Dataprobe K-AB-T50 User Manual

Page 1
Installation and Operation
50 Pin Telco A/B Switch
Models K-AB-T50, K-AB-T50-R
GENERAL DESCRIPTION
The Connection to the Common circuit is provided using a Male 50 pin Telco connector. The A and B connections are Female 50 pin Telcos. LED indicators display the current position of the switch.
The K-AB-T50 models are capable of switching either all 50 leads, or provide straps to common pins 25 and/or 50 for grounding applications. The switches also provide an additional relay poll brought out for status or feedback requirements.
The K-AB-T50 is designed to switch dedicated analog lines and digital communication circuits.
The standalone unit is packaged in a plastic enclosure and is provided with a UL approved wall mounted transformer. The rack card is designed to be used in conjunction with Card Nest model K-AB-R-12, which can hold up to 6 of the K-AB-T50 cards and provides power to the cards.
OPERATION
The switch is capable of switching in the following manners:
1) Contact Closure
Switch to B on Contacts Close, Switch to A on Contacts Open.
2) EIA (RS-232) or TTL High
Switch to B on Control lead High, Switch to A on Control lead Low.
3) EIA (RS-232) or TTL Low
Switch to B on Control lead Low, Switch to A on Control lead High.
Connection to these control leads is made using the 9 pin D Subminiature connector on the rear of the standalone units and the 50 pin Control connector on the Rack Nest.
REF: K1\KAB-T50_V970902X.DOC
Technical Support Hotline: (201) 967-8788
11 Park Place / Paramus, New Jersey 07652 TEL: 201-967-9300 FAX: 201-967-9090
Website: www. dataprobe.com Email: tech@dataprobe.com
Page 2
Model KAB-T50 Page 2
In addition to lead switching, the unit has a front panel three position manual toggle switch. The toggle selects either Position A, Position B or Automatic (external lead) control. In the A or B position, the external control is locked out.
The Switch provides status indication with A and B LEDs on the front panel. Status information is also provided with an extra set of Form C relay contacts. These contacts are available on the DB9 connector on the standalone units or on the 50 pin Status Connector of the Rack Nest.
CONFIGURATION
Refer to Figure 1 Component Location.
External Control Signal
Selection of the type of external Control signal used is made using jumper groups E1 and E2. * = Factory Default
Control Signal E1 E2
Contact Closure Jumper Out Jumper in CONTACT * RS-232 High or Low Jumper Out Jumper in EIA/TTL TTL High or Low Jumper In Jumper in EIA/TTL
Pin 25 and 50 Switched or Tied
Telco pins 25 and 50 can either be switched or tied together for grounding applications. Selection is made using jumper groups JP1, JP2, JP3, JP4.
Pin 25 Switched JP1 and JP2 Jumpers Out * Pin 25 Tied JP1 and JP2 Jumpers In
Pin 50 Switched JP3 and JP4 Jumpers Out * Pin 50 Tied JP3 and JP4 Jumpers In
INSTALLATION
Connection of the Common, Port A and Port B Telco connections are made on the rear of the Switch. The Common port provides a Male Telco and the A and B ports are Female.
On Standalone units, connect the External control leads using the 9 pin D Subminiature connector, rear panel. On rack models, connect the external control leads through the 50 pin CONTROL connector on the rear of the chassis.
The following pins are used on the standalone and rack models.
K-AB-T50, Standalone. 9 pin D Subminiature Female, Rear Panel.
Page 3
Model KAB-T50 Page 3
Pin # Designation
1 EIA (RS-232) / TTL High 2 Ground 3 EIA (RS-232) / TTL Low 4 Contact (To Ground) 5 Not Used 6 Status Relay: Normally Open (B) 7 Status Relay: Common 8 Status Relay: Normally Closed (A) 9 Not Used
K-AB-T50-R Rack Card. Uses Card Nest Telco CONTROL and STATUS Connectors.
