Datasheet DMS-BZL4, DMS-BZL3, DMS-20-CP, DMS-20LCD-4-20S, DMS-20LCD-4-20P Datasheet (DATEL)

...
Page 1
DATEL, Inc., Mansfield, MA 02048 (USA) • T el: (508)339-3000, (800)233-2765 Fax: (508)339-6356 • E–mail: sales@datel.com • Internet: www.datel.com
DMS-20LCD-4/20 Series
Figure 1. DMS-20LCD-4/20 Series Simplified Schematic
Features
®®
The DMS-20LCD-4/20 Series produces the lowest loop voltage-drop of any compa­rably priced, 4-20mA input, 3½ digit LCD-display process monitors: 1.8V typical, 2.0V max. This super-low drop means its nominal loop resistance (burden) is less than 100 Ohms! All operating power is derived solely from the 4-20mA loop current—no separate power source is required! The simple 2-wire hookup allows the DMS-20LCD-4/20 Series to be connected anywhere in the loop
All decimal-point and range-change selections are made via a six-position DIP switch featuring vibration-resistant, gold-plated contacts—there are no jumpers or solder gaps to ever open or close. Both gain (span) and offset (zero) adjustments are per­formed with precision, 20-turn potentiometers. Three different models are available for unipolar, bipolar , and positive display reading applications. The DMS-20LCD-4/20’s DIP switch and adjustment potentiometers can accommodate literally hundreds of different input-current/output-reading combinations. And, connections to the current loop are made via a reliable, two-position, screw-type terminal block.
The DMS-20LCD-4/20 Series’ subminiature package houses a large, 0.37"/9.4mm high digits, LCD display that can be read in virtually all lighting conditions—including direct sunlight. An optional bezel assembly , featuring screw fasteners and a rubber seal, simplifies panel mounting and provides excellent resistance to environmental dust and moisture. All these outstanding features combine to make the DMS-20LCD-4/20 Series the perfect meters for OEM 4-20mA current-loop process monitoring instrumentation.
••
••
Super-low loop drop: 1.8V typical, 2.0V max.
••
••
Self-powered, no separate supply required
••
••
Unipolar, Bipolar, and Positive Reading Models
••
••
Subminiature package—Less than 0.90” behind-the-panel depth
••
••
Large, 0.37"/9.4mm high, sunlight-viewable LCD display
••
••
Non-interacting gain (span) and offset (zero) 20-turn potentiometers
••
••
DIP-switch selectable range and decimal points
••
••
Hundreds of different input/readout combinations
••
••
Vibration-resistant package; reliable screw-terminal input connections
DATA
3 ½ D IG IT A /D CONVERTER
DC/DC
CONVERTER
BAND-G AP
REFERENCE
CIRCUIT
DIP SW ITCHES
ZER O
ADJUST
GAIN
ADJUST
123
CURRENT TO
VOLTAGE
CONVERTER
+5V 5V
DP3DP2DP1
R3 R7
TB1
LO O P IN P U T
5
61
112
2
2
3456
3
344
5
6
ON
ON
ON
+
4-20mA Input Loop-Powered
Ultra-Low 1.8V Loop Drop , 3½ Digit
LCD-Display Process Monitors
Actual Size
Order on-line at www.datel.com
Page 2
2
DATEL, Inc., Mansfield, MA 02048 (USA) • T el: (508)339-3000, (800)233-2765 Fax: (508)339-6356 • E–mail: sales@datel.com • Internet: www.datel.com
DMS-20LCD-4/20
3½ DIGIT, LCD DISPLAY, 4-20mA LOOP-POWERED METERS
Operating and Setup Instructions
Performance/Functional Specifications
Typical at TA = +25°C, unless otherwise noted.
À
The DMS-20LCD-4/20, using any of the DIP-switch settings described above, can
withstand overcurrents, including those resulting from accidental reverse-polarity connections, up to ±40mA without sustaining any damage.
Á
Because DATEL's DMS-4/20 loop-powered meters employ active circuitry to
convert the loop current into a voltage, the meters' effective series impedance varies in a manner that maintains the loop voltage drop constant over the full 4-to-20mA current range. Listed impedance specification applies at 20mA.
