Dataprobe iBoot-G2 Quick Start

Page 1
Fig.1 Connect Network
Fig. 3 Connect Power
Fig. 4 Status and Control Page

Quick Start Guide

What’s Included

iBoot-G2 Unit
Power Input Cable for North America
Power Outlet Cable for North America
Network Cable
Quick Start Guide
dataprobe.com/support/iboot
Complete Product Manual
Device Management Utility
Latest iBoot-G2 Firmware
Software Developer Tools

Connections

1. Connect Network. iBoot-G2 supports 10/100 Ethernet using the cable
supplied, or other suitable uns hielded twisted pair (Cat 5) c abling. When power is connected to the iBoot-G2, the green Activity LEDs on the network connector indicate when the network connecti on is properly established.
2. Connect Powered Device. Connect the device to be po wered ON and OFF
to the IEC receptacle marked A/C Outlet. An IEC-320 to North American ( NEMA 5-
15) power cord is included for connecting the iBoot outlet to the device to be controlled. If the device has a po wer switch, turn i t on, to allow iBoot -G2 to control the power.
Make sure that the combined load of all controlled devices does not exceed 12 Amps for 105-125VAC or 10 Amps for 210­240VAC.
3. Connect Power Mains Connect the supplied power cord to the connector
labeled AC Input, and the other end to your AC source. If a power cord with a different terminating plug is required, be s ure it is properly rated and meets all the required local electrical standards.

Web Browser Access

Factory Default IP Address: 192.168.1.254 Factory Default Security Credentials:
Role Username Password
Administrator admin admin
To access the iBoot from the default I P Address, requires the PC to be on the same local network (IP Address 192. 168.1.nnn). If it is not, change the iBoot IP Address using one of the methods on the following page.
After pointing the browser t o the IP Address of the iBoot, enter the Administrator Username and Password to access the complete setup features. Enter the User credentials to ac cess only the power control. Once the user is validated, the Control and Status is displayed.
To control the power, click on the appropriate button. During power cycling, the Power Status bar will indi cate the temporary status, with a blue background. Once the cycle is complete, the status bar will revert to its original condition.
Iboot-g2 quick start © 2013 Dataprobe Inc. V110120E
Page 2
Fig. 5 Device Management Utility
Fig. 6 Network Setup Page

Changing the IP Address

1. Device Management Utility Obtain the Device
Management Utility (DMU) from Dataprobe’s website at
dataprobe.com/support/iboot. The DMU provides the easiest
means to find and configure your iBoot-G2 for use. It can discover all the iBoots on your network, display the current IP address of each, and allow setti ng of any valid IP address.
Note: The IP address can only be set within the first two minutes of powering up the iBoot. The Setup Utility will only work with iBoots on the same physical subnets as the PC.
The iBoot-G2 Setup Utility can also be us ed to return an iBoot­G2 to its Factory Default condition. T his can be used to r ecover an iBoot-G2 with a lost pass word. Highlight an iBoot-G2 from the display and click Factory Defaults. This must also be done within the first two minutes of powering up the iBoot.
Complete instructions for the DMU are provided with the download, and in the full iBoot-G2 Manual.
2. Web Page Setup From the home page, click on Setup,
then Network. Enter the new IP Address, Subnet Mask and Gateway, then click Save. Click t he Reboot butt on (or press the reset button next to the power outl et LED) to restart the iBoot­G2 with the new settings.
3. DHCP From the Home page, click on Setup, then Network.
Change the IP Mode from Static to DHCP. Click Save, then Reboot. The iBoot-G2 will obtain it s network settings from the server. Check the server, or use the Dev ice Mana gement U tilit y to obtain the new settings.

Important Safety Instructions

When using this product, basic safety precautions should always be followed to reduce the risk of fire,
electric shock, and injury to persons, including the following:
1. Read and understand all instructions.
2. Follow all warnings and marked on the product.
3. Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.
4. Do not use this product in an outdoor environment or near water, for example, near a bath tub, wash bowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool.
5. Do not place this product on an unstable cart, stand, or table. The product may fall, causing serious damage to the product.
6. Slots and openings in this product and the back or bottom are provided for ventilation to protect it from overheating; these openings must not be blocked or covered. The openings should never be blocked by placing the product on the bed, sofa, rug, or other similar surface. This product should never be placed near or over a radiator or heat register. This product should not be placed in a built-in installation unless proper ventilation is provided.
7. This product should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supply to your home, consult your dealer or local power company.
8. This product is equipped with a three wire grounding type plug, a plug having a third (grounding) pin. This plug will only fit into a grounding type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the grounding type plug. Do not use a 3­to-2 prong adapter at the receptacle; use of this type adapter may result in risk of electrical shock and/or damage to this product.
9. Do not allow anything to rest on the power cord. Do not locate this product where the cord will be abused by persons walking on it.
10. Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock.
11. Never push objects of any kind into this product through slots as they may touch dangerous voltage points or short out parts that could result in a risk of fire or electrical shock. Never spill liquid of any kind on the product.
12. To reduce the risk of electrical shock, do not disassemble this product, but take it to a qualified serviceman when some service or repair work is required. Opening or removing covers may expose you to dangerous voltages or other risks. Incorrect re-assembly can cause electric shock when the appliance is subsequently used.
13. Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions: a) W h en the power supply cord or plug is damaged or frayed. b) I f liquid has been spilled into the product. c) If the product has been exposed to rain or water. d) If the product does not operate normally by following the operating
instructions. Adjust only those controls that are covered by the operating instructions because improper adjustment of other controls may result in damage and will often require extensive work by a
qualified technician to restore the product to normal operation. e) If the product has been dropped or has been damaged. f) If the product exhibits a distinct change in performance.
14. Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning.
15. Do not use the telephone to report a gas leak in the vicinity of the leak.
16. Do not exceed the maximum output rating of the auxiliary power receptacle.
Page 3
1. Remove all cables
1. Install the Wall
2. Remove the four
2. Install the DIN rail
3. Install the wall
3. Ready for DIN rail
4. The unit is ready
1920033 Mounting Kit
iBoot G2 Series

Mounting Options

iBoot-G2+ is suitable for desktop or shelf mounting. A mounting kit for wall and DIN rail mounting is availab le. Order part:
1920034 Mounting Kit for iBoot-G2 Series

Installing the Wall Mounting Kit

from the unit
mounting screws from the underside of the unit.
Do not disassemble the unit.
mounting ears to the unit using the screws removed in Step 2

DIN Rail Mounting

Mounting Kit as shown.
clips using the four screws provided.
mounting.
for wall mounting. Use M3 or #4
screws (not included) for attachment to suitable surface.