Datasheet CF-21F30 Service manual (LG)

Page 1
ADJUSTMENT INSTRUCTIONS
* Safety precautions
1. It is safe to adjust after using insulating transformer between the power supply line and chassis input to prevent the risk of electric shock and protect the instrument.
2.Never disconnect leads while the TV receiver is on.
3. Don't short any portion of circuits while power is on.
4. The adjustment must be done by the correct appliances. But this is changeable in view of productivity.
5. Unless otherwise noted, set the line voltage to 220Vac+_
20%, 50/60Hz.
* Test Equipment required
1. Swee p Generator
2. Marker Generator(38.0MHz: Picture/32.5MHz: Sound)
3. Alignmen t Scope(5121A)
4. Patter n Generator(PAL/SECAM)
5. DC Power Supply
6.Color analyzer
7.Multimeter(Volt meter)
Preparation for VCO Adjustment
1. Connect the measuring equipment to the TV as shown in Fig. 1
2. Set RF output level of Sweep Generator to 90dBuV.
* VCO (Voltage Controlled Oscillator)
Adjustment
Test Point : JP4(L504)
Adjust : VL501
1) Turn on DC power supplies.
2) Adjust VCO ADJ.
Carrier (PC) may be at the lowest position as shown Fig.
2.
Fig. 2: Output waveform on Alignment Scope
NOTE: When performing this adjustment, if there are 2
adjusted point in VL501, select the lower core position.
coil(L501)so that the level of Picture
SC (Sound Carrier) : 32.5 MHz
PC (Picture Carrier) : 38.0 MHz
MAIN BOARD
C533 (JP 3)
J9 AGC ADJ.
RF out
SWEEP S.G with Marker
CK
0.01uF
TUNER
Z101 (JP 1)
Hor
Ver
5
VL501 VCO ADJ.
48
Alignment Scope
7
L504
(JP 4)
IC501
3.3K
DC POWER SUPPLY
5.0 +0.1V
Fig. 1: Connection Diagram of Equipment for VCO Adjustment
IC401
1
(JP 6)
DC POWER SUPPLY
16 +0.5V
* RF AGC (Auto Gain Control)
Adjustment
Test Point :
Adjust : VR501
The RF AGC control VR501 was aligned at the time of
manufacture for optimum performance over a wide range
conditions. Readjust
unless unusual local conditions exist, such as;
1)Channel interference in a CATV system
2)Picture bending and/or color beats, which are unusually due to excessive RF signal input when the reciever is too close to a transmitting tower or when the receiver is connected to an antenna distribution system where the RF signal has been amplified. In this case, the input signal should be attenuated(with pad or filter) to a satisfactory level. Picture noise caused by "broadcast noise" or weak
3) signal. If the broadcast is "clean" and the RF signal is at least 1mV (60dBu), the picture will be noise free in any area.
J9(AGC ADJ.) or Observing Display
VR501 should not be necessary
- 1-
Page 2
Adjusting the VR501(RF AGC)control to one end of
rotation will usually cause a relatively poor signal to noise ratio; Adjusting to the other end of rotation will usually cause a degradation of over load capabilities resulting on color beats or adjacent channel interference.
For the best results, adju performing on all other local channels, or Refer to the
following Table 1.
st VR501contol while
* Screen & White Balance
(color temperatur e) Adjustment
NOTE:
1. This adjustment should be performed after warming up for 20 minutes.
2.The color bias controls (VR901, VR902, VR903) affect the low light (dark) area of the picture while the color drive controls (VR904, VR905) affect the high light (white) areas.
Tuner P/N 113-118C/D/F 113-238H 6700VMV001A
Maker LG-ALPS LG-ALPS SANYO
Adjustment Voltage
5.7+_0.1Vdc
6.0+_0.1Vdc
4.9+_0.1Vdc
<Table 1>
REMARK
0+_1dBuV
RF 6 RF 60+_1dBuV RF 60+_1dBuV
* Vertical Height, Center Adjustment
Test Poin t:Observing display
Adjust : VR301(Vertical Height)
VR302 (Vertical Center)
1) Tune the TV set to receive a digital test pattern.
2) Set standard picture mode(contrast: 80, bright :60, color: 50).
3)Adjust the Vertical height co
circle of a digital test pattern may be located within the effective screen of the CPT.
4) Adjust the Vertical center
obtaining geometric center of valuable display vertically.
ntrol (VR301)so that the
control (VR302)for
1) Set all the controls (VR901-VR905) on CPT Board to geometric center position. Set the standard mode (contrast : 80, bright : 60, color : 50).
2)
3) Set the AV mode, adjust and set the screen volume of FBT at just cut-off position(No AV input signal).