1. Set R7 (full scale span/gain adjust) and R3 (zero/offset adjust) fully clockwise, roughly 22 turns, and place SW1-SW6 to OFF.
2. Select DIP switch setting #2.
Current Loop Input Min. Typ. Max. Units
Full Scale Input Range
À
+3.8 –– +20.4 mA
Input Impedance
Á
–– 80 100
Voltage Drop
Á
–– 1.8 2.0 Volts
Overcurrent Protection
À
–– –– ±40 mA
Performance
Sampling Rate 2.5 readings per second Accuracy (1 minute warmup) ±0.05%FS ±1 Count Temperature Drift (0 to +60°C) –– ±0.15 ±0.3 Cnts/°C
Display
Display Type and Size 3½ digit LCD, 0.37"/9.4mm Polarity Indication "–" for negative readings Overrange Indication "–1_ _ _ " for negative inputs
"1_ _ _ " for positive inputs
Physical/Environmental
Operating Temperature 0 –– +60 °C Storage Temperature 20 –– +75 °C Humidity (Noncondensing) 0 –– 95 % Case Material Polycarbonate Weight 0.6 ounces (17 grams)
Display Reading SW1 SW2 SW3
4mA 20mA
1. 000 to 1050-1999 Off Off Off
2. 000 to 650-1350 On Off Off
3. 000 to 450-800 Off On Off
4. 000 to 300-500 Off Off On
5. 000 to 200-300 On On On
Table 1. DMS-20LCD-4/20S (Unipolar Model)
DIP-Switch Settings
Â
DMS-20LCD-4/20S Unipolar reading, loop-powered LCD meter DMS-20LCD-4/20B Bipolar reading, loop-powered LCD meter DMS-20LCD-4/20P Positive reading, loop-powered LCD meter DMS-BZL3 Bezel assembly DMS-BZL4 Bezel assembly with sealing gasket DMS-20-CP Panel cutout punch
Ordering Information
A panel-mount retaining clip is supplied with each model.
1. Desired display readings are: 4mA ="0.00"
20mA = "6.00"
Use DIP-switch setting #3 in Table 1 and enable decimal point DP2 via SW5. Apply 4mA and adjust R3 so the display reads "0.00". Apply 20mA and adjust R7 so the display reads "6.00".
2. Desired display readings are: 4mA = "000"
20mA = "800"
Use DIP-switch setting #2 in Table 1. Apply 4mA and adjust R3 so the display reads "000". Apply 20mA and adjust R7 so the display reads "800". For these display readings, no decimal points are used. Set SW4, SW5 and SW6 to OFF.
3. Desired display readings are: 4mA = ".000"
12mA = ".250"
This example is not as straightforward as the previous two. Notice that 12mA is exactly halfway between 4mA and 20mA. If we assume that the input could go up to 20mA, the display reading would then be: 2 x .250 or ".500". F rom Table 1 we can now select DIP-switch setting #4 and enable DP1 via SW4. Apply 4mA and adjust R3 so the display reads ".000". Apply 12mA and adjust R7 so the display reads ".250".
Examples (DMS-20LCD-4/20S-Unipolar Model)
ON
1
2
3
4
5
6
ON
DMS-20LCD-4/20S (Unipolar Reading Model)
As shipped, the DMS-20LCD-4/20S is factory calibrated to read "000" for a 4mA input and "1000" for a 20mA input. The following worst-case procedure assumes the DMS-20LCD-4/20S is completely mis-adjusted, i.e., both potentiometers and the DIP switches are randomly set. When performing DIP­switch settings, be sure the DIP switch's small actuators are firmly engaged in their fully-ON or fully-OFF positions.
1
2
3
4
5
6
ON
1
2
3
4
5
6
ON
Order on-line at www.datel.com
Â
When looking up DIP-switch settings in the Tables and the desired display readings can be achieved with either of two different settings, using the higher setting # will produce less sensitive offset (R3) and span (R7) adjustments. Please keep in mind that the DMS-20LCD standard meter (from which the DMS-20LCD-4/20 is derived) has an accuracy specification of ±2 counts (max.). Thus, it may not always be possible to obtain the exact desired display reading.
3. Apply a precision 4mA input, with proper polarity , and adjust R3 until the
meter's display reads "000".
