54ABT244 Octal Buffer/Line Driver with TRI-STATE
®
Outputs
General Description
The ’ABT244 is an octal buffer and line driver with TRI-STATE outputs designed to be employed as a memory and address driver, clock driver, or bus-oriented transmitter/ receiver.
Features
n Non-inverting buffers n Output sink capability of 48 mA, source capability of
24 mA
n Output switching specified for both 50 pF and 250 pF
loads
n Guaranteed simultaneous switching, noise level and
dynamic threshold performance
n Guaranteed latchup protection n High impedance glitch free bus loading during entire
power up and power down cycle
n Nondestructive hot insertion capability n Disable time less than enable time to avoid bus
contention
n Standard Microcircuit Drawing (SMD) 5962-9214701
Ordering Code
Military Package Package Description
Number
54ABT244J-QML J20A 20-Lead Ceramic Dual-In-Line 54ABT244W-QML W20A 20-Lead Cerpack 54ABT244E-QML E20A 20-Lead Ceramic Leadless Chip Carrier, Type C
Connection Diagrams
Pin
Names
Description
OE
1
,OE2Output Enable Input
(Active Low)
I
0–I7
Inputs
O
0–O7
Outputs
Truth Table
OE1I
0–3O0–3OE2I4–7O4–7
HXZHXZ LHHLHH LLLLLL
H=HIGH Voltage Level L=LOW Voltage Level X=Immaterial Z=High Impedance
TRI-STATE®is a registered trademark of National Semiconductor Corporation.
Pin Assignment for
DIP and Flatpak
DS100203-1
Pin Assignment for LCC
DS100203-2
July 1998
54ABT244 Octal Buffer/Line Driver with TRI-STATE Outputs
© 1998 National Semiconductor Corporation DS100203 www.national.com
Page 2
Absolute Maximum Ratings (Note 1)
If Military/Aerospace specified devices are required, please contact the National Semiconductor Sales Office/ Distributors for availability and specifications.
Storage Temperature −65˚C to +150˚C Ambient Temperature under Bias −55˚C to +125˚C Junction Temperature under Bias
Ceramic −55˚C to +175˚C
V
CC
Pin Potential to Ground Pin −0.5V to +7.0V Input Voltage (Note 2) −0.5V to +7.0V Input Current (Note 2) −30 mA to +5.0 mA Voltage Applied to Any Output
in the Disabled or Power-Off State −0.5V to 5.5V in the HIGH State −0.5V to V
CC
Current Applied to Output
in LOW State (Max) twice the rated I
OL
(mA) DC Latchup Source Current −500 mA Over Voltage Latchup (I/O) 10V
Recommended Operating Conditions
Free Air Ambient Temperature
Military −55˚C to +125˚C
Supply Voltage
Military +4.5V to +5.5V
Minimum Input Edge Rate (V/t)
Data Input 50 mV/ns Enable Input 20 mV/ns
DC Electrical Characteristics
Symbol Parameter ABT244 Units V
CC
Conditions
Min Typ Max
V
IH
Input HIGH Voltage 2.0 V Recognized HIGH Signal
V
IL
Input LOW Voltage 0.8 V Recognized LOW Signal
V
CD
Input Clamp Diode Voltage −1.2 V Min I
IN
=
−18 mA
V
OH
Output HIGH Voltage 54ABT 2.5 V Min I
OH
=
−3 mA
54ABT 2.0 V Min I
OH
=
−24 mA
V
OL
Output LOW Voltage 54ABT 0.55 V Min I
OL
=
48 mA
I
IH
Input HIGH Current 5 µA Max V