4)Set the TV mode, tune the TV set to receive white pattern. By using color analyzer (white balance checker), adjust
5)
X position equals to +_8, it means that color temperature is 10,000+_800 at low light (4.
5ftL) and high light (over 45ftL).
281+_8 and Y position equals to 288
* Focus Adjustment
NOTE: This adjustment should be performed after
warming up for 10 minutes.
Test Poin t: Observing display
Adjust : Focus control of FBT
1) Tune the TV set to receive a digital test pattern.
2)Adjust the Focus control for the best overall focus.
* Horizontal Center Adjustment
Test Poin t: Observing display
Adjust : VR502
1) Tune the TV set to receive a PAL digital pattern.
2) Adjust the Horizontal center co
obtaining geometric center of valubale display horizontally.
ntrol(VR502)for
- 2-
Page 3
PURITY & CONVERGENCE ADJUSTMENT
Caution:
Convergence and Purity have been factory aligned. Do not attempt to tamper with these alignments. However, the effects of adjacent receiver components, or replacement of picture tube or deflection yoke may require the need to readjust purity any convergence.
DEFLECTION YOKE
PURITY &CONVERGENCE MAGNET ASSEMBLY
6-POLE
,,,
RUBBER WEDGES
,,
,,
,,,
PURITY MAGNET
4-POLE
GLASS CLOTH TAPE
X-AXIS YOKE POSITIONING (L/R PURITY)
5.Reconnect the internal degaussing coil.
6. Position the beam bender locking rings at the 9 o'clock position and the other three pairs of tabs (2,4 and 6 pole magnets) at the 12 o'clock position.
6-POLE
6-POLE
MAGNETS
4-POLE MAGNET
MAGNES
CONVERGENCE MAGNET ASSEMBLY
CONVERGENCE MAGNET ASSEMBLY
PURITY MAGNET(2-POLE)
* Purity Adjustment
This procedure DOES NOT apply to bonded yoke and picture tube assemblies. The instrument should be at room temperature (60 degrees F or above) for six (6) hours and be operating at low beam current (dark background) for approximately 20 to 30 minutes before performing purity adjustments.
CAUTION:Do not remove any trim magnets that may be
attached to the bell of the picture tube.
1. Remove the AC power and disconnect the internal degaussing coil.
2. Remove the yoke from the neck of the picture tube.
3. If the yoke has the tape version beam bender, remove it and replace it with a adjustable type beam bender (follow the instructions provided with the new beam bender)
4. Replace the yoke on the picture tube neck, temporarily remove the three (3) rubber wedges from the bell of the picture tube and then slide the yoke completely forward.
7. Perform the following steps, in the order given, to prepare the receiver for the purity adjustment procedure.
a. Face the receiver in the "magnetic north" direction.
b. Externally degauss the receiver screen with the television
power turned off.
c. Turn the television on for approximately 10 seconds to
perform internal degaussing and then turn the TV off.
d. Unplug the internal degaussing coil. This allows the
thermistor to cool down while you are performing the purity adjustment. DO NOT MOVE THE RECEIVER FROM ITS "MAGNETIC NORTH" POSITION.
e. Turn the receiver on and obtain a red raster by increasing
the red bias control (CW) and decreasing the bias controls for the remaining two colors (CCW).
f. Attach two round magnets on the picture tube screen at 3
o'clock and 9 o'clock positions, approximately one (1) inch from the edge of the mask (use double-sided tape).
3-2
Page 4
1.ADJUST YOKE Z-AXIS FIRST TO GET EQUAL BLUE COLOR CIRCLES
MAGNETS
RED RED
2 .ADJUST BEAM BENDER 2 POLE MAGNET TO GET FOUR EQUAL COLOR CIRCLES
8. Referring to above, perform the following two steps: a. Adjust the yoke Z-axis to obtain equal blue circles. b. Adjust the appropriate beam bender tabs to obtain correct
purity (four equal circles).
9. After correct purity is set, tighten the yoke clamp screw and
remove the two screen magnets.
10.Remove the AC power and rotate the receiver 180 degrees
(facing "magnetic south").
11. Reconnect the internal degaussing coil.
12. Turn the receiver on for 10 seconds (make sure the receiver
came on) to perform internal degaussing, and then turn the receiver off.
13. Unplug the internal degaussing coil.
14. Turn on the receiver and check the purity by holding one (1)
round magnet at the 3 o'clock and a second round magnet at 9 o'clock position. If purity is not satisfactory, repeat steps 8 through 14.
15. Turn off the receiver and reconnect the internal degaussing
coil.
* Convergence Adjustment
Caution:This procedure DOES NOT apply to bonded yoke and
picture tube assemblies. Do not use screen magnets during this adjustment procedure. Use of screen magnets will cause an incorrect display.
1. Remove AC power and disconnect the internal degaussing
coil.