4. Apply a precision 20mA input and adjust R7 until the meter's display
reads "1000". Repeat steps 3 and 4 to make sure the adjustments do not affect one another.
5. Select the appropriate decimal point by setting SW4, SW5 or SW6 to
ON (DP1, DP2 or DP3 respectively). NOTE: If a display reading other than "000" to "1000" is desired,
refer to DIP–Switch Settings Table 1 for SW1–SW3 settings.
Page 3
3
DATEL, Inc., Mansfield, MA 02048 (USA) • T el: (508)339-3000, (800)233-2765 Fax: (508)339-6356 • E–mail: sales@datel.com • Internet: www.datel.com
3½ DIGIT, LCD DISPLAY, 4-20mA LOOP-POWERED METERS
DMS-20LCD-4/20DMS-20LCD-4/20
DMS–20LCD–4/20B (Bipolar Reading Model)
The DMS-20LCD-4/20B's zero-offset circuit differs from the unipolar 'S' model described above in that with the 'B' model, a half-scale 12mA input is normally set to display "000". Therefore , all of the of the DIP-switch settings in Table 2 assume a reading of "000" is desired with a 12mA input. Display readings other than those shown in Table 2 are possible, contact DATEL for more information.
When configuring the DMS-20LCD-4/20B for the first time, or when selecting a new range, set both R3 and R7 fully clockwise (roughly 22 turns) to their minimum offset/minimum-span positions, respectively. Then select the desired readings from Table 2 and configure DIP-switches SW1, SW2, and SW3 accordingly .
The procedure below illustrates how to calibrate the DMS-20LCD-4/20B to its factory-calibrated readings of "–1000" with a 4mA input and "1000" with a 20mA input. When performing DIP-switch settings, be sure the DIP-switch's small actuators are firmly engaged in their fully-ON or fully-OFF positions.
1. Set both R3 and R7 fully clockwise.
2. Select DIP-switch setting #1 from Table 2.
3. Apply a precision 12mA input and adjust R3 until the meter's display
reads "000".
4. Apply a precision 20mA input and adjust R7 until the meter's display reads "1000".
5. Apply a precision 4mA input and the display should read "–1000". Repeat steps 3 and 4 to make sure the two adjustments did not affect one another.
Examples (DMS-20LCD-4/20B-Bipolar Model)
1. Desired display readings are: 4mA = "–1.00"
20mA = "1.00"
Use DIP-switch setting #5 in Table 2 and enable decimal point DP2 via SW5. Apply 12mA and adjust R3 so the display reads "0.00". Apply 20mA and adjust R7 so the display reads "1.00". Apply 4mA and verify that the display reads "–1.00", readjust R3 and R7 if necessary .
2. Desired display readings are: 4mA = "–450"
20mA = "450"
Use DIP-switch setting #2 in Table 2. Apply 12mA and adjust R3 so the display reads "000". Apply 20mA and adjust R7 so the display reads "450". Apply 4mA and verify that the display reads "–450". Repeat adjustment procedure if necessary . For these display readings, no decimal points are used. Set SW4, SW5 and SW6 to OFF.
3. Desired display readings are: 4mA = "–650"
20mA = "650"
Notice that these readings can be obtained using either DIP-switch setting #1 or DIP-switch setting #2 in Table 2. In situations like this where DIP-switch settings overlap, less-sensitive R3/R7 adjustments can be achieved if the higher DIP-setting # is selected (setting #2 in this example). Apply 12mA and adjust R3 so the display reads "000". Apply 20mA and adjust R7 so the display reads "650". Apply 4mA and verify that the display reads "– 650". Repeat adjustment procedure if necessary.
1
2
3
4
5
6
ON
1
2
3
4
5
6
ON
Display Reading SW1 SW2 SW3
4mA 12mA 20mA
1. –600 to –1000 000 600 to 1000 O f f Off Off
2. –350 to –650 000 350 to 650 O n Off Off
3. –250 to –400 000 250 to 400 Of f On Off
4. –150 to –250 000 150 to 250 Of f Off On
5. –100 to –150 000 100 to 150 O n On On
Table 2. DMS-20LCD-4/20B (Bipolar Model)
DIP-Switch Settings
Â
1
2
3
4
5
6
ON
DMS-20LCD-4/20P (Positive Reading Model)
The DMS-20LCD-4/20Ps Zero-Offset circuit is optimized to produce positive readings at both 4mA and 20mA input levels. As shown in Table 3’s first three columns, a 4mA input can be typically adjusted (using R3, Zero/ Offset Adjust) to display any positive reading between “000” and 800. The corresponding 20mA-input reading is then added to the 4mA offset as a differential whose magnitude is varied by adjusting R7 (Gain/Span Adjust).
