form
Coil
ratings
Contact ratings
Number of
test
operations
G5CA
SPDT-NO
(1a)
5, 6, 12,
24, 48
VDC
15 A, 125 VAC (cosφ = 1.0) at
85°C
100,00010 A, 250 VAC (cosφ = 1.0) at
85°C
10 A, 30 VDC (0 ms) at 85°C
● Mounting
• Make sure that sufficient space is
provided between relays when
installing two or more relays side by
side to facilitate heat dissipation.
Insufficient heat dissipation may result
in the relay malfunctioning.
● Quick-connect Terminal
Connections
• Do not pass current through the PCB
of the load contact terminals
(quick-connect terminals).
• The terminals are compatible with
Faston receptacle #187 and are
suitable for positive-lock mounting.
Use only Faston terminals with the
specified numbers. Select leads for
connecting Faston receptacles with
wire diameters that are within the
allowable range for the load current.
Do not apply excessive force to the
terminals when mounting or
dismounting the Faston receptacle.
Insert and remove terminals carefully
one at a time. Do not insert terminals
on an angle, or insert/remove multiple
terminals at the same time.
The following positive-lock connectors
made by AMP are recommended.
Contact the manufacturer directly for
details on connectors including
availability.
* The numbers shown in parentheses are for
air-feeding.
● Charged Terminals
• The section marked with dotted circles
(indicated by arrows) in the following
diagram includes the charged
terminals of the relay.
When the relay is mounted on a PCB,
make sure that there are no metal
patterns on the section of the PCB
facing the portion of the relay shaded
in the following diagram.
● Other Precautions
• The G5CA is a power relay designed
for applications switching power loads
such as heaters in electric household
appliances. Do not use the G5CA to
switch micro loads less than 100 mA,
such as in signal applications.
• Use fully sealed models if the relays
will require washing. Flux-protection
models may malfunction or the relay's
performance may be otherwise
adversely affected if cleaning fluid
enters the relay.
Correct Use
Pitch:
2.54 mm × 4 min.
between terminals
Pitch: 2.54 mm × 3 min.
between terminals
Type
Receptacle
terminals *
Positive housing
#187
terminals
(width:
4.75 mm)
AMP 170330-1
(170324-1)
AMP 170331-1
(170325-1)
AMP 170332-1
(170326-1)
AMP 172074-1
(natural color)
AMP 172074-4
(yellow)
AMP 172074-5
(green)
AMP 172074-6
(blue)
■Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.
G
5
C
A
3

G5CA PCB Power Relay
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. J151-E1-03
0812(0207)(O)
Note: Do not use this document to operate the Unit.
4