2. Apply AC Power and set the brightness to the Picture Reset
condition. Set the Color control to minimum.
3. Apply 8V to the pin.
6. Reconnect the internal degaussing coil and apply AC power.
7. Turn the receiver on for 10 seconds to perform internal degaussing and then turn the receiver off again.
8. Unplug the internal degaussing-coil.
9. Turn on the receiver, connect a signal generator to the VHF antenna terminal and apply a crosshatch signal.
Caution:During the convergence adjustment procedure, be
very careful not to disturb the purity adjustment tabs are accidentally move, purity should be confirmed before proceeding with the convergence adjustments.
Note:
Make sure the focus is set correctly on this instrument
before proceeding with the following adjustment.
10. Converge the red and blue vertical lines to the green vertical line at the center of the screen by performing the following steps (below TABLE). a. Carefully rotate both tabs of the 4-pole ring magnet
simultaneously in opposite directions from the 12 o'clock position to converge the red and blue vertical lines.
b. Carefully rotate both tabs of the 6-pole ring magnet
simultaneously in opposite directions form the 12 o'clock position to converge the red and blue (now purple) vertical lines with the green vertical line.
11. Converge the red and blue horizontal with the green line at the center of the screen by performing the following steps. (below TABLE)
a. Carefully rotate both tabs of the 4-pole ring magnet
simultaneously in the same direction (keep the spacing between the two tabs the same) to converge the red and blue horizontal lines.
b. Carefully rotate both tabs of the 6-pole ring magnet
simultaneously in same direction (keep the spacing between the two tabs the same) to converge the red and blue (now purple) horizontal lines with the green horizontal line.
c. Secure the tabs previsouly adjusted by locking them in
place with the locking tabs on the beam bender.
4. Adjust the Red, Green and Blue Bias controls to get a dim white line.
5. Remove the AC power and 8V from the pin.
3-3
Page 5
3-4
RING PAIRS
4
POLE
ROTATION DIRECTION
OF BOTH TABS
OPPOSITE
SAME
OPPOSITE
SAME
MOVEMENT OF RED
AND BLUE BEAMS
B B
RR
OR
OR
B R B R
OR
B R
B R
B R
OR
B
R
6
POLE
12. While watching the 6 o'clock positions on the screen, rock the front of the yoke in a vertical (up/down) direction to converge the red and blue vertical lines. (Fig upper left)
13. Temporarily place a rubber wedge at the 12 o'clock position to hold the vertical position or the yoke.
14.
Check the 3 o'clock and 9 o'clock areas to confirm that the red and blue horizontal lines are converged. If the lines are not converged, slightly offset the vertical tilt of the yoke (move the rubber wedge if necessary) to equally balance the convergence error of the horizontal lines at 3 o'clock and 9 o'clock and the vertical lines at 6 o'clock and 12 o'clock.
15. Place a 1.5 inch piece of glass tape over the rubber foot at the rear of the 12 o'clock wedge.
16. While watching the 6 o'clock and 12 o'clock areas of the screen, rock the front of the yoke in the horizontal (left to right) motion to converge the red and blue horizontal lines. (Fig. upper right)
17. Temporarily place a rubber wedge at the 5 o'clock and 7 o'clock positions to hold the horizontal position of the yoke.
18. Check the 3 o'clock and 9 o'clock areas to confirm that the red and blue vertical lines are converged. If the lines are not converged, slightly offset the horizontal tilt of the yoke (move the temporary rubber wedges if necessary) to equally balance the convergence error of the horizontal lines at 6 o'clock and 12 o'clock and the vertical lines at 3 o'clock and 9 o'clock.
19. Using a round magnet confirm purity at the center, right and left sides and corners. See Purity Adjustment Procedure.
20. Reconfirm convergence and apply a 1.5 inch piece of glass tape over the rubber foot at the rear of the 5 o'clock and the 7 o'clock wedges.
RED
BLUE
RED BLUE
BLUE
RED
GREEN
GREEN
BLUE RED
GREEN
GREEN
ADJUSTMENT
VIEWING
AREA
UP/DOWN ROCKING OF THE YOKE CAUSES OPPOSITE ROTATION OF RED AND BLUE RASTERS
ADJUSTMENT
VIEWING
AREA
RED
RED
GREEN
TV SCREEN
LEET/RIGHT ROCKING OF THE YOKE CAUSES OPPOSITE SIZE CHANGE OF THE RED AND BLUE RASTERS
UP/DOWN ROCKING OF THE YOKE CAUSES OPPOSITE ROTATION OF RED AND BLUE RASTERS
LEFT/RIGHT ROCKING OF THE YOKE CAUSES OPPOSITE SIZE CHANGE OF THE RED AND BLUE RASTERS
Loading...