IN
=
2.7V (Note 4)
5V
IN
=
V
CC
I
BVI
Input HIGH Current Breakdown Test 7 µA Max V
IN
=
7.0V
I
IL
Input LOW Current −5 µA Max V
IN
=
0.5V (Note 4)
−5 V
IN
=
0.0V
V
ID
Input Leakage Test 4.75 V 0.0 I
ID
=
1.9 µA
All Other Pins Grounded
I
OZH
Output Leakage Current 50 µA 0 − 5.5V V
OUT
=
2.7V; OE
n
=
2.0V
I
OZL
Output Leakage Current −50 µA 0 − 5.5V V
OUT
=
0.5V; OE
n
=
2.0V
I
OS
Output Short-Circuit Current −100 −275 mA Max V
OUT
=
0.0V
I
CEX
Output High Leakage Current 50 µA Max V
OUT
=
V
CC
I
ZZ
Bus Drainage Test 100 µA 0.0 V
OUT
=
5.5V; All Others GND
I
CCH
Power Supply Current 50 µA Max All Outputs HIGH
I
CCL
Power Supply Current 30 mA Max All Outputs LOW
I
CCZ
Power Supply Current 50 µA Max OE
n
=
V
CC
;
All Others at VCCor Ground
I
CCT
Additional ICC/Input Outputs Enabled 2.5 mA Max V
I
=
V
CC
− 2.1V
Outputs TRI-STATE 2.5 mA Enable Input V
I
=
V
CC
− 2.1V
Outputs TRI-STATE 50 µA Data Input V
I
=
V
CC
− 2.1V
All Others at V
CC
or Ground
I
CCD
Dynamic I
CC
No Load mA/ Max Outputs Open
(Note 4) 0.1 MHz OE
n
=
GND, (Note 3)
One Bit Toggling, 50%Duty Cycle
Note 1: Absolutemaximum ratings are values beyond which the device may be damaged or have its useful life impaired. Functional operation under these conditions is not implied.
Note 2: Either voltage limit or current limit is sufficient to protect inputs. Note 3: For 8 bits toggling, I
CCD
<
0.8 mA/MHz.
Note 4: Guaranteed, but not tested.
www.national.com 2
Page 3
AC Electrical Characteristics
Symbol Parameter 54ABT Units Fig.
No.
T
A
=
−55˚C to +125˚C
V
CC
=
4.5V–5.5V
C
L
=
50 pF
Min Max
t
PLH
Propagation Delay 1.0 5.3 ns
Figure 5
t
PHL
Data to Outputs 1.0 5.0
t
PZH
Output Enable 0.8 6.5 ns
Figure 4
t
PZL
Time 1.2 7.9
t
PHZ
Output Disable 1.2 7.6 ns
Figure 4
t
PLZ
Time 1.0 7.9
Capacitance
Symbol Parameter Typ Units Conditions
T
A
=
25˚C
C
IN
Input Capacitance 5.0 pF V
CC
=
0V
C
OUT
(Note 5) Output Capacitance 9.0 pF V
CC
=
5.0V
Note 5: C
OUT
is measured at frequency f=1 MHz, per MIL-STD-883B, Method 3012.
t
PLH
vs Temperature (TA)
C
L
=
50 pF, 1 Output Switching
DS100203-11
t
PHL
vs Temperature (TA)
C
L
=
50 pF, 1 Output Switching
DS100203-12
Dashed lines represent design characteristics; for specified guarantees refer to AC Characteristics Table.
3 www.national.com
Page 4
Capacitance (Continued)
t
PLH
vs Load Capacitance
1 Output Switching, T
A
=
25˚C
DS100203-13
t
PHL
vs Load Capacitance
1 Output Switching, T
A
=
25˚C
DS100203-14
t
PLH
vs Load Capacitance
8 Outputs Switching, T
A
=
25˚C
DS100203-15
t
PHL
vs Load Capacitance
8 Outputs Switching, T
A
=
25˚C
DS100203-16
t
PZL
vs Temperature (TA)
C
L
=
50 pF, 1 Output Switching
DS100203-17
t
PLZ
vs Temperature (TA)
C
L
=
50 pF, 1 Output Switching
DS100203-18
Dashed lines represent design characteristics; for specified guarantees refer to AC Characteristics Table.
www.national.com 4
Page 5
Capacitance (Continued)
t
PZH
vs Temperature (TA)
C
L
=
50 pF, 1 Output Switching
DS100203-19
t
PHZ
vs Temperature (TA)
C
L
=
50 pF, 1 Output Switching
DS100203-20
t
PZH
vs Temperature (TA)
C
L
=
50 pF, 8 Outputs Switching
DS100203-21
t
PHZ
vs Temperature (TA)
C
L
=
50 pF, 8 Outputs Switching
DS100203-22
t
PZL
vs Temperature (TA)
C
L
=
50 pF, 8 Outputs Switching
DS100203-23
t
PLZ
vs Temperature (TA)
C
L
=
50 pF, 8 Outputs Switching
DS100203-24
Dashed lines represent design characteristics; for specified guarantees refer to AC Characteristics Table.
5 www.national.com
Page 6
Capacitance (Continued)
t
PZL
vs Load Capacitance
8 Outputs Switching
T
A
=
25˚C
DS100203-25
t
PZH
vs Load Capacitance
8 Outputs Switching
T
A
=
25˚C
DS100203-26
t
PLH
and t
PHL
vs Number
Outputs Switching V
CC
=
5.0V,
T
A
=
25˚C, C
L
=
50 pF
DS100203-27
ICCvs Frequency,
Average, T
A
=
25˚C,
All Outputs Unloaded/Unterminated
DS100203-28
Dashed lines represent design characteristics; for specified guarantees refer to AC Characteristics Table.
www.national.com 6
Page 7
AC Loading AC Waveforms
DS100203-3
*Includes jig and probe capacitance
FIGURE 1. Standard AC Test Load
DS100203-5
FIGURE 2. Test Input Signal Levels
Amplitude Rep. Rate t
W
t
r
t
f
3.0V 1 MHz 500 ns 2.5 ns 2.5 ns
FIGURE 3. Test Input Signal Requirements
DS100203-6
FIGURE 4. TRI-STATE Output HIGH
and LOW Enable and Disable Times
DS100203-7
FIGURE 5. Propagation Delay Waveforms for
Inverting and Non-Inverting Functions
7 www.national.com
Page 8
8
Page 9
Physical Dimensions inches (millimeters) unless otherwise noted
20-Terminal Ceramic Chip Carrier (L)
NS Package Number E20A
20-Lead Ceramic Dual-In-Line (D)
NS Package Number J20A
9 www.national.com
Page 10
Physical Dimensions inches (millimeters) unless otherwise noted (Continued)
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DE­VICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF NATIONAL SEMI­CONDUCTOR CORPORATION. As used herein:
1. Life support devices or systems are devices or sys­tems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and whose fail­ure to perform when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in a significant injury to the user.
2. A critical component in any component of a life support device or system whose failure to perform can be rea­sonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
National Semiconductor Corporation
Americas Tel: 1-800-272-9959 Fax: 1-800-737-7018 Email: support@nsc.com
www.national.com
National Semiconductor Europe
Fax: +49 (0) 1 80-530 85 86
Email: europe.support@nsc.com Deutsch Tel: +49 (0) 1 80-530 85 85 English Tel: +49 (0) 1 80-532 78 32 Français Tel: +49 (0) 1 80-532 93 58 Italiano Tel: +49 (0) 1 80-534 16 80
National Semiconductor Asia Pacific Customer Response Group
Tel: 65-2544466 Fax: 65-2504466 Email: sea.support@nsc.com
National Semiconductor Japan Ltd.
Tel: 81-3-5620-6175 Fax: 81-3-5620-6179
20-Lead Ceramic Flatpak (F)
NS Package Number W20A
54ABT244 Octal Buffer/Line Driver with TRI-STATE Outputs
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications.
Loading...