K-AB-R-12 Card Nest. Holds up to six K-AB-T50 cards in card positions 1, 3, 5, 7, 9, and 11 (each card requires two slots in the nest)
Control
Card Position : 1 3 5 7 9 11
Contact (To Ground) 1 5 9 13 17 21 Signal Ground 26 30 34 38 42 46 EIA High 2 6 10 14 18 22 EIA Low 27 31 35 39 43 47
Status
Card Position : 1 3 5 7 9 11
Status Relay: COM 1 5 9 13 17 21 Status Relay: N/C 26 30 34 38 42 46 Status Relay: N/O 2 6 10 14 18 22 Not Used 27 31 35 39 43 47
Page 4
Model KAB-T50 Page 4
SPECIFICATIONS
Switch Interface
50 pin Telco (Champ) connectors Common = Male, A and B Ports = Female. 48 / 50 leads switched, Strap Selectable.
Indicators
Two Red LEDs indicate Switch status A or B. LED's are driven by relays.
Relays
Standard Coil relays. Power off condition relaxes relays to Position A. Gold clad Relay contacts rated for low level signals & up to 2A @ 30 VDC.
Stand Alone Enclosure
Height....2.75" Width.....8.00"
Depth.....6.25" Weight....1.20 lbs
Power Source; UL Approved Wall Mounted Power Supply. 115VAC 60 Hz External Control and Status Interface; 9 pin D Subminiature, Female
Rack Mounted Card Nest
Standard 19" equipment Cabinet Mount, 8.75" high. Model K-AB-R-12 Accepts up to 6 K-AB-T50-R cards. Includes power supply for 115VAC 60Hz. External Relay Controls and Status Contacts Via Two 50 Pin Telco Connectors, Female
Control Circuits
EIA RS-232/V.35, Internal or External: Standard EIA RS-232C Receiver LOW = -30 VDC to +1.75 VDC HIGH = +1.75 VDC to +30 VDC Maximum Input ±30 VDC TTL, External: LOW = 0.8 VDC HIGH = 2.0 VDC Maximum Input +5.5 VDC
Page 5
Model KAB-T50 Page 5
AUTO A B
Configuration Jumper Setti ngs
Contact Closure to Ground
E1
EIA Control Lead High or Low
E1
TTL Lead High or Low
E1
B PORT
E1
E2
TTL
E2
TTL
E2
TTL
COMMON
E2
TTL
EIA/ TTL CONTACT
EIA/ TTL CONTACT
EIA/ TTL CONTACT
EIA/ TTL CONTACT
A PORT
JP1
JP3
AB
JP2
JP4
Pin 25
Pin 50
Jumpers: Out = Swit ched In = Tied
K- AB- T50 COMPONENT LAYOUT
Page 6
Model KAB-T50 Page 6
TECHNICAL SUPPORT, RETURNS and WARRANTY
Dataprobe Technical Support is available 8:30AM to 5:30PM ET to assist you in the installation and operation of this product. To obtain Technical Support call our Tech Support Hotline at 201- 967-8788 or Email us at tech@dataprobe.com
. Please have the following information available when you call:
Model of Product
Serial Number
Data of Purchase
Name of Seller (if other than Dataprobe)
If you purchased this product through an Authorized Dataprobe Reseller, you should contact them first, as they may have information about the application that can more quickly answer your questions.
WARRANTY
Seller warrants this product, if used in accordance with all applicable instructions, to be free from original defects in material and workmanship for a period of One Year from the date of initial purchase. If the product should prove defective within that period, Seller will repair or replace the product, at its sole discretion.
Service under this Warranty is obtained by shipping the product (with all charges prepaid) to the address below. Seller will pay return shipping charges. Call Dataprobe Technical Service at (201) 967-8788 to receive a Return Materials Authorization (RMA) Number prior to sending any equipment back for repair. Include all cables, power supplies and proof of purchase with shipment.
THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT, MISUSE, ABUSE OR NEGLECT. SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN. EXCEPT TO THE EXTENT PROHIBITED BY LAW, ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF MERCHANT ABILITY OR FITNESS FOR ANY PURPOSE ARE LIMITED TO THE WARRANTY PERIOD SET FORTH ABOVE; AND THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES.
Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from jurisdictions to jurisdiction.
WARNING: The individual user should take care to determine prior to use whether this device is suitable, adequate or safe for the use intended. Since individual applications are subject to great variation, the manufacturer makes no representation or warranty as to the suitability of fitness for any specific application.
Dataprobe Inc. 11 Park Place Paramus, NJ 07652
,
Loading...