The ‘Differential Range’ column in Table 3 lists the nominal differential display-readings which can be obtained with R7 at, or very close to, its full­clockwise, minimum span position. The Differential Range column can be used as a guide when configuring the meter for the majority of user applications. Higher differential ranges are obtainable; however, the use of higher differential readings results in correspondingly-lower positive readings with 4mA inputs, that is, R3’s clockwise adjustment-range is reduced. Example #3 belo w illustrates this concept. Please contact DA TEL if there is any doubt as to whether or not the DMS-20LCD-4/20P can be configured for your display readings requirements.
The first step when configuring the DMS-20LCD-4/20P for the first time, or when selecting a new range, is to set R3 fully counterclockwise and R7 fully clockwise (roughly 22 turns) to their minimum offset/minimum span positions, respectively.
The next step is to calculate the required display differential-reading; this is accomplished by subtracting the desired 4mA display reading from the desired 20mA display reading, disregarding decimal points. Then, using the calculated differential display-reading to select the appropriate DIP-switch setting # from Table 3, configure DIP-switches SW1, SW2, and SW3 accordingly . Make certain that the DIP-switchs small actuators are firmly engaged in their fully-ON or fully-OFF positions.
The procedure below describes how to calibrate the meter for an applica­tion which the DMS-20LCD-4/20P easily accommodates: displaying the output of a 4-20mA transmitter, that is, "04.0" with a 4mA input and "20.0" with a 20mA input.
Page 4
4
DATEL, Inc., Mansfield, MA 02048 (USA) • T el: (508)339-3000, (800)233-2765 Fax: (508)339-6356 • E–mail: sales@datel.com • Internet: www.datel.com
DMS-20LCD-4/20
3½ DIGIT, LCD DISPLAY, 4-20mA LOOP-POWERED METERS
Table 4. Decimal Point Settings
Figure 2. Typical DMS-20LCD-4/20 Connection Diagram
1. Set R3 fully counterclockwise (minimum offset position) and R7 fully
clockwise (minimum differential span position), roughly 22 turns.
2. Subtract 040 from 200 to yield a differential value of 160; use this value to select DIP-switch setting #5 in Table 3. Enab le decimal point DP3 by placing SW6 to the ON position.
3. Set the transmitter’s output to 4.0mA and carefully adjust R3 clockwise until the meters display reads 000”.
4. Set the transmitter’s output to 20.0mA and adjust R7 counterclock- wise until the meters display reads 16.0”.
5. Set the transmitter back to 4.0mA and slowly adjust R3 clockwise until the display reads 04.0. Reapply 20.0mA and the display should now read 20.0”. Repeat steps 3, 4 and 5 to make sure the adjustments did not affect one another.
Examples (DMS-20LCD-4/20P-Positive Model)
1. Desired display readings are: 4mA = “650”
20mA = “950”
Use DIP-switch setting #4 in Table 3 since subtracting 650 from 950 yields a differential value of 300. Apply 4mA and adjust R3 until the display reads 000”. Apply 20mA and adjust R7 until the display reads 300 (the differential value previously calculated). Apply 4mA and adjust R3 until the display reads 650”. Apply 20mA and verify that the display reads 950”.
2. Desired display readings are: 4mA = 4.00
20mA = 19.99
This example illustrates the DMS-20LCD-4/20Ps capability to display higher differential readings than those indicated in T able 3. This example also illustrates how the DMS-20LCD-4/20P can be used to display the output levels of a 4-20mA loop transmitter with higher precision (0.01mA versus
0.1mA) than described above.
Subtracting 400 from 1999 yields a differential of 1599, a value not listed in T a ble 3. Howe ver, use DIP-switch setting #1 in Table 3 since this setting has the highest overall offset/span adjustment capabilities. Enable DP2 via SW5 then apply 4mA and adjust R3 so the display reads 0.00. Apply 20mA and adjust R7 so the display reads 15.99. Apply 4mA and adjust R3 until the display reads 4.00. Apply 20mA and check to see that the display reads 19.99 or just overranges (1—“). Repeat adjustment procedure if necessary .
ON
1
2
3
4
5
6
ON
ON
1
2
3
4
5
6
ON
Table 3. DMS-20LCD-4/20P (Positive Reading Model)
DIP-Switch Settings
Â
Differential Range 4mA Input 20mA Input
Display Reading
SW1 SW2 SW3
À
Shown for illustrative purposes only, may not be present in all applications
À
SW4 SW5 SW6
DP1 DP2 DP3
1. 800-1400 9 00 1700 Of f Of f Off
2. 500-800 85 0 1350 On Off Off
3. 350-500 80 0 1150 Off On Off
4. 250-350 75 0 1000 Off Of f On
5. 150-250 75 0 900 O n On On
A/D
PROGRAMMABLE LOGIC CONTROLLER
TRANSMITTER &
SIGNAL CONDITIONER
TRANSDUCER
INPUT
+
DMS-20LCD-4/20
+
Vsig
+
GAIN
ZERO
+24V
4-20mA
4-20mA
+
+24Vdc
SUPPLY
+
(TB1-1)
R7
R3
(TB1-2)
Page 5
5
DATEL, Inc., Mansfield, MA 02048 (USA) • T el: (508)339-3000, (800)233-2765 Fax: (508)339-6356 • E–mail: sales@datel.com • Internet: www.datel.com
3½ DIGIT, LCD DISPLAY, 4-20mA LOOP-POWERED METERS
DMS-20LCD-4/20
Mechanical Specifications
MECHANICAL DIMENSIONS: Inches (mm) TOLERANCES: 2 PL DEC ±0.02 (±0.51)
3 PL DEC ±0.010 (±0.254)
WIRE SIZE: 18 to 26 AWG
(Solid or stranded)
STRIPPING LENGTH: 0.20" (5.08mm)
#2-56 INSERT
0.156 (3.96) DEEP
FRONT VIEW
1.280
(32.51)
0.187 (4.75)
OPTIONAL BEZEL (DMS-BZL3 and DMS-BZL4)
RECOMMENDED DRILL AND PANEL CUTOUT DIMENSIONS
1.826 (46.38)
0.838
(21.29)
1.336 (33.93)
1.626 (41.30)
1.07
(27.18)
INTERNAL CORNER RADII:
0.032 (0.81) MAX.
0.145 (3.68)
0.093 (2.362) DIAMETER (4 REQUIRED) ONLY WHEN USING OPTIONAL BEZEL ASSEMBLY
0.116
(2.95)
®®
BEZEL INSTALLATION
BEZEL
PANE
L
®®
RETAINING CLIP INSTALLATION
PANE
L
Back View
Front View
DIP
Switches
Gain/Span
Adjust
Zero/Offset
Adjust
Loop Input
DP2
(SW5)
DP3
(SW6)
DP1
(SW4)
0.80
(20.3)
0.040 (1.02)
1.30
(33.0)
1.38
(35.1)
0.88
(22.4)
0.90
(22.9)
MADE IN USA
DMS-20LCD-4/20
®®
R3
R7
12
1
1
1
2
2
3456
34
5 6
ON
ON
+
1 2 3 4 5 6
ON
12
Page 6
DATEL, Inc. 1 1 Cabot Boulevard, Mansfield, MA 02048-1 151 Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356 Internet: www.datel.com Email: sales@datel.com
DATEL (UK) LTD. Tadley, England T el: (01256)-880444 DATEL S.A.R.L. Montigny Le Bretonneux, France T el: 01-34-60-01-01 DATEL GmbH München, Germany T el: 89-544334-0 DATEL KK Tokyo, Japan Tel: 3-3779-1031, Osaka Tel: 6-6354-2025
DATEL makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. The DATEL logo is a registered DATEL, Inc. trademark.
®®
DS-0400B 07/00
ISO 9001
REGISTERED
DMS-20LCD-4/20
3½ DIGIT, LCD DISPLAY, 4-20mA LOOP-POWERED METERS
